Department Of Defence Research And Development - Karnataka

37894793 bids are invited for design supply installation commissioning and testing of electrical work dsitc , sitc of xlpe cables , sitc of dlp upvc , itc of wire , sitc of wiring , itc of wiring , sitc of cable termination , sitc of cable trays , sitc of earthing , itc of copper strip , sitc gi wires , sitc of lighting , sitc of industrial plugs , sitc of moduler box , sitc of ms supports total quantity : 3224...

Department of Defence Production - Karnataka

37532207 bids are invited for tank and paints mse gi wire , barbed wire , sintex triple layer tanks , emulsion paint , sand paper emery paper , weather proof rain water leak proof coatings supply of various items like gi wire barbed wire total quantity : 10231...

Medical Education Department - Karnataka

36882611 electrical items and providing electrical works on demand based on rate contract at kmio and pcc kalburgi , wires & cables point wiring using copper wire without switch supplying and wiring adopting loop system in existing pvc conduit / casing capping using 1100 v gradecopper frls pvc insulated 2x15sqmmcable confirming to the gtp without switch the other end of the wires shall be terminated with sufficient loose length in a wood / pvc round block complete for each outlet 5 / 23 medium point above 3mtr up to 6mtr from tapping point to out let via switch box etc., complete with all lead & lift, as per specifications and as per directions of the engineer in charge of the work pg 3 item 2.2.2 ( sr22 23 ) wire make : finolex / anchor / kei, wires & cables point wiring using copper wire without switch supplying and wiring adopting loop system in existing pvc conduit / casing capping using 1100 v gradecopper frls pvc insulated 2x15sqmmcable confirming to the gtp without switch the other end of the wires shall be terminated with sufficient loose length in a wood / pvc round block complete for each outlet 5 / 23 long point above 6mtr up to 10mtr from tapping point to out let via switch box etc., complete with all lead & lift, as per specifications and as per directions of the engineer in charge of the work pg 3 item 2.2.3 ( sr22 23 ) wire make : finolex / anchor / kei, wires & cables point wiring using copper wire without switch supplying and wiring adopting loop system in existing pvc conduit / casing capping using 1100 v grade copper frls pvc insulated 2x15sqmmcable confirming to the gtp without switch the other end of the wires shall be terminated with sufficient loose length in a wood / pvc round block complete for each outlet 5 / 23 two outlet in a row above 6mts up to 10mtr from tapping point to out let via switches box etc., complete with all lead & lift, as per specifications and as per directions of the engineer in charge of the work, supplying of extension boards with 3 mtrs 1.5 sqmm copper cable in legth 10”x7” wooden board with pvc plate comprising one no 16 amps socket, 20 amps switch, 3nos of 5 amps switch and 6 amps sockets 3nos, supplying of extension boards with 5 mtrs in length 1.5 sqmm pvc copper cable , 10”x7” wooden board with pvc plate comprising one no 16 amps socket, 20 amps switch, 2nos of 5 amps switch and 6 amps sockets 2nos, supplying and fixing of pvc casing and capping on the wall or ceiling using necessary materials like bends , screws at an interval of 300mm …etc as required pg 2 item 1.8.1 20 mm, supplying and fixing of pvc casing and capping on the wall or ceiling using necessary materials like bends , screws at an interval of 300mm …etc as required pg 2 item 1.8.2 25 mm, supplying and fixing of pvc casing and capping on the wall oe r ceiling using necessary materials like bends , screws at an interval of 300mm …etc as required pg 3 item 1.8. 3 32 mm, supplying and fixing of pvc casing and capping on the wall oe r ceiling using necessary materials like bends , screws at an interval of 300mm …etc as required pg 3 item 1.8. 4 38 mm, supplying and fixing of pvc casing and capping on the wall oe r ceiling using necessary materials like bends , screws at an interval of 300mm …etc as required pg 3 item 1.8. 5 50 mm, supplying and fixing of pvc casing and capping on the wall or ceiling using necessary materials like bends , screws at an interval of 300mm …etc 50x100 mm industrial type, supplying and fixing of s” hook made out of 14, mm dia pg 2 / 1.10, providing open conduit system supplying and drawing heavy gauze pvc conduit pipes19 / 20mm dia 2 mmthick conforming to is 2509 with suitable size bends , junction boxes, adhesive paste etc.. pg1 / 1.1.1 19 / 20mm dia 2 mm thick, providing open conduit system supplying and drawing heavy gauze pvc conduit pipes25 mm dia 2 mmthick conforming to is 2509 with suitable size bends , junction boxes, adhesive paste etc.. pg2 / 1.1.2 1.1.2 25 mm dia 2 mm thick, providing open conduit system supplying and drawing heavy gauze pvc conduit pipes32 mm dia 2.5 mmthick conforming to is 2509 with suitable size bends , junction boxes, adhesive paste etc.. p1 / 1.1.3 1.1.3 32mm dia 2.5 mm thick, providing open conduit system supplying and drawing heavy gauze pvc conduit pipes40 mm dia 2.5 mmthick conforming to is 2509 with suitable size bends , junction boxes, adhesive paste etc.. pg 1 / 1.1.4 1.1.4, concealed conduit system: supplying heavy gauge pvc conduit pipe 19 / 20 mm dia 2mm thick conforming to is 2509 with suitable size bends , metal / pvc junction boxes , adhesive paste etc.. and running before concreting the slab . the conduit should be tied to the reiforcemrnt rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using pvc end enclosures , run with 18 swg gi fish wire wherever necessary pg 1 / 1.2.1 1.2.1 19 / 20mm dia 2 mm thick, concealed conduit system: supplying heavy gauge pvc conduit pipe 19 / 20 mm dia 2mm thick conforming to is 2509 with suitable size bends , metal / pvc junction boxes , adhesive paste etc.. and running before concreting the slab . the conduit should be tied to the reiforcemrnt rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using pvc end enclosures , run with 18 swg gi fish wire wherever necessary pg 1 / 1.2.1 1.2.2 25mm dia 2 mm thick, concealed conduit system: supplying heavy gauge pvc conduit pipe 19 / 20 mm dia 2mm thick conforming to is 2509 with suitable size bends , metal / pvc junction boxes , adhesive paste etc.. and running before concreting the slab . the conduit should be tied to the reiforcemrnt rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using pvc end enclosures , run with 18 swg gi fish wire wherever necessary pg 1 / item 1.2.3 1.2.3 32mm dia 2 mm thick, providing groove cutting in the wall and fixing by bracing u or j hooks and cement plastering up to the wall surface and run with 18 swg fish wire run throught the conduit wherever necessary including supplying and fixing of heavy gauge pvc conduit pipe pg 1 / 1.3.1 1.3.1 19 / 20 mm dia 2 mm thick, providing groove cutting in the wall and fixing by bracing u or j hooks and cement plastering up to the wall surface and run with 18 swg fish wire run throught the conduit wherever necessary including supplying and fixing of heavy gauge pvc conduit pipe pg 1 / 1.3.2 1.3.2 25 mm dia 2 mm thick, providing groove cutting in the wall and fixing by bracing u or j hooks and cement plastering up to the wall surface and run with 18 swg fish wire run throught the conduit wherever necessary including supplying and fixing of heavy gauge pvc conduit pipe pg 1 / 1.3.3 1.3.3 32 mm dia 2 mm thick, providing groove cutting in the wall and fixing by bracing u or j hooks and cement plastering up to the wall surface and run with 18 swg fish wire run throught the conduit wherever necessary including supplying and fixing of heavy gauge pvc conduit pipe pg 1 / 1.3.4 1.3.4 40 mm dia 2.5 mm thick, supplying and drawing heavy duty 2 inch pvc pipe thickness 3mm, supplying and drawing heavy duty 2.5 inch pvc pipe thickness 3.25mm, supplying and drawing heavy duty 3 inch pvc pipe thickness 3.5mm, providing cpvc pipe for water supply line including labour charges and material charges 19 / 20 mm, providing plumbing works for the installation of geyser including supplying and fixing of taps for inlet and out let cpvc pipes and inlet control, supplying and fixing sheet metal box made out of 18 swg sheet metal with necessary holes for cable / conduit entry as required with one coat of primer of approved make etc pg1 / 1.4.3 1.4.3 135x75x65mm, supplying and fixing sheet metal box made out of 18 swg sheet metal with necessary holes for cable / conduit entry as required with one coat of primer of approved make etc pg 1 / 1.4.2 1.4.2 100x75x65mm, supplying and fixing sheet metal box made out of 18 swg sheet metal with necessary holes for cable / conduit entry as required with one coat of primer of approved make etc 1.4.1 75x75x65mm, supplying and fixing pvc / metal conduit deep junction box pg 1 / 1.5.1 19 / 20 mm deep junction box, supplying and fixing pvc / metal conduit deep junction box pg 1 / 1.5.2 25 mm deep junction box, supplying and fixing pvc / metal conduit deep junction box pg 1 / 1.5.3 32 mm deep junction box, supply and fixing / replacing of 6 / 16 / 32 amps electrical accessories on existing switch board pg 6 item 3.14.1 group a 3.14.1 6 amps sp switch, supply and fixing / replacing of 6 / 16 / 32 amps electrical accessories on existing switch board pg 6 item 3.14 group a 3.14.3 6 amps 3 way 5 pin socket, supply and fixing / replacing of 6 / 16 / 32 amps electrical accessories on existing switch board pg 6 item 3.14 group a 3.14.4 6 amps three pin top, supply and fixing of bakelite d.p / socket / switch with / without neon indicator over existing wood board or flush mounting in plastic / nitches as per is 1293 and is 3854 pg 6 item 3.14 group a 3.14.3 32 amps flush / projected type dp switch, supply and fixing of bakelite d.p / socket / switch with / without neon indicator over existing wood board or flush mounting in plastic / nitches as per is 1293 and is 3854 pg6 item 3.14 group a 3.14.15 electronic stepped regulator, supply and fixing of bakelite d.p / socket / switch with / without neon indicator over existing wood board or flush mounting in plastic / nitches as per is 1293 and is 3854 pg6 item 3.14 group a 3.14.12 16 amps three pin top, supply and fixing of bakelite d.p / socket / switch with / without neon indicator over existing wood board or flush mounting in plastic / nitches as per is 1293 and is 3854 pg6 item 3.14 group a 3.14.11 16 amps three way 5 pin socket, supply and fixing of bakelite d.p / socket / switch with / without neon indicator over existing wood board or flush mounting in plastic / nitches as per is 1293 and is 3854 pg6 item 3.14 group a 3.14.10 16 amps two way switch, supply and fixing of bakelite d.p / socket / switch with / without neon indicator over existing wood board or flush mounting in plastic / nitches as per is 1293 and is 3854 pg6 item 3.14 group a 3.14.5 6 amps bakelite ceiling rose, supply and fixing of bakelite d.p / socket / switch with / without neon indicator over existing wood board or flush mounting in plastic / nitches as per is 1293 and is 3854 pg6 item 3.14 group a 3.14.6 6 amps lamp holder, supply and fixing of bakelite d.p / socket / switch with / without neon indicator over existing wood board or flush mounting in plastic / nitches as per is 1293 and is 3854 pg6 item 3.14 group a 3.14.7 6 amps bell push, supply and fixing of bakelite d.p / socket / switch with / without neon indicator over existing wood board or flush mounting in plastic / nitches as per is 1293 and is 3854 pg6 item 3.14 group a 3.14.7 6 amps bell buzzer, supplying 1 way plastic gang box and fixing using necessary wooden / rawl / phill plugs and screws pg 6 / 3.12.1, supplying 2 to 4 way plastic gang box and fixing using necessary wooden / rawl / phill plugs and screws pg 6 / 3.12.2, supplying 6 to 10 way plastic gang box and fixing using necessary wooden / rawl / phill plugs and screws pg 6 / 3.12.2, wiring for lighting / power circuit using one of frls pvc insulated 1100 v gradw multistrand copper with low conductor resistance single core in open or concealed system of wiring with specified is 694:1990 and conforming to gtp of group a pg / 2.3.2 2.3.2 1.5 sqmm, wiring for lighting / power circuit using one of frls pvc insulated 1100 v gradw multistrand copper with low conductor resistance single core in open or concealed system of wiring with specified is 694:1990 and conforming to gtp of group a pg / 2.3.3 2.3.3 2.5 sqmm, wiring for lighting / power circuit using one of frls pvc insulated 1100 v gradw multistrand copper with low conductor resistance single core in open or concealed system of wiring with specified is 694:1990 and conforming to gtp of group a pg 3 item sl no 2.3.4 2.3.4 4 sqmm, wiring for lighting / power circuit using one of frls pvc insulated 1100 v gradw multistrand copper with low conductor resistance single core in open or concealed system of wiring with specified is 694:1990 and conforming to gtp of group a pg 3 item sl no 2.3.5 2.3.5 6 sqmm, wiring for lighting / power circuit using one of frls pvc insulated 1100 v gradw multistrand copper with low conductor resistance single core in open or concealed system of wiring with specified is 694:1990 and conforming to gtp of group a pg 3 item sl no 2.3.6 2.3.6 10 sqmm, wiring for lighting / power circuit using one of frls pvc insulated 1100 v gradw multistrand copper with low conductor resistance single core in open or concealed system of wiring with specified is 694:1990 and conforming to gtp of group a pg 6 item sl no 2.5 2.5.7 16 sqmm, kptcl sr 22 23 pg 16 / 27ii testing , commissioning , wiring , identification & termination of wires , ferruling , crimping & termination of wires for annunciation etc, , , testing of relays , cts , pts & breakers for operation ii for single 11 kv panel ( indoor type ) , kptcl sr 22 23 / item 26ci testing & commissioning of c& r panels , wiring & testing , wiring of c& r panels , identification , ferruling , crimping , termination of wires in c & r panels , testing of relays , control operations for closing , tripping etc.. interlock alarm annunciation & indication checks, wiring for lighting / power circuit using one of frls pvc insulated 1100 v gradw multistrand copper with low conductor resistance single core in open or concealed system of wiring with specified is 694:1990 and conforming to gtp of group a 25 sqmm single core, wiring for lighting / power circuit using one of frls pvc insulated 1100 v gradw multistrand copper with low conductor resistance single core in open or concealed system of wiring with specified is 694:1990 and conforming to gtp of group a 50 sqmm single core, wiring for lighting / power circuit using one of frls pvc insulated 1100 v gradw multistrand copper with low conductor resistance single core in open or concealed system of wiring with specified is 694:1990 and conforming to gtp of group a pg 6 item sl no 2.5 100 sqmm single run, wiring for lighting / power circuit using one of frls pvc insulated 1100 v gradw multistrand copper with low conductor resistance single core in open or concealed system of wiring with specified is 694:1990 and conforming to gtp of group a pg 6 item sl no 2.5 150 sqmm single run, supplying capacitor type ceiling fan complete with down rod blades, shackle, canopies etc, for operation on 230 v, 50 cycles. single phase ac supply conforming to iss 374 1979 and with double ball bearing system. p22 / 6.3.1 6.3.1 48 sweep ( 1200 mm ) regular model, supplying capacitor type ceiling fan complete with down rod blades, shackle, canopies etc, for operation on 230 v, 50 cycles. single phase ac supply conforming to iss 374 1979 and with double ball bearing system. p 22 / 6.3.2 6.3.2 56 sweep ( 1400 mm ) regular model, fixing a ceiling fan / wall monting fan of all capacities and all types with necessary clamps and s” hook made out of 15mm dia ms rod with 5 amps ceiling rose of approved quality with necessary length of 23 / 0.0076” inch pvc insulated twin twisted wire od approved quality . mounted on a suitable size wooden board and wired pg 46 / 13.11 ( sr 22 23 ) , supplying of 1440 rpm heavy duty exhaust fan with bracket blades suitable to operate on 230 volts 50 hz ac supply pg 22 / 6.2.1 6.2.1 12” sweep ( 300mm ) , supplying of 1440 rpm heavy duty exhaust fan with bracket blades suitable to operate on 230 volts 50 hz ac supply pg 22 / 6.2.1 6.2.2 15” sweep ( 450mm ) , supplying of exhaust fan with bracket blades suitable to operate on 230 volts 50 hz ac upply pg 22 / 6.1, supplying of pedestal fan suitable to operate at single phase 230 volts ac supply p26 / 6.33.1 6.33.1 400 mm sweep, supplying of pedestal fan suitable to operate at single phase 230 volts ac supply p26 / 6.33.1 6.33.2 450 mm sweep, supplying wall mounting fan suitable to operate at single phase 230 volts ac supply pg 23 / 6.5.1 6.5.1 300mm sweep, supplying wall mounting fan suitable to operate at single phase 230 volts ac supply pg 23 / 6.5.1 6.5.2 400 mm sweep, fabricating supplying and mounting ms box made out … swg suitable for floor / wall mounting , fully weather proof with provision for better heat dissipation , provided with hinged front cover , equipped with tamper proof locking arrangements , with suitable size clamps with necessary cable entry pipe with gland and box should be finished with 2 coats of red oxide primer paint and finally finished with approved colour enameled metal paint etc.. complete pg 14 / 5.42 5.42.2 16 swg, supplying and fixing moulded circuit breaker ( mccb ) over existing wood panel board using necessary screws, bolts, nuts and wiring complete .protection of over load and short circuit with thermal magnetic / micrpprocessed release and earth fault as per ( is 13947 pg 12 item 5.14.7 four pole four pole 5.14.7 100 amps 25 ka, supplying and fixing moulded circuit breaker ( mccb ) over existing wood panel board using necessary screws, bolts, nuts and wiring complete .protection of over load and short circuit with thermal magnetic / micrpprocessed release and earth fault as per ( is 13947 pg 12 item 5.14.8 four pole four pole pwd sr 22 23 5.14.8 125 160 amps 25 ka, supplying and fixing moulded circuit breaker ( mccb ) over existing wood panel board using necessary screws, bolts, nuts and wiring complete .protection of over load and short circuit with thermal magnetic / micrpprocessed release and earth fault as per ( is 13947 pg 12 item 5.14.9 four pole four pole pwd sr 22 23 5.14.9 160 amps 25 ka, supplying and fixing moulded circuit breaker ( mccb ) over existing wood panel board using necessary screws, bolts, nuts and wiring complete .protection of over load and short circuit with thermal magnetic / micrpprocessed release and earth fault as per ( is 13947 pg 12 item 5.14.10 four pole four pole pwd sr 2022to 2023 5.14.10 200 amps 35 ka, supplying and fixing moulded circuit breaker ( mccb ) over existing wood panel board using necessary screws, bolts, nuts and wiring complete .protection of over load and short circuit with thermal magnetic / micrpprocessed release and earth fault as per ( is 13947 pg 12 item 5.14.11 four pole 5.14.11 250 amps 35 ka, supplying and fixing moulded circuit breaker ( mccb ) over existing wood panel board using necessary screws, bolts, nuts and wiring complete .protection of over load and short circuit with thermal magnetic / micrpprocessed release and earth fault as per ( is 13947 pg 12 item 5.14.2 four pole 5.14.12 320 400 amps 50 ka, supplying and fixing moulded circuit breaker ( mccb ) over existing wood panel board using necessary screws, bolts, nuts and wiring complete .protection of over load and short circuit with thermal magnetic / micrpprocessed release and earth fault as per ( is 13947 pg 12 item 5.14.13 four pole 5.14.13 400 500 amps 50 ka, supplying and fixing moulded circuit breaker ( mccb ) over existing wood panel board using necessary screws, bolts, nuts and wiring complete .protection of over load and short circuit with thermal magnetic / micrpprocessed release and earth fault as per ( is 13947 pg 12 item 5.14.14 four pole 5.14.14 500 630 amps 50 ka, supplying and fixing moulded circuit breaker ( mccb ) over existing wood panel board using necessary screws, bolts, nuts and wiring complete .protection of over load and short circuit with thermal magnetic / micrpprocessed release and earth fault as per ( is 13947 pg 12 item 5.14.15 four pole 5.14.15 700 800 amps 50 ka, supplying and fixing of air circuit breakers 4pole ( acb.s ) manual operable make :l&t, c&s . schenider or abb, supplying and fixing of 1 od for rmu ( vcb, s ) 630 amps , bescom sr 21 22 pg 11 item 39.05, supplying and fixing of 1 vl for rmu, 630 amps bescom sr 21 22 pg 11 / 39.06, bescom sr 22 23 pg 18 item 58.04 lt metering box for housing the etv meter without cts busbar wiring etc.. bescom sr 22 23 pg 18 item 58.04, cleaning of ht yard by removing the vegetation, providing painting for ht substation ( alluminium painting including all labour charges, providing painting for 500 kva transformers, providing painting of lt distribution boards ( spray painting ) , filtering of oil in the transformer 500 kva at the transformer centre by hot process using steam line filter “ such time the dielectric strength of the oil in the transformer conforms to isi specifications ( test certificates to produced ) ( each 500 kva transformer approximately 380 litres and refilling may be required 30 to 50 litres, supplying and filling fresh silica gel to the breathe of the transformers, providing alluminium painting for the structures & the dg set exhaust pipes 8 inches for height 30 mtrs including materials and labour charges ( 4nos ) , filtering of oil in the transformer 1000 kva at the transformer centre by hot process using steam line filter “ such time the dielectric strength of the oil in the transformer conforms to isi specifications ( test certificates to produced ) ( each 500 kva transformer approximately 380 litres and refilling may be required 30 to 50 litres, supplying and filling fresh silica gel to the breathe of the transformers, supplying and fixing of 25mm dia 2mm wall thickness 15 kv class alkathine pipe to bus bar leads etc.. at substation, supplying and topping of oil for di electric strength ( bdv ) acidity transformer oil as per is 335:1993 bescom sr 21 21 pg 5 item 15.01, supplying and filling fresh silica gel to the breathe of the transformers, providing megger test for the earth pits at the electrical substation, supplying and fixing of nuts and bolts for the earth pits at the electrical substation and other areas., good quality well burnt out charcoal for grounding purposes packed in 30 kgs gunny bag bescom sr 21 22 sl no 440 item 54.02, good quality salt for grounding purposes packed in 50 kgs gunny bag bescom sr 21 22 sl no 441 item no: 54.03, re construction of earth pit chambers , labelling and covering the earth pits with cast iron cover 400x400x400 mm, providing calibration services for all the energy metres / ct, s of dg sets, providing megger test results for the damaged cables to detect the damage of lt cable, providing megger test results for the damaged cables to detect the damage of ht ug cable, submission of compliance report to electrical inspectorate against the observations made by the electrical inspectorate ( except statutory fees ) , providing re winding for copper wound transformer including releasing and re fixing with all lead and lift including providing crane services and providing megger test etc.., supplying of 5 hp submersible pump motrs ( 2nos ) kirloskar make / atlanta / texmo with a delivery point is about 30 mtrs height for dharmasahala pump house including supplying and fixing automatic starter panel with selctor switch type change over so that one motor shall operate at a time including supplying and drawing 2 .5 inch cpvc pipe , automatic starter control panel , mccb 100 amps and mcb 3 ploe 32 amps and contactor 40 amps and plumbimg works incuding supplying and fixing of non return vales 4nos of 50mm and gate valves of heavy duty 2nos ) of required size etc.. with a automatic water controller facility by supplying and drawing ofc cable of about 175 for providing water supply to ot block, providing booster pump for the ro 500 lph plant including material and labour charges, supplying of 10 hp submersible pump motrs ( 2nos ) kirloskar make / atlanta / texmo with adelivery point is about 30 mtrs height for dharmasahala pump house including supplying and fixing automatic starter panel with selctor switch type change over so that one motor shall operate at a time including supplying and drawing 2 .5 inch cpvc pipe , automatic starter control panel , mccb 100 amps and mcb 3 ploe 32 amps and contactor 40 amps and plumbimg works incuding supplying and fixing of non return vales 4nos of 65mm and gate valves of heavy duty 2nos ) of required size etc.., supplying fixing and wiring earth electrode for grounding of lifts transformers , dg sets etc.. using 40mm dia 2.9 mm thick 2.5 mtr long gi pipe with gi funnel with mesh and suitable size reducer fixed on the top of the earth electrode .the funnel should be enclosed in a cc chamber of 400x 400x 400mm with a cast iron cover .the earth electrode shall have staggered holes of 12mm dia and the electrode should be covered 150mm alround with alternate layers of salt and charcoal from the bottom of the cc chamber.the connection from the electrode is to be established through gi strip using gi bolts and nuts pg 55 item 7.2, supplying and running of gi / copper strips for grounding connections, using `1necessary fixing materials as required pg 55 item 7.3 gi strip 7.3.1 25 x3mm, supplying and running of gi / copper strips for grounding connections, using `1necessary fixing materials as required pg 55 item 7.3 gi strip 7.3.2 25 x6mm, supplying and running of gi / copper strips for grounding connections, using `1necessary fixing materials as required pg 55 item 7.3 gi strip 7.3.3 40 x6mm, supplying and running of gi / copper strips for grounding connections, using `1necessary fixing materials as required pg 55 item 7.3 gi strip 7.3.5 600x600x3mm gi plate, supplying and running of gi / copper strips for grounding connections, using `1necessary fixing materials as required pg 55 item 7.3 copper strip 7.3.6 25 x3mm, supplying and running of gi / copper strips for grounding connections, using `1necessary fixing materials as required pg 55 item 7.3 copper strip 7.3.7 25 x6mm, supplying and running of gi / copper strips for grounding connections, using `1necessary fixing materials as required pg 55 item 7.3 copper strip 7.933.8 40 x6mm, supplying and running of gi / copper strips for grounding connections, using `1necessary fixing materials as required pg 55 item 7.3 copper strip 7.3.10 600x600x3mm plate, supplying of 1.1 kv lt ug cable having aluminium conductor pvc insulated, extruded inner sheathed sheathed, galvanised , strips ( except 2cx10 sqmm wire armoured ) asper is 3975:1990 & extruded pvcouter sheathed armoured cable as per is 1554 pare 1:1998 & confirming to gtp of group –a pg 9 / item 32 of bescom sr 21 22 32.01 6 sqmm, 2 core ( 24 gi wire 1.4mm ) , supplying of 1.1 kv lt ug cable having aluminium conductor pvc insulated, extruded inner sheathed sheathed, galvanised , strips ( except 2cx10 sqmm wire armoured ) asper is 3975:1990 & extruded pvcouter sheathed armoured cable as per is 1554 pare 1:1998 & confirming to gtp of group –a pg 9 / item 32 of bescom sr 21 22 23.02 10 sqmm 2core ( ( gi strips 4x0.8mm ) , supplying of 1.1 kv lt ug cable having aluminium conductor pvc insulated, extruded inner sheathed sheathed, galvanised , strips ( except 2cx10 sqmm wire armoured ) asper is 3975:1990 & extruded pvcouter sheathed armoured cable as per is 1554 pare 1:1998 & confirming to gtp of group –a pg 9 / item 32 of bescom sr 21 22 32.03 10 sqmm 4 core ( 10 gi strips 4x0.8mm ) , supplying of 1.1 kv lt ug cable having aluminium conductor pvc insulated, extruded inner sheathed sheathed, galvanised , strips ( except 2cx10 sqmm wire armoured ) asper is 3975:1990 & extruded pvcouter sheathed armoured cable as per is 1554 pare 1:1998 & confirming to gtp of group –a pg 9 / item 32 of bescom sr 21 22 32.05 16 sqmm , 4 core ( 11 gi strips 4x0.8mm ) , supplying of 1.1 kv lt ug cable having aluminium conductor pvc insulated, extruded inner sheathed sheathed, galvanised , strips ( except 2cx10 sqmm wire armoured ) asper is 3975:1990 & extruded pvcouter sheathed armoured cable as per is 1554 pare 1:1998 & confirming to gtp of group –a pg 9 / item 32 of bescom sr 21 22 32.07 3.5 core 25 sqmm ( 12 gi strips 4x0.8mm ) , supplying of 1.1 kv lt ug cable having aluminium conductor pvc insulated, extruded inner sheathed sheathed, galvanised , strips ( except 2cx10 sqmm wire armoured ) asper is 3975:1990 & extruded pvcouter sheathed armoured cable as per is 1554 pare 1:1998 & confirming to gtp of group –a a pg 9 / item 32 of bescom sr 21 22 32.09 3.5 core 35 sqmm, supplying of 1.1 kv lt ug cable having aluminium conductor pvc insulated, extruded inner sheathed sheathed, galvanised , strips ( except 2cx10 sqmm wire armoured ) asper is 3975:1990 & extruded pvcouter sheathed armoured cable as per is 1554 pare 1:1998 & confirming to gtp of group –a pg 9 / item 32 of bescom sr 21 22 32.11 3.5 core 50 sqmm, supplying of 1.1 kv lt ug cable having aluminium conductor pvc insulated, extruded inner sheathed sheathed, galvanised , strips ( except 2cx10 sqmm wire armoured ) asper is 3975:1990 & extruded pvcouter sheathed armoured cable as per is 1554 pare 1:1998 & confirming to gtp of group –a pg 9 / item 32 of bescom sr 21 22 32.12 4 core 50 sqmm, supplying of 1.1 kv lt ug cable having aluminium conductor pvc insulated, extruded inner sheathed sheathed, galvanised , strips ( except 2cx10 sqmm wire armoured ) asper is 3975:1990 & extruded pvcouter sheathed armoured cable as per is 1554 pare 1:1998 & confirming to gtp of group –a pg 9 / item 32 of bescom sr 21 22 32.13 70 sqmm 3.5 core, supplying of 1.1 kv lt ug cable having aluminium conductor pvc insulated, extruded inner sheathed sheathed, galvanised , strips ( except 2cx10 sqmm wire armoured ) asper is 3975:1990 & extruded pvcouter sheathed armoured cable as per is 1554 pare 1:1998 & confirming to gtp of group –a pg 9 / item 32 of bescom sr 21 22 32.14 95 sqmm 3, 5 core, supplying of 1.1 kv lt ug cable having aluminium conductor pvc insulated, extruded inner sheathed sheathed, galvanised , strips ( except 2cx10 sqmm wire armoured ) asper is 3975:1990 & extruded pvcouter sheathed armoured cable as per is 1554 pare 1:1998 & confirming to gtp of group –a pg 9 / item 32 of bescom sr 21 22 32.15 3.5 core 120 sqmm, supplying of 1.1 kv lt ug cable having aluminium conductor pvc insulated, extruded inner sheathed sheathed, galvanised , strips ( except 2cx10 sqmm wire armoured ) asper is 3975:1990 & extruded pvcouter sheathed armoured cable as per is 1554 pare 1:1998 & confirming to gtp of group –a pg 9 / item 32 of bescom sr 21 22 32.16 3.5 core 150 sqmm, supplying of 1.1 kv lt ug cable having aluminium conductor pvc insulated, extruded inner sheathed sheathed, galvanised , strips ( except 2cx10 sqmm wire armoured ) asper is 3975:1990 & extruded pvcouter sheathed armoured cable as per is 1554 pare 1:1998 & confirming to gtp of group –a a pg 9 / item 32 of bescom sr 21 22 32.17 3.5 core 185 sqmm, supplying of 1.1 kv lt ug cable having aluminium conductor pvc insulated, extruded inner sheathed sheathed, galvanised , strips ( except 2cx10 sqmm wire armoured ) asper is 3975:1990 & extruded pvcouter sheathed armoured cable as per is 1554 pare 1:1998 & confirming to gtp of group –a a pg 9 / item 32 of bescom sr 21 22 32.18 3.5 core 240 sqmm, supplying of 1.1 kv lt ug cable having aluminium conductor pvc insulated, extruded inner sheathed sheathed, galvanised , strips ( except 2cx10 sqmm wire armoured ) asper is 3975:1990 & extruded pvc outer sheathed armoured cable as per is 1554 pare 1:1998 & confirming to gtp of group –a pg 9 / item 32 of bescom sr 21 22 32.19 3.5 core 300 sqmm, supplying of 1.1 kv lt ug cable having aluminium conductor pvc insulated, extruded inner sheathed sheathed, galvanised , strips ( except 2cx10 sqmm wire armoured ) asper is 3975:1990 & extruded pvcouter sheathed armoured cable as per is 1554 pare 1:1998 & confirming to gtp of group –a pg 9 / item 32 of bescom sr 21 22 32.20 3.5 core 400 sqmm, labour charges for laying of upto 95 sqmm lt ug cable bescom sr 21 22 pg 4, labour charges for laying of 120 sqmm lt ug cable bescom sr 21 22 pg 4, labour charges for laying of 150 sqmm lt ug cable bescom sr 21 22 pg 4, labour charges for laying of 185 sqmm lt ug cable bescom sr 21 22 pg 4, labour charges for laying of 240 sqmm lt ug cable bescom sr 21 22 pg 4, labour charges for laying of 300 sqmm lt ug cable bescom sr 21 22 pg 4, labour charges for laying of 400 sqmm lt ug cable bescom sr 21 22 pg 4, laying of cable in existing trench / gi pipe / stone ware / rcc hume pipe using wooden / aluminum rollers as directed by the departmental staff lt cable ( page no. 09 item no. 39 ) bescom sr sl no. 230 ) 31.05 ) 2.5 to 25 sqmm, laying of cable in existing trench / gi pipe / stone ware / rcc hume pipe using wooden / aluminum rollers as directed by the departmental staff lt cable ( page no. 09 item no. 39 ) bescom sr sl no. 231 ) 31.06 ) 35 to 95 sqmm, laying of cable in existing trench / gi pipe / stone ware / rcc hume pipe using wooden / aluminum rollers as directed by the departmental staff lt cable ( page no. 09 item no. 39 ) bescom sr sl no. 231 ) 31.07 ) 120 to 240 sqmm, laying of cables in existing trench / gi pipe / stone ware / rcc hume pipe using wooden / alluminium rollers as directed by the dept staff bescom sr 21 22 sl no: 225 pg no 9 item no: 31 31.01 3x95 sqmm to 150 sqmm, laying of cables in existing trench / gi pipe / stone ware / rcc hume pipe using wooden / alluminium rollers as directed by the dept staff bescom sr 21 22 sl no: 225 pg no 9 item no: 31 31.02 3x185 sqmm to 240 sqmm, supplying and drawing 3 core flat pvc sheathed submersible pump manufactured with electrolytic grade flexible copper with low conductor confirming to table 3 class of is :13:8130 1984 and virgin grade pvc insulation and powder coating pvc extruded pvc sheathed suitable for working voltage up to 1100volts as per is 694:2010 pwd sr 22 23 pg 4 item 2.5.2 2.5.2 3 core x 1.5 sqmm, supplying and drawing flexible multicore cable manufactured with electrolytic grade flexible copper with low conductor confirming to table 3 class of is :8310 1984 and ( virgin ) pvc insulation and sheathed suitable voltage up to 1100volts as per is 694:1990 pwd sr 22 23 pg 4 item 2.5.2 2.5.3 4 core x 1.5 sqmm, supplying and drawing flexible multicore cable manufactured with electrolytic grade flexible copper with low conductor confirming to table 3 class of is :8310 1984 and ( virgin ) pvc insulation and sheathed suitable voltage up to 1100volts as per is 694: 2.5.9 pwd sr 22 23 pg 4 item 2.5.9 2.5. 9 4 core x 2.5 sqmm, supplying and drawing flexible multicore cable manufactured with electrolytic grade flexible copper with low conductor confirming to table 3 class of is :8310 1984 and ( virgin ) pvc insulation and sheathed suitable voltage up to 1100volts as per is 694: pwd sr 22 23 pg 4 item 2.5.16 2.5.16 4 core x 4 sqmm, supplying and drawing flexible multicore cable manufactured with electrolytic grade flexible copper with low conductor confirming to table 3 class of is :8310 1984 and ( virgin ) pvc insulation and sheathed suitable voltage up to 1100volts as per is 694:1990 pwd sr 22 23 pg 4 item 2.5.16 2.5.11 6 core x 1.5 sqmm, supplying and drawing 3 core flat pvc sheathed submersible pump cable manufactured with electrolytic grade flexible copper with low conductor confirming to table 3 class of is :8310 1984 and ( virgin ) pvc insulation and sheathed suitable voltage up to 1100volts as per is 694:1990 pwd sr 22 23 pg 4 item 2.6.6 2.6.2 3core 2.5 sqmm, supplying and drawing flexible multicore cable manufactured with electrolytic grade flexible copper with low conductor confirming to table 3 class of is :8310 1984 and ( virgin ) pvc insulation and sheathed suitable voltage up to 1100volts as per is 694:1990 & conforming to gtp of group a item 2.8 pg no 8 2.6.3 3core x 4sq mm, labour charges for laying of 1.1 kv class ug cable in existing trench gi pipe / stone ware pipe / on wall / on pole as required pwd sr 19 20 pg 41 item 6.5.1 in existing trench / duct 6.5.1 6 sqmm to 16 sqmm, labour charges for laying of 1.1 kv class ug cable in existing trench gi pipe / stone ware pipe / on wall / on pole as required . pwd sr 19 20 pg 41 item 6.5.2 in existing trench / duct 6.5.2 25 sqmm to 75 sqmm, labour charges for laying of 1.1 kv class ug cable in existing trench gi pipe / stone ware pipe / on wall / on pole as required . pwd sr 19 20 pg 41 item 6.5.3 in existing trench / duct6.5.3 95 sqmm to 150 sqmm, labour charges for laying of 1.1 kv class ug cable in existing trench gi pipe / stone ware pipe / on wall / on pole as required. pwd sr 19 20 pg 41 item 6.5.4 in existing trench / duct6.5.4 185 sqmm to 240 sqmm, labour charges for laying of 1.1 kv class ug cable in existing trench gi pipe / stone ware pipe / on wall / on pole as required . pwd sr 19 20 pg 41 item 6.5.5 in existing trench / duct 6.5.5 300 sqmm to 400 sqmm, labour charges for laying of 1.1 kv class ug cable in existing trenchgi pipe / stone ware pipe / on wall / on pole as required . pwd sr 19 20 pg 41 item 6.5.6 on wall / structure 6.5.6 6 sqmm to 16 sqmm, labour charges for laying of 1.1 kv class ug cable in existing trenchgi pipe / stone ware pipe / on wall / on pole as required . pwd sr 19 20 pg 41 item 6.5.7 on wall / structure 6.5.7 25 sqmm to 75sqmm, labour charges for laying of 1.1 kv class ug cable in existing trenchgi pipe / stone ware pipe / on wall / on pole as required. pwd sr 19 20 pg 41 item 6.5.8 on wall / structure 6.5.8 95 sqmm to 150sqmm, labour charges for laying of 1.1 kv class ug cable in existing trenchgi pipe / stone ware pipe / on wall / on pole as required . pwd sr 19 20 pg 41 item 6.5.9 on wall / structure 6.5.9 185 sqmm to 240 sqmm, labour charges for laying of 1.1 kv class ug cable in existing trenchgi pipe / stone ware pipe / on wall / on pole as required . pwd sr 19 20 pg 41 item 6.5.10 on wall / structure 6.5.10 300 sqmm to 400 sqmm, earth work excavation for cable trench of 0.5 to 0.75 mtr width and depth upto 1 mtr including trial pits , depositing on bank upto a lead 50 mtrs, supplying and displaying necessary danger boards and lighting, using sight rails and sign boards at every 100 mtrs wherever necessary as directed ( bescom sr 21 22 pg 8 item 29.02 ( added 30 % special locality allowance ) 29.02 in ordinary soil, earth work excavation for cable trench of 0.5 to 0.75 mtr width and depth upto 1 mtr including trial pits , depositing on bank upto a lead 50 mtrs, supplying and displaying necessary danger boards and lighting, using sight rails and sign boards at every 100 mtrs wherever necessary as directed ( bescom sr 21 22 pg 8 item 29.03 ( added 30 % special locality allowance ) 29.03 in hard soil, earth work excavation for cable trench of 0.5 to 0.75 mtr width and depth upto 1 mtr including trial pits , depositing on bank upto a lead 50 mtrs, supplying and displaying necessary danger boards and lighting, using sight rails and sign boards at every 100 mtrs wherever necessary as directed ( bescom sr ) in hard rock / latterite rock, latterite soil, refilling the trenches with selected available earth from the trenchexcavation including watering, consolidation in layers of 15cmthickness including deposition of surplus earth with lead of 200 mtrs ( bescom sr ) pg 8 / 29.07, cutting the road surface for cable trenches and disposing of the excavated earth, as directed including barricading, danger lighting then refilling the cable trenches ( bescom sr ) pg 8 / 29.09 macadam road, cutting the road surface for cable trenches and disposing of the excavated earth, as directed including barricading, danger lighting then refilling the cable trenches ( bescom sr ) tar road pg 8 / 29.10, cutting the road surface for cable trenches and disposing of the excavated earth, as directed including barricading, danger lighting then refilling the cable trenches ( bescom sr ) cement concrete road, ksrb 4 1.3 providing and laying in position plain cement concrete of mix 1:4:8 with opc cement @ 180kgs, with 40mm and down size graded metal coarse aggregate @0.85cum and fine aggregates @0.57cum machine mixed, concrete laid in layers not exceeding 15cms. thick well compacted in foundation including cost of all materials, labour hom of machinery curing complete as per specifications kbs 4.1 , 4.2 ( bescom sr 22 23 ) pg 9 / 33.08, ksrb 4 1.3: providing and laying in position plane cement concrete of mix1:2:4 with cement @240kgs with 20mm and down size graded granite metal coarse aggregates @ 0.878cmt and fine aggregates @ 0.459 cmt machine moixed concrete laid in layers not exceeding 15 cm, thick well compacted , in foundation and plinth and cills including coost of all materials , labour , hom of machinery, curing complete as per specifications , specification no kbs 4.1 4.2 bescom sr 22 23 pg 9 / 33.09, providing painting two coats for the lt distribution panel boards including cleaning inside the entire panel bard and including one coat of primer as per the directions of the engineer in charge and the existing color only including fixing of danger boards, spreading of 40mm stone jelly including materials and labour charges, supplying tinned copper lugs and crimping and wiring to terminal point of wire of the following sizes pg 43 sr 19 20 item 6.17.3 4 sqmm, supplying tinned copper lugs and crimping and wiring to terminal point of wire of the following sizes pg 43 sr 19 20 item 6.17.4 6sqmm, supplying tinned copper lugs and crimping and wiring to terminal point of wire of the following sizes pg 43 sr 19 20 item 6.17.5 6.17.5 10 sqmm, supplying tinned copper lugs and crimping and wiring to terminal point of wire of the following sizes pg 43 sr 19 20 item 6.17.6 6.17.6 16 sqmm, supplying tinned copper lugs and crimping and wiring to terminal point of wire of the following sizes pg 43 sr 19 20 item 6.17.7 6.17.7 25 sqmm long barrel, supplying tinned copper lugs and crimping and wiring to terminal point of wire of the following sizes pg 43 sr 19 20 item 6.17.8 6.17.8 35 sqmm long barrele, supplying tinned copper lugs and crimping and wiring to terminal point of wire of the following sizes pg 43 sr 19 20 item 6.17.9 6.17.9 50 sqmm long barrel, supplying tinned copper lugs and crimping and wiring to terminal point of wire of the following sizes pg 43 sr 19 20 item 6.17.10 6.17.10 70 sqmm long barrel, supplying tinned copper lugs and crimping and wiring to terminal point of wire of the following sizes pg 43 sr 19 20 item 6.17.11 6.17.11 95 sqmm long barrel, supplying tinned copper lugs and crimping and wiring to terminal point of wire of the following sizes pg 43 sr 19 20item 6.17.12 6.17.12 120 sqmm long barrel, supplying tinned copper lugs and crimping and wiring to terminal point of wire of the following sizes pg 43 item 6.17.13 6.17.13 150 sqmm long barrel, supplying tinned copper lugs and crimping and wiring to terminal point of wire of the following sizes pg 43 item 6.17.14 185 sqmm long barrel, supplying tinned copper lugs and crimping and wiring to terminal point of wire of the following sizes pg 43 item 6.17.15 240 sqmm long barrel, supplying tinned copper lugs and crimping and wiring to terminal point of wire of the following sizes pg 43 sr 19 20 item 6.17.16 300 sqmm long barrel, supplying tinned copper lugs and crimping and wiring to terminal point of wire of the following sizes pg 43 sr 19 20 item 6.17.17 6.17.17 400 sqmm long barrel, supplying and running gi / copper conductor for grounding and ( along with other wires in conduit system of wiring ) using necessary suitable clamps , nails , guttas / spacers etc.. pg 43 sr 19 20 item 6.18.3 8 swg gi wire, fixing a ceiling / wall mounting fan of all capacities and all types to the existing shook with fan regulator to the existing board together with supplying and fixing a 5 amperes ceiling rose , necessary length of 23 / 0.0076” inch pvc insulated twin twisted copper wire and wiring pg 48 item13.10 pwd sr 22 23, extra length of gi pipe of class b 19mm dia for down rod pg 46 item 13.12, fixing a ceiling / wall mounting fan of all capacities and all types with necessary clamps and “ s “ hook made out of 15mm dia ms rod , with 5 amps ceiling rose of approved quality with necessary length of 23 / 0.0076 inch pvc insulated twin twisted wire of approved quality. mounted on suitable size and wired pg 48 item 13.11 pwd sr 22 23, supplying exhaust fan of 1440 rpm of 300mm ( 12’ ) heavy duty exhaust fan with bracket blades suitable to operate on 230 volts 50 hz ac supply complete pg 22 sr 22 23 item 6.2.1 6.2.1 12” sweep ( 300mm ) , supplying exhaust fan of 1440 rpm of 300mm ( 12’ ) heavy duty exhaust fan with bracket blades suitable to operate on 230 volts 50 hz ac supply complete pg 22 sr 22 23 item 6.2.2 6.2.2 15” sweep ( 450mm ) , fixing one exhaust fan after making a suitable nitch in the wall and finishing with cement morter and colouring to match the existing wall or brackets with bolts and nuts and a 5 amps ceiling rose with sufficient length of 23 / 0.0076 inch pvc insulated twin core wire of approved make with wire mesh amd wooden frame pg 46 item 13.13, fixing all types and all capacities of 1x4’ / 2’x2’ led light fittings on the wall / ceiling / rafters / girders with necessary supporting frame , using 23 / 0.0076 inch twin twisted pvc insulated wires , required nos of round block pg 47 / 13.19 pwd sr 22 23, supplying of 2 tr capacity window type air conditioner conforming to is specifications , suitable for operation on 230 volts , 50 hz single phase ac supply with all accessories . pg 23 / 6.6.3 6.6.3 2 tr capacity 5 star rated make : blue star / diakin / mitsubhishi, supplying of 5 star 1 ton capacity split type air conditioner confirming to is specification suitable for operation on 230 volts , 50 hz ac supply with all accessories pg 24 item 6.8.4 sr 22 23 6.8.4 1 ton capacity 5 star rated invertor make : blue star / diakin / mitsubhishi, supplying of 5 star 1 ton capacity window type air conditioner confirming to is specification suitable for operation on 230 volts , 50 hz ac supply with all accessories pg 24 item 6.8.5 sr 22 23 6.8.5 1.5 ton capacity 5 star rated invertor make : blue star / diakin / mitsubhishi, supplying of 5 star rated 2 tr split air conditioner suitable for operation on ac supply single phase 50 hz 230 volts with hermitically sealed compressor with air cooled condenser, motor capacitor and start run capacitors, relay and over load protector internal unit. with one indoor and one out door unit .the condenser unit will be placed outside the room on the terrace to avoid the noise including standard length of suitable size copper tubing covered with insulation tube . ( high wall chorded / chordless ) pg 24 item 6.8.6 sr 22 23 6.8.6 2 ton capacity 5 star rated make : blue star / diakin / mitsubhishi, supply erection, testing, commissioning of cassette type split air conditioners suitable for operation on single / three phase ac supply, hermetically sealed compressor with air cooled condenser motor capacitor start, capacitors run relay and over load protection, one ceiling mounted indoor unit and one outdoor condenser unit including standard accessories covered with insulation tube including battery operated cordless unit pg 24 / item 6.9.3 sr 22 23 6.9.3 2 tr cassette single phase make : blue star / diakin / mitsubhishi, supply erection, testing, commissioning of cassette type split air conditioners suitable for operation on single / three phase ac supply, hermetically sealed compressor with air cooled condenser motor capacitor start, capacitors run relay and over load protection, one ceiling mounted indoor unit and one outdoor condenser unit including standard accessories covered with insulation tube including battery operated cordless unit pg 24 / item 6.9.4 sr 22 23 6.9.4 3 tr cassette three phase make : blue star / diakin / mitsubhishi, supply erection, testing, commissioning of cassette type split air conditioners suitable for operation on single / three phase ac supply, hermetically sealed compressor with air cooled condenser motor capacitor start, capacitors run relay and over load protection, one ceiling mounted indoor unit and one outdoor condenser unit including standard accessories covered with insulation tube including battery operated cordless unit pg 24 / item 6.9.5 sr 22 23 6.9.5 4 tr cassette three phase make : blue star / diakin / mitsubhishi, installation charges for 1 to 2ton capacity window type air conditioners with 50x75 thick teak wood frame of suitable size and allied works complete pg 24 item 6.12 sr 22 23, installation charges for split type air conditioners with allied works for one indoor and one outdoor unit is to be mounted on suitable angle iron support upto 3.0 ton split / cassette type a / c pg 24 item 6.12 sr 22 23, supplying and fixing of insulated refrigrent copper tubing of 5 / 8’’ and 3 / 8’’ with polythene foam insulation 3 core 80 strands copper wiring between indoor and outdoor unit.leak testing of oil and gas charging for additional piping length of tube pg 25 item 6.13.1 sr 22 23 6.13.1 split, supplying and fixing of insulated refrigrent copper tubing of 5 / 8’’ and 3 / 8’’ with polythene foam insulation 3 core 80 strands copper wiring between indoor and outdoor unit.leak testing of oil and gas charging for additional piping length of tube pg 25 item 6.13.1 sr 22 23 6.13.2 cassette, supplying and refilling refrigerant ( f 22 / f 12 ) for air conditioning equipment including labour and nitrogen gas for pressure and leak testing pg 80 item 9.17, supplying and refilling refrigerant ( r 32 / r 410a ) for air conditioning equipment including labour and nitrogen gas for pressure and leak testing, extra for fabrication supply and fixing of standard fabricated using slotted angel / l angel of size 6mmx50mm for mounting out door / indoor a.c.unit / batteries pg 25 item 6.22 sr 22 23, supplying and fixing capacitors of approved make for window / split air conditioners pg 25 item 6.16.1 6.16.1 25 to 45 mfd running capacitor sr 22 23, supplying and fixing capacitors of approved make for window / split air conditioners pg 80 item 9.14 6.16.2 80 to 200 mfd starting capacitor sr 22 23, supplying and installation , testing and commissioning of heavy duty compressor suitable foe window / split type ac pg 25 item 6.14.1 sr 22 23 6.14.1 1 ton capacity, supplying and installation , testing and commissioning of heavy duty compressor suitable for window / split type ac pg 25 item 6.14.2 sr 22 23 6.14.2 1.5 to 2ton capacity, supplying and installation , testing and commissioning of heavy duty compressor suitable foe window / split type ac pg 25 item 6.14.3 sr 22 23 6.14.3 3 ton capacity, supply and fixing of in door unit complete with condensing coil, blower, fan etc., complete suitable for split air conditioners. pg 26 / item 6.43.1 6.34.1 1 ton capacity, supply and fixing of in door unit complete with condensing coil, blower, fan etc., complete suitable for split air conditioners pg26 / item 6.34.2 6.34.2 1.5 ton capacity no new item 22209.00, supply and fixing of in door unit complete with condensing coil, blower, fan etc., complete suitable for split air conditioners pg 26 / item 6.34.3 6.34.3 2 ton capacity, supply and fixing of out door condensing unit complete with condensing coil, blower, fan etc., complete suitable for split air conditioners pg 25 / item 6.23.1 6.23.1 1 ton capacity, supply and fixing of out door condensing unit complete with condensing coil, blower, fan etc., complete suitable for split air conditioners pg 25 / item 6.23.2 6.23.2 1.5 ton capacity, supply and fixing of out door condensing unit complete with condensing coil, blower, fan etc., complete suitable for split air conditioners pg 25 / item 6.23.2 6.23.3 2 ton capacity, supplying and drawing of 5 / 8” and 7 / 8” hard drawn refrigerant pipe and insulation suitable for 11tr ductable split air conditioner pg 25 / 6.24, providing cleaning for the gi ducting line along with flanges , supports & all fixing materials once in a month including labour charges, providing cleaning for inside and outside the 60 / 80 kva ups / amf panel ups at least once in a three months by using blower / vaccum cleaner, supplying and commisioning of ac remote for cassette / package type ductable, supply of led streetlight luminaire with pressure die cast aluminium housing body for optimal thermal dissipation. lamp compartment comprising of anti glare clear diffuser with injection moulded polycarbonate material, delivering superior light output rated life burning hrs 50000 hr @ lumen maintenance of 70%, maximum light intensity should be between 60 degrees to 70 degrees. cct > 5500k, ip66 optical and electrical compartment & impact resistance of complete luminaire > ik08. power factor >0.9 with mains, surge protection min 5kv along with over voltage / overload, short circuit / miss wiring protection. compatible for pole mounting with outer dia of 40mm to 50mm. universal voltage driver to operate wide voltage range from 100v to 270v 50 / 60hz application. compliance to is 10322 / iec 60598, lm 79 & lm 80 adherence with rohs. ul approved mcpcb. top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools. led light fixture with ........w system power consumption. led efficiency>1301m / w, nominal cri >75. luminaire manufacturer should have in house facility accredited by nabl / cpri & any government certified agency & design & development facility certified by iso 9001:2008. housing with supplier word mark / name shall be engraved / embossing on the die cast housing / body part. warranty of 2 years against any manufacturing defect working under standard electrical conditions as mentioned pg 36 / 11.8.5 11.8.5 led street lights 120 watts, supply of led streetlight luminaire with pressure die cast aluminium housing body for optimal thermal dissipation. lamp compartment comprising of anti glare clear diffuser with injection moulded polycarbonate material, delivering superior light output rated life burning hrs 50000 hr @ lumen maintenance of 70%, maximum light intensity should be between 60 degrees to 70 degrees. cct > 5500k, ip66 optical and electrical compartment & impact resistance of complete luminaire > ik08. power factor >0.9 with mains, surge protection min 5kv along with over voltage / overload, short circuit / miss wiring protection. compatible for pole mounting with outer dia of 40mm to 50mm. universal voltage driver to operate wide voltage range from 100v to 270v 50 / 60hz application. compliance to is 10322 / iec 60598, lm 79 & lm 80 adherence with rohs. ul approved mcpcb. top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools. led light fixture with ........w system power consumption. led efficiency>1301m / w, nominal cri >75. luminaire manufacturer should have in house facility accredited by nabl / cpri & any government certified agency & design & development facility certified by iso 9001:2008. housing with supplier word mark / name shall be engraved / embossing on the die cast housing / body part. warranty of 2 years against any manufacturing defect working under standard electrical conditions as mentioned pg 36 / 11.8.6 11.8.6 led street lights 150 watts, supply of led streetlight luminaire with pressure die cast aluminium housing body for optimal thermal dissipation. lamp compartment comprising of anti glare clear diffuser with injection moulded polycarbonate material, delivering superior light output rated life burning hrs 50000 hr @ lumen maintenance of 70%, maximum light intensity should be between 60 degrees to 70 degrees. cct > 5500k, ip66 optical and electrical compartment & impact resistance of complete luminaire > ik08. power factor >0.9 with mains, surge protection min 5kv along with over voltage / overload, short circuit / miss wiring protection. compatible for pole mounting with outer dia of 40mm to 50mm. universal voltage driver to operate wide voltage range from 100v to 270v 50 / 60hz application. compliance to is 10322 / iec 60598, lm 79 & lm 80 adherence with rohs. ul approved mcpcb. top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools. led light fixture with ........w system power consumption. led efficiency>1301m / w, nominal cri >75. luminaire manufacturer should have in house facility accredited by nabl / cpri & any government certified agency & design & development facility certified by iso 9001:2008. housing with supplier word mark / name shall be engraved / embossing on the die cast housing / body part. warranty of 2 years against any manufacturing defect working under standard electrical conditions as mentioned pg 36 item 11.8.8 11.8.8 led street lights 200 watts, supplying and fixing of........mm dia class a gi pipe bracket upto 2 mtrs long bent at suitable angle and fixing to this bracket 1x40 / 2x40 w fluorescent tube street light fitting of all capacities to gi or gi or rail or rcc pole / wall using suitable cla, bolts, and nuts and wiring using suitable capacity wires. pg 45. / 13.1.1 13.1.1 using 25mm dia gi pipe, supplying and fixing........mm dia class a gi pipe bracket upto 2.7 meters long terminated with a reducing collar of 40x25mm to which extra pipe of 175mm length is fixed for fixing mv / sv / mh / ftl street light fitting of all capacities on rail / rcc / wall / tubular pole, using suitable cla, bolts, nuts and wiring using suitable capacity wires. pg 45 / 13.2.1 13.2.1 using 25mm dia gi pipe, supplying and fixing........mm dia class a gi pipe bracket upto 2.7 meters long terminated with a reducing collar of 40x25mm to which extra pipe of 175mm length is fixed for fixing mv / sv / mh / ftl street light fitting of all capacities on rail / rcc / wall / tubular pole, using suitable cla, bolts, nuts and wiring using suitable capacity wires. pg 45 / 13.2.2 13.2.2 using 32mm dia gi pipe, fixing all types and all capacities of 1x4 / 2x2 led light fittings indoor on the wall / ceiling / rafters / girders with necessary supporting frame, using 2310.0076 twin twisted pvc insulated wires, required nos of round blocks and clamps pg 6 / 13.19, fixing of ..... a tpst / change over switch / contactor along with neutral link with screws, bolts, nuts and wiring using required capacity wires and circuit labeling pg 46 / item 13.18.6 300 amps to 400 amps, supplying & fixing led drivers suitable for 5700k led fitting indoor fixtures. operating voltage range from 180v to 265v, 50hz ac power supply pg 43 / 12.51.7 12.51.7 36w 5700k suitable for indoor led fitting, supplying & fixing led drivers suitable for 5700k led fitting indoor fixtures. operating voltage range from 180v to 265v, 50hz ac power supply pg 43 / 12.51.4 12.51.4 15w to 18w 5700k suitable for indoor led fitting, supplying & fixing led drivers suitable for 5700k led fitting outdoor fixtures. operating voltage range from 180v to 265v, 50hz ac power supply pg 43 / 12.52.6 12.52.6 150w 5700k suitable for outdoor led fitting, supplying & fixing led drivers suitable for 5700k led fitting outdoor fixtures. operating voltage range from 180v to 265v, 50hz ac power supply pg 43 / 12.52.2 12.52.2 40w 5700k suitable for outdoor led fitting., supplying & fixing led drivers suitable for 5700k led fitting outdoor fixtures. operating voltage range from 180v to 265v, 50hz ac power supply pg 43 / 12.52.4 12.52.4 90 watts 5700k suitable for out door fitting, releasing the existing fan dismantling testing painting after removing the existing painting by scraping and cleaning ( spray method ) not less than 2 coats of approved make enamel paint to a ceiling fan and wiring and fixing of the same pg 39 / 12.5, supplying and replacing ceiling fan regulator 900mm to 1500mm. pg 39 / 12.6 each 172.00 189.00, releasing the existing fan checking, testing and installation at the same place. pg 39 / item 12.9, releasing the existing ftl fitting all capacities, checking, testing and installing at same place pg 39 / 12.11, fixing halogen / metal halide / svl / il / led floodlight fitting over existing pole / wall ceiling including cla, bolts, nuts and wiring using suitable capacity wires. pg 45 / 13.5, fixing all types and all capacities of fluorescent / false ceiling / spot light / cfl / led fittings indoor on the wall / ceiling / rafters / girders using 23 / 0.0076 twin twisted pvc insulated wires, required nos of round blocks and clamps pg 45 / 13.7.1 13.7.1 on wall / ceiling / rafter / girders, supplying & fixing of retrofit type led bulb ...... w with opal acrylic diffuser comprising of led source with cct 6500 degree k, cri> 70%. efficacy >80 lumen per w, life> 25000 burning hours and compliance to is 10322 / iec 60598, lm 79 & lm 80. the led are driven by hf electronic driver integrated in the system, with pf > 0.95, power loss should < 5% of lamp wage., short circuit & open circuit protection to be integrated in the circuit, thd less than 20%, life as per lm 79. the operating input voltage should be between 130 to 275 v. bis approved and tested by nabl / cpri accredited laboratory with 2 years warranty against any manufacturing defect working under standard electrical condition pg 39 / 11.11.1 11.11.1 3 watts 6500k, supplying & fixing of retrofit type led bulb ...... w with opal acrylic diffuser comprising of led source with cct 6500 degree k, cri> 70%. efficacy >80 lumen per w, life> 25000 burning hours and compliance to is 10322 / iec 60598, lm 79 & lm 80. the led are driven by hf electronic driver integrated in the system, with pf > 0.95, power loss should < 5% of lamp wage., short circuit & open circuit protection to be integrated in the circuit, thd less than 20%, life as per lm 79. the operating input voltage should be between 130 to 275 v. bis approved and tested by nabl / cpri accredited laboratory with 2 years warranty against any manufacturing defect working under standard electrical condition pg 39 / 11.11.6 11.11.6 15 watts 6500k, supplying & fixing of retrofit type led bulb ...... w with opal acrylic diffuser comprising of led source with cct 6500 degree k, cri> 70%. efficacy >80 lumen per w, life> 25000 burning hours and compliance to is 10322 / iec 60598, lm 79 & lm 80. the led are driven by hf electronic driver integrated in the system, with pf > 0.95, power loss should < 5% of lamp wage., short circuit & open circuit protection to be integrated in the circuit, thd less than 20%, life as per lm 79. the operating input voltage should be between 130 to 275 v. bis approved and tested by nabl / cpri accredited laboratory with 2 years warranty against any manufacturing defect working under standard electrical condition pg 39 / 11.11.3 11.11.3 7 watts 6500k, supplying & fixing flexible led strip light ..... w power consumption in 5 ms length cct6500 degree k, cri> 70%. efficacy >80 lumen per w, life> 25000 burning hours and compliance to is 10322 / iec 60598, lm 79 & lm 80. the led are driven by hf electronic driver non integrated, with pf > 0.95, power loss should< 5% of lamp wage., short circuit & open circuit protection to be integrated in the circuit, thd less than 20%, life as per lm 79. the operating input voltage should be between 130 to 275 v. bis approved with 2 years warranty against any manufacturing defect working under standard electrical condition. pg 33 / 11.1, supplying of .....feet pvc batten with integrated led tube .... w with high quality diffuser with life of 25000 burning hours & 70% lumen maintenance with cri > 80. power input: 220 240v@ 50 / 60hz & power factor >0.9 along with ce approved. 2 years warranty against any manufacturing defect working under standard electrical condition pg 34 / 11.3.1 led light fitting 1x2’ 9 / 10 watts, supplying of .....feet pvc batten with integrated led tube .... w with high quality diffuser with life of 25000 burning hours & 70% lumen maintenance with cri > 80. power input: 220 240v@ 50 / 60hz & power factor >0.9 along with ce approved. 2 years warranty against any manufacturing defect working under standard electrical condition pg 34 / 11.3.2 11.3.2 led light fitting 1x4’ 20 / 22 watts, supplying of .....feet pvc batten with integrated led tube .... w with high quality diffuser with life of 25000 burning hours & 70% lumen maintenance with cri > 80. power input: 220 240v@ 50 / 60hz & power factor >0.9 along with ce approved. 2 years warranty against any manufacturing defect working under standard electrical condition pg 34 / 11.3.3 11.3.3 led light fitting 1x4’ 36 / 40 watts, supplying of recess mounting non integrated type led down light...... w luminaire comprising of pressure decast / extruded aluminium housing, with spring loaded false ceiling cla, led of power / cob with cct 6500 degree k, cri> 70%. efficacy >100 lumen per w, 120degree beam spread, life> 25000 burning hours and compliance to is10322 / iec 60598, lm 79 & lm 80. the lamp compartment is enclosed with anti glare opal diffuser which enhances the lighting level. leds are driven by hf electronic driver integrated in a separate control gear assembly., with pf > 0.95, power loss should< 5% of lamp wage, short circuit & open circuit protection to be integrated in the circuit, thd less than 20%, life as per lm 79. the operating input voltage should be between 130 to 275 v. bis approved and tested by nabl / cpri accredited laboratory with 2 years warranty against any manufacturing defect working under standard electrical condition. pg 34 / 11.4.2 11.4.2 10 12 watts, supplying of recess mounting non integrated type led down light...... w luminaire comprising of pressure decast / extruded aluminium housing, with spring loaded false ceiling cla, led of power / cob with cct 6500 degree k, cri> 70%. efficacy >100 lumen per w, 120degree beam spread, life> 25000 burning hours and compliance to is10322 / iec 60598, lm 79 & lm 80. the lamp compartment is enclosed with anti glare opal diffuser which enhances the lighting level. leds are driven by hf electronic driver integrated in a separate control gear assembly., with pf > 0.95, power loss should< 5% of lamp wage, short circuit & open circuit protection to be integrated in the circuit, thd less than 20%, life as per lm 79. the operating input voltage should be between 130 to 275 v. bis approved and tested by nabl / cpri accredited laboratory with 2 years warranty against any manufacturing defect working under standard electrical condition pg 34 / 11.4.3 11.4.3 15 18 watts, supplying of recess mounting non integral type ........ led w luminaire comprising of pressure decast / extruded aluminium housing, with spring loaded false ceiling cla, power leds with cct 6500 degree k, cri> 70%. efficacy > 100 lumen per w, 120degree beam spread, life> 25000 burning hours and compliance to is 10322 / iec 60598, lm 79 & lm 80. the lamp compartment is enclosed with anti glare opal diffuser which enhances the lighting level leds are driven by hf electronic driver integrated in a separate control gear assembly., with pf > 0.95, power loss should< 5% of lamp wage., short circuit & open circuit protection to be integrated in the circuit, thd less than 20%, life as per lm 79. the operating input voltage should be between 130 to 275 v. bis approved and tested by nabl / cpri accredited laboratory with 2 years warranty against any manufacturing defect working under standard electrical condition. pg 32 / 11.6 11.6.1 led modular down light 1x1 34 22 w, supplying of recess mounting non integral type ........ led w luminaire comprising of pressure decast / extruded aluminium housing, with spring loaded false ceiling cla, power leds with cct 6500 degree k, cri> 70%. efficacy > 100 lumen per w, 120degree beam spread, life> 25000 burning hours and compliance to is 10322 / iec 60598, lm 79 & lm 80. the lamp compartment is enclosed with anti glare opal diffuser which enhances the lighting level leds are driven by hf electronic driver integrated in a separate control gear assembly., with pf > 0.95, power loss should< 5% of lamp wage., short circuit & open circuit protection to be integrated in the circuit, thd less than 20%, life as per lm 79. the operating input voltage should be between 130 to 275 v. bis approved and tested by nabl / cpri accredited laboratory with 2 years warranty against any manufacturing defect working under standard electrical condition. pg 32 / 11.6.2 11.6.2 led modular down light 2x2 / 1x4 34 36 watts, supplying ...litres capacity vertical / horizontal type wall mounting electrical water heater with 22 swg copper / ss sheet metal inner container tinned inside fiber body outside, filled with glass wool between inner and outer container for thermal insulation complete. the inlet and outlet pipes so arranged that water flow inside results in water to flow out from the inner container without turbulence. the inner container shall have direct immersion type copper tube nickel plate. 2kw capacity element with a neon indicator fitted with 20a capacity 25 to 85 degree centigrade range thermostat. the water heater shall completely be wired with 40 / 0.0076 inch 3 core copper flexible wire of 1.5 meters length and the outer container provided with heavy gauge brackets for wall mounting. 5 star with fibre body pg 27 / item 7.2.1 7.2.1 25 litres 5 star with fibre body, supplying ...litres capacity vertical / horizontal type wall mounting electrical water heater with 22 swg copper / ss sheet metal inner container tinned inside fiber body outside, filled with glass wool between inner and outer container for thermal insulation complete. the inlet and outlet pipes so arranged that water flow inside results in water to flow out from the inner container without turbulence. the inner container shall have direct immersion type copper tube nickel plate. 2kw capacity element with a neon indicator fitted with 20a capacity 25 to 85 degree centigrade range thermostat. the water heater shall completely be wired with 40 / 0.0076 inch 3 core copper flexible wire of 1.5 meters length and the outer container provided with heavy gauge brackets for wall mounting. 5 star with fibre body pg 27 / item 7.2.3 7.2.3 50 litres 5 star rated with fibre body, erection charges for fixing a upto 30 litres capacity wall mounting electric geysers using bolts, flat at one end nut and washers at the other end for through bolts and nuts and washers with 150x450x600mm back plate and wiring complete with 15a 3 pin top pg 46 / 13.15.1 13.15.1 upto 30 litres, erection charges for fixing a 35 litres to 50 litres capacity wall mounting electric geysers using bolts, flat at one end nut and washers at the other end for through bolts and nuts and washers with 150x450x600mm back plate and wiring complete with 15a 3 pin top pg 46 / 13.15.2 13.15.2 35 litres to 50 litres, supplying, installation, testing & commissioning of 12v ..ah batteries in poly propylene container for d.g. sets. low maintenance batteries, plate type pg 29 / 9.4.4 9.4.4 100 ah capacity, supplying, installation, testing & commissioning of 12v ..ah batteries in poly propylene container for d.g. sets. low maintenance batteries, plate type pg 29 / 9.4.6 9.4.6 150 ah capacity, supplying, installation, testing & commissioning of 12v ..ah batteries in poly propylene container for d.g. sets. low maintenance batteries, plate type pg 29 / 9.4.7 9.4.7 200 ah capacity, supplying, installation, testing & commissioning of 12v ..ah batteries in poly propylene container for d.g. sets. low maintenance batteries, plate type pg 29 / 9.4.1 9.4.1 40 ah capacity, supplying, installation, testing & commissioning of 12v ..ah batteries in poly propylene container for d.g. sets. low maintenance batteries, plate type pg 29 / 9.4.2 9.4.2 60 ah capacity, supplying, installation, testing & commissioning of 12v dc, ah batteries in poly propylene container for u.p.s. sealed maintenance free batteries pg 29 / 9.5.1 9.5.1 7 ah capacity sealed maintenance free batteries, supplying, installation, testing & commissioning of 12v dc, ah batteries in poly propylene container for u.p.s. sealed maintenance free batteries pg 29 / 9.5.2 9.5.2 18 ah capacity sealed maintenance free batteries, supplying, installation, testing & commissioning of 12v dc, ah batteries in poly propylene container for u.p.s. sealed maintenance free batteries pg 29 / 9.5.3 9.5.3 26 ah capacity sealed maintenance free batteries, supplying, installation, testing & commissioning of 12v dc, ah batteries in poly propylene container for u.p.s. sealed maintenance free batteries pg 29 / 9.5.4 9.5.4 42 ah capacity sealed maintenance free batteries, supplying, installation, testing & commissioning of 12v dc, ah batteries in poly propylene container for u.p.s. sealed maintenance free batteries pg 29 / 9.5.5 9.5.5 60 / 65 ah capacity sealed maintenance free batteries, supplying, installation, testing & commissioning of 12v dc, ah batteries in poly propylene container for u.p.s. sealed maintenance free batteries pg 29 / 9.5.6 9.5.6 75 / 80 ah capacity sealed maintenance free batteries, supplying, installation, testing & commissioning of 12v dc, ah batteries in poly propylene container for u.p.s. sealed maintenance free batteries pg 29 / 9.5.7 9.5.7 100 ah capacity sealed maintenance free batteries, supplying, installation, testing & commissioning of 12v dc, ah batteries in poly propylene container for u.p.s. sealed maintenance free batteries pg 29 / 9.5.8 9.5.8 120 ah capacity sealed maintenance free batteries, supplying, installation, testing & commissioning of 12v dc, ah batteries in poly propylene container for u.p.s. sealed maintenance free batteries pg 29 / 9.5.8 9.5.9 150 ah capacity sealed maintenance free batteries, supplying, installation, testing & commissioning of 12v dc, ah batteries in poly propylene container for u.p.s. sealed maintenance free batteries pg 29 / 9.5.8 9.5.10 200 ah capacity sealed maintenance free batteries, supplying and installation of battery to battery connecting cable 10 sqmm copper cable cotton insulation on top including crimping of copper lugs, supplying and installation of battery to battery connecting cable 25 sqmm copper cable cotton insulation on top including crimping of copper lugs, supplying and installation of battery to battery connecting cable 35 sqmm copper cable cotton insulation on top including crimping of copper lugs, supplying and installation of battery to battery connecting cable 50 sqmm copper cable cotton insulation on top including crimping of copper lugs, heavy duty battery to battery jumper cable 25 sqmm , red / black exterior for quick identification , flexible cables, 20 feet in length, carrying case included, heavy duty tight grip alligator clamps strong spring and comfortable handle for easy positioning, supplying, erecting, testing & commissioning of on line ups system suitable for operation on 230v, 50hz, a / c supply, with isolation transformer all accessories complete and excluding batteries and wiring complete pg 29 / 9.3.1 9.3.1 9.3.1 1 kva on line ups make :apc, supplying, erecting, testing & commissioning of on line ups system suitable for operation on 230v, 50hz, a / c supply, with isolation transformer all accessories complete and excluding batteries and wiring complete. pg 29 / 9.3.2 9.3.2 3 kva on line ups, supplying, erecting, testing & commissioning of on line ups system suitable for operation on 230v, 50hz, a / c supply, with isolation transformer all accessories complete and excluding batteries and wiring complete pg 29 / 9.3.3 9.3.3 5 kva on line ups, supplying, erecting, testing & commissioning of off line ups system suitable for operation on 230v, 50hz, a / c supply, with all accessories complete and excluding batteries and wiring complete. pg 29 / 9.2.1 9.2.1 1 kva off line ups, supplying push button operated direct online starter with an antiweld silver cadmium oxide contactor with replaceable fixed and moving contacts and bimetallic thermal overload relay help in anticorrosion treated sheet steel or iron clad enclosure and fixing the same to suitable capacity wires for 230 / 440 v 1 / 3 phase motor upto 5 hp pg 10 / 5.1, supplying fully automatic star delta starter unit push button type with suitable wires, 3 contactors, one adjustable thermal timer mounted on a common base plate held in steel enclosure for use on 400 / 440 v 3 phase and wired after fixing to the existing wooden board for motor pg 10 / 5.2 upto 12.5 hp, supply and fixing of 4pole power contactor with no / nc contacts on existing wood / panel board using necessary bolts, nuts, washers and wiring etc., complete with ac 3 rating and as per is 13947 pg 10 / 5.13.11 5.13.11 400 amps four pole, supply and fixing of 4pole power contactor with no / nc contacts on existing wood / panel board using necessary bolts, nuts, washers and wiring etc., complete with ac 3 rating and as per is 13947 pg 10 / 5.13.11 5.13.15 800 amps four pole, supplying and fixing regular mccb distribution panel confirming to is / iec 61439 3 and ik09 tested as per is / iec 62262 with minimum ip43 protection provided with polyurethane ( pur ) gasket, with suitable earthing system, on wall / wood board / flush mounting using required cl a , bolts, nuts, etc., with provision for fixing of suitable type capacity mccbs as an incomer for 3 phase double door with necessary bus bar completely wired to use on 440v 3phase 4 wire powder coated painting etc., complete with a provision for fixing of single / three phase suitable capacity mcbs as outgoings confirming to is / iec 60898 pg 12 / 5.16.1 5.16.1 4 way, supplying and fixing regular mccb distribution panel confirming to is / iec 61439 3 and ik09 tested as per is / iec 62262 with minimum ip43 protection provided with polyurethane ( pur ) gasket, with suitable earthing system, on wall / wood board / flush mounting using required cl a , bolts, nuts, etc., with provision for fixing of suitable type capacity mccbs as an incomer for 3 phase double door with necessary bus bar completely wired to use on 440v 3phase 4 wire powder coated painting etc., complete with a provision for fixing of single / three phase suitable capacity mcbs as outgoings confirming to is / iec 60898 pg 12 / 5.16.2 5.16.2 8 way, supplying and fixing regular mccb distribution panel confirming to is / iec 61439 3 and ik09 tested as per is / iec 62262 with minimum ip43 protection provided with polyurethane ( pur ) gasket, with suitable earthing system, on wall / wood board / flush mounting using required cl a , bolts, nuts, etc., with provision for fixing of suitable type capacity mccbs as an incomer for 3 phase double door with necessary bus bar completely wired to use on 440v 3phase 4 wire powder coated painting etc., complete with a provision for fixing of single / three phase suitable capacity mcbs as outgoings confirming to is / iec 60898 pg 12 / 5.16.3 5.16.3 12 way, supplying & fixing miniature circuit breakers on existing mcb distribution boards using necessary fixing materials and c type curve, indicator on / off, energy cross 3 with short circuit breaking capacity of 10k and complete wiring as required confirming to iec 60898 pg 13 / 5.17.1 5.17.1 6 32 amps sp, supplying & fixing miniature circuit breakers on existing mcb distribution boards using necessary fixing materials and c type curve, indicator on / off, energy cross 3 with short circuit breaking capacity of 10k and complete wiring as required confirming to iec 60898 pg 13 / 5.17.2 5.17.2 40 amps sp, supplying & fixing miniature circuit breakers on existing mcb distribution boards using necessary fixing materials and c type curve, indicator on / off, energy cross 3 with short circuit breaking capacity of 10k and complete wiring as required confirming to iec 60898 pg 13 / 5.17.3 5.17.3 50 60 amps sp, supplying & fixing miniature circuit breakers on existing mcb distribution boards using necessary fixing materials and c type curve, indicator on / off, energy cross 3 with short circuit breaking capacity of 10k and complete wiring as required confirming to iec 60898 pg 13 / 5.17.4 5.17.4 6 32 amps dp, supplying & fixing miniature circuit breakers on existing mcb distribution boards using necessary fixing materials and c type curve, indicator on / off, energy cross 3 with short circuit breaking capacity of 10k and complete wiring as required confirming to iec 60898 pg 13 / 5.17.5 5.17.5 40 amps dp, supplying & fixing miniature circuit breakers on existing mcb distribution boards using necessary fixing materials and c type curve, indicator on / off, energy cross 3 with short circuit breaking capacity of 10k and complete wiring as required confirming to iec 60898 pg 13 / 5.17.6 5.17.6 50 60 amps dp, supplying & fixing miniature circuit breakers on existing mcb distribution boards using necessary fixing materials and c type curve, indicator on / off, energy cross 3 with short circuit breaking capacity of 10k and complete wiring as required confirming to iec 60898 pg 13 / 5.17.7 5.17.7 5 32 amps tp&n, supplying & fixing miniature circuit breakers on existing mcb distribution boards using necessary fixing materials and c type curve, indicator on / off, energy cross 3 with short circuit breaking capacity of 10k and complete wiring as required confirming to iec 60898 pg 13 / 5.17.8 5.17.8 40 amps tp&n, supplying & fixing miniature circuit breakers on existing mcb distribution boards using necessary fixing materials and c type curve, indicator on / off, energy cross 3 with short circuit breaking capacity of 10k and complete wiring as required confirming to iec 60898 pg 13 / 5.17.8 5.17.9 50 63 amps tp&n, supplying and fixing regular mcb distribution boards on wall / ood board / flush mounting using required clamps , bolts, nuts etc., with provision for fixing suitable type capacity mcbs single phase / 3 phase / single door with powder coated painting made out of 14 swg ms enclosure. pg 13 / 5.18.1 5.18.1 4 way sp&n single door, supplying and fixing regular mcb distribution boards on wall / ood board / flush mounting using required clamps , bolts, nuts etc., with provision for fixing suitable type capacity mcbs single phase / 3 phase / single door with powder coated painting made out of 14 swg ms enclosure. pg 13 / 5.18.2 5.18.2 6 way sp&n single door, supplying and fixing regular mcb distribution boards on wall / ood board / flush mounting using required clamps , bolts, nuts etc., with provision for fixing suitable type capacity mcbs single phase / 3 phase / single door with powder coated painting made out of 14 swg ms enclosure. pg 13 / 5.18.3 5.18.3 8 way sp&n single door, supplying and fixing regular mcb distribution boards on wall / ood board / flush mounting using required clamps , bolts, nuts etc., with provision for fixing suitable type capacity mcbs single phase / 3 phase / single door with powder coated painting made out of 14 swg ms enclosure. pg 13 / 5.18.4 5.18.4 12 way sp&n single door, supplying and fixing regular mcb distribution boards on wall / ood board / flush mounting using required clamps , bolts, nuts etc., with provision for fixing suitable type capacity mcbs single phase / 3 phase / single door with powder coated painting made out of 14 swg ms enclosure. pg 13 / 5.18.5 5.18.5 16 way sp&n single door, supplying and fixing regular mcb distribution boards on wall / ood board / flush mounting using required clamps , bolts, nuts etc., with provision for fixing suitable type capacity mcbs single phase / 3 phase / single door with powder coated painting made out of 14 swg ms enclosure. pg 13 / 5.18.6 5.18.6 4 way sp & n double door, supplying and fixing regular mcb distribution boards on wall / ood board / flush mounting using required clamps , bolts, nuts etc., with provision for fixing suitable type capacity mcbs single phase / 3 phase / single door with powder coated painting made out of 14 swg ms enclosure. pg 13 / 5.18.7 5.18.7 6 way sp&n double door, supplying and fixing regular mcb distribution boards on wall / ood board / flush mounting using required clamps , bolts, nuts etc., with provision for fixing suitable type capacity mcbs single phase / 3 phase / single door with powder coated painting made out of 14 swg ms enclosure. pg 13 / 5.18.8 5.18.8 8 way sp&n double door, supplying and fixing regular mcb distribution boards on wall / ood board / flush mounting using required clamps , bolts, nuts etc., with provision for fixing suitable type capacity mcbs single phase / 3 phase / single door with powder coated painting made out of 14 swg ms enclosure. pg 13 / 5.18.9 5.18.9 12 way sp&n double door, supplying and fixing regular mcb distribution boards on wall / ood board / flush mounting using required clamps , bolts, nuts etc., with provision for fixing suitable type capacity mcbs single phase / 3 phase / single door with powder coated painting made out of 14 swg ms enclosure. pg 13 / 5.18.10 5.18.10 16 way sp&n double door, supplying and fixing regular mcb distribution boards on wall / ood board / flush mounting using required clamps , bolts, nuts etc., with provision for fixing suitable type capacity mcbs single phase / 3 phase / single door with powder coated painting made out of 14 swg ms enclosure. pg 13 / 5.18.11 5.18.11 4 way tp&n double door, supplying and fixing regular mcb distribution boards on wall / ood board / flush mounting using required clamps , bolts, nuts etc., with provision for fixing suitable type capacity mcbs single phase / 3 phase / single door with powder coated painting made out of 14 swg ms enclosure. pg 13 / 5.18.12 5.18.12 8 way tp&n double door, supplying and fixing regular mcb distribution boards on wall / ood board / flush mounting using required clamps , bolts, nuts etc., with provision for fixing suitable type capacity mcbs single phase / 3 phase / single door with powder coated painting made out of 14 swg ms enclosure. pg 13 / 5.18.13 5.18.13 12 way tp&n double door, supplying and fixing regular mcb distribution boards on wall / ood board / flush mounting using required clamps , bolts, nuts etc., with provision for fixing suitable type capacity mcbs single phase / 3 phase / single door with powder coated painting made out of 14 swg ms enclosure. pg 13 / 5.18.14 5.18.14 16 way tp&n double door, supplying, and fixing of hot dip galvanized m.s.bracket suitable for out door luminaries and mounted on octagonal pole using necessary bolts, nuts etc., complete. pg 9 / 4.7.1 4.7.1 single arm bracket with 1000 mm standard 40 / 50 mm dia, supplying of on load change over switches 4 poles, ac23a duty, 415v, 50hz, ac supply. with all accessories. ( sm enclosure sheet metal execution ) pg 11 / 5.12.6 5.12.6 400 amps 4 pole, supplying of on load change over switches 4 poles, ac23a duty, 415v, 50hz, ac supply. with all accessories. ( sm enclosure sheet metal execution ) pg 11 / 5.12.7 5.12.7 630 amps 4 pole, supplying of on load change over switches 4 poles, ac23a duty, 415v, 50hz, ac supply. with all accessories. ( sm enclosure sheet metal execution ) pg 11 / 5.12.8 5.12.8 800 amps 4 pole, networking & telecomunication supplying and drawing utp cat 6e lan cable pg 27 / 8.1, supplying and drawing pvc flexible one pair telephone unarmoured tinned copper cable. pg 27 / 8.2.1 8.2.1 1 pair, supplying and drawing pvc flexible one pair telephone unarmoured tinned copper cable. pg 27 / 8.2.2 8.2.2 2 pair, supplying and drawing pvc flexible one pair telephone unarmoured tinned copper cable. pg 27 / 8.2.3 8.2.3 3 pair, 3 supplying and drawing pvc insulated gas injected physical foam jelly flooded co axial tv cable.rg 6 pg 28 / 8.3, supplying & fixing of switch mounting rack with power manager & cable manager pg 28 / 8.4.1 8.4.1 4u with 450mm depth, supplying & fixing of switch mounting rack with power manager & cable manager pg 28 / 8.4.2 8.4.2 6u with 450mm depth, supplying & fixing of switch mounting rack with power manager & cable manager pg 28 / 8.4.3 8.4.3 9u with 450mm depth, supplying & fixing of switch mounting rack with power manager & cable manager pg 28 / 8.4.4 8.4.4 12u with 450mm depth, supplying & fixing of switch mounting rack with power manager & cable manager pg 28 / 8.4.5 8.4.5 18u with 650mm depth, supplying & fixing of power strip pg 28 / 8.5, supplying of shelf pg 28 / 8.6, supplying & fixing of castor wheels to the shelf ( set of 4 ) pg 28 / 8.7, supplying & fixing of fan pg 28 / item 8.8, supplying fixing of network switches pg 28 / 8.9.18.9.1 48 port gigabyte ( manageable ) , supplying fixing of network switches pg 28 / 8.9.2 8.9.2 24 port gigabyte ( manageable ) , supplying fixing of network switches pg 28 / 8.9.3 8.9.3 10 port gigabyte ( manageable, supplying fixing of network switches pg 28 / 8.9.4 8.9.4 48 port 10 / 100 switch 8.9.5 24 port 10 / 100 switch, supplying fixing of network switches pg 28 / 8.9.5 24 port 10 / 100 switch, supplying fixing of network switches pg 28 / 8.9.6 8.9.6 16 port 10 / 100 switch, supplying fixing of network switches pg 28 / 8.9.7 8.9.7 8 port 10 / 100 switch, supplying fixing of network switches pg 28 / 8.9.7 8.9.8 5 port 10 / 100 switch, supplying fixing of network switches pg 28 / 8.9.7 8.9.9 48 port 10 / 100 / 1000 switch, supplying fixing of network switches pg 28 / 8.9.10 8.9.10 24 port 10 / 100 / 1000 switch, supplying fixing of network switches pg 28 / 8.9.10 8.9.11 16 port 10 / 100 / 1000 switch, supplying fixing of network switches pg 28 / 8.9.10 8.9.12 8 port 10 / 100 / 1000 switch, supplying & fixing of i / o socket with back box pg 28 / 8.10.1 8.10.1 single i / o pg 28 / 8.10.1, supplying & fixing of i / o socket with back box pg 28 / 8.10.2 8.10.2 double i / o, supplying & fixing of ... ms cat 6 patch cable pg 28 / 8.11.1 1 meter, supplying & fixing of ... ms cat 6 patch cable pg 28 / 8.11.2 2 meter, supplying & fixing of ... ms cat 6 patch cable pg 28 / 8.11.3 3meter, supplying & fixing of patch panel for lan cabling pg 28 / 8.12.1 48 port 10 / 100 patch panel, supplying & fixing of patch panel for lan cabling pg 28 / 8.12.2 24 port 10 / 100 patch panel, supplying & fixing of patch panel for lan cabling pg 28 / 8.12.3 16 port 10 / 100 patch panel, supplying & fixing of patch panel for lan cabling pg 28 / 8.12.4 8.12.4 48 port 10 / 100 / 1000 patch panel, supplying & fixing of patch panel for lan cabling pg 28 / 8.12.5 8.12.5 24 port 10 / 100 / 1000 patch panel, supplying & fixing of patch panel for lan cabling pg 28 / 8.12.5 8.12.6 16 port 10 / 100 / 1000 patch panel, providing, supplying to work site, single phase submersible pump sets of 100mm dia ( 4 inch ) suitable for bore well confirming to is 8034 2000 specifications, with testing of as per instructions of engineer incharge of work and latest amendments 5.00 hp / 3.7kw 50 stg p100d [ bwsb sr 2021 22, p.no.166 i.no:10.4 ] , providing, supplying to work site, submersible pump set of 150mm dia suitable for bore well and confirming to is 8034 2000;3phase, ss bowl & impeller with low volt motor as per specifications , as per necessary ammendments and instructions of engineer incharge of work. 10.00 hp 90 lpm @ 220 m = 20 stg outlet dia 2.00” [ bwsb sr 2021 22, p.no.168 i.no:16.7 ] , supply and delivery at site of brand new best make non return valve as per is 778 / 1984 with isi mark and as per its latest amendments p260a size 50 mm [ bwsb sr 2021 22, p.no.170 i.no:28.1 ] , supply and delivery at site brand new best make pvc insulated cable of flat 3 core ( sheathed ) of nominal cross sectional area as per is 694 1990 with isi mark and as per its latest amendments.1x3x6 sqm.p230d [ bwsb sr 2021 22, p.no.169 i.no:22.4 ] , supply and delivery of galvanized mild steel tubes of 6mtr standard length heavy duty ( c class ) as per is 1239 ( part i ) 1990 with latest amendments with isi mark ( one end fitted with heavy duty collar and other end fitted with protective cover ) 50 mm p310a [ bwsb sr 2021 22, p.no.170 i.no:33.1 ] , providing, supplying and fixing suitable for 1.1 kv class ug cable filled with necessary bitumen, labour charges for providing connection using insulated sheathed steel wire cable as per is 1554 / 1988 with latest amendments from kptcl pole to meter board unit, with all necessary materials , tools and equipments, as per specifications with testing of as per instructions of the engineer in charge of the work pg 164 / 44 bwssb sr 21 22 41.1 3.5 core x6 sqmm, labour charges for providing connection using insulated sheathed steel wire cable as per is 1554 / 1988 with latest amendments from kptcl pole to meter board unit, with all necessary materials, tool and equipments, as per specifications with testing of as per instructions of engineer incharge of work. . pg 164 / 44 bwssb sr 21 22 41.2 3.5 core x10 sqmm, labour charges for providing connection using insulated sheathed steel wire cable as per is 1554 / 1988 with latest amendments from kptcl pole to meter board unit, with all necessary materials and tools and equipments, as per specificationswith testing of as per instructions of engineer incharge of work. . pg 164 / 44 bwssb sr 21 22 41.3 3.5 core x25 sqmm, supply and delivery of centrifugal pump set at site brand new best make and with discharge duty conforming to isi standards and its latest amendments pg 164 / 46.1 bwssb sr 21 22 item 46.1 46.1 2 hp size 65x650 head 13 m , discharge 462 lpm, supply and delivery of centrifugal pump set at site brand new best make and with discharge duty conforming to isi standards and its latest amendments pg 164 / 46.1 bwssb sr 21 22 item 46.3 46.3 3 hp size 50x40 head 30 m , discharge 198 lpm, supply and delivery of centrifugal pump set at site brand new best make and with discharge duty conforming to isi standards and its latest amendments pg 164 / 46.1 bwssb sr 21 22 item 46.3 46.4 5 hp size 80x65 head 23.50m, discharge 600 lpm, supply and delivery of centrifugal pump set at site brand new best make and with discharge duty conforming to isi standards and its latest amendments pg 164 / 46.1 bwssb sr 21 22 item 46.3 46.4 5 hp size 80x65 head 46 m, discharge 174 lpm, supply and delivery of centrifugal pump set at site brand new best make and with discharge duty conforming to isi standards and its latest amendments pg 164 / 46.1 bwssb sr 21 22 item 46.3 46.9 10 hp size 80x65 head 34.50 discharge 840 lpm, earthing: supplying and fixing and wiring earth electrode forgroundingcircuits ic cutouts and other equipments on the meter board in the pit. the pits should be filled up with equal proportion of salt andcharcoal150mm around the pipe to complete depth. the connection from the pipeto the conduits etc. is to established through gi wire of sizes as per clause7.3.3 of is 72 using 12mm bolts, nuts, washers and checknuts, the pipe shall have 16 through holes of 12mm dia pg 164 / 45 bwssb sr 21 22, supply and delivery at site brand new best make starter / control panel suitable for following hp centrifugal pump conforming with isi mark and its latest amendments pg 165 / item 49 bwssb sr 21 22 49.1 upto 7.5 hp centrifugal pump, supply and delivery at site brand new best make starter / control panel suitable for following hp centrifugal pump conforming with isi mark and its latest amendments pg 165 / item 49 bwssb sr 21 22 49.2 7.5 to 10 h.p centrifugal pump, supplying and fixing of led type panel board indicating lamp with required colour suitable for 230 / 440 volt ac , 50 hz 12 / 24 volt dc pg 14 / 5.38 pwd sr 22 23, supplying, fixing and wiring 50 / 5 to 400 / 5a, 5va burden current transformer class 0.5 accuracy with tape around pwd sr 22 23 pg 14 item 5.34, supplying, fixing and wiring 1000 / 5 to1600 / 5a, 15va burden class 1 current transformer pwd sr 22 23 pg 14 item 5.36, supplying and fixing lt ug cable of size 4x25sqmm suitable for centrifugal pump set with isi mark and its latest amendments pg 165 / item 52 bwssb sr 21 22, re winding of monoblock motor with copper insulation wire suitable gauge as per isi specifications with all necessary materials and labour charges , tools and equipments with guarantee period of not less than 12 months pg 165 / item 55 55.1 upto 7.5 hp monoblock motor rewinding, re winding of monoblock motor with copper insulation wire suitable gauge as per isi specifications with all necessary materials and labour charges , tools and equipments with guarantee period of not less than 12 months pg 165 / item 55 55.2 10 hp monoblock motor rewinding, supplying ball bearing as per isi specification with guarantee period of not less than 12 months pg 165 / 166 item 56 56.1 bearing cost for 5 hp, supplying ball bearing as per isi specification with guarantee period of not less than 12 months pg 165 / 166 item 56 56.2 bearing cost for 10 hp, labour charges for erection, electrification and commissioning of pump sets, including aligning and balancing of all items including supply and erection of two pair of supporting clamps, bore well caps, cable clips and water tight gland cable protectors, bolts, nuts, valve and gauges, tools and equipments etc., involved in the job as per specifications, with necessary tests as per specifications, with testing of as per instructions of engineer incharge pg 163 item 38 bwssb sr 21 22, labour charges for erection of indoor type panel board and meter board units with all necessary materials and labour tools and equipments including cement concrete for foundation / bed etc, complete as per specification, with testing of as per instructions of engineer incharge of work. n pg 163 / item 39 bwssb sr 21 22, labour charges for providing connection using insulated sheathed steel wire cable as per is 1554 / 1988 with latest amendments from kptcl pole to meter board unit, with all necessary materials , tools and equipments, as per specificationswith testing of as per instructions of engineer incharge of work pg 163 item 41 bwssb sr 21 22 41.1 3.5 core x6 sqmm, labour charges for providing connection using insulated sheathed steel wire cable as per is 1554 / 1988 with latest amendments from kptcl pole to meter board unit, with all necessary materials , tools and equipments, as per specificationswith testing of as per instructions of engineer incharge of work pg 163 item 41 bwssb sr 21 22 41.2 3.5 core x10 sqmm, labour charges for providing connection using insulated sheathed steel wire cable as per is 1554 / 1988 with latest amendments from kptcl pole to meter board unit, with all necessary materials , tools and equipments, as per specificationswith testing of as per instructions of engineer incharge of work pg 163 item 41 bwssb sr 21 22 41.6 3.5 core x16 sqmm, supply and delivery at site 50mm ( 2” ) dia heavy duty unplasticised pvc column pipes with heavy duty collars , rubber profile ring , vibration controil profile ring, freezing and turbulence free leak proof epdm ring with isi mark with latest amendments pg 163 / item 34 bwssb sr 21 22, supply and delivery at site accessories for single phase pump set like ss groove nipples, ss studs & nuts , screw clips & water proof insulation tape etc.. complete with isi mark pg 163 item 26 bwssb sr 21 22, providing main connection from pole pvc insulated sheathed steel wire cable in new trench as per is 1554 / 1988 with latest amendments with isi mark from kptcl pole to meter board pg 163 / item 42 bwssb sr 21 22, supply and delivery at site brand new best make pvc insulated cable of flat 3 core ( sheathed ) of nominal cross sectional area as per is 694 1990 with isi mark and as per its latest amendments pg 161 / 22 bwssb sr 21 22 22.2 1x3x2.5 sqmm, supply and delivery at site brand new best make pvc insulated cable of flat 3 core ( sheathed ) of nominal cross sectional area as per is 694 1990 with isi mark and as per its latest amendments pg 161 / 22 bwssb sr 21 22 22.3 1x3x4 sqmm, supply and delivery at site brand new best make pvc insulated cable of flat 3 core ( sheathed ) of nominal cross sectional area as per is 694 1990 with isi mark and as per its latest amendments pg 161 / 22 bwssb sr 21 22 22.4 1x3x6 sqmm, providing , supplying to work site , submersible pump set of 150mm dia suitable for bore well and conforming to is 8034 2000 : 3 phase ss bowl & impeller with low volt motor as per specifications as per necessary amendments and instructions of engineer –in charge of work pg 159 / 11.5 11.5 3.00 hp – 90 lpm @ 66 mtr= 6 stage outlet dia 2 “, providing , supplying to work site , submersible pump set of 150mm dia suitable for bore well and conforming to is 8034 2000 : 3 phase ss bowl & impeller with low volt motor as per specifications as per necessary amendments and instructions of engineer –in charge of work pg 159 / 11.5 13.6 5.00 hp – 90 lpm @ 110 mtr= 10 stage outlet dia 2 .00“, providing , supplying to work site , submersible pump set of 150mm dia suitable for bore well and conforming to is 8034 2000 : 3 phase ss bowl & impeller with low volt motor as per specifications as per necessary amendments and instructions of engineer –in charge of work pg 159 / 11.5 16.1 10.00 hp – 360 lpm @ 75 mtr= 5 stage outlet dia 2 .00“, work of servicing, leak arresting and oil filtration upto 500 kva power transformers as specified below: a. removing cable connection of transformer after isolating the supply dismantling the cable connection b. replacing the existing leakage l.v side h.t busing gasket, oil seal, bots and nuts etc. of the power transformer. c. replacing the existingnon functioned damaged dehydrating breather by a new breather with new silica gel for the above transformer d. arresting oil leak from exclusive vent, neutral bushing of valves, flanges, is drying arresting the leakage for l.v and hv side of power transformer and refilling of the transformer oil including cost of labour and necessary repaired materials.e. repaint the transformer using light grey epoxy paint of 2 coated as original. f. filtering of oil in the transformer at the transformer center by hot process using stream line filter such that the ielectric strength of oil in the transformer conforms to isi specification. g. painting of entirestructure of transformer yard including fencing using silver paint. pg 11 bwssb sr 21 22 pg 211 / item 3, work of repairs / servicing and overhauling of on load tap changer ( oltc ) of upto 500 kva transformer as specified below:painting of transformer including platform cts etc., with one cost of red oxide to the rusted portion of transformer, 2 coats of m / s grey enamel paint, ryb color paint to ct caps for identification etc., rates should quote inclusive of cleaning of the transformer of all sizes., works of supply fixing and wiring of tap position indicator to rtcc panel transformer as detailed:. tap position indicator aux supply: 110v or 230v ac +15% 50hz, resistance: 1 kilo ohms per step, tele transmitter: 3wire connection 1 to 99 position, display: 2digit 7 segment led, accuracy tolerance +2%, type of mounting: panel mounting 90x90x70mm, dimension: 96mm x 96mm x 70mm, accuracy: class ii pg 212 / 7 bwssb sr 21 22, work of supply, erection and commissioning of indoor upto 250 amps distribution panel as specified below: supply, erection and commissioning of indoor type upto 250 amps mccb distribution panel with outgoing copper bus bar, having, accessories like mccb, incoming and outgoing entry bus bar, ammeter volt meter, ammeter selector switch, led indication lamp, and with suitable m.s box with required stand unit set. suitable for indoor type complete as per latest is standard specification. each pg 213 / 9 bwssb sr 21 22, work of supply and fixing of 85w, led high way fitting to top of panel board, soft starter and breaker as specified below: supplying high pressure high way 85w led fitting die cast aluminum canopy with aluminum housing to control gear, finished stove enamel gray glassy white canopy interior with a pair of anodized aluminum reflectors clear acrylic bowl, gasket lining for dip inseat resistance duly wired with single or multi leds. pg 213 / item 10 bwssb sr 21 22, working of repairing and overhauling of upto 800amps as specified below: complete dismantling of breaker units of upto 800 amps breaker of filter house taking out the fixed and moving contacts of all the poles, cleaning and putting back with necessary lubrication and checking of complete electrical circuit for proper closing and tripping including necessary replacement of ‘v’ bar contact, finger contact, contact tips, arching contact, tripping and closing coil, back housing set, with female contacts, panel fixed contact set including hylem sheet with contacts, gasket and dash pit oil etc., testing of tripping and closing mechanism in order to ensure easy of operation of the breaker and commissioning of the system as per the standard practice without interruption of power supply. pg 215 / item 18 bwssb sr 21 22, work of repairing and overhauling of upto 400 amps lt breaker bus coupler as specified below: complete dismantling of breaker units of 400 amps, breaker of compressor room taking out the fixed and moving contacts of al limbs, cleaning and putting back with necessary lubrication and checking of complete electrical circuit for proper closing and tripping including necessary replacement of v bar contact finger contact, contact tips of arcing, contacts of tripping and closing coil, back housing set, gasket and dash pot oil etc.. testing and tripping and closing mechanism in order to ensure easy operation of the breaker and commissioning of the system as per the standard practice without interruption of power supply. pg 215 / item 19 bwssb sr 21 22, cutting of the damaged portion of upto 3x150sq.mm xlpe cable supplying one number of indoor termination kit upto 3x150sq.mmhtxlpe cable and attending the termination work upto 3x150sq.mm ht cable of neutral side cable by using upto 150sq.mm copper lugs, self adhesive ht tape, crimping tool, heat shrinkable termination kit and required bolts and nuts etc., and commissioning the motor on load. the work including the cost of materials, labour charges, taxes and rebatetowards the cost of released materials etc pg 216 / 22 bwssb sr 21 22, removing & refixing the pump after repairing of existing horizontal mounting / monoblock pump with following spares, etc. including aligning of pump with reference to motor & running the pump on load pg 216 / item 26.1 up to 5 hp, removing & refixing the pump after repairing of existing horizontal mounting / monoblock pump with following spares, etc. including aligning of pump with reference to motor & running the pump on load pg 216 / item 26.2 5 hp to 10 hp, supply and deliver at site of brand new best make gate valve as per is 778 / 1984 with isi mark and as per its latest amendments pg 162 / 27.1 bwssb sr 21 22 27.1 size 50mm, supply and deliver at site of brand new best make gate valve as per is 778 / 1984 with isi mark and as per its latest amendments pg 162 / 27.1 bwssb sr 21 22 27.2 size 65 mm, supply and delivery at site new best brand make non return valve as per is 778 / 1984 with isi mark and as per its latest amendments pg 162 / 28 bwssb sr 21 22 28.1 size 50mm, supply and delivery at site new best brand make non return valve as per is 778 / 1984 with isi mark and as per its latest amendments pg 162 / 28 bwssb sr 21 22 28.2 size 65mm, providing ht cable jointing 3 core 240 sqmm including providing megger test for both side supply and return with all materials and labour charges for digging the trenches and re filling the trenches, providing lt cable jointing 3.5 core 240 / 300 / 400 sqmm including providing megger test for both side supply and return with all materials and labour charges for digging the cable, supply, installing, testing and commissioning common control panel consisting of the following incoming:1 no set of phase indicating lamps with sfu of suitable rating 1 no, analog ammeter, 1 no analog voltmeter 1ni with phase selector switch, isolating switch outgoing for main electrical pump: 1 no. mcb 1 no. dol of s / d starter suitable for respective hp 1 no. electrcal protection like single phase preventor, under voltage over volage, under current over current & dry run protection suitable for the pump described above 1 no indoor type note : 1 dol direct on –line starter s d star delta starter pg 162 / item 29 29.1 up to 6 hp pumps, supply, installing, testing and commissioning common control panel consisting of the following incoming:1 no set of phase indicatinglamps with sfu of suitable rating 1 no, analog ammeter, 1 no analogvoltmeter 1ni with phase selector switch, isolating switch outgoing for main electrical pump: 1 no. mcb 1 no. dol of s / d startersuitable for respective hp 1 no. electrcal protection like single phasepreventor, under voltage over volage, under current over current & dryrun protection suitable for the pump described above 1 no indoor type note : 1 dol direct on –line starter s d star delta starter pg 162 / item 29 29.2 6 hp to 15 hp pumps, supply and delivery at site of best indigenous brand new mcb ( miniature circuit breakers ) of required capacity as per is 88228 / 1978 and its latest amendments with isi mark of 6 / 10 / 16 / 20 / 25 / 40 amps with scalable box pg 162 / 32 bwssb sr 21 22, supply aand delivery at site indigenous brand new power capacitors as per is 2834 / 1986 with latest amendments with kptcl authorities and errection , electrification and conmmissioning of the same at location of respective pump sets.., providing , supplying to work site , single phase submersible pump set pf 100mm dia ( 4 inch ) suitable for bore well conforming to is 8034 2000 specifications , with testing of as per instructions of engineer in charge of work and latest amendments pg 158 / item 6 bwssb sr 21 22 6.1 1.00 hp / 0.75 kw , 7 stg, providing pvc pipes od 25mm and 10 kg / sqcm pg 34 / 1176 bwssb sr 21 22, providing pvc pipes od 32mm and 10 kg / sqcm pg 34 / 1178 bwssb sr 21 22, providing pvc pipes od 50mm and 10 kg / sqcm pg 34 / 1179 bwssb sr 21 22, providing pvc pipes od 90mm and 10 kg / sqcm pg 34 / 1182 bwssb sr 21 22, providing pvc pipes od 75mm and 10 kg / sqcm pg 34 / 1181 bwssb sr 21 22, providing repairs of oltc transformers upto 500 kva bwssb sr 21 22 pg no 36 / 1250, replacement of gland packing with all materials etc.. complete pg 37 / item 1258 bwssb sr 21 22, providing servicing to 500 kva transformer pg 38 / item 1308 bwssb sr 21 22, supply and fixing of insulator for ht panel pg 38 / 1318 bwssb sr 21 22, providing digital hygrometer with nabl certificate pg 102 / 3.87 bwssb sr 21 22, labour charges foroverhauling of the pump set pg 157 / 3.21 bwssb sr 21 22, providing rewinding. / reconditioning of the 5 hp submergiblepumpsets, items requiring replacements decided by the departmental officials, with respective make of damaged ones, including all materials, labour, equipments and testing. lifting of the submersible motor from the well and re errection charges and complete overhauling etc.., providing human resource including wireman / electricians / dg operators / ac technicians rs 496.22 / per person / per day / rs 14, 886.60x12=1, 78.639.20 pwd sr 20 21 pg no: a 51 item 27, supplying , installation , testing and commissioning of 12 volt dc , 100 ah batteries in poly propylene container for dg sets , low maintenance batteries plate type pg 29 item 9.4 9.4.4 100 ah capacity, supplying , installation , testing and commissioning of 12 volt dc , 100 ah batteries in poly propylene container for dg sets , low maintenance batteries plate type pg 29 item 9.4 9.4.5 120 ah capacity, supplying , installation , testing and commissioning of 12 volt dc , 100 ah batteries in poly propylene container for dg sets , low maintenance batteries plate type pg 29 item 9.4 9.4.6 150 ah capacity, supplying , installation , testing and commissioning of 12 volt dc , 100 ah batteries in poly propylene container for dg sets , low maintenance batteries plate type pg 29 item 9.4 9.4.7 200 ah capacity, supplying , installation , testing and commissioning of 12 dc , 7 ah batteries in poly propylene container for u.p.s sealed maintenance batteries pg 29 item 9.5.1 9.5.1 7 ah capacity, supplying , installation , testing and commissioning of 12 dc , 18 ah batteries in poly propylene container for u.p.s sealed maintenance batteries pg 29 item 9.5.2 9.5.2 18 ah capacity, supplying , installation , testing and commissioning of 12 dc , 26 ah batteries in poly propylene container for u.p.s sealed maintenance batteries pg 29 item 9.5.3 9.5.3 26 ah capacity, supplying , installation , testing and commissioning of 12 dc , 42 ah batteries in poly propylene container for u.p.s sealed maintenance batteries pg 29 item 9.5.4 9.5.4 42 ah capacity, supplying , installation , testing and commissioning of 12 dc , 60 / 65 ah batteries in poly propylene container for u.p.s sealed maintenance batteries pg 29 item 9.5.5 9.5.5 60 / 65 ah capacity, supplying , installation , testing and commissioning of 12 dc , 75 / 80 ah batteries in poly propylene container for u.p.s sealed maintenance batteries pg 29 item 9.5.6 9.5.6 75 / 80 ah capacity, supplying , installation , testing and commissioning of 12 dc , 100 ah batteries in poly propylene container for u.p.s sealed maintenance batteries pg 29 / 30 item 9.5.7 9.5.7 100 ah capacity, supplying , installation , testing and commissioning of 12 dc , 120 ah batteries in poly propylene container for u.p.s sealed maintenance batteries pg 29 / 30 item 9.5.8 9.5.8 120 ah capacity, supplying , installation , testing and commissioning of 12 dc , 150 ah batteries in poly propylene container for u.p.s sealed maintenance batteries pg 29 / 30 item 9.5.9 9.5.9 150 ah capacity, supplying , installation , testing and commissioning of 12 dc , 200 ah batteries in poly propylene container for u.p.s sealed maintenance batteries pg 29 / 30 item 9.5.9 9.5.10 200 ah capacity, supplying of .....feet pvc batten with integrated ledtube....w with high quality diffuser with life of 25000burninghours & 70% lumen maintenance with cri>80.powerinput: 220 240v@ 50 / 60hz & power factor>0.9alongwithceapproved. 2 years warranty against any manufacturing defect working under standard electrical condition pg 34 / 11.3 11.3.1 led light fitting 1x2’ 9 / 10 watt, supplying of .....feet pvc batten with integrated led tubew with high quality diffuser with life of 25000 burning hours & 70% lumen maintenance with cri > 80.powerinput: 220 240v@ 50 / 60hz & power factor >0.9alongwithceapproved. 2 years warranty against any manufacturing defect working under standard electrical condition pg 34 / 11.3 .2 11.3.2 led light fitting 1x4’ 20 / 22 watts, supplying of .....feet pvc batten with integrated led tube...w with high quality diffuser with life of 25000 burninghours & 70% lumen maintenance with cri > 80.powerinput: 220 240v@ 50 / 60hz & power factor >0.9alongwithceapproved. 2 years warranty against anymanufacturingdefectworking under standard electrical condition pg 34 / 11.3 .2 11.3.2 led light fitting 1x4’ 36 / 40 watts, led down light supplying of recess mounting non integrated type led down light...... w luminaire comprising of pressure decast / extruded aluminium housing, with spring loaded falseceilingcla, led of power / cob with cct 6500 degreek, cri>70%. efficacy >100 lumen per w, 120degreebeamspread, life> 25000 burning hours and compliancetois10322 / iec60598, lm 79 & lm 80. the lamp compartment is enclosed with anti glare opal diffuser which enhances the lighting level. leds are driven by hf electronic driver integrated in separate control gear assembly., with pf > 0.95, powerlossshould< 5% of lamp wage, short circuit &opencircuitprotection to be integrated in the circuit, thdlessthan20%, life as per lm 79. the operating input voltage should be between 130 to 275 v. bis approved and tested by nabl / cpri accredited laboratory with 2 years warranty against any manufacturing defect working under standard electrical condition pg 34 / 11.4.1 11.4.1 5 6 watts, led down light supplying of recess mounting non integrated type led down light...... w luminaire comprising of pressure decast / extruded aluminium housing, with spring loaded falseceilingcla, led of power / cob with cct 6500 degreek, cri>70%. efficacy >100 lumen per w, 120degreebeamspread, life> 25000 burning hours and compliancetois10322 / iec60598, lm 79 & lm 80. the lamp compartment is enclosed with anti glare opal diffuser which enhances the lighting level. leds are driven by hf electronic driver integrated in separate control gear assembly., with pf > 0.95, powerlossshould< 5% of lamp wage, short circuit &opencircuitprotection to be integrated in the circuit, thdlessthan20%, life as per lm 79. the operating input voltage should be between 130 to 275 v. bis approved and tested by nabl / cpri accredited laboratory with 2 years warranty against any manufacturing defect working under standard electrical condition pg 34 / 11.4.1 11.4.2 10 12 watts, led down light supplying of recess mounting non integrated type led down light...... w luminaire comprising of pressure decast / extruded aluminium housing, with spring loaded falseceilingcla, led of power / cob with cct 6500 degreek, cri>70%. efficacy >100 lumen per w, 120degreebeamspread, life> 25000 burning hours and compliancetois10322 / iec60598, lm 79 & lm 80. the lamp compartment is enclosed with anti glare opal diffuser which enhances the lighting level. leds are driven by hf electronic driver integrated in separate control gear assembly., with pf > 0.95, powerlossshould< 5% of lamp wage, short circuit &opencircuitprotection to be integrated in the circuit, thdlessthan20%, life as per lm 79. the operating input voltage should be between 130 to 275 v. bis approved and tested by nabl / cpri accredited laboratory with 2 years warranty against any manufacturing defect working under standard electrical condition pg 34 / 11.4.1 11.4.3 15 18 watts, supply of round / square recess / surface mounted rolling type led down light with ...... w gu 10 led lamp rib fabricated from diecast aluminium with white powdercoated prewired to mains connector & has swivelling unit aluminium die cast eye ball & led lamp position retainedcircular wire spring, with life of 25000 burning hours&70%lumen maintenance with cri > 80. power input:220 240v@50 / 60hz & power factor >0.9 along with ce approved. 2yearswarranty against any manufacturing defect working understandard electrical condition pg 34 / item 11.5 11.5.1 led square or round down light 5 6 watts, supply of round / square recess / surface mounted rolling type led down light with ...... w gu 10 led lamp rib fabricated from diecast aluminium with white powdercoated prewired to mains connector & has swivelling unit aluminium die cast eye ball & led lamp position retainedcircular wire spring, with life of 25000 burning hours&70%lumen maintenance with cri > 80. power input:220 240v@50 / 60hz & power factor >0.9 along with ce approved. 2yearswarranty against any manufacturing defect working understandard electrical condition pg 34 / item 11.5 11.5.5 led square or down light 10 12 watts, supply of round / square recess / surface mounted rolling type led down light with ...... w gu 10 led lamp rib fabricated from diecast aluminium with white powdercoated prewired to mains connector & has swivelling unit aluminium die cast eye ball & led lamp position retainedcircular wire spring, with life of 25000 burning hours&70%lumen maintenance with cri > 80. power input:220 240v@50 / 60hz & power factor >0.9 along with ce approved. 2yearswarranty against any manufacturing defect working understandard electrical condition pg 34 / item 11.5 11.5.3 led square or down light 15 18 watts, supplying of recess mounting non integral type ........ ledw luminaire comprising of pressure decast / extrudedaluminiumhousing, with spring loaded false ceiling cla, power leds with cct 6500 degree k, cri> 70%. efficacy > 100 lumen perw, 120degree beam spread, life> 25000 burning hoursandcompliance to is 10322 / iec 60598, lm 79 & lm80.the lamp compartment is enclosed with anti glare opal diffuser which enhances the lighting level leds are drivenbyhf electronic driver integrated in a separate control gear assembly., with pf > 0.95, power loss should< 5% of lampwage., short circuit & open circuit protection to beintegratedin the circuit, thd less than 20%, life as perlm79.theoperating input voltage should be between 130 to 275 volts.bisapproved and tested by nabl / cpri accredited laboratorywith 2 years warranty against any manufacturing defect working under standard electrical condition. n pg 35 / 11.6 11.6.1 led modular down light 1x1 34 22 w, supplying of recess mounting non integral type ........ ledw luminaire comprising of pressure decast / extrudedaluminiumhousing, with spring loaded false ceiling cla, power leds with cct 6500 degree k, cri> 70%. efficacy > 100 lumen perw, 120degree beam spread, life> 25000 burning hoursandcompliance to is 10322 / iec 60598, lm 79 & lm80.the lamp compartment is enclosed with anti glare opal diffuser which enhances the lighting level leds are drivenbyhf electronic driver integrated in a separate control gear assembly., with pf > 0.95, power loss should< 5% of lampwage., short circuit & open circuit protection to beintegratedin the circuit, thd less than 20%, life as perlm79.theoperating input voltage should be between 130 to 275 volts.bisapproved and tested by nabl / cpri accredited laboratorywith 2 years warranty against any manufacturing defect working under standard electrical condition. n pg 35 / 11.6 11.6.2 led modular down light 2x2 / 1x4 34 36 w, supplying of recess mounting non integral type ........ ledw luminaire comprising of pressure decast / extrudedaluminiumhousing, with spring loaded false ceiling cla, power leds with cct 6500 degree k, cri> 70%. efficacy > 100 lumen perw, 120degree beam spread, life> 25000 burning hoursandcompliance to is 10322 / iec 60598, lm 79 & lm80.the lamp compartment is enclosed with anti glare opal diffuser which enhances the lighting level leds are drivenbyhf electronic driver integrated in a separate control gear assembly., with pf > 0.95, power loss should< 5% of lampwage., short circuit & open circuit protection to beintegratedin the circuit, thd less than 20%, life as perlm79.theoperating input voltage should be between 130 to 275 volts.bisapproved and tested by nabl / cpri accredited laboratorywith 2 years warranty against any manufacturing defect working under standard electrical condition. n pg 35 / 11.6 11.6.3 led modular down light 2’x2’ / 1’x4’ 42 55 watts, supply of led floodlight luminaire with pressure die cast luminium housing body for optimal thermal dissipation.lamp compartment comprising of anti glare clear diffuser with injection moulded polycarbonate / clear glass material, delivering superior light output rated life burning hrs 50000 hr @ lumen maintenance of 70%, cct > 5500k, ip66optical and electrical compartment & impactresistanceofcomplete luminaire > ik08. power factor >0.9 with mains, surge protection min 5kv along with over voltage / overload, short circuit / miss wiring protection. compatiblefor pole mauling with outer dia of 40mm to 50mm.universalvoltage driver to operate wide voltage range from 100 v to 270v 50 / 60hz application. compliance to is 10322 / iec 60598, lm 79 & lm 80 adherence with rohs. ul approvedmcpcb. top access street light with single screwtoensureease of maintenance at the sight site locationwithminimized minimal tools. led light fixture with ....... w system power consumption. led efficiency> 1301m / w, nominalcri>75. luminaire manufacturer should have in housefacilityaccredited by nabl / cpri & any governmentcertifiedagency & design & development facility certified by iso 9001:2008. housing with supplier word mark / name shall engraved / embossing on the die cast housing / body partwarranty of 2 years against any manufacturing defect working under standard electrical conditions as mentioned pg 37 / 11.9 11.9.5 led flood light 180 watts, supply of led floodlight luminaire with pressure die cast luminium housing body for optimal thermal dissipation.lamp compartment comprising of anti glare clear diffuser with injection moulded polycarbonate / clear glass material, delivering superior light output rated life burning hrs 50000 hr @ lumen maintenance of 70%, cct > 5500k, ip66optical and electrical compartment & impactresistanceofcomplete luminaire > ik08. power factor >0.9 with mains, surge protection min 5kv along with over voltage / overload, short circuit / miss wiring protection. compatiblefor pole mauling with outer dia of 40mm to 50mm.universalvoltage driver to operate wide voltage range from 100 v to 270v 50 / 60hz application. compliance to is 10322 / iec 60598, lm 79 & lm 80 adherence with rohs. ul approvedmcpcb. top access street light with single screwtoensureease of maintenance at the sight site locationwithminimized minimal tools. led light fixture with ....... w system power consumption. led efficiency> 1301m / w, nominalcri>75. luminaire manufacturer should have in housefacilityaccredited by nabl / cpri & any governmentcertifiedagency & design & development facility certified by iso 9001:2008. housing with supplier word mark / name shall engraved / embossing on the die cast housing / body partwarranty of 2 years against any manufacturing defect working under standard electrical conditions as mentioned pg 37 / 11.9 11.9.6 led flood light 200 watts, supply of led streetlight luminaire with pressure die cast luminium housing body for optimal thermal dissipation.lamp compartment comprising of anti glarecleardiffuserwith injection moulded polycarbonate material, deliveringsuperior light output rated life burning hrs 50000 hr @lumen maintenance of 70%, maximum light intensityshouldbe between 60 degrees to 70 degrees. cct>5500k, ip66optical and electrical compartment & impactresistanceofcomplete luminaire > ik08. power factor>0.9withmains, surge protection min 5kv along with over voltage / overload, short circuit / miss wiring protection. compatiblefor pole mounting with outer dia of 40mm to 50mm. universalvoltage driver to operate wide voltage range from100vto270v50 / 60hz application. compliance to is 10322 / iec 60598, lm 79 & lm 80 adherence with rohs. ul approved mcpcb.top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimaltools. led light fixture with ........w system powerconsumption. led efficiency>1301m / w, nominal cri >75. luminaire manufacturer should have in house facilityaccredited by nabl / cpri & any government certified agency & design & development facility certified by iso 9001:2008. housing with supplier word mark / name shall be engraved / embossing on the die cast housing / body part. warranty of 2 years against any manufacturing defect working under standard electrical conditions as mentioned pg 37 / 11.8 11.8.4 led street light 90 watts, supply of led streetlight luminaire with pressure die cast luminium housing body for optimal thermal dissipation.lamp compartment comprising of anti glarecleardiffuserwith injection moulded polycarbonate material, deliveringsuperior light output rated life burning hrs 50000 hr @lumen maintenance of 70%, maximum light intensityshouldbe between 60 degrees to 70 degrees. cct>5500k, ip66optical and electrical compartment & impactresistanceofcomplete luminaire > ik08. power factor>0.9withmains, surge protection min 5kv along with over voltage / overload, short circuit / miss wiring protection. compatiblefor pole mounting with outer dia of 40mm to 50mm. universalvoltage driver to operate wide voltage range from100vto270v50 / 60hz application. compliance to is 10322 / iec 60598, lm 79 & lm 80 adherence with rohs. ul approved mcpcb.top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimaltools. led light fixture with ........w system powerconsumption. led efficiency>1301m / w, nominal cri >75. luminaire manufacturer should have in house facilityaccredited by nabl / cpri & any government certified agency & design & development facility certified by iso 9001:2008. housing with supplier word mark / name shall be engraved / embossing on the die cast housing / body part. warranty of 2 years against any manufacturing defect working under standard electrical conditions as mentioned pg 37 / 11.8 11.8.5 led street light 120 watts, supply of led streetlight luminaire with pressure die cast luminium housing body for optimal thermal dissipation.lamp compartment comprising of anti glarecleardiffuserwith injection moulded polycarbonate material, deliveringsuperior light output rated life burning hrs 50000 hr @lumen maintenance of 70%, maximum light intensityshouldbe between 60 degrees to 70 degrees. cct>5500k, ip66optical and electrical compartment & impactresistanceofcomplete luminaire > ik08. power factor>0.9withmains, surge protection min 5kv along with over voltage / overload, short circuit / miss wiring protection. compatiblefor pole mounting with outer dia of 40mm to 50mm. universalvoltage driver to operate wide voltage range from100vto270v50 / 60hz application. compliance to is 10322 / iec 60598, lm 79 & lm 80 adherence with rohs. ul approved mcpcb.top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimaltools. led light fixture with ........w system powerconsumption. led efficiency>1301m / w, nominal cri >75. luminaire manufacturer should have in house facilityaccredited by nabl / cpri & any government certified agency & design & development facility certified by iso 9001:2008. housing with supplier word mark / name shall be engraved / embossing on the die cast housing / body part. warranty of 2 years against any manufacturing defect working under standard electrical conditions as mentioned pg 37 / 11.8 11.8.6 led street light 150 watts, supply of led streetlight luminaire with pressure die cast luminium housing body for optimal thermal dissipation.lamp compartment comprising of anti glarecleardiffuserwith injection moulded polycarbonate material, deliveringsuperior light output rated life burning hrs 50000 hr @lumen maintenance of 70%, maximum light intensityshouldbe between 60 degrees to 70 degrees. cct>5500k, ip66optical and electrical compartment & impactresistanceofcomplete luminaire > ik08. power factor>0.9withmains, surge protection min 5kv along with over voltage / overload, short circuit / miss wiring protection. compatiblefor pole mounting with outer dia of 40mm to 50mm. universalvoltage driver to operate wide voltage range from100vto270v50 / 60hz application. compliance to is 10322 / iec 60598, lm 79 & lm 80 adherence with rohs. ul approved mcpcb.top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimaltools. led light fixture with ........w system powerconsumption. led efficiency>1301m / w, nominal cri >75. luminaire manufacturer should have in house facilityaccredited by nabl / cpri & any government certified agency & design & development facility certified by iso 9001:2008. housing with supplier word mark / name shall be engraved / embossing on the die cast housing / body part. warranty of 2 years against any manufacturing defect working under standard electrical conditions as mentioned pg 37 / 11.8 11.8.8 led street light 200 watts, supplying and fixing of slim box type fitting , made out of crca sheet metal body with locking type holder completely wired excluding ballast & flourescent tube 1x2’ tube light fitting, supplying and fixing of slim box type fitting , made out of crca sheet metal body with locking type holder completely wired excluding ballast & flourescent tube 1x4” tube light fitting, supplying and fixing of slim box type fitting , made out of crca sheet metal body with locking type holder completely wired excluding ballast & flourescent tube 2x4’ tube light fittings, supplying and fixing one of 230 volts ding dong bell and a flush type bell push with gang box on necessary wooden or rawl plugs using nf screws with remote pg 39 / 12.2 12.2.3 remote, releasing an unserviceable thermostat and providing in its place a new 20 a capacity 25 inch to 85 inch range thermostat pg 39 / 12.7, releasing an unserviceable thermostat and providing in its place a new 20 a capacity 25 inch to 85 inch range thermostat for racold make geysers, releasing an unserviceable thermostat and providing in its place a new 20 a capacity 25 inch to 85 inch range thermostat for haier make geysers, releasing an unserviceable thermostat and providing in its place a new 20 a capacity 25 inch to 85 inch range thermostat for for johnson / bajaj make geysers, supplying and fixing / replacement of heating element for geyser / boiler make: racold / smith, supplying and fixing / replacement of heating element for geyser / boiler make: johnson / bajaj, supplying and fixing / replacement of pressure relief valve suitable for geyser pg 39 / 12.14, supplying and fixing / replacement of round / conical diamond shaped hdpe doom suitable for 125 / 160 watts post lamp fittings pg 39 / 12.15, supplying and fixing / replacing condenser for ceiling fan and other accessories pg 39 / 12.3 12.3.1 upto 4mfd, supplying and fixing / replacing condenser for ceiling fan and other accessories pg 39 / 12.3 12.3.3 10 mfd, supplying and fixing / replacing condenser for ceiling fan and other accessories pg 39 / 12.3 12.3.6 33 mfd, supplying and fixing 6 amps capacity 4 way universal shutter type spike buster suitable to operate on 230 volts 50 hz ac supply pg 40 / 12.16, painting of existing street light pole after scrapping the old paint and painted with suitable colour enamel / silver paint including coping / footing of the pole pg 40 / 12.17 12.17.1 up to 5 mtr street light pole, painting of existing street light pole after scrapping the old paint and painted with suitable colour enamel / silver paint including coping / footing of the pole pg 40 / 12.17 12.17.2 above 5.5 mtr to 7.5 mtr strret light pole, supplying & fixing led drivers suitable for 5700k led fitting indoor fixtures operating voltage range from 180 volts to 265 volts ac power supply pg 43 / 12.51 12.51.7 36 watts 5700 k suitable for indoor led fitting, supplying & fixing led drivers suitable for 5700k led fitting outdoor fixtures operating voltage range from 180 volts to 265 volts ac power supply 12.52.4 90 watts 5700k suitable for out door led fitting, supplying & fixing led drivers suitable for 5700k led fitting outdoor fixtures operating voltage range from 180 volts to 265 volts ac power supply 12.52.6 150 watts 5700k suitable for outdoor led fittings, supplying & fixing led drivers suitable for 5700k led fitting outdoor fixtures operating voltage range from 180 volts to 265 volts ac power supply 12.52.8 200 watts 5700k suitable for out door led fittings, supplying and fixing of led projector including ceiling mounting brackets as per the site condtions . native resolution –xga ( 1024x768 ) or higher , brightness 4000 lumens or higher , lamp life upto 10, 000 hours, contrast ratio 16, 000:1 or more, video compatibility –ntsc, pal, with dual port hdmi, audio audio out connector support with 16 watts audio out put , zoom / focus manual , display input hdmix2, usbx2 composite a / v wifi automatic connectivity with a warranty of one year on site including cost of all materials , labour as per specifications & as directed by engineer in charge of the work, supplying and fixing of lcd projector screen 5’x7’ ( manual type ) , supplying and drawing hdmi cable for lcd projector to computer 15 mtrs in length, supplying and drawing hdmi cable for lcd projector to computer 10 mtrs in length, supplying and drawing hdmi cable for lcd projector to computer 5mtrs in length, supplying and drawing hdmi cable for lcd projector to computer 2 mtrs in length, supplying and fixing of conversion plugs 16 amps for imported machines, providing audio cables from amplifier to mic 15 mtrs in length with pins and soldering, providing wireless receiver for amplifier, supplying and fixing of additional speakers from the amplifier, supplying and drawing speaker cables from the amplifier including supplying and drawing pvc pipe 19 / 20mm, supplying and fixing of vga to hdmi converter, supplying and fixing of vga to hdmi converter, providing services and replacement of refrigerators of various make including replacement of gaskets / thermostat and complete overhauling, supplying and fixng of compressors gr refrigerators including leakage arresting and gas charging, supplying and fixing of led tv full hd 32 inches smart tv , supported internet services netflix, zee5, hoichoi, amazon prime video, voot, sonyliv, disney+hotstar, & many more: display technology : led , resolution : 720p, refresh rate : 60 hz with special feature : google tv / watchlist / voice search / google play / chromecast / netflix / amazon prime video / additional features: apple airplay / apple homekit / alexagoogle tv / watchlist / voice search / google play / chromecast / netflix / amazon prime video / additional features: apple airplay / apple homekit / alexa with mounting hard ware : table top stand / remote controller warranty card, 1 ac adapter, 1 ac power cord, 1 remote control, 1 table top stand, 1 user manual, 2 aaa batteries warranty : one year brand : sony / samsung / lg, supplying and fixing of led tv full hd 43 inches smart tv , supported internet services netflix, zee5, hoichoi, amazon prime video, voot, sonyliv, disney+hotstar, & many more: display technology : led , resolution : 720p, refresh rate : 60 hz with special feature : google tv / watchlist / voice search / google play / chromecast / netflix / amazon prime video / additional features: apple airplay / apple homekit / alexagoogle tv / watchlist / voice search / google play / chromecast / netflix / amazon prime video / additional features: apple airplay / apple homekit / alexa with mounting hard ware : table top stand / remote controller warranty card, 1 ac adapter, 1 ac power cord, 1 remote control, 1 table top stand, 1 user manual, 2 aaa batteries warranty : one year brand : sony / samsung / lg, supplying and fixing of led tv full hd 50 inches smart tv , supported internet services netflix, zee5, hoichoi, amazon prime video, voot, sonyliv, disney+hotstar, & many more: display technology : led , resolution : 720p, refresh rate : 60 hz with special feature : google tv / watchlist / voice search / google play / chromecast / netflix / amazon prime video / additional features: apple airplay / apple homekit / alexagoogle tv / watchlist / voice search / google play / chromecast / netflix / amazon prime video / additional features: apple airplay / apple homekit / alexa with mounting hard ware : table top stand / remote controller warranty card, 1 ac adapter, 1 ac power cord, 1 remote control, 1 table top stand, 1 user manual, 2 aaa batteries warranty : one year brand : sony / samsung / lg, supplying and fixing of tata play set top bx with stand, supplying and fixing of ceiling mounting bracket for 32 inches full hd led ( same manufacturer ) , supplying and fixing of ceiling mounting bracket for 43 inches full hd led ( same manufacturer ) , supplying and fixing of ceiling mounting bracket for 50 inches full hd led ( same manufacturer ) , supplying of 1.1 kv cable xlpe or heat resistant pvc insulated, pvc extruded inner sheath armoured ug lt cable as per is 1554 ( part 1 ) or is 7098 part 1, armouring strip thickness in average +5% and resistivity 14 ohms / kms ( max ) as per is 3975 ( page no. 09 item no.32 ) bescom sr rs.183442 / per km 32.05: 16 sqmm 4 core ( 11 gi strips 4x0.8mm, supplying of 1.1 kv cable xlpe or heat resistant pvc insulated, pvc extruded inner sheath armoured ug lt cable as per is 1554 ( part 1 ) or is 7098 part 1, armouring strip thickness in average +5% and resistivity 14 ohms / kms ( max ) as per is 3975 ( page no. 09 item no.32 ) bescom sr rs.183442 / per km 32.10 35 sqmm 4 core ( 15 gi strips 4x0.8mm, supplying of 1.1 kv cable xlpe or heat resistant pvc insulated, pvc extruded inner sheath armoured ug lt cable as per is 1554 ( part 1 ) or is 7098 part 1, armouring strip thickness in average +5% and resistivity 14 ohms / kms ( max ) as per is 3975 ( page no. 09 item no.32 ) bescom sr rs.183442 / per km 32.12 50 sqmm 4 core ( 17 gi strips 4x0.8mm, supplying of 1.1 kv cable xlpe or heat resistant pvc insulated, pvc extruded inner sheath armoured ug lt cable as per is 1554 ( part 1 ) or is 7098 part 1, armouring strip thickness in average +5% and resistivity 14 ohms / kms ( max ) as per is 3975 ( page no. 09 item no.32 ) bescom sr rs.183442 / per km 32.13 70 sqmm 4 core ( 18 gi strips 4x0.8mm, supplying of 1.1 kv cable xlpe or heat resistant pvc insulated, pvc extruded inner sheath armoured ug lt cable as per is 1554 ( part 1 ) or is 7098 part 1, armouring strip thickness in average +5% and resistivity 14 ohms / kms ( max ) as per is 3975 ( page no. 09 item no.32.14 95 sqmm 4 core ( 18 gi strips 4x0.8mm, supplying of 1.1 kv cable xlpe or heat resistant pvc insulated, pvc extruded inner sheath armoured ug lt cable as per is 1554 ( part 1 ) or is 7098 part 1, armouring strip thickness in average +5% and resistivity 14 ohms / kms ( max ) as per is 3975 ( page no. 09 item no.32.15 120 sqmm 4 core ( 18 gi strips 4x0.8mm, supplying of 1.1 kv cable xlpe or heat resistant pvc insulated, pvc extruded inner sheath armoured ug lt cable as per is 1554 ( part 1 ) or is 7098 part 1, armouring strip thickness in average +5% and resistivity 14 ohms / kms ( max ) as per is 3975 ( page no. 09 item no.32.16 150 sqmm 4 core ( 25 gi strips 4x0.8mm, supplying of 1.1 kv cable xlpe or heat resistant pvc insulated, pvc extruded inner sheath armoured ug lt cable as per is 1554 ( part 1 ) or is 7098 part 1, armouring strip thickness in average +5% and resistivity 14 ohms / kms ( max ) as per is 3975 ( page no. 09 item no.32.17 185 sqmm 4 core ( 28 gi strips 4x0.8mm, supplying of 1.1 kv cable xlpe or heat resistant pvc insulated, pvc extruded inner sheath armoured ug lt cable as per is 1554 ( part 1 ) or is 7098 part 1, armouring strip thickness in average +5% and resistivity 14 ohms / kms ( max ) as per is 3975 ( page no. 09 item no.32.18 240 sqmm 4 core ( 30 gi strips 4x0.8mm ) , supplying of 1.1 kv cable xlpe or heat resistant pvc insulated, pvc extruded inner sheath armoured ug lt cable as per is 1554 ( part 1 ) or is 7098 part 1, armouring strip thickness in average +5% and resistivity 14 ohms / kms ( max ) as per is 3975 ( page no. 09 item no.32.19 300 sqmm 4 core ( 32 gi strips 4x0.8mm ) , supplying of 1.1 kv cable xlpe or heat resistant pvc insulated, pvc extruded inner sheath armoured ug lt cable as per is 1554 ( part 1 ) or is 7098 part 1, armouring strip thickness in average +5% and resistivity 14 ohms / kms ( max ) as per is 3975 ( page no. 09 item no.32.20 400 sqmm 4 core ( 39 gi strips 4x0.8mm ) , providing copper control cables pg 4 / 1.12 kptcl sr 21 22 1.12.5 2 core 150 sqmm, providing copper control cables pg 4 / 1.12 kptcl sr 21 22 1.12.4 2 core 50 sqmm, providing copper control cables pg 4 / 1.12 kptcl sr 21 22 1.12.7 4 core 4 sqmm, providing copper control cables pg 4 / 1.12 kptcl sr 21 22 1.12.10 4 core 16 sqmm, providing copper control cables pg 4 / 1.12 kptcl sr 21 22 1.12.10 4 core 25 sqmm, providing copper control cables pg 4 / 1.12 kptcl sr 21 22 1.12.13 7 core 2.5 sqmm, supply of control cables copper core 32 sqmm ( 2 runs of 1 mtr each ) incuding crimping with lugs for battery terminals, supplying of 1.1 kv cable xlpe or heat resistant pvc insulated, pvc extruded inner sheath armoured ug lt cable as per is 1554 ( part 1 ) or is 7098 part 1, armouring strip thickness in average +5% and resistivity 14 ohms / kms ( max ) as per is 3975 ( page no. 09 item no.32 ) bescom sr rs.183442 / per km 32.05: 16 sqmm 4 core ( 11 gi strips 4x0.8mm ) , laying of cable in existing trench / gi pipe / stone ware / rcc hume pipe using wooden / aluminum rollers as directed by the departmental staff lt cable ( page no. 09 item no. 39 ) bescom sr sl no. 230 ) 31.05 ) 2.5 to 25 sqmm, earth work excavation for cable trench of 0.5 to 0.75 mtr. width and depth upto 1 mtr including trial pits, depositing on bank upto a lead of 50 mtr, supplying and displaying necessary danger boards and lighting, using sight rails and sign boards at every 100 mtr wherever necessary as directed. ( page no.07 & item no.29.01 ) 29.03: in hard soil, good quality well burnt charcoal for grounding purposes packed in non returnable gunny bag of 30 kg each. ( item no.54.02 ) . material code : 600095. bescom sr 2022 23., good quality salt for grounding purposes packed in 50 kg gunny bag. ( item no.54.03 ) . material code : 607054. bescom sr 2022 23., ct operated etv meter 0.2 s accuracy with abt feature and dlms protocol with tod with rs 22 port unidirectional used for lt metering cubicle ( 50 150 kw ) bescom sr 21 22 pg 17 item 56.03 ( stock of materials ) , supplying and installation of smart hd ready 32 inches led tv with inbuilt wi fi, lan port and av cable port / hdmi port : make : lg / samsung / sony ) , supplying and installation of smart hd ready 43 inches led tv with inbuilt wi fi, lan port and av cable port / hdmi port : make : lg / samsung / sony ) , supplying and installation of smart hd ready 50 inches led tv with inbuilt wi fi, lan port and av cable port / hdmi port : make : lg / samsung / sony ) , supplying and fixing of advertising full hdled display refresh rate :1920, ac 110volts / 220 volts , 50 / 60 hz, supplying and fixing of 5’x7’ led / lcd projector screen manually operated, water purification plants: supplying, installation and commissioning ofautomatic water purification plant ( ro+uf ) with all accessories piping, product water tank on single phase power supply as per the enclosed detailed technical specifications including cost of material, loading and unloading and as directed by the engineer in charge. ( ref detailed specification enclosed seperatly ) . noteall items are to bwssb sr rates 22 23 ( iso / ce conformity ) cabin type :25lph ro plant, plumbing charges for the installation of ro 25 lph including supplying and fixing of heavy duty taps for the outlet, plumbing charges for the leakage arresting of the solar including the replacement of gaskets with sealant , brazing and welding of the gi pipe for each place of leaking including all labour charges, providing painting ( two coats ) to the bottom frame of the the dg sets including all labour charges and materials, providing plumbing charges for arresting leakages of the inlet and oulet pipes and replacement of any brokened cpvc pipe for solar system, providing high pressure pump 100 gpd for 10 / 12 lph, water purifier including labour and material charges, providing 20 inch jumbo post carbon filters make : kent / live pure, providing 10 inch pre filter make : kent / live pure, providing one time complete servicing of the water purifier including inside and out side cleaning removing of dust and and cleaning entire unit of 25 lph water, providing ro water 100 gpd 24 volt booster pump ( ce / iso certified ) make : kent / live pure, providing complete set of filters for 10 lph ro plant including sediment / pre carbon / post carbon / uf filters make : kent / live pure, providing ro membrane for 10 lph ro water purifier make : live pure / kent, providing 12 / 15 / 18 litres of ro water storage tank including tap ( external storage tank, providing ro membrane for 25 lph ro water purifier make : live pure / kent ( ce / iso / bis certified ) , providing sediment / . pre carbon, post cabon filters for 25 lph ro water purifier at one time make : live pure / kent ( ce / iso / bis ) certified ) , providing uf filter for 25 lph ro water purifier make : kent / live pure ( ce / iso / bis certified ) , providing uf filter for 10 lph ro water purifier make : kent / live pure ( ce / iso / bis ) certified ) , providing media for jumbo water filters sand and carbon for 1000 lph water purification plant 3 bags of sand , 65 bags of activated charcoal for precarbon / post carbon, providing 3500 lph motor for ro plant 500lph / 1000lph including complete installation ( ce / iso certified ) , providing ro membrane for 500 lph ro plant ( ce / iso certified ) , providing ro membrane for 1000 lph ro plant including all materials and labour charges ( ce / iso certified ) , providing raw high pressure pump for 500 lph ro water plant ( ce / iso certified ) stainless steel , vertical / centrifugal multistage, flow rate 2500 litres per hour, power capacity 2 kw , make : sumo / c.r.i including all plumbing charges, providing high pressure pump got 1000 lph ro water plant including all material , labour charges ( ce / iso certified ) providing high pressure pump got 1000 lph ro water plant ( ce / iso certified ) stainless steel , vertical / centrifugal multistage, flow rate 3500 litres per hour, power capacity 2 kw , make : sumo / c.r.i including all plumbing charges, providing complete cleaning charges inside .outside the storage tanks of 500 lph water storage tank , cleaninf of all vessels and complete unit of 500 / 1000 litres of water plant once in a month, providing uv chamber for water purifier 10 / 15 lph make : kent, providing uv chamber for water purifier 25 lph ro water purifier make: kent, providing uv chamber for water purifier 500 / 1000 lph ro water purifier make : kent / live pure, providing 20 inches pre –sediment filter 5 micron, providing 10 inches pre –solid filter catridge poly sting wound sediment make: kent / live pure, supplying and fixing of solenoid for 10 / 25 lph water purifiers, submitting the compliance report to the electrical inspectorate including all commissioning approvals of dg sets / lifts / test reports of earth leakage / transformer testing reports against the observations made by the electrical inspectorate, supplying and fixing of taps for 10 / 25 lpf ro water purifiers, supplying and fixing of heavy duty taps ( steel type ) for 500 / 1000lph water purifiers ( , providing testing and restting of rmus, supplying and fixing of 3 volts lithium batteries for rmus, providing lcd projector lamp for epson make 3500 / 3800 lumens, providing lcd projector lamp for epson make 4000 / 6000 lumens, providing services for lcd projectors including cleaning inside and outside once in 6 months, providing crane services for the replacement of street light fittings at quarters area / kmio campus / pcc kalburgi...

Gulbarga Electricity Supply Company Limited - Karnataka

36874324 tender for supply : 1) pc 1253: lt protection kit, 2) pc 1255: 11kv 400 amps double break gos, 3) pc 1256: 11kv dolo cutout, 4) pc 1257 : lt 2 pin cross arm ms< 4 pin cross arm ms, 5) pc 1258: 11 kv dp sets, 6) pc 1260: anchor rod, 7) pc 1261: 10 swg gi wire, 8) pc 1262: lt line spacer, lt spacers 2 way and lt spacers 4 way, 9) pc 1263 pvc wire 70/95/185/240sqmm. 10) pc 1264: establishment of transformer repair center in gescom jurisdiction and carrying out repairs to faulty 500 kva distribution transformer of gescom. 11) pc 1265: establishment of transformer repair center at yelburga and carrying out repairs of 25/63/100 kva conventional type distribution transformers of o&m sub division, gescom, yelburga as per gescom specifications. short term tenders: 12) pc 1266: establishment of transformer repair center in the jurisdiction o&m zone, gescom, kalaburagi and carrying out repairs to faulty 25/63/100 kva star 1/2 rated distribution transformer of kalaburagi o&m zone. gescom. 13) pc 1267: establishment of transformer repair center in the jurisdiction o&m zone, gescom, ballari and carrying out repairs to faulty 25/63/100 kva star 1/2 rated distribution transformer of ballari o&m zone, gescom, 14) pc 1254:11kv, 200 amps single break gos, 15) pc 1259: 11kv double pole tc sets...

Directorate Of Municipal Administration - Karnataka

36754150 tmc / gf / wss / 1 water supply borewell annual maintenance , for all types ofsubmergible pumpsets upto 3.0 h.p., for all types of submergible pumpsets above 3 hp and upto 5.0 h.p, for all types ofsubmergible pumpsets above 5.0 hp and upto 5.5h.p, for all types of submergible pumpsets above 5.5 hp and upto 6.0h.p, for all types of submergible pumpsets above 6.0 hp and upto 6.5h.p9, for all types of submergible pumpsets above 6.5 hp and upto 7.0h.p, for all types of submergible pumpsets above 7.0 hp and upto 7.5h.p, for all types of submergible pumpsets above 7.5 hp and upto 8.0h.p, for all types of submergible pumpsets above 8.0 hp and upto 8.5h.p, for all types of submergible pumpsets above 8.5 hp and upto 9.0h.p, for all types of submergible pumpsets above 9.0 hp and upto 9.5h.p, for all types of submergible pumpsets above 9.5 hp and upto 10.0h.p, for all types of submergible pumpsets above 10 hp and upto 11 h.p, for all types of submergible pumpsets above 11 hp and upto 12 h.p, for all types of submergible pumpsets above 12 hp and upto 13 h.p, replace the components of submergible pump sets, the bowls of same type and make, replace the components of submergible pump sets, the intermediate piece ( ip ) with ip leaded bronze brush, replace the components of submergible pump sets, the oil seal, replace the components of submergible pump sets, the oil seal.and steel bush, replace the components of submergible pump sets, the guide vane, replace the components of submergible pump sets, the impeller ( shell moulded with aluminium and bronze. ) , replace the components of submergible pump sets, the discharge outlet ( do ) bearing do steel bush do bearing, replace the components of submergible pump sets, the steel bearing bush ( do steel bush ) , replace the components of submergible pump sets, the allen screw, replace the components of submergible pump sets, the pump shaft made out of stainless steel counterless ground with key way ( upto 8 stages ) . extra for each stage rs.40 / , replace the components of submergible pump sets, the pump key ( stainless steel ) , replace the components of submergible pump sets, the pump coupling ( stainless steel ) , replace the components of submergible pump sets, the non return valve ( nrv ) assembly complete with rubber ‘o’ ring., replace the components of submergible pump sets, the cable guard, replace the components of submergible pump sets, the strainer, replace the components of submergible pump sets, the brass filter, the labour charges for overhauling of the pump set., replace the components of motor parts of submergible pump sets, items requiring replacements decided by the departmental officials, the stator of motor 3 to 4 h.p, replace the components of motor parts of submergible pump sets, items requiring replacements decided by the departmental officials, the stator of motor 4 to 5 h.p, replace the components of motor parts of submergible pump sets, items requiring replacements decided by the departmental officials, the rotor of motor upto 3.0 h.p, replace the components of motor parts of submergible pump sets, items requiring replacements decided by the departmental officials, the rotor of motor 3 to 4 h.p, replace the components of motor parts of submergible pump sets, items requiring replacements decided by the departmental officials, the rotor motor 4 to 5 h.p, replace the components of motor parts of submergible pump sets, items requiring replacements decided by the departmental officials, the rotor motor 4 to 5 h.p, replace the components of motor parts of submergible pump sets, items requiring replacements decided by the departmental officials, the upper flange, replace the components of motor parts of submergible pump sets, items requiring replacements decided by the departmental officials, the lower flange, replace the components of motor parts of submergible pump sets, items requiring replacements decided by the departmental officials, upper / lower housing, replace the components of motor parts of submergible pump sets, items requiring replacements decided by the departmental officials, the lock ring, replace the components of motor parts of submergible pump sets, items requiring replacements decided by the departmental officials, the carbon housing, replace the components of motor parts of submergible pump sets, items requiring replacements decided by the departmental officials, the carbon housing ( thrust bearing block assembly complete with segment bearing pad, replace the components of motor parts of submergible pump sets, items requiring replacements decided by the departmental officials, the carbon housing ( top carbond / ferrodo padding ) , replace the components of motor parts of submergible pump sets, items requiring replacements decided by the departmental officials, the stud and nuts, replace the components of motor parts of submergible pump sets, items requiring replacements decided by the departmental officials, the gun metal bearing, centrifugally cast aluminium bronze bearing brush, replace the components of motor parts of submergible pump sets, items requiring replacements decided by the departmental officials, the circlips, replace the components of motor parts of submergible pump sets, items requiring replacements decided by the departmental officials, the motor base with pin, replace the components of motor parts of submergible pump sets, items requiring replacements decided by the departmental officials, the transportation of pumping machineries, the re errection charges of pumping machineries including overhauling and painting, the lifting of submergible pumpset from well, the labour charges only for overhauling, supplying of thermosetting plastic i.e., fibere glass reinforced polyster sheet moulding compound ( smc ) pump house with smc door & canopy etc..., component as directed by the departmental offers, providing, supplying to work site, single phase submersible pump sets of 100mm dia ( 4 inch ) suitable for bore well confirming to is 8034 2000 specifications, with testing of as per instructions of engineer incharge of work and latest amendments. 0.50 hp / 0.37kw 5 stg ( stage ) , providing, supplying to work site, single phase submersible pump sets of 100mm dia ( 4 inch ) suitable for bore well confirming to is 8034 2000 specifications, with testing of as per instructions of engineer incharge of work and latest amendments. 0.50 hp / 0.37kw 7 stg ( stage ) , providing, supplying to work site, single phase submersible pump sets of 100mm dia ( 4 inch ) suitable for bore well confirming to is 8034 2000 specifications, with testing of as per instructions of engineer incharge of work and latest amendments. 0.75 hp / 0.55kw 5 stg, providing, supplying to work site, single phase submersible pump sets of 100mm dia ( 4 inch ) suitable for bore well confirming to is 8034 2000 specifications, with testing of as per instructions of engineer incharge of work and latest amendments. 0.75 hp / 0.55kw 6 stg, providing, supplying to work site, single phase submersible pump sets of 100mm dia ( 4 inch ) suitable for bore well confirming to is 8034 2000 specifications, with testing of as per instructions of engineer incharge of work and latest amendments. 0.75 hp / 0.55kw 7 stg, providing, supplying to work site, single phase submersible pump sets of 100mm dia ( 4 inch ) suitable for bore well confirming to is 8034 2000 specifications, with testing of as per instructions of engineer incharge of work and latest amendments. 0.75 hp / 0.55kw 10 stg, providing, supplying to work site, single phase submersible pump sets of 100mm dia ( 4 inch ) suitable for bore well confirming to is 8034 2000 specifications, with testing of as per instructions of engineer incharge of work and latest amendments. 0.75 hp / 0.55kw 13 stg, providing, supplying to work site, single phase submersible pump sets of 100mm dia ( 4 inch ) suitable for bore well confirming to is 8034 2000 specifications, with testing of as per instructions of engineer incharge of work and latest amendments.1.00 hp / 0.75kw 7 stg, providing, supplying to work site, single phase submersible pump sets of 100mm dia ( 4 inch ) suitable for bore well confirming to is 8034 2000 specifications, with testing of as per instructions of engineer incharge of work and latest amendments.1.00 hp / 0.75kw 10 stg, providing, supplying to work site, single phase submersible pump sets of 100mm dia ( 4 inch ) suitable for bore well confirming to is 8034 2000 specifications, with testing of as per instructions of engineer incharge of work and latest amendments.1.00 hp / 0.75kw 12 stg, providing, supplying to work site, single phase submersible pump sets of 100mm dia ( 4 inch ) suitable for bore well confirming to is 8034 2000 specifications, with testing of as per instructions of engineer incharge of work and latest amendments.1.00 hp / 0.75kw 13 stg, providing, supplying to work site, single phase submersible pump sets of 100mm dia ( 4 inch ) suitable for bore well confirming to is 8034 2000 specifications, with testing of as per instructions of engineer incharge of work and latest amendments.1.00 hp / 0.75kw 18 stg, providing, supplying to work site, single phase submersible pump sets of 100mm dia ( 4 inch ) suitable for bore well confirming to is 8034 2000 specifications, with testing of as per instructions of engineer incharge of work and latest amendments.1.50 hp / 1.1kw 7 stg, providing, supplying to work site, single phase submersible pump sets of 100mm dia ( 4 inch ) suitable for bore well confirming to is 8034 2000 specifications, with testing of as per instructions of engineer incharge of work and latest amendments.1.50 hp / 1.1kw 10 stg, providing, supplying to work site, single phase submersible pump sets of 100mm dia ( 4 inch ) suitable for bore well confirming to is 8034 2000 specifications, with testing of as per instructions of engineer incharge of work and latest amendments.1.50 hp / 1.1kw 12 stg, providing, supplying to work site, single phase submersible pump sets of 100mm dia ( 4 inch ) suitable for bore well confirming to is 8034 2000 specifications, with testing of as per instructions of engineer incharge of work and latest amendments.1.50 hp / 1.1kw 14 stg, providing, supplying to work site, single phase submersible pump sets of 100mm dia ( 4 inch ) suitable for bore well confirming to is 8034 2000 specifications, with testing of as per instructions of engineer incharge of work and latest amendments.1.50 hp / 1.1kw 15 stg, providing, supplying to work site, single phase submersible pump sets of 100mm dia ( 4 inch ) suitable for bore well confirming to is 8034 2000 specifications, with testing of as per instructions of engineer incharge of work and latest amendments.1.50 hp / 1.1kw 18 stg, providing, supplying to work site, single phase submersible pump sets of 100mm dia ( 4 inch ) suitable for bore well confirming to is 8034 2000 specifications, with testing of as per instructions of engineer incharge of work and latest amendments.1.50 hp / 1.1kw 20 stg, providing, supplying to work site, single phase submersible pump sets of 100mm dia ( 4 inch ) suitable for bore well confirming to is 8034 2000 specifications, with testing of as per instructions of engineer incharge of work and latest amendments.1.50 hp / 1.1kw 26 stg, providing, supplying to work site, single phase submersible pump sets of 100mm dia ( 4 inch ) suitable for bore well confirming to is 8034 2000 specifications, with testing of as per instructions of engineer incharge of work and latest amendments. 2.00 hp / 1.5kw 6 stg, providing, supplying to work site, single phase submersible pump sets of 100mm dia ( 4 inch ) suitable for bore well confirming to is 8034 2000 specifications, with testing of as per instructions of engineer incharge of work and latest amendments. 2.00 hp / 1.5kw 10 stg, providing, supplying to work site, single phase submersible pump sets of 100mm dia ( 4 inch ) suitable for bore well confirming to is 8034 2000 specifications, with testing of as per instructions of engineer incharge of work and latest amendments. 2.00 hp / 1.5kw 12 stg, providing, supplying to work site, single phase submersible pump sets of 100mm dia ( 4 inch ) suitable for bore well confirming to is 8034 2000 specifications, with testing of as per instructions of engineer incharge of work and latest amendments. 2.00 hp / 1.5kw 14 stg, providing, supplying to work site, single phase submersible pump sets of 100mm dia ( 4 inch ) suitable for bore well confirming to is 8034 2000 specifications, with testing of as per instructions of engineer incharge of work and latest amendments. 2.00 hp / 1.5kw 15 stg, providing, supplying to work site, single phase submersible pump sets of 100mm dia ( 4 inch ) suitable for bore well confirming to is 8034 2000 specifications, with testing of as per instructions of engineer incharge of work and latest amendments. 2.00 hp / 1.5kw 16 stg, providing, supplying to work site, single phase submersible pump sets of 100mm dia ( 4 inch ) suitable for bore well confirming to is 8034 2000 specifications, with testing of as per instructions of engineer incharge of work and latest amendments. 2.00 hp / 1.5kw 18 stg, providing, supplying to work site, single phase submersible pump sets of 100mm dia ( 4 inch ) suitable for bore well confirming to is 8034 2000 specifications, with testing of as per instructions of engineer incharge of work and latest amendments. 2.00 hp / 1.5kw 20 stg, providing, supplying to work site, single phase submersible pump sets of 100mm dia ( 4 inch ) suitable for bore well confirming to is 8034 2000 specifications, with testing of as per instructions of engineer incharge of work and latest amendments. 2.00 hp / 1.5kw 25 stg, providing, supplying to work site, single phase submersible pump sets of 100mm dia ( 4 inch ) suitable for bore well confirming to is 8034 2000 specifications, with testing of as per instructions of engineer incharge of work and latest amendments. 2.00 hp / 1.5kw 30 stg, providing, supplying to work site, single phase submersible pump sets of 100mm dia ( 4 inch ) suitable for bore well confirming to is 8034 2000 specifications, with testing of as per instructions of engineer incharge of work and latest amendments. 2.00 hp / 1.5kw 35 stg, providing, supplying to work site, single phase submersible pump sets of 100mm dia ( 4 inch ) suitable for bore well confirming to is 8034 2000 specifications, with testing of as per instructions of engineer incharge of work and latest amendments. 3.00 hp / 2.2kw 9 stg, providing, supplying to work site, single phase submersible pump sets of 100mm dia ( 4 inch ) suitable for bore well confirming to is 8034 2000 specifications, with testing of as per instructions of engineer incharge of work and latest amendments. 3.00 hp / 2.2kw 15 stg, providing, supplying to work site, single phase submersible pump sets of 100mm dia ( 4 inch ) suitable for bore well confirming to is 8034 2000 specifications, with testing of as per instructions of engineer incharge of work and latest amendments. 3.00 hp / 2.2kw 20 stg, providing, supplying to work site, single phase submersible pump sets of 100mm dia ( 4 inch ) suitable for bore well confirming to is 8034 2000 specifications, with testing of as per instructions of engineer incharge of work and latest amendments. 3.00 hp / 2.2kw 21 stg, providing, supplying to work site, single phase submersible pump sets of 100mm dia ( 4 inch ) suitable for bore well confirming to is 8034 2000 specifications, with testing of as per instructions of engineer incharge of work and latest amendments.3.00 hp / 2.2kw 23 stg, providing, supplying to work site, single phase submersible pump sets of 100mm dia ( 4 inch ) suitable for bore well confirming to is 8034 2000 specifications, with testing of as per instructions of engineer incharge of work and latest amendments. 3.00 hp / 2.2kw 30 stg, providing, supplying to work site, single phase submersible pump sets of 100mm dia ( 4 inch ) suitable for bore well confirming to is 8034 2000 specifications, with testing of as per instructions of engineer incharge of work and latest amendments. 3.00 hp / 2.2kw 35 stg, providing, supplying to work site, single phase submersible pump sets of 100mm dia ( 4 inch ) suitable for bore well confirming to is 8034 2000 specifications, with testing of as per instructions of engineer incharge of work and latest amendments. 3.00 hp / 2.2kw 40 stg, providing, supplying to work site, single phase submersible pump sets of 100mm dia ( 4 inch ) suitable for bore well confirming to is 8034 2000 specifications, with testing of as per instructions of engineer incharge of work and latest amendments. 3.00 hp / 2.2kw 50 stg, providing, supplying to work site, single phase submersible pump sets of 100mm dia ( 4 inch ) suitable for bore well confirming to is 8034 2000 specifications, with testing of as per instructions of engineer incharge of work and latest amendments. 5.00 hp / 3.7kw 25 stg, providing, supplying to work site, single phase submersible pump sets of 100mm dia ( 4 inch ) suitable for bore well confirming to is 8034 2000 specifications, with testing of as per instructions of engineer incharge of work and latest amendments. 5.00 hp / 3.7kw 30 stg, providing, supplying to work site, single phase submersible pump sets of 100mm dia ( 4 inch ) suitable for bore well confirming to is 8034 2000 specifications, with testing of as per instructions of engineer incharge of work and latest amendments. 5.00 hp / 3.7kw 35 stg, providing, supplying to work site, single phase submersible pump sets of 100mm dia ( 4 inch ) suitable for bore well confirming to is 8034 2000 specifications, with testing of as per instructions of engineer incharge of work and latest amendments. 5.00 hp / 3.7kw 50 stg, providing, supplying to work site, submersible pump set of 150mm dia suitable for bore well and confirming to is 8034 2000;3phase, ss bowl & impeller with low volt motor as per specifications, as per necessary ammendments and instructions of engineer incharge of work. for 3.00 hp 300 lpm 26 m = 2 stg outlet dia 2.50, providing, supplying to work site, submersible pump set of 150mm dia suitable for bore well and confirming to is 8034 2000;3phase, ss bowl & impeller with low volt motor as per specifications, as per necessary ammendments and instructions of engineer incharge of work. for 3.00 hp 155 lpm 42 m = 3 stg outlet dia 2.00, providing, supplying to work site, submersible pump set of 150mm dia suitable for bore well and confirming to is 8034 20003phase, ss bowl & impeller with low volt motor as per specifications, as per necessary ammendments and instructions of engineer incharge of work. for 3.00 hp 135 lpm 56 m 4 stg outlet dia 2.00, providing, supplying to work site, submersible pump set of 150mm dia suitable for bore well and confirming to is 8034 20003phase, ss bowl & impeller with low volt motor as per specifications, as per necessary ammendments and instructions of engineer incharge of work. for 3.00 hp 120 lpm 55 m 5 stg outlet dia 2.00, providing, supplying to work site, submersible pump set of 150mm dia suitable for bore well and confirming to is 8034 20003phase, ss bowl & impeller with low volt motor as per specifications, as per necessary ammendments and instructions of engineer incharge of work. for 3.00 hp 90 lpm 66 m 6 stg outlet dia 2.00, providing, supplying to work site, submersible pump set of 150mm dia suitable for bore well and confirming to is 8034 20003phase, ss bowl & impeller with low volt motor as per specifications, as per necessary ammendments and instructions of engineer incharge of work. for 4.00 hp 360 lpm 30 m 2 stg outlet dia 3.00, providing, supplying to work site, submersible pump set of 150mm dia suitable for bore well and confirming to is 8034 20003phase, ss bowl & impeller with low volt motor as per specifications, as per necessary ammendments and instructions of engineer incharge of work. for 4.00 hp 245 lpm 42 m 3 stg outlet dia 2.50, providing, supplying to work site, submersible pump set of 150mm dia suitable for bore well and confirming to is 8034 20003phase, ss bowl & impeller with low volt motor as per specifications, as per necessary ammendments and instructions of engineer incharge of work. for 4.00 hp 155 lpm 56 m 4 stg outlet dia 2.00, providing, supplying to work site, submersible pump set of 150mm dia suitable for bore well and confirming to is 8034 20003phase, ss bowl & impeller with low volt motor as per specifications, as per necessary ammendments and instructions of engineer incharge of work. for 4.00 hp 135 lpm 70 m 5 stg outlet dia 2.00, providing, supplying to work site, submersible pump set of 150mm dia suitable for bore well and confirming to is 8034 20003phase, ss bowl & impeller with low volt motor as per specifications, as per necessary ammendments and instructions of engineer incharge of work. for 4.00 hp 120 lpm 77 m 7 stg outlet dia 2.00, providing, supplying to work site, submersible pump set of 150mm dia suitable for bore well and confirming to is 8034 20003phase, ss bowl & impeller with low volt motor as per specifications, as per necessary ammendments and instructions of engineer incharge of work. for 4.00 hp 90 lpm 88 m 8 stg outlet dia 2.00, providing, supplying to work site, submersible pump set of 150mm dia suitable for bore well and confirming to is 8034 20003phase, ss bowl & impeller with low volt motor as per specifications, as per necessary ammendments and instructions of engineer incharge of work. for 5.00 hp 300 lpm 39 m 3 stg outlet dia 2.50, providing, supplying to work site, submersible pump set of 150mm dia suitable for bore well and confirming to is 8034 20003phase, ss bowl & impeller with low volt motor as per specifications, as per necessary ammendments and instructions of engineer incharge of work. for 5.00 hp 245 lpm 56 m 4 stg outlet dia 2.50, providing, supplying to work site, submersible pump set of 150mm dia suitable for bore well and confirming to is 8034 20003phase, ss bowl & impeller with low volt motor as per specifications, as per necessary ammendments and instructions of engineer incharge of work. for 5.00 hp 155 lpm 70 m 5 stg outlet dia 2.00, providing, supplying to work site, submersible pump set of 150mm dia suitable for bore well and confirming to is 8034 20003phase, ss bowl & impeller with low volt motor as per specifications, as per necessary ammendments and instructions of engineer incharge of work. for 5.00 hp 135 lpm 84 m 6 stg outlet dia 2.00, providing, supplying to work site, submersible pump set of 150mm dia suitable for bore well and confirming to is 8034 20003phase, ss bowl & impeller with low volt motor as per specifications, as per necessary ammendments and instructions of engineer incharge of work. for 5.00 hp 120 lpm 88 m 8 stg outlet dia 2.00, providing, supplying to work site, submersible pump set of 150mm dia suitable for bore well and confirming to is 8034 20003phase, ss bowl & impeller with low volt motor as per specifications, as per necessary ammendments and instructions of engineer incharge of work. for 5.00 hp 90 lpm 110 m 10 stg outlet dia 2.00, providing, supplying to work site, submersible pump set of 150mm dia suitable for bore well and confirming to is 8034 20003phase, ss bowl & impeller with low volt motor as per specifications, as per necessary ammendments and instructions of engineer incharge of work. for 6.50 hp 360 lpm 45 m 3 stg outlet dia 3.00, providing, supplying to work site, submersible pump set of 150mm dia suitable for bore well and confirming to is 8034 20003phase, ss bowl & impeller with low volt motor as per specifications, as per necessary ammendments and instructions of engineer incharge of work. for 6.50 hp 300 lpm 52 m 4 stg outlet dia 2.50, providing, supplying to work site, submersible pump set of 150mm dia suitable for bore well and confirming to is 8034 20003phase, ss bowl & impeller with low volt motor as per specifications, as per necessary ammendments and instructions of engineer incharge of work. for 6.50 hp 245 lpm 70 m 5 stg outlet dia 2.50, providing, supplying to work site, submersible pump set of 150mm dia suitable for bore well and confirming to is 8034 20003phase, ss bowl & impeller with low volt motor as per specifications, as per necessary ammendments and instructions of engineer incharge of work. for 6.50 hp 155 lpm 84 m 6 stg outlet dia 2.00, providing, supplying to work site, submersible pump set of 150mm dia suitable for bore well and confirming to is 8034 20003phase, ss bowl & impeller with low volt motor as per specifications, as per necessary ammendments and instructions of engineer incharge of work. for 6.50 hp 135 lpm 110 m 8 stg outlet dia 2.00, providing, supplying to work site, submersible pump set of 150mm dia suitable for bore well and confirming to is 8034 20003phase, ss bowl & impeller with low volt motor as per specifications, as per necessary ammendments and instructions of engineer incharge of work. for 6.50 hp 120 lpm 112 m 10 stg outlet dia 2.00, providing, supplying to work site, submersible pump set of 150mm dia suitable for bore well and confirming to is 8034 20003phase, ss bowl & impeller with low volt motor as per specifications, as per necessary ammendments and instructions of engineer incharge of work. for 6.50 hp 90 lpm 132 m 12 stg outlet dia 2.00, providing, supplying to work site, submersible pump set of 150mm dia suitable for bore well and confirming to is 8034 20003phase, ss bowl & impeller with low volt motor as per specifications, as per necessary ammendments and instructions of engineer incharge of work. for 7.50 hp 360 lpm 60 m 4 stg outlet dia 3.00, providing, supplying to work site, submersible pump set of 150mm dia suitable for bore well and confirming to is 8034 20003phase, ss bowl & impeller with low volt motor as per specifications, as per necessary ammendments and instructions of engineer incharge of work. for 7.50 hp 300 lpm 65 m 5 stg outlet dia 2.50, providing, supplying to work site, submersible pump set of 150mm dia suitable for bore well and confirming to is 8034 20003phase, ss bowl & impeller with low volt motor as per specifications, as per necessary ammendments and instructions of engineer incharge of work. for 7.50 hp 245 lpm 84 m 6 stg outlet dia 2.50, providing, supplying to work site, submersible pump set of 150mm dia suitable for bore well and confirming to is 8034 20003phase, ss bowl & impeller with low volt motor as per specifications, as per necessary ammendments and instructions of engineer incharge of work. for 7.50 hp 155 lpm 112 m 8 stg outlet dia 2.00, providing, supplying to work site, submersible pump set of 150mm dia suitable for bore well and confirming to is 8034 20003phase, ss bowl & impeller with low volt motor as per specifications, as per necessary ammendments and instructions of engineer incharge of work. for 7.50 hp 135 lpm 140 m 10 stg outlet dia 2.00, providing, supplying to work site, submersible pump set of 150mm dia suitable for bore well and confirming to is 8034 20003phase, ss bowl & impeller with low volt motor as per specifications, as per necessary ammendments and instructions of engineer incharge of work. for 7.50 hp 120 lpm 132 m 12 stg outlet dia 2.00, providing, supplying to work site, submersible pump set of 150mm dia suitable for bore well and confirming to is 8034 20003phase, ss bowl & impeller with low volt motor as per specifications, as per necessary ammendments and instructions of engineer incharge of work. for 7.50 hp 90 lpm 165 m 15 stg outlet dia 2.00, providing, supplying to work site, submersible pump set of 150mm dia suitable for bore well and confirming to is 8034 20003phase, ss bowl & impeller with low volt motor as per specifications, as per necessary ammendments and instructions of engineer incharge of work. for 10.00 hp 360 lpm 75 m 5 stg outlet dia 3.00, providing, supplying to work site, submersible pump set of 150mm dia suitable for bore well and confirming to is 8034 20003phase, ss bowl & impeller with low volt motor as per specifications, as per necessary ammendments and instructions of engineer incharge of work. for 10.00 hp 300 lpm 91 m 7 stg outlet dia 2.50, providing, supplying to work site, submersible pump set of 150mm dia suitable for bore well and confirming to is 8034 20003phase, ss bowl & impeller with low volt motor as per specifications, as per necessary ammendments and instructions of engineer incharge of work. for 10.00 hp 245 lpm 112 m 8 stg outlet dia 2.50, providing, supplying to work site, submersible pump set of 150mm dia suitable for bore well and confirming to is 8034 20003phase, ss bowl & impeller with low volt motor as per specifications, as per necessary ammendments and instructions of engineer incharge of work. for 10.00 hp 155 lpm 140 m 10 stg outlet dia 2.00, providing, supplying to work site, submersible pump set of 150mm dia suitable for bore well and confirming to is 8034 20003phase, ss bowl & impeller with low volt motor as per specifications, as per necessary ammendments and instructions of engineer incharge of work. for 10.00 hp 135 lpm 168 m 12 stg outlet dia 2.00, providing, supplying to work site, submersible pump set of 150mm dia suitable for bore well and confirming to is 8034 20003phase, ss bowl & impeller with low volt motor as per specifications, as per necessary ammendments and instructions of engineer incharge of work. for 10.00 hp 120 lpm 176 m 16 stg outlet dia 2.00, providing, supplying to work site, submersible pump set of 150mm dia suitable for bore well and confirming to is 8034 20003phase, ss bowl & impeller with low volt motor as per specifications, as per necessary ammendments and instructions of engineer incharge of work. for 10.00 hp 90 lpm 220 m 20 stg outlet dia 2.00, providing, supplying to work site, submersible pump set of 150mm dia suitable for bore well and confirming to is 8034 20003phase, ss bowl & impeller with low volt motor as per specifications, as per necessary ammendments and instructions of engineer incharge of work. for 12.50 hp 360 lpm 90 m 6 stg outlet dia 3.00, providing, supplying to work site, submersible pump set of 150mm dia suitable for bore well and confirming to is 8034 20003phase, ss bowl & impeller with low volt motor as per specifications, as per necessary ammendments and instructions of engineer incharge of work. for 12.50 hp 300 lpm 104 m 8 stg outlet dia 2.50, providing, supplying to work site, submersible pump set of 150mm dia suitable for bore well and confirming to is 8034 20003phase, ss bowl & impeller with low volt motor as per specifications, as per necessary ammendments and instructions of engineer incharge of work. for 12.50 hp 245 lpm 140 m 10 stg outlet dia 2.50, providing, supplying to work site, submersible pump set of 150mm dia suitable for bore well and confirming to is 8034 20003phase, ss bowl & impeller with low volt motor as per specifications, as per necessary ammendments and instructions of engineer incharge of work. for 12.50 hp 155 lpm 168 m 12 stg outlet dia 2.00, providing, supplying to work site, submersible pump set of 150mm dia suitable for bore well and confirming to is 8034 20003phase, ss bowl & impeller with low volt motor as per specifications, as per necessary ammendments and instructions of engineer incharge of work. for 12.50 hp 135 lpm 210 m 15 stg outlet dia 2.00, providing, supplying to work site, submersible pump set of 150mm dia suitable for bore well and confirming to is 8034 20003phase, ss bowl & impeller with low volt motor as per specifications, as per necessary ammendments and instructions of engineer incharge of work. for 12.50 hp 120 lpm 220 m 20 stg outlet dia 2.00, providing, supplying to work site, submersible pump set of 150mm dia suitable for bore well and confirming to is 8034 20003phase, ss bowl & impeller with low volt motor as per specifications, as per necessary ammendments and instructions of engineer incharge of work. for 12.50 hp 90 lpm 264 m 24 stg outlet dia 2.00, providing, supplying to work site, submersible pump set of 150mm dia suitable for bore well and confirming to is 8034 20003phase, ss bowl & impeller with low volt motor as per specifications, as per necessary ammendments and instructions of engineer incharge of work. for 15.00 hp 360 lpm 120 m 8 stg outlet dia 3.00, providing, supplying to work site, submersible pump set of 150mm dia suitable for bore well and confirming to is 8034 20003phase, ss bowl & impeller with low volt motor as per specifications, as per necessary ammendments and instructions of engineer incharge of work. for 15.00 hp 300 lpm 130 m 10 stg outlet dia 2.50, providing, supplying to work site, submersible pump set of 150mm dia suitable for bore well and confirming to is 8034 20003phase, ss bowl & impeller with low volt motor as per specifications, as per necessary ammendments and instructions of engineer incharge of work. for 15.00 hp 245 lpm 168 m 12 stg outlet dia 2.50, providing, supplying to work site, submersible pump set of 150mm dia suitable for bore well and confirming to is 8034 20003phase, ss bowl & impeller with low volt motor as per specifications, as per necessary ammendments and instructions of engineer incharge of work. for 15.00 hp 155 lpm 210 m 15 stg outlet dia 2.00, providing, supplying to work site, submersible pump set of 150mm dia suitable for bore well and confirming to is 8034 20003phase, ss bowl & impeller with low volt motor as per specifications, as per necessary ammendments and instructions of engineer incharge of work. for 15.00 hp 135 lpm 253 m 19 stg outlet dia 2.00, providing, supplying to work site, submersible pump set of 150mm dia suitable for bore well and confirming to is 8034 20003phase, ss bowl & impeller with low volt motor as per specifications, as per necessary ammendments and instructions of engineer incharge of work. for 15.00 hp 120 lpm 266 m 23 stg outlet dia 2.00, providing, supplying to work site, submersible pump set of 150mm dia suitable for bore well and confirming to is 8034 20003phase, ss bowl & impeller with low volt motor as per specifications, as per necessary ammendments and instructions of engineer incharge of work. for 17.50 hp 360 lpm 135 m 9 stg outlet dia 3.00, providing, supplying to work site, submersible pump set of 150mm dia suitable for bore well and confirming to is 8034 20003phase, ss bowl & impeller with low volt motor as per specifications, as per necessary ammendments and instructions of engineer incharge of work. for 17.50 hp 300 lpm 156 m 12 stg outlet dia 2.50, providing, supplying to work site, submersible pump set of 150mm dia suitable for bore well and confirming to is 8034 20003phase, ss bowl & impeller with low volt motor as per specifications, as per necessary ammendments and instructions of engineer incharge of work. for 17.50 hp 245 lpm 196 m 14 stg outlet dia 2.50, providing, supplying to work site, submersible pump set of 150mm dia suitable for bore well and confirming to is 8034 20003phase, ss bowl & impeller with low volt motor as per specifications, as per necessary ammendments and instructions of engineer incharge of work. for 17.50 hp 155 lpm 252 m 18 stg outlet dia 2.00, providing, supplying to work site, submersible pump set of 150mm dia suitable for bore well and confirming to is 8034 20003phase, ss bowl & impeller with low volt motor as per specifications, as per necessary ammendments and instructions of engineer incharge of work. for 17.50 hp 135 lpm 286 m 22 stg outlet dia 2.00, providing, supplying to work site, submersible pump set of 150mm dia suitable for bore well and confirming to is 8034 20003phase, ss bowl & impeller with low volt motor as per specifications, as per necessary ammendments and instructions of engineer incharge of work. for 17.50 hp 120 lpm 308 m 26 stg outlet dia 2.00, providing, supplying to work site, submersible pump set of 150mm dia suitable for bore well and confirming to is 8034 20003phase, ss bowl & impeller with low volt motor as per specifications, as per necessary ammendments and instructions of engineer incharge of work. for 20.00 hp 360 lpm 150 m 10 stg outlet dia 3.00, providing, supplying to work site, submersible pump set of 150mm dia suitable for bore well and confirming to is 8034 20003phase, ss bowl & impeller with low volt motor as per specifications, as per necessary ammendments and instructions of engineer incharge of work. for 20.00 hp 300 lpm 169 m 13 stg outlet dia 2.50, providing, supplying to work site, submersible pump set of 150mm dia suitable for bore well and confirming to is 8034 20003phase, ss bowl & impeller with low volt motor as per specifications, as per necessary ammendments and instructions of engineer incharge of work. for 20.00 hp 245 lpm 224 m 16 stg outlet dia 2.50, providing, supplying to work site, submersible pump set of 150mm dia suitable for bore well and confirming to is 8034 20003phase, ss bowl & impeller with low volt motor as per specifications, as per necessary ammendments and instructions of engineer incharge of work. for 20.00 hp 155 lpm 280 m 20 stg outlet dia 2.00, providing, supplying to work site, submersible pump set of 150mm dia suitable for bore well and confirming to is 8034 20003phase, ss bowl & impeller with low volt motor as per specifications, as per necessary ammendments and instructions of engineer incharge of work. for 20.00 hp 135 lpm 350 m 25 stg outlet dia 2.00, providing, supplying to work site, submersible pump set of 150mm dia suitable for bore well and confirming to is 8034 20003phase, ss bowl & impeller with low volt motor as per specifications, as per necessary ammendments and instructions of engineer incharge of work. for 25.00 hp 360 lpm 195 m 13 stg outlet dia 3.00, providing, supplying to work site, submersible pump set of 150mm dia suitable for bore well and confirming to is 8034 20003phase, ss bowl & impeller with low volt motor as per specifications, as per necessary ammendments and instructions of engineer incharge of work. for 25.00 hp 300 lpm 221 m 17 stg outlet dia 2.50, providing, supplying to work site, submersible pump set of 150mm dia suitable for bore well and confirming to is 8034 20003phase, ss bowl & impeller with low volt motor as per specifications, as per necessary ammendments and instructions of engineer incharge of work. for 25.00 hp 245 lpm 280 m 20 stg outlet dia 2.50, providing, supplying to work site, submersible pump set of 150mm dia suitable for bore well and confirming to is 8034 20003phase, ss bowl & impeller with low volt motor as per specifications, as per necessary ammendments and instructions of engineer incharge of work. for 25.00 hp 155 lpm 280 m 20 stg outlet dia 2.00, providing, supplying to work site, submersible pump set of 150mm dia suitable for bore well and confirming to is 8034 20003phase, ss bowl & impeller with low volt motor as per specifications, as per necessary ammendments and instructions of engineer incharge of work. for 25.00 hp 135 lpm 420 m 30 stg outlet dia 2.00, supply and delivery at site brand new best make pvc insulated cable of flat 3 core ( sheathed ) of nominal cross sectional area as per is 694 1990 with isi mark and as per its latest amendments. 1x3x1.5 m2 m 75, supply and delivery at site brand new best make pvc insulated cable of flat 3 core ( sheathed ) of nominal cross sectional area as per is 694 1990 with isi mark and as per its latest amendments. 1x3x2.5 m2 m 98, supply and delivery at site brand new best make pvc insulated cable of flat 3 core ( sheathed ) of nominal cross sectional area as per is 694 1990 with isi mark and as per its latest amendments. 1x3x4 m2 m 165, supply and delivery at site brand new best make pvc insulated cable of flat 3 core ( sheathed ) of nominal cross sectional area as per is 694 1990 with isi mark and as per its latest amendments. 1x3x6 m2 m 210, supply and delivery at site brand new best make pvc insulated cable of flat 3 core ( sheathed ) of nominal cross sectional area as per is 694 1990 with isi mark and as per its latest amendments. 1x3x10 m2 m 290, supply and delivery at site of brand new best make pressure gauge bourdon type as per is 778 / 1984 with isi mark and as per its latest amendments. size 63 mm, supply and delivery at site of brand new best make pressure gauge bourdon type as per is 778 / 1984 with isi mark and as per its latest amendments. size 80 mm, supply and delivery at site of brand new best make pressure gauge bourdon type as per is 778 / 1984 with isi mark and as per its latest amendments. size 100 mm, supply and delivery at site of brand new best make gate valve as per is 778 / 1984 with isi mark and as per its latest amendments size 50 mm, supply and delivery at site of brand new best make gate valve as per is 778 / 1984 with isi mark and as per its latest amendments size 65 mm, supply and delivery at site of brand new best make gate valve as per is 778 / 1984 with isi mark and as per its latest amendments size 80 mm, supply and delivery at site of brand new best make non return valve as per is 778 / 1984 with isi mark and as per its latest amendments size 50 mm, supply and delivery at site of brand new best make non return valve as per is 778 / 1984 with isi mark and as per its latest amendments size 65 mm, supply and delivery at site of brand new best make non return valve as per is 778 / 1984 with isi mark and as per its latest amendments size 80 mm, supply, installing, testing and commissioning common control panel consisting of the following incoming:1 no set of phase indicating lamps with sfu of suitable rating 1 no, analog ammeter, 1 no analog voltmeter 1ni with phase selector switch, isolating switch outgoing for main electrical pump: 1 no. mcb 1 no. dol of s / d starter suitable for respective hp 1 no. electrcal protection like single phase preventor, under voltage over volage, under current over current & dry run protection suitable for the pump described above 1 no indoor type note: 1 ) doldirect online starter 2 ) s d star delta starter upto 6 hp pumps, supply, installing, testing and commissioning common control panel consisting of the following incoming:1 no set of phase indicating lamps with sfu of suitable rating 1 no, analog ammeter, 1 no analog voltmeter 1ni with phase selector switch, isolating switch outgoing for main electrical pump: 1 no. mcb 1 no. dol of s / d starter suitable for respective hp 1 no. electrcal protection like single phase preventor, under voltage over volage, under current over current & dry run protection suitable for the pump described above 1 no indoor type note: 1 ) doldirect online starter 2 ) s d star delta starter 6 to 15 hp pumps, supply, installing, testing and commissioning common control panel consisting of the following incoming:1 no set of phase indicating lamps with sfu of suitable rating 1 no, analog ammeter, 1 no analog voltmeter 1ni with phase selector switch, isolating switch outgoing for main electrical pump: 1 no. mcb 1 no. dol of s / d starter suitable for respective hp 1 no. electrcal protection like single phase preventor, under voltage over volage, under current over current & dry run protection suitable for the pump described above 1 no outdoor type note: 1 ) doldirect online starter 2 ) s d star delta starter upto 6 hp pumps, supply, installing, testing and commissioning common control panel consisting of the following incoming:1 no set of phase indicating lamps with sfu of suitable rating 1 no, analog ammeter, 1 no analog voltmeter 1ni with phase selector switch, isolating switch outgoing for main electrical pump: 1 no. mcb 1 no. dol of s / d starter suitable for respective hp 1 no. electrcal protection like single phase preventor, under voltage over volage, under current over current & dry run protection suitable for the pump described above 1 no outdoor type note: 1 ) doldirect online starter 2 ) s d star delta starter 6 to 15 hp pumps, supply and delivery at site best indigenous brand new power capacitor as per is 2834 / 1986 with latest amendments with kptcl authorities and erection, electrification and commissioning of the same at the location of respective pump sets., supply and delivery at site delivery of best indigenous brand new mcb ( miniature circuit breakers ) of required capacity as per is 88228 / 1978 and its latest amendments and with isi mark of 6 / 10 / 16 / 20 / 25 / 40 amps with scalable box., supply and delivery of galvanized mild steel tubes of 6mtr standard length heavy duty ( c class ) as per is 1239 ( part i ) 1990 with latest amendments with isi mark ( one end fitted with heavy duty collar and other end fitted with protective cover ) 50 mm, supply and delivery of galvanized mild steel tubes of 6mtr standard length heavy duty ( c class ) as per is 1239 ( part i ) 1990 with latest amendments with isi mark ( one end fitted with heavy duty collar and other end fitted with protective cover ) 65 mm, supply and delivery of galvanized mild steel tubes of 6mtr standard length heavy duty ( c class ) as per is 1239 ( part i ) 1990 with latest amendments with isi mark ( one end fitted with heavy duty collar and other end fitted with protective cover ) 80 mm, supply and delivery at site 50mm ( 2” ) dia heavy duty unplasticized pvc column pipes with heavy duty collars, rubber profile ring, vibration control profile ring, freezing and turbulence free leak proof epdm ring with isi mark with its latest amendments, supply and delivery at site 50mm ( 2 ) dia heavy duty ci adopter set complete suitable for upvc column pipes for submersible pumpsets set 1650, supply and delivery at site accessories for single phase pumpset like ss groove nipples, ss studs & nuts, screw clips &water proof insulation tape etc complete with isi mark, supply and delivery at site stringing of heavy duty naylone / pp rope with isi etc complete suitable for single phase pumpsets. job 40, labour charges for erection, electrification and commissioning of pump sets, including aligning and balancing of all items including supply and erection of two pair of supporting clamps, bore well caps, cable clips and water tight gland cable protectors, bolts, nuts, valve and gauges, tools and equipments etc., involved in the job as per specifications, with necessary tests as per specifications, with testing of as per instructions of engineer incharge of work., labour charges for erection of indoor type panel board and meter board units with all necessary materials and labour tools and equipments including cement concrete for foundation / bed etc, complete as per specification, with testing of as per instructions of engineer incharge of work., labour charges for erection of outdoor type panel board and meter board units with all necessary materials and labour, tools and equipments including providing cement concrete foundation bed etc., complete as per specification, with testing of as per instructions of engineer incharge of work., labour charges for providing connection using insulated sheathed steel wire cable as per is 1554 / 1988 with latest amendments from kptcl pole to meter board unit, with all necessary materials , tools and equipments, as per specificationswith testing of as per instructions of engineer incharge of work. 3.5 x 6 sqmm, labour charges for providing connection using insulated sheathed steel wire cable as per is 1554 / 1988 with latest amendments from kptcl pole to meter board unit, with all necessary materials , tools and equipments, as per specificationswith testing of as per instructions of engineer incharge of work. 3.5x 10 sqmm, labour charges for providing connection using insulated sheathed steel wire cable as per is 1554 / 1988 with latest amendments from kptcl pole to meter board unit, with all necessary materials , tools and equipments, as per specificationswith testing of as per instructions of engineer incharge of work. 3 x 10 sqmm ( suitable for over head mains ) , labour charges for providing connection using insulated sheathed steel wire cable as per is 1554 / 1988 with latest amendments from kptcl pole to meter board unit, with all necessary materials , tools and equipments, as per specificationswith testing of as per instructions of engineer incharge of work. 3.5 x 16 sqmm, providing main connection from pole pvc insulated sheathed steel wire cable in new trench as per is 1554 / 1988 with latest amendments with isi mark from kptcl pole to meter board unit., providing main connection from pole pvc insulated sheathed steel wire cable in gi pipe as per is 1554 / 1988 with latest amendments with isi mark from kptcl pole to meter board unit., providing, supplying and fixing suitable for 1.1 kv class ug cable filled with necessary bitumen / insulating compound complete with terminals, clamps, bolts, nuts and washers etc. with necessary materials and labour tools and equipments as per instructions of engineer incharge of work. 3.5x6 sqm, providing, supplying and fixing suitable for 1.1 kv class ug cable filled with necessary bitumen / insulating compound complete with terminals, clamps, bolts, nuts and washers etc. with necessary materials and labour tools and equipments as per instructions of engineer incharge of work. 3.5x10 sqm, providing, supplying and fixing suitable for 1.1 kv class ug cable filled with necessary bitumen / insulating compound complete with terminals, clamps, bolts, nuts and washers etc. with necessary materials and labour tools and equipments as per instructions of engineer incharge of work. 3.5x25 sqm, earthing: supplying and fixing and wiring earth electrode for grounding circuits ic cutouts and other equipments on the meter board in the pit.the pits should be filled up with equal proportion of salt and charcoal 150mm around the pipe to complete depth. the connection from the pipe to the conduits etc. is to established through gi wire of sizes as per clause 7.3.3 of is 732 using 12mm bolts, nuts, washers and check nuts, the pipe shall have 16 through holes of 12mm dia., supply and delivery of centrifugal pumpset at site brand new best make and with discharge duty confirming to isi standards and its latest amendments. 2 hp, size 65x50 head 13m, discharge 462 lpm, supply and delivery of centrifugal pumpset at site brand new best make and with discharge duty confirming to isi standards and its latest amendments. 2 hp, size 50x40 head 22m, discharge 186 lpm, supply and delivery of centrifugal pumpset at site brand new best make and with discharge duty confirming to isi standards and its latest amendments. 3 hp, size 50x40 head 30m, discharge 198 lpm, supply and delivery of centrifugal pumpset at site brand new best make and with discharge duty confirming to isi standards and its latest amendments. 5 hp, size 80x65 head 23.50m, discharge 600 lpm, supply and delivery at site brand new best make pressure guage suitable for centrifugal pump confirming to latest is standards. pressure guage 80mm, supply and delivery at site brand new best make pressure guage suitable for centrifugal pump confirming to latest is standards. pressure guage 100mm, supply and delivery at site brand new best make level guage suitable for centrifugal pump confirming to latest is standards. upto 7.5 hp centrifugal pump, supply and delivery at site brand new best make level guage suitable for centrifugal pump confirming to latest is standards. 7.5 to 10 hp centrifugal pump, supply and delivery at site brand new best make level guage suitable for centrifugal pump confirming to latest is standards. 10 to 120 hp centrifugal pump, supply, delivery, erection and commissioning at site lighting distribution board suitable for monoblock centrifugal pump confirming with isi mark and its latest amendments., supply, delivery, erection and commissioning at site elcb suitable for monoblock centrifugal pump confirming with isi mark and its latest amendments., supplying and fixing lt cable of size 4 x 25 sqm suitable for centrifugal pump sets with isi mark and its latest amendments., supply and delivery at site brand new best make foot valve suitable for centrifugal pump upto 10hp confirming with isi mark and its latest, supply and delivery at site brand new best make foot valve suitable for centrifugal pump above 12.50hp confirming with isi mark and its latest rewinding of monoblock motor with copper insulaton wire suitable gauge equipments with guarantee period of not less than 12 months, 7.5 hp monobloc motor rewinding, 10 hp monobloc motor rewinding, 12.5 hp monobloc motor rewinding, 15 hp monobloc motor rewinding, 20 hp monobloc motor rewinding, bearing cost for 7.5 hp, bearing cost for 10hp, bearing cost for 12.5 hp...

Karnataka Power Transmission Corporation Limited - Karnataka

36516573 combined package for strengthening of the existing earthing system by providing additional ci pipes & by replacing existing gi pipes by ci pipes & gi wires by gi flats at in kiadb mandya & mandya in mandya taluk, mandya dist on ptk basis....

Karnataka Power Transmission Corporation Limited - Karnataka

36515725 combined package for strengthening of the existing earthing system by providing additional ci pipes & by replacing existing gi pipes by ci pipes & gi wires by gi flats at in km doddi, kirugavalu & maddur in maddur taluk, mandya dist on ptk basis...

Indian Army - Karnataka

36481488 bids are invited for french polish , gi wire mesh , gland packing but 15 mm , 4 mm thick glass pans , male threaded adapter 20x15 mm , male threaded adapter 20x20 mm , male threaded adapter 25x25 mm , male threaded adapter 15x15 mm , male threaded adapter plastic 15 mm , male threaded adapter plastic 20 mm , male threaded adapter plastic 25 mm , nails wire 100 mm , nails 1 inch , nails 1.5 inch , nails 2 inch , nails wire 125 x 5.8 mm , nails wire 25 x 2 mm , nails wire 30 x 2 mm , nails wire 40 x 2 mm , nails wire 50 x 2.28 mm , nails wire 50 x 3.2 mm , nails wire 65 x 3.2 mm , nails wire 75 x 4 mm , oil putty , floor paint , paint red , primer , screw 10 mm , screw 20 mm , screw 25 mm , thinner , upvc coupler 15 mm , upvc coupler 20 mm , upvc coupler 25 mm , upvc elbow 15 mm , upvc elbow 20 mm , upvc elbow 25 mm , upvc end cap 15 mm , upvc end cap 20 mm , upvc end cap 25 mm , upvc equal tee 15 mm , upvc equal tee 20 mm , upvc equal tee 25 mm , upvc pipe sch 40 15 mm , upvc pipe sch 40 20 mm , upvc pipe sch 40 25 mm , upvc union 15 mm , upvc union 20 mm , upvc union 25 mm total quantity : 1742...

Indian Army - Karnataka

36213620 bids are invited for ptz camera , 8 channel dvr , cat 6 cable , 4 tb ssd hdd , camera extension , signal booster , u rack box , 43 inch led display unit wall mounting stand , wire connectors , gi wire , 8 channel smps for ptz camera , casing pipe , 8 port poe switch , hdmi cable , splitters for camera total quantity : 1856...

South Western Railway - Karnataka

36207435 auction sale of [pl no.98090800] scrap/cond/released/ rusted bazaar scrap such as disintegrated thorough rust corrugated sheets, pots, berth ladders, springs cutting hup iron, gurrah, mortar pans, buckets, oil tanks, coal tubes, un sound/corroded paint drums/tar/oil/grease barrels containing with/without paint/oil/tar, water strainer, bail putty, corroded commode chutes, name disply board, punjas, destination board, bearing collers, tins, sheets, packing sheets, corroded battery boxes/ sheets/ released u type sheets of different sizes and lengths, corroded dust shield springs, fencing wire, oil filters, packing bands, rusted gi wire, knitting, iron mesh, corroded zinc sheet/ fabricated materials, corroded grs boxes, gi/ms wire/rope , alphabetic location boards, fully corroded tl fan/tube fittings, panel boards, broken fire extinguishers, and other items coming under bazaar scrap on as is where is condition available under the custody of cdms 08 ward ap. (pressing permitted) ( loc: bin no 110 at scarp yard.special conditions: during delivery, selection, sorting, rejection of part or partial lot will not be entertained. picking, disturbing of other nearby lots, undefined materials near lot or under lot formation materials will not be entertained. purchaser may survey materials before bidding into auction, after successful bid further queries or objection will not be entertained...

Karnataka State Electronics Development Corporation Limited - Karnataka

36055218 supply & installation of ip based cctv system , lt electrical works pvc conduits & its accessories a) 25mm dia 2mm thick,lt electrical works pvc conduits & its accessories b) 32mm dia 2.5mm thick,lt electrical works pvc conduits & its accessories c) 40mm dia 2.5mm thick,1/3 progressive scan cmos, 5.0 megapixel, ip based colour camera,poe switches 4/6 port giga switch,poe switches 8 port giga switch,poe switches (12 port ),nvr (networkable video recorder) 32 channel nvr, up to 32ch ip cameras input with all necessary accessories,nvr (networkable video recorder) 16 channel nvr, up to 16ch ip cameras input, up to with all necessary accessories.,i3 cpu with 4gb ram + 8gb hard disk with key board & mouse,camera braclets with back box,media converter single port with of c sfp,media converter outdoor box pole mount or wall mount,wall mount 6u rack,electrical mcb with panel,cable (cat6 data cable utp armounted ofc cable),cable (cat 6 data cable utp amounted ),cable (cat6 data cable utp shleided),gi metal poles 12 to 15 feet with nut boit system aling with earthing material,rj45 connectors with pvc cap,female cat 6 io connectors,gi wire 8 guage for earthing,4k led 65 inch tv display (uv make),2.5sqmm 3 core armoured power cable,ofc termination outdoor encloser box,2 module with switch and 3 pin socket,ofc cable slicing with accessaories...

Karnataka State Electronics Development Corporation Limited - Karnataka

35944746 supply & installation of ip based cctv system , lt electrical works pvc conduits & its accessories a ) 25mm dia 2mm thick, lt electrical works pvc conduits & its accessories b ) 32mm dia 2.5mm thick, lt electrical works pvc conduits & its accessories c ) 40mm dia 2.5mm thick, 1 / 3 progressive scan cmos, 5.0 megapixel, ip based colour camera, poe switches 4 / 6 port giga switch, poe switches 8 port giga switch, poe switches ( 12 port ) , nvr ( networkable video recorder ) 32 channel nvr, up to 32ch ip cameras input with all necessary accessories, nvr ( networkable video recorder ) 16 channel nvr, up to 16ch ip cameras input, up to with all necessary accessories., i3 cpu with 4gb ram + 8gb hard disk with key board & mouse, camera braclets with back box, media converter single port with of c sfp, media converter outdoor box pole mount or wall mount, wall mount 6u rack, electrical mcb with panel, cable ( cat6 data cable utp armounted ofc cable ) , cable ( cat 6 data cable utp amounted ) , cable ( cat6 data cable utp shleided ) , gi metal poles 12 to 15 feet with nut boit system aling with earthing material, rj45 connectors with pvc cap, female cat 6 io connectors, gi wire 8 guage for earthing, 4k led 65 inch tv display ( uv make ) , 2.5sqmm 3 core armoured power cable, ofc termination outdoor encloser box, 2 module with switch and 3 pin socket, ofc cable slicing with accessaories...

Airports Authority Of India - Karnataka

35926312 tender for miscellaneous electrical works at gagan and hal airport fabrication, supply, installation, testing and commissioning of auto mains failure control / logic panel ( excluding switchgear / breakers ) with auto bypass facility suitable for 750kva cummins make dg set ( non synchronous mode ) fabricated out of powder coated sheet steel of 1.6 mm thickness, required auxillary relays / timers, interconnection / control wiring, termination of existing control cables ( from acb panel / dg set to amf panel ) etc with following components / items, system operation in auto / manual / test modes etc complete as per specifications and site requirements ( i ) digital / microprocessor based amf relay 01 no. ( ii ) battery charger complete with transformer / rectifier, dc voltmeter and ammeter, selector switch, trickle, off & boostand current adjustment facility. 01 set ( iii ) audio / visual annuciation for high water temperature, low lubricating oil pressure, engine over speed, engine fails to start, full load / maximum load warning and other required engine shut down and alternator protections 01 set ( iv ) energy analyser unit to indicate current, phase and line voltages, frequency, power factor, kwh and kvarh 01 set ( v ) necessary indication lamps, fuses, terminal blocks, push buttons, control switches etc. as required. 2 supply, installation, testing and commissioning of 30v, dc auxilary relay ( vaa33 or equivalent ) for transformer winding temperature & oil temperature protections on the existing ht vcb panel including making necessary cut outs, interconnection wiring, required control wiring and termination of existing control cable ( from transformer to ht panel ) etc. complete as required as per site requirements. 3 supply, installation, testing and commissioning of digital / microprocessor based overcurrent and earthfault relay ( mc61a or equivalent ) on the existing ht vcb panel including dismantling of existing idmt electromechanical relay and installation of new relay with all the accessories and making required interconnection, control wiring etc. complete as required as per site requirements 4 supply & laying of 63mm dia ( od ) hdpe pipe of pn 6, pe 80 grade along with all accessories like socket, bend couplers etc. conforming to is: 4984 complete with fitting, cutting, jointing etc.direct in ground ( 75 cm below ground level ) including excavation and refilling the trench but excluding sand cushioning, protective covering etc. completeas required. 5 supply & laying of 63mm dia ( od ) hdpe pipe of pn 6, pe 80 grade along with all accessories like socket, bend couplers etc. conforming to is: 4984 complete with fitting, cutting, jointing etc.under bitumenous / concrete surface ( 75 cm below ground level ) including dismantling / cutting the concrete surface / bitumen surface, excavation and refilling the trench, finishing the top surface with cement concrete 1:3:6 but excluding sand cushioning, protective covering etc. completeas required. 6 ssupply of 3.5c x 50 sq.mm, xlpe insulated, pvc sheathed, aluminium conductor armoured cable of 1.1 kv grade conforming to is 7098 ( part 1 ) : 1988 with upto date amendments etc. as required. 7 laying of one number pvc insulated and pvc sheathed / xlpe power cable of 1.1 kv grade of following size in the existing rcc / hume / metal / hdpe pipe as required.above 35 sq. mm and upto 95 sq. mm 8 laying of one number pvc insulated and pvc sheathed / xlpe power cable of 1.1 kv grade of following size in the existing masonry open as required.above 35 sq. mm and upto 95 sq. mm 9 laying and fixing of one number pvc insulated and pvc sheathed / xlpe power cable of 1.1 kv grade of following size on wall surface as required.above 35 sq. mm and upto 95 sq. mm 10 supplying and making end termination with brass compression gland and aluminium lugs for 3.5c x 50 sq.mm pvc insulated and pvc sheathed / xlpe aluminium conductor cable of 1.1 kv grade as required. 11 providing and fixing 6 swg dia gi wire on surface or in recess for loop earthingas required. 12 supply of 4ft x 1ft recess mounted led luminaries having minimum 3600 lumen output complete with electronic driver, made out of powder coated crca / aluminium housing with opal / acrylic diffuser suitable to operate on 230v, 50hz single phase ac supply etc complete as per specifications. 13 supply of led flood lights having minimum 22000 lumen output complete with electronic driver, made out of aluminium die cast housing with secondary optics, , ip 65 or higher protection etc and suitable to operate on 230v, 50hz single phase ac supply etc, complete as per specifications. 14 supply of high performance led street light luminarie having minimum output of 6500 lumen with electronic driver, pressure die cast aluminum housing, secondary optics, toughened glass with ip 65 or higher protection etc. and suitable to operate on 230v, 50hz single phase ac supply etc complete as per specifications. 15 installation, testing and commissioning of led indoor recess type fittings on the existing false ceiling complete with hanging arrangements, making necessary connections with 1.5 sq.mm pvc insulated copper wire, required accessories like fasteners, screws, clamps etc. complete as required. 16 installation, testing and commissioning of led steet light / flood light fittings on existing bracket of street light pole / lantern carriage of high mastincluding making necessary connections with 1.5 sq.mmcopper wire, fixing with suitable clamp, nut / boltsetc. completeas required....

Karnataka Power Transmission Corporation Limited - Karnataka

35897413 combined package for strengthening of the existing earthing system by providing additional ci pipes & by replacing existing gi pipes by ci pipes & gi wires by gi flats at in kiadb mandya & mandya in mandya taluk, mandya dist on ptk basis....

Karnataka Power Transmission Corporation Limited - Karnataka

35890027 combined package for strengthening of the existing earthing system by providing additional ci pipes & by replacing existing gi pipes by ci pipes & gi wires by gi flats at in km doddi, kirugavalu & maddur in maddur taluk, mandya dist on ptk basis...

Indian Army - Karnataka

35882011 bids are invited for m seal , buffering soap , teflon tape viking , cpvc solutions , plumber white , fevi kwik , hss metal drill , hexagonal bit , cutting wheel , graphite pot , aluminium revet , hexagonal bolt , aluminium pop , metal paste , gi wire , gi revet , lathe bits , drill bits , carbide end mill , distilled water , electrolite , jack cable , eternity ge cord , eternity ge power , soldering rod , lid soldering , mobile lead , casing and capping , casing , bolt and nuts , all size washer , lapping abrassives , hack saw blade total quantity : 1816...

Indian Army - Karnataka

35825547 bids are invited for ptz camera ptz camera , 8 channel dvr , cat 6 cable , 4 tb ssd hdd , camera extension , signal booster , u rack box , 43 inch led display unit wall mounting stand , wire connectors , gi wire , 8 channel smps for ptz camera , casing pipe , 8 port poe switch , hdmi cable , splitters for camera total quantity : 1856...

Indian Army - Karnataka

35706668 bids are invited for trade training items m seal , buffering soap , teflon tape viking , cpvc solutions , plumber white , fevi kwik , hss metal drill , hexagonal bit , cutting wheel , graphite pot , aluminium revet , hexagonal bolt , aluminium pop , metal paste , gi wire , gi revet , lathe bits , drill bits , carbide end mill , distilled water , electrolite , jack cable , eternity ge cord , eternity ge power , soldering rod , lid soldering , mobile lead , casing and capping , casing , bolt and nuts , all size washer , lapping abrassives , hack saw blade total quantity : 1816...

Military Engineer Services - Karnataka

35416041 repair to roof sheet, steel painting, false ceiling and misc item in domestic area at afs yelahanka dismantling of plain or corrrugated steel sheeting, any gauge, thickness, including nainital or similar pattern roof coverings all as specified and directed. 2 dismantling timber scantlings unframed40 sq. cm and over in section, in any position, all as specified and directed. 3 s&f steel work in tubular trusses including special shaped washer etc complete or butt welded tubes conforming to is 1161 1979 graded st 240 all as specified and directed. 4 s&f pre painted galvalume aluminium zinc coating gi based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 mps as in roof covering / cladding to wall, fixed with self tapping screws all as specified and directed. 5 s&fpre painted galvalume aluminum zinc coating gi based plain steel sheet 0.50mm thick of any colour having tensile strength of 550 mpa as in roof covering / cladding to wall, fixed with self tapping screws as specified 6 dismantling of old ceiling boards ( fibre, pulp, insulation, etc ) or insulation boards / slabs blankets, including cover fillets and frame work. 7 s&f ofarmstrong board 12mm thick in ceiling fixed with screws all complete asper manufacturer’s instructions . 8 s&f anodized aluminium snap grid ofsize 605mmx605mm ( powder coated ) frame work for false ceiling, including 4mm dia gi wire for hanging all as specified in ssr and as directed by eng in charge. 9 dismantling floor, hearth or wall tiling including cement mortar bedding ( but not backing ) removing serviceable tiles to store and rubbish off the premises complete all as specified and directed. 10 m&l fornon skid coloured ceramic tiles 7 to 8 mm thickarea of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm, in floors etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match with tile incl screedd bed 15 mm thick in cm ( 1:6 ) complete all as directedand specified. 11 m & l for machine cut kota stone slab flooring 20 25mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing & complete 15mm thick screed bed in cm 1:4 , all as spd & directed. 12 m&l vitrified tiles of light shade 10mm thick and area of each tiles not exceeding 0.36 sqm for flooring over 15 mm thick screed bedin cm 1:6all as specified and directed. 13 m&l non skid coloured ceramic tiles 7 to 8 mm thick and area of each tiles not exceeding 0.18 sqmas inflooring over 15mm thick screed bed in cm 1:6all as specified and directed. 14 m&l glazed coloued ceramictiles of size 450x350x7mm thick set and jointed in neat cement slurry and pointed in white or colour cement to matchas in skirting / dadoover 10 mm thick plaster in cm 1:4 finished all as specified and directed . 15 s&f glazed coloured ceramic tiles 300x200x 6 to 7mm thick as in vertical surface such as skirting, dado, etc set and jointed in neat cement slurry and pointed in coloured cement to match the shade of tiles incl 10mm thick plastering in cm 1:3 complete all as specified 16 m&l for granite ( of any type ) tiles 20mm thick machine cut, bedded and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone including cutting, rounding of edges, grinding and polishing complete over 20mm thick screed bed in cm 1:6 all as specified and directed. 17 demolition of cement concrete in ground floor and pavings nexc 15cm thickness ( below or above ground level ) . 18 m&l for repairing of 40mm thick flooring in patches with pcc ( 1:2:4 ) 20mm graded stone agg. & finished even & smooth w / o using extra cement complete all as specified and directed by engr in charge. 19 m&l75 mm thick pcc 1:3:6 type c2 as in plinth protection and paving finishing surface even and smooth without using extra cement 20 demolition of brick work or stone masonry built in cm incl all quions all as specified 21 taking down cement plaster from wallsof any description all as specified and directed. 22 m&l for brick work with sub class b bricks , straight or curved on plan exc. 6 m mean radius built in cm 1:6 complete all as specified and directed. 23 m / l 15 mm thick cement plaster in cm ( 1:6 ) including finished even and smooth ( without using extra lime or cement ) . 24 m&l 10mm thick cement plaster in cm 1:6 on brick work or concrete surfaces rendering is to be even & smooth without using extra cement on internal walls complete all as specified and directed. 25 m&l for applying two coats of distemper ( obd ) including preparation to the new surfaces of wall, all as specified and as directed 26 preparation of newly plastered surfaces and applying two coats of cement base paint on walls incl priming surfaces with alkali resistant priming paintetc complete all as specified and directed. 27 m&l for complete removal of existing wall surface finish and applyingtwo coat of oil bound distember all as specified and directed. 28 m&l for preparation of existing wall surface finish and applyingone coat of oil bound distember all as specified and directed. 29 m&l for complete removal of existing surface finish and applying 1 2 mm thickwall careputty at wall and ceiling surfacesall as specified and directed. 30 m&l preparationof surface and applyingtwo coat of white wash on oldwall surface all as specified and directed. 31 m&l preparing old painted wooden surface and applying one coat of synthetic enamel paintall as specified and directed. 32 m&l preparing old painted steel surface and applying one coat of synthetic enamel paintall as specified and directed. 33 m&l for onecoat of exterior paint to old decoratedsurfacesof wallincl preparation of surfaces complete all as specified and directed. 34 taking down door chowkats or frames not exceeding 1.5 sqm with shutters ( without taking off shutters from the frame ) of any description 35 all as per item no 34 above but exceeding 1.5 sqm but not exceeding 4 sqm 36 taking down shuttes of any description exc 1 sqm and n.exc 2 sqm, all as specified and directed. 37 taking down shuttes of any description and refixing in the same opening after necessary easing and cutting all as specified and directed. 38 m&l cutting holes in brick / stone walls built in cm for inserting hold fast and making good dismantled portion in cm 1:3 or pcc 1:2:4 ( type b 0 ) ( using 12.5 mm graded aggregate ) ¸depth of embedded portion of hold fast not exceeding half brick 39 s&f solid pvc door frame of size 50mm x 47mm made out of 5mm plain colour pvc sheet reinforced with m.s. square tube, suppling & fixing in single side prelam pvc sheetused instead of plain colour pvc sheet & edges will be painted to match with prelam sheet all as specified and directed. 40 s&f factory made solid pvc moulded door shutter, with particle board core 28 to 30 mm thick ( stiles ) , with 2, 4, or 6 raised panel design with 2mm thick moulded prelam pvc sheet on the front face & 2mm plain colour pvc sheet on back face including neccessary fitiings etc complete as specified and directed. 41 s & f ii nd class hard wood plain, solid, straight chowkats and frames, wrought, framed rebated on the solid, rounded or chamfered, put together with glue pinned at joints, supplied and fixed all as specified and directed. 42 s&f continuous ( piano ) hinges, mild steel, bright finish of electrogalvanised 30 mm width of flap. 43 m&l prelaminated particle board, 19 mm thick interior grade, prelaminated one side with decorative choice lamination & otherside balancing white lamination, fixed with screws to timber frame work as in repairs. 44 m&l 12mm thick block boards grade 2 quality, interior grade decorative type with decovative face veneer on one face, fixed with screws to timber frame work all as specified and as directed fixed in repairs 45 m&l cover fillets of standard 4.5 mm thick ness hard board, 40mm wide, and fixing with screws. 46 s&f 300 mm ordinary rat rail rod pattern springs incl roller and roller plate complete. 47 s&f for 35mm thick flush shutters, solid core construction, with block board core and plywood face panels, commercial type on both sides all as specified and directed. 48 s&f 35mm thick 2 nd class hard wood glazed and skelton shutters, open rebated and prepared to receive glass, gauze etc divided into squares, with plain, chamfered or rounded, mitred and rebated sash bars, any numbers.edges of framing plain, chamfered or rounded, fitted with cut and mitered beads for securing glass etc, sizes of members of shutters as specified in ssr part i, section 8, clause 8.24 and fitted to chowkats. 49 m&l preparing new or previously untreated wooden surfaces of any description over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer. 50 s&f butt hinges of size 100mm extruded aluminium alloy with galvanised mild steel hinge pin, anodised and fixed, type c 21 all as specified and directed. 51 s&f aluminium alloy anodised, sliding door bolt 250 mm long with hasp, staple ( bolt type ) and fixing clips of sheets , cast or extracted section and fixing bolt and sliding bolts of extracted section. 52 s&f for aluminium anodised, barrel tower bolt 150mm of extruded section. 53 s&f for aluminium handle 150mm cast type anodised. 54 s&f floor door stopper of aluminium alloy body and tongue, anodised with hard drawn steel spring fixed in floor 150 mm size of cover plate. 55 hacking out old broken glass ( any thickness, size, quality ordescription ) from wooden frames or stone concrete glazed with oil putty or fixed with beeds. 56 s&f sheet glass ordinary quality 4mm thick and glazing with oil putty in square n.exc 0.50 sqm in each pane all as directed by engineer in charge 57 all as item 56 above but figured glass pin head type. 58 s&f sheet glass ordinary quality 4.8mm thick as in window, showcase alum frame work & similar work with or without glass roller area exc 0.50 sqm including neoprime gasketall as directed by engineer in charge 59 s & f stainless steel wire cloth 0.36 mm nominal dia of wire and average width or aperture 1.40 mm all as specified and directed. 60 s & f in repairs stainless steel wire cloth 0.36 mm nominal dia of wire and average width or aperture 1.40 mm all as specified and directed. 61 s & f framed work as grills conforming to fe 290 gde e 165 62 m&l preparing new steel surfaces of any description and applying two coat of synthetic enamel paint over one coat of red oxide zinc chrome to steel surface all as specified and directed. 63 s&f in repairsdecorative wooden finished curtain rod mild steel chromium plated of 20 mmdia all as directed and specified by engr in charge. 64 s&f decorativewooden finished type chromium plated double brackets supports for holding curtain rods and corners to be fixed to ends of curtain with screws complete. 65 taking up or down 15mm steel tubing and connections all as specified and directed. 66 taking up or down 20mm steel tubing and connections all as specified and directed. 67 s&f 20 mm dia of cpvc pipes sdr 11 fittings on walls / ceiling or laying in floors complete all as specified. 68 s&f cpvc pipes25 mm sdr 11 & plain cpvc sdr 11 on walls, ceiling or laying in floor including fitting in floors all as specified and as directed by engr in charge. 69 s&f in repairs vitreous china wash down water closet pan ( pedestal pattern ) , white premium quality ( excluding fixing bolts, flushing cistern and flush pipe ) all as specified and directed.make: cera / parryware / neycer / jaquar 70 s&f plastic pedestal pattern seat cover with flat bottom and cover and ms chormium plated hanging type device all as specified and directed.make : cera / parryware / neycer / jaquar 71 s&f in repairs vitreous china squatting pan orrisa pattern white colour of size 580x440mm with integral foot rests including ptrap andprovision of cement concrete for good making surfacecomplete all as specified & directed by engr in charge.makle:cera / parryware / neycer / jaquar 72 supply and fixing in repairs 10 litrecapacity pvc syphonic action type for low level flushing cistern including all fittings and including flushing pipe fixed in repair all as specified and as directed.make : cera / parryware / neycer / jaquar 73 supply and fixingin repairs vitreous china wash basin, white or coloured of size 550 x 400 mmwith padestal including bracketsall as specified and as directed.make : cera / parryware / neycer / jaquar 74 s&f in repairs for vitreous china under counter sunk modularwash basin white flat back size 190x550x430mm includingfixingof 32mm low density polylethyne pipes ( ldpe ) of pressure rating 6kg / cm2, coupling, directeded by engr in charge.make: cera / parryware / neycer / jaquar 75 s&f vitreous chinaurinals, bowl type of size 465x355x265mm white ( minimum ) with grating and union for discharge pipe ( excluding flushing cistern and waste pipe ) , complete including poviding and fixing plugs, bedding urinal against wall in cement mortar 1:2 securing urinal to plugs with and including 60mm long brass screws, pointing around urinal back in cement, fixingwith brackets, and union for discharge pipe fixed in repair, complete all as specified.make: cera / parryware / neycer / jaquar 76 s&f in repair pillar tap 15mm bore fancy type chromium plated, with capstan head screwed down high pressure with or without lettered “hot or cold” completed all as specified.make : cera / parryware / neycer 77 s&f in repair bib taps chromium plated 15 mm with fancy type with capstan head handle screwed both ends for iron pipe or for union complete all as specified.make : cera / jaguar / ess ess. 78 s&f in repair bib tap of ptmt any colour 15mm dia complete all as specified.make: prayag / polytuf or equivalent make as approved by ge 79 s&f in repairs stop valve 15mm dia, concealed type chromium plate fancy type with long shank and cup complete all as specified and directed.make : cera / jaguar / ess ess. 80 s&f sink cock in repairs fancy type complete all as specified and ( table mounted ) with 215 mm swivel spout complete all as specified and as directed.make: cera f2003302 or equivalent make in jaguar / marc 81 s&fin repair 15 mm dia two waybib taps ( fancy type ) , cast copper alloy withwith crutch or butter fly handle screwed down, screwed for iron pipe or forbrass ferrule complete with check nut 15mm bore complete all as specified and directed by engr in charge. make: cera model f2002161 or equivalent make in jaguar / marc 82 s&f in repairs 15mm dia angle valves, cast copper alloy, cp, screwed down, high pre ssure, with crutch, screwed both ends for iron pipe or for unions and fixed make: cera / jaguar / marc / sieco 83 s&f 600x450mm bevelled edge mirror of selected quality glass, mounted on 6mm thick ac building board or commercial plywood and fixed to wooden plugs with chromium plated brass screws and cup washers.make : modiguard / atul / govind 84 s&f pvc bathroom cabinet mirror of size 500x400mm all as specified and directed.make: prayag cat no 556 or equivalent make as approved by ge. 85 supply and fixing in repairs pvc connection 15mm size with ptmt nut of length 600mm etc complete all as specified and as directed.make: prayag / polytuf or equivalent make as approved by ge 86 supply and fixing of32mm waste pipe for wash hand basinall as specified and as directed 87 s& f in repairs brass chromium plated shower rose 125mm with swivel joints including fixing to steel pipe or union of 15mm bore all as specified and directed at site.make : cera / jaguar / ess ess. 88 s & f in repairs cpshower arm 15 mm size, 195 mm long with bend of 45 degree with flangeas specified and as directed.make : cera / jaguar / ess ess. 89 s&f cp towel rail 600 mm long fixed with chromium plated brass screws and wooden / plastic cleats fixed in repairs.make : cera / jaguar / ess ess 90 s&f in repairs of cp health faucet complete including neccessary holding arrangements with screws etc all as specified and directed by the engineer in charge.make: cera f 8030103 or equivalent make in jaguar / marc 91 s&f in repairscorner glass shelf assembly including neccessary holding arrangements with screws etc all as specified and directed by the engineer in charge.make: cera model f 5005102 or equivalent make in jaguar / parryware 92 s&f pvc floor trap 110mm dia, with grating including jointing to waste pipe fixed in cement concrete type b1 ( 1:2:4 ) 93 s&f pvc ( swr ) floor trap 75mm dia, with grating including jointing to waste pipe fixed in solvent cement 94 demolition and breaking up drain pipes ( salt glazed ware , ac, pvc or reinforced conc ) set in cement mortar of internal dia 75 110mm incl any earth work and demolition of pcc, complete all as specified. 95 s&f in repairspvc ( swr ) pipes 110mm dia single soketed, in any length with rubber ring joints, laid in trenches or in floors 96 s&f in repairspvc ( swr ) pipes 110mm dia single soketed, in any length with rubber ring joints, fixed to wall 97 s&f in repairs pvc ( swr ) pipes 75 mmsingle socketed, inanylength with rubber ring joints, laid in trenches or in floors. 98 s & f pvc ( swr ) bends 75 mm dia in any radius with access etc. 99 s & f pvc ( swr ) bends 110 mm dia in any radius with access etc. 100 s & f pvc ( swr ) branch piece single 110mm dia ( single y ) equal or unequal with access door including creating necessary provn in the existing pvc waste inlcuding jointing with rubber washer and solvent clamps etc. 101 s&f in repairsrotational moulded polyethylene water storage tank ( cylindricalvertical with closed top ) hoisted and jointed in position all as specified in ssr part i ( 1000 ltr capacity ) including disconnecting existing tank and providing all necessary fittings for connecting with pipe line, threadedtype cover complete all as specified and directed by engr in charge. make: sintex / polycon / kaveri 102 s&f in repairsrotational moulded polyethylene water storage tank ( cylindricalvertical with closed top ) hoisted and jointed in position all as specified in ssr part i ( 500 ltr capacity ) including disconnecting existing tank and providing all necessary fittings for connecting with pipe line, threadedtype cover complete all as specified and directed by engr in charge. make: sintex / polycon / kaveri 103 s&f in repair ball brass valve 25 mm dia high pressure, with polythene float and flynut complete all as specified and as directed.make: leader / zololo / prayaq 104 s&f in repairs cp grating size 100mm all as specified and directed. 105 s&f in repairs kitchen sinks with drainage board made ofstainless steel 1 mm thick with plugs, washers and wastes, including bedding in cementmortar to wallwith all fixing arrangements of overall size 915x460mm and bowl size 410x330x160mm all as specified and directed. make : nirali / diamond / blue star...

South Western Railway - Karnataka

35370480 supply of gi wire 8 swg coated with zinc confirming to grade zn 98 specified in is 209.1966. the zinc coating shall be uniform, adherent, reasonable smooth and free from imperfections as per is 280.2006, [ warranty period: 30 months after the date of delivery ] => limited...

Bharat Electronics Limited - Karnataka

35289616 supply installation testing and commissioning of vrv vrf ac odu 6hp vrv vrf cassette ac idu 2 tr and 2tr hw inverter type with 410a gas at adsn building supply installation testing and commissioning of vrv vrf ac odu 6hp vrv vrf cassette ac idu 2 tr and 2tr hw inverter type with 410a gas at adsn building , supply of variable refrigerant volume ( vrv ) / variable refrigerant flow ( vrf ) type air conditioning systems outdoor unit of capacity not less than 6 hp, equiped with highly efficient hermetic scroll compressor or twin rotary type compressors, equipped with inverter control capable of changing the speed in accordance to the cooling load requirement, heat exchanger, low noise condenser fan, outdoor unit multiple connecting unit, including first charge of r410a refrigerant & oil, etc. the inverter shall be igbt type to be efficient and quiet operation. the outdoor unit shall have the multi step of capacity control to meet load fluctuation. the quoted price shall include ms angle base frame structure duly black painted with synthetic epoxy paint for all outdoor units. the frame structure shall be mounted on ms plate & serrated rubber pads all as specified and / or directed etc., complete. note: the quotedrate for this item deemed to include the cost for necessary hardware, software, gateway, interface, controller etc. , supply of variable refrigerant volume ( vrv ) / variable refrigerant flow ( vrf ) type air conditioning systems indoor unit of cassette acof capacity not less than 2.0tr ( 7.0 kw ) with cordless remote for individual unit, cooling coil, expansion valve, multi speed fan, motor, power wiring from nearest power socket to indoor unit etc. the blower shall be dynamically balanced and designed for silent operation, the drain pan shall be fabricated out of heavy sheet steel with insulation, ms brackets / supports, all as specified and / or directed etc., complete. , supply of inverter type hi wall split ac with 2.0tr capacity with r410a / r32 refrigerant gas, wireless remote controller, cooling thermostat, required length of power cable and control cable between indoor and outdoor units, earthing, supports etc. complete , installation, testing and commissioning of variable refrigerant volume ( vrv ) / variable refrigerant flow ( vrf ) type air conditioning systems outdoor unit of capacity not less than 6 hp, equiped with highly efficient hermetic scroll compressor or twin rotary type compressors, equipped with inverter control capable of changing the speed in accordance to the cooling load requirement, heat exchanger, low noise condenser fan, outdoor unit multiple connecting unit, including first charge of r410a refrigerant & oil, etc. the inverter shall be igbt type to be efficient and quiet operation. the outdoor unit shall have the multi step of capacity control to meet load fluctuation. the quoted price shall include ms angle base frame structure duly black painted with synthetic epoxy paint for all outdoor units. the frame structure shall be mounted on ms plate & serrated rubber pads all as specified and / or directed etc., complete. , installation, testing and commissioning of variable refrigerant volume ( vrv ) / variable refrigerant flow ( vrf ) type air conditioning systems indoor unit of cassette acof capacity not less than 2.0tr ( 7.0 kw ) with cordless remote for individual unit, cooling coil, expansion valve, multi speed fan, motor, power wiring from nearest power socket to indoor unit etc. the blower shall be dynamically balanced and designed for silent operation, the drain pan shall be fabricated out of heavy sheet steel with insulation, ms brackets / supports, all as specified and / or directed etc., complete. , supply of size 22.2 mm dia refrigerant grade copper piping of 20 gauge including nitrile rubber tubular insulation, adhesive tape, including all kinds of valves / joints viz., refnet joint / header, refrigerant joint / header, distribution / branch unit, tees, valves, ball valves, fittings like bends, elbow, collars, tees, reducers, flanges, supports, etc for interconnecting the liquid and suction lines between theoutdoor units and the indoor units and flare connection to indoor units. refrigerant joints supplied by oem only shall be used. the piping shall be carried out of soft / hard drawn copper pipes brazed socket fittings. both the suction and liquid lines shall be insulated with closed cell nitrile rubber tubular insulation with factory laminated glass cloth and uv paniting of thickness as specified in tender including pressure testing and charging of refrigerant and oil. refrigerant piping and cables in wall crossings shall be provided in suitable steel / pvc sleeve all as specified and / or directed etc., complete. note: 1 ) only the cable tray supports provided for exposed refrigerant pipes will be measured and paid under the relevant item of soqr. , erection and testing and commissioning of size 22.2 mm dia refrigerant grade copper piping of 20 gauge including nitrile rubber tubular insulation, adhesive tape, including all kinds of valves / joints viz., refnet joint / header, refrigerant joint / header, distribution / branch unit, tees, valves, ball valves, fittings like bends, elbow, collars, tees, reducers, flanges, supports, etc for interconnecting the liquid and suction lines between theoutdoor units and the indoor units and flare connection to indoor units. refrigerant joints supplied by oem only shall be used. the piping shall be carried out of soft / hard drawn copper pipes brazed socket fittings. both the suction and liquid lines shall be insulated with closed cell nitrile rubber tubular insulation with factory laminated glass cloth and uv paniting of thickness as specified in tender including pressure testing and charging of refrigerant and oil. refrigerant piping and cables in wall crossings shall be provided in suitable steel / pvc sleeve all as specified and / or directed etc., complete. note: 1 ) only the cable tray supports provided for exposed refrigerant pipes will be measured and paid under the relevant item of soqr. , supply of size 19.1 mm dia refrigerant grade copper piping of 20 gauge including nitrile rubber tubular insulation, adhesive tape, including all kinds of valves / joints viz., refnet joint / header, refrigerant joint / header, distribution / branch unit, tees, valves, ball valves, fittings like bends, elbow, collars, tees, reducers, flanges, supports, etc for interconnecting the liquid and suction lines between theoutdoor units and the indoor units and flare connection to indoor units. refrigerant joints supplied by oem only shall be used. the piping shall be carried out of soft / hard drawn copper pipes brazed socket fittings. both the suction and liquid lines shall be insulated with closed cell nitrile rubber tubular insulation with factory laminated glass cloth and uv paniting of thickness as specified in tender including pressure testing and charging of refrigerant and oil. refrigerant piping and cables in wall crossings shall be provided in suitable steel / pvc sleeve all as specified and / or directed etc., complete. note: 1 ) only the cable tray supports provided for exposed refrigerant pipes will be measured and paid under the relevant item of soqr. , erection andtesting and commissioning of size 19.1 mm dia refrigerant grade copper piping of 20 gauge including nitrile rubber tubular insulation, adhesive tape, including all kinds of valves / joints viz., refnet joint / header, refrigerant joint / header, distribution / branch unit, tees, valves, ball valves, fittings like bends, elbow, collars, tees, reducers, flanges, supports, etc for interconnecting the liquid and suction lines between theoutdoor units and the indoor units and flare connection to indoor units. refrigerant joints supplied by oem only shall be used. the piping shall be carried out of soft / hard drawn copper pipes brazed socket fittings. both the suction and liquid lines shall be insulated with closed cell nitrile rubber tubular insulation with factory laminated glass cloth and uv paniting of thickness as specified in tender including pressure testing and charging of refrigerant and oil. refrigerant piping and cables in wall crossings shall be provided in suitable steel / pvc sleeve all as specified and / or directed etc., complete. note: 1 ) only the cable tray supports provided for exposed refrigerant pipes will be measured and paid under the relevant item of soqr. , supply of size 15.9 mm dia refrigerant grade copper piping of 20 gauge including nitrile rubber tubular insulation, adhesive tape, including all kinds of valves / joints viz., refnet joint / header, refrigerant joint / header, distribution / branch unit, tees, valves, ball valves, fittings like bends, elbow, collars, tees, reducers, flanges, supports, etc for interconnecting the liquid and suction lines between theoutdoor units and the indoor units and flare connection to indoor units. refrigerant joints supplied by oem only shall be used. the piping shall be carried out of soft / hard drawn copper pipes brazed socket fittings. both the suction and liquid lines shall be insulated with closed cell nitrile rubber tubular insulation with factory laminated glass cloth and uv paniting of thickness as specified in tender including pressure testing and charging of refrigerant and oil. refrigerant piping and cables in wall crossings shall be provided in suitable steel / pvc sleeve all as specified and / or directed etc., complete. note: 1 ) only the cable tray supports provided for exposed refrigerant pipes will be measured and paid under the relevant item of soqr. , erection and testing and commissioning of size 15.9 mm dia refrigerant grade copper piping of 20 gauge including nitrile rubber tubular insulation, adhesive tape, including all kinds of valves / joints viz., refnet joint / header, refrigerant joint / header, distribution / branch unit, tees, valves, ball valves, fittings like bends, elbow, collars, tees, reducers, flanges, supports, etc for interconnecting the liquid and suction lines between theoutdoor units and the indoor units and flare connection to indoor units. refrigerant joints supplied by oem only shall be used. the piping shall be carried out of soft / hard drawn copper pipes brazed socket fittings. both the suction and liquid lines shall be insulated with closed cell nitrile rubber tubular insulation with factory laminated glass cloth and uv paniting of thickness as specified in tender including pressure testing and charging of refrigerant and oil. refrigerant piping and cables in wall crossings shall be provided in suitable steel / pvc sleeve all as specified and / or directed etc., complete. note: 1 ) only the cable tray supports provided for exposed refrigerant pipes will be measured and paid under the relevant item of soqr. , supply of size 12.7 mm dia refrigerant grade copper piping of 20 gauge including nitrile rubber tubular insulation, adhesive tape, including all kinds of valves / joints viz., refnet joint / header, refrigerant joint / header, distribution / branch unit, tees, valves, ball valves, fittings like bends, elbow, collars, tees, reducers, flanges, supports, etc for interconnecting the liquid and suction lines between theoutdoor units and the indoor units and flare connection to indoor units. refrigerant joints supplied by oem only shall be used. the piping shall be carried out of soft / hard drawn copper pipes brazed socket fittings. both the suction and liquid lines shall be insulated with closed cell nitrile rubber tubular insulation with factory laminated glass cloth and uv paniting of thickness as specified in tender including pressure testing and charging of refrigerant and oil. refrigerant piping and cables in wall crossings shall be provided in suitable steel / pvc sleeve all as specified and / or directed etc., complete. note: 1 ) only the cable tray supports provided for exposed refrigerant pipes will be measured and paid under the relevant item of soqr. , erection and testing and commissioning of size 12.7 mm dia refrigerant grade copper piping of 20 gauge including nitrile rubber tubular insulation, adhesive tape, including all kinds of valves / joints viz., refnet joint / header, refrigerant joint / header, distribution / branch unit, tees, valves, ball valves, fittings like bends, elbow, collars, tees, reducers, flanges, supports, etc for interconnecting the liquid and suction lines between theoutdoor units and the indoor units and flare connection to indoor units. refrigerant joints supplied by oem only shall be used. the piping shall be carried out of soft / hard drawn copper pipes brazed socket fittings. both the suction and liquid lines shall be insulated with closed cell nitrile rubber tubular insulation with factory laminated glass cloth and uv paniting of thickness as specified in tender including pressure testing and charging of refrigerant and oil. refrigerant piping and cables in wall crossings shall be provided in suitable steel / pvc sleeve all as specified and / or directed etc., complete. note: 1 ) only the cable tray supports provided for exposed refrigerant pipes will be measured and paid under the relevant item of soqr. , supply of size 9.5 mm dia refrigerant grade copper piping of 20 gauge including nitrile rubber tubular insulation, adhesive tape, including all kinds of valves / joints viz., refnet joint / header, refrigerant joint / header, distribution / branch unit, tees, valves, ball valves, fittings like bends, elbow, collars, tees, reducers, flanges, supports, etc for interconnecting the liquid and suction lines between theoutdoor units and the indoor units and flare connection to indoor units. refrigerant joints supplied by oem only shall be used. the piping shall be carried out of soft / hard drawn copper pipes brazed socket fittings. both the suction and liquid lines shall be insulated with closed cell nitrile rubber tubular insulation with factory laminated glass cloth and uv paniting of thickness as specified in tender including pressure testing and charging of refrigerant and oil. refrigerant piping and cables in wall crossings shall be provided in suitable steel / pvc sleeve all as specified and / or directed etc., complete. note: 1 ) only the cable tray supports provided for exposed refrigerant pipes will be measured and paid under the relevant item of soqr. , erection and testing and commissioning of size 9.5 mm dia refrigerant grade copper piping of 20 gauge including nitrile rubber tubular insulation, adhesive tape, including all kinds of valves / joints viz., refnet joint / header, refrigerant joint / header, distribution / branch unit, tees, valves, ball valves, fittings like bends, elbow, collars, tees, reducers, flanges, supports, etc for interconnecting the liquid and suction lines between theoutdoor units and the indoor units and flare connection to indoor units. refrigerant joints supplied by oem only shall be used. the piping shall be carried out of soft / hard drawn copper pipes brazed socket fittings. both the suction and liquid lines shall be insulated with closed cell nitrile rubber tubular insulation with factory laminated glass cloth and uv paniting of thickness as specified in tender including pressure testing and charging of refrigerant and oil. refrigerant piping and cables in wall crossings shall be provided in suitable steel / pvc sleeve all as specified and / or directed etc., complete. note: 1 ) only the cable tray supports provided for exposed refrigerant pipes will be measured and paid under the relevant item of soqr. , supply of cpvc ( sdr11 ) pipes of 32 mm dia, schedule 40 with 9 mm thick elastomeric nitrile rubber tubular insulation with factorylaminated glass cloth and uv paniting for condensate water drain from the ac indoor units to nearest drain point, fittings, supportetc. complete , installation of cpvc ( sdr11 ) pipes of 32 mm dia, schedule 40 with 9 mm thick elastomeric nitrile rubber tubular insulation with factory laminated glass cloth and uv paniting for condensate water drain from the ac indoor units to nearest drain point, fittings, supportincluding core cutting in brick / concrete wall as required and making surface good etc. complete , supply of cpvc ( sdr11 ) pipes of 40 mm dia, schedule 40 with 9 mm thick elastomericnitrile rubber tubular insulation with factory laminated glass cloth and uv panitingfor condensate water drain from the ac indoor units to nearest drain point, fittings, supportetc. complete , installation of cpvc ( sdr11 ) pipes of 40 mm dia, schedule 40 with 9 mm thick elastomeric nitrile rubber tubular insulation with factory laminated glass cloth and uv paniting for condensate water drain from the ac indoor units to nearest drain point, fittings, supportincluding core cutting in brick / concrete wall as required and making surface good etc. complete , structural steel worksmade of channels, angles, plates, flats, pipes, cleats etc., including welding at shop or at work site including painting with two coats of synthetic enamel paint of approved make and shade, over a coat of approved steel primer etc., complete , supply and fixing of 6 pin 15 / 16 amps modular switch socket outlet, isi marked above false ceiling for indoor cassette ac units , wiring for power cirucit with 2x4 sq. mm frls pvc insulated copper conductor single core cable in surface / recessed steel conduit alongwith 1 no. 4 sq. mm frls pvc insulated copper conductor single core cable for loop earthing as required. , supplying and fixing of 20mm dia size steel conduit pipes along with accessories in surface / recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required. , supply of 4cx6 2xfy cppper cable, xlpe insulated, pvc sheathed, armoured, 1.1kv grade lt cable for vrv outdoor unit. , laying and end termination of 4cx6 2xfy cppper cable, xlpe insulated, pvc sheathed, armoured, 1.1kv grade lt cable. , supply of 150 mm width x 50 mm depth x 1.6 mm thickness of perforated hot dipped galvanised iron cable tray ( galvanisation thickness not less than 50 microns ) with perforation not more than 17.5%. , fixing of 150 mm width x 50 mm depth x 1.6 mm thickness of perforated hot dipped galvanised iron cable tray ( galvanisation thickness not less than 50 microns ) suspended form ceiling or on wall including g.i. bolts & nuts, etc. along with bends, tee joints or necessary accessories as required. , supply and bonding of 6 swg gi wire for earthing and bonding with the exisiting earthing system , supply and fixing of 32a tpn+e outdoor rated ( min.ip 65 ) industrial plug socket with mcb control. , supply and installation of mcb enclosure box consisting of 32a tpn mcb controlled by 24hr timer contactor with time setting functionality for auto on / off of the vrv unit. , installation, testing and commissioning of inverter type hi wall split ac with 2.0tr capacity with r410a / r32 refrigerant gas, wireless remote controller, cooling thermostat, required length of power cable and control cable between indoor and outdoor units, earthing, supports etc. complete , supply of refrigerant grade copper piping between indoorand outdoor units of suitable size ( both suction and discharge piping will be treated as one unit and will not be measured separately ) , suction line with insulation and discharge line without insulation including all fittings, accessories, core cutting in brick / concrete wall and making surface good, supports etc. for 2tr capacity hi wall ac unit , erection, testing and commissioning of refrigerant grade copper piping between indoorand outdoor units of suitable size ( both suction and discharge piping will be treated as one unit and will not be measured separately ) , suction line with insulation and discharge line without insulation including all fittings, accessories, core cutting in brick / concrete wall and making surface good, supports etc. for 2tr capacity hi wall ac unit , supply of cpvc ( sdr11 ) pipes of 25 mm dia with 9 mm thick elastomeric nitrile rubber tubular insulation with factory laminated with glass cloth and uv paniting for condensate water drain from the ac indoor units to nearest drain point, fittings, supportetc. complete , installation of cpvc ( sdr11 ) pipes of 25 mm dia with 9 mm thick elastomeric nitrile rubber tubular insulation factory laminated with glass cloth and uv paniting for condensate water drain from the ac indoor units to nearest drain point, fittings, supportincluding core cutting in brick / concrete wall as required and making surface good etc. complete , supply of pvc covering pipe of size 75mm suitable for exposed refrigerant pipes & cabling between the indoor and outdoor units forac units , erection, testing and commissioning of pvc covering pipe of size 75mm suitable for exposed refrigerant pipes & cabling between the indoor and outdoor units forac units , wiring for power circuit with 2x6 sq. mm frls pvc insulated copper conductor single core cable in surface / recessed steel conduit alongwith 1 no. 6 sq. mm frls pvc insulated copper conductor single core cable for loop earthing as required. , supplying and fixing of 20mm dia size steel conduit pipes along with accessories in surface / recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required. , supply and bonding of 6 swg gi wire for earthing and bonding with the exisiting earthing system , supply and fixing of 20a spnindoor rated ( min.ip 44 ) industrial plug socket with mcb control for hi wall split ac. , supply, fixing and installation of timer distribution board for changeover operation of acs for every 8 hours. db shall be able to control min. 04 nos. of hi wall split ac units. the timer db shall have provison for changeover time setting as per requirement....

Karnataka Power Corporation Limited - Karnataka

35176427 tender for consolidated procurement of cable jointing and wiring materials for all projects of kpcl , power cable vlo 0.75 sq mm, 07cx2.5 sqmm gland 1.1kv, 12c x 2.5 sq. mm gland, gland for 5cx2.5sqmm cable, 1000sqmm aluminium lug, power cable glant 1c 500sqmm, 5 amp socket, 5 amps switches, jumper cables, indoor 3x 400 sqmm 11kv termin, inst cbl cop 16px0.5 sqmm, cop inst arm cble 4cx.05m, cop inst arm cbl 12px.5mm, cop inst arm cbl 16cx.5mm, 8 swg gi wire, 8 swg gi wire, instru.cable 12pair x 0.5, heatshrink tube 2, heatshrink tube 1 / 16, heatshrink tube 1 / 8, heatshrink tube 1 / 4, heatshrink tube 3 / 8, heatshrink tube 1 / 2, heatshrink tube 1, heat shrink sleeve 2mm specification as per section iii tender document, solvent cement, xlpa 630sq.mm endtermnl kit id, 4c x 2.5sqmm copper mult cable, 4c x 2.5sqmm copper mult cable, m.strand copper wire 2.5sq.mm, multi strand copper wire 4.sq., 3cx1.5 sqmm cu.multi stand cab, 4cx2.5sqmm cu. multi stand cab, 2.5 sqmm multi std pvc cable, 2.5sqmm multi cable, 2.5sqmm multi cable, 2.5sqmm multi cable, calling bells, cable tie 150 mm, cable tie 200 mm, releasabl cable tie 300x7.6 mm, cable tie 300x7.6 mm, cable tie 600 x 9 mm, cable tie 200 x 4.8 mm, cable tie 150 x 4.6 mm, marker cable tie 100x2.5mm...

South Western Railway - Karnataka

35062799 supply of gi wire 8 swg coated with zincgi wire 8 swg coated with zinc,gi wire 8 swg coated with zinc confirming to grade zn 98 specified in is 209.1966. the zinc coating shall be uniform, adherent, reasonable smooth and free from imperfections as per is 280.2006, => limited...

South Western Railway - Karnataka

34981159 auction sale of [ pl no. 98090800 ] scrap / cond / released / rusted m.s bazar scrap such as disintegrated thorough rust corrugated sheets, pots, springs cutting hup iron, gurrah, mortar pans, buckets, oil tanks, coal tubes, un sound / corroded paint drums / tar / oil / grease barrels containing with / without paint / oil / tar, water strainer, bail putty, corroded commode chutes, name disply board, punjas, destination board, tins, sheets, packing sheets, corroded battery boxes / sheets / released u type sheets of different sizes and lengths, corroded dust shield springs, fencing wire, oil filters, packing bands, rusted gi wire knitting, iron mesh, corroded zinc sheet / fabricated materials, corroded grs boxes, gi / ms wire / rope , alphabetic location boards, fully corroded tl fan / tube fittings, panel boards, broken fire extinguishers, geyser bodies and other items coming under bazaar scrap on as is where is condition available under the custody of cdms 08 ward ap. ( pressing permitted ) ( loc: bin no. 0127 at scarp yard...

South Western Railway - Karnataka

34945476 supply of gi wire 8 swg coated with zincgi wire 8 swg coated with zinc, gi wire 8 swg coated with zinc confirming to grade zn 98 specified in is 209.1966. the zinc coating shall be uniform, adherent, reasonable smooth and free from imperfections as per is 280.2006, => limited...

Karnataka Power Corporation Limited - Karnataka

34668129 procurement of cables , 16c x 2.5 sqmm control cable16 c x 2.5 sqmm copper, 1.1 kv grade, armored cable as per is make: finolex / polycab / havells / ralicab / universal unit of measurement for supply one number = one meters, 3.3 kv festooning cable ( crd ) specification: industrial power cable, 3.3 kv grade flexible trailing cable as per technical specification, f30iu04330601, 3c x 35 ( power cores ) + 3c x 35 / 3 sqmm ( earth cores ) , 3.3 kv grade cable generally to is:9968 ( part 2 ) 2002. dia of the cable 183 mm 3 power cores: annealed, flexible, tinned copper conductor ( class 5 to is:8130 / 84 ) , conductor screened with black extruded semiconducting compound, epr ( type ie3 to is:6380 / 84 ) insulated, insulation screened with balck extruded semi conducting compound, core identified with open spiral of coloured p.c. tape having colours red, yellow and blue. 3 earth cores: annealed, flexible, tinned copper conductor, covered with black extruded semi conducting compound, cores identified with open spiral of coloured p.c. tape having colour green 3 power cores will be laid up with the earth cores placed at the outer interstices, binder taped, inner sheathed with black hofr nbr pvc, type se3 to is6380 / 84, proofed cotton tapped, composite braided with annealed tinned copper wires and nylon & black hd hofr pcp, type se4 to is:6380 / 84 sheathed with open braid of nylon / cotton cord reinforcement. make: nicco corporation ltd. / universal cables ltd. ( brand name unistar ) or equivalent reputed make, 4c x 1.5 sqmm screened cable4c x 1.5 sqmm screened copper cable multi stranded, copper conductor, extruded pvc type a insulated as per is 694 pair twisted ( 20 twists per meter ) , shielded with aluminium mylar, such shielded pairs laid up, collectively shielded with aluminium mylar, provided with 0.5sqmm tinned copper drain wire, extruded pvc ( st1 ) innder sheathed, al / gi wire, armoured, frls extruded pvc ( st1 ) outer sheathed 650v grade cable generally as per is 1554 part 1, each pair of twisted and shielded pair shall also be provided with 0.5sqmm tinned copper drain wire. iec 60156 part i & ii. unit of measurement for supply one number = one meters, 4 core screened cable4 core screened cable, t&f / ptfe 20 / 19 / 32, part no. 4901370 unit of measurement for supply one number = one meters...

Rural Development Panchayath Raj Engineering Department - Karnataka

34503078 tender for turuvekere taluk package no: tmk tvk 46 / 22 23 1 civil work: earth work excavation by manual means for drains, canals, waste weir, draft, approach channels, key trenches, foundation of bridges and such simillar works in all kinds of soils , as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m including cost of labour, tools & other appurtenaces required to complete the work. in all kinds of soils depth upto 1.5 m with all lead and lift, loading & unloading, hire charges of machinery and equipments, transportation charges cost and conveyance of all materials, labour charges and all other incidental charges etc., complete as per standard technical detailed specification and design and directions of the engineer incharge of the work ( 1 ) 46.93 ( 2 ) 46.93 ( 3 ) 46.93 ( 4 ) 46.93 ( 5 ) 46.93 ( 6 ) 46.93 ( 7 ) 46.93 cum 328.51 2 filling available excavated earth ( excluding rock ) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering with all lead and lift, loading & unloading, hire charges of machinery and equipments, transportation charges cost and conveyance of all materials, labour charges and all other incidental charges etc., complete as per standard technical detailed specification and design and directions of the engineer incharge of the work ( 1 ) 32.85 ( 2 ) 32.85 ( 3 ) 32.85 ( 4 ) 32.85 ( 5 ) 32.85 ( 6 ) 32.85 ( 7 ) 32.85 cum 229.95 3 providing and laying in position plain cement concrete for levelling course for all works in foundation. the granite / trap / basalt crushed graded coarse aggregates and fine aggregates as per relevant is codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. ( the cost of steel reinforcement & formwork shall be paid separately ) mix 1:4:8 ( m5 ) using 40 mm nominal size graded crushed coarse aggregates with all lead and lift, loading & unloading, hire charges of machinery and equipments, transportation charges cost and conveyance of all materials, labour charges and all other incidental charges etc., complete as per standard technical detailed specification and design and directions of the engineer incharge of the work ( 1 ) 11.67 ( 2 ) 11.67 ( 3 ) 11.67 ( 4 ) 11.67 ( 5 ) 11.67 ( 6 ) 11.67 ( 7 ) 11.67 cum 81.69 4 providing random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 ( 1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size ) upto plinth level with : cement mortar 1:6 ( 1 cement : 6 coarse sand ) with all lead and lift, loading & unloading, hire charges of machinery and equipments, transportation charges cost and conveyance of all materials, labour charges and all other incidental charges etc., complete as per standard technical detailed specification and design and directions of the engineer incharge of the work ( 1 ) 12.12 ( 2 ) 12.12 ( 3 ) 12.12 ( 4 ) 12.12 ( 5 ) 12.12 ( 6 ) 12.12 ( 7 ) 12.12 cum 84.84 5 providing coursed rubble masonry ( second sort ) with hard stone in foundation & plinth with cement mortar 1:6 ( 1 cement : 6 coarse sand ) with all lead and lift, loading & unloading, hire charges of machinery and equipments, transportation charges cost and conveyance of all materials, labour charges and all other incidental charges etc., complete as per standard technical detailed specification and design and directions of the engineer incharge of the work ( 1 ) 6.84 ( 2 ) 6.84 ( 3 ) 6.84 ( 4 ) 6.84 ( 5 ) 6.84 ( 6 ) 6.84 ( 7 ) 6.84 cum 47.88 6 appendix i – additionalities for formwork, centering 1. foundation upto plinth a ) isolated 8% with all lead and lift, loading & unloading, hire charges of machinery and equipments, transportation charges cost and conveyance of all materials, labour charges and all other incidental charges etc., complete as per standard technical detailed specification and design and directions of the engineer incharge of the work ( 1 ) 17.81 ( 2 ) 17.81 ( 3 ) 17.81 ( 4 ) 17.81 ( 5 ) 17.81 ( 6 ) 17.81 ( 7 ) 17.81 cum 124.67 7 providing and laying in position reinforced cement concrete for all foundation works. the granite / trap / basalt crushed graded coarse aggregates and fine aggregates as per relevant is codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant is codes , labour, usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. ( the cost of steel reinforcement & formwork to be paid separately ) m20 design mix using 20 mm nominal size graded crushed coarse with all lead and lift, loading & unloading, hire charges of machinery and equipments, transportation charges cost and conveyance of all materials, labour charges and all other incidental charges etc., complete as per standard technical detailed specification and design and directions of the engineer incharge of the work ( 1 ) 17.81 ( 2 ) 17.81 ( 3 ) 17.81 ( 4 ) 17.81 ( 5 ) 17.81 ( 6 ) 17.81 ( 7 ) 17.81 cum 124.67 8 appendix i – additionalities for formwork, centering 8. columns & piers 10%with all lead and lift, loading & unloading, hire charges of machinery and equipments, transportation charges cost and conveyance of all materials, labour charges and all other incidental charges etc., complete as per standard technical detailed specification and design and directions of the engineer incharge of the work ( 1 ) 4.17 ( 2 ) 4.17 ( 3 ) 4.17 ( 4 ) 4.17 ( 5 ) 4.17 ( 6 ) 4.17 ( 7 ) 4.17 cum 29.19 9 appendix i – additionalities for formwork, centering 12. beams & lintels of building 20% 13. roof ( straight & arched ) 20% with all lead and lift, loading & unloading, hire charges of machinery and equipments, transportation charges cost and conveyance of all materials, labour charges and all other incidental charges etc., complete as per standard technical detailed specification and design and directions of the engineer incharge of the work ( 1 ) 15.13 ( 2 ) 15.13 ( 3 ) 15.13 ( 4 ) 15.13 ( 5 ) 15.13 ( 6 ) 15.13 ( 7 ) 15.13 cum 105.91 10 providing thermo mechanically treated bars of grade fe 550d or more steel reinforcement for r.c.c. work including straightening, cutting, bending, placing in position, binding and anchoring to adjacent members whereever necessary complete as per design including cost of material, labour, usage charges complete as per specifications. ( the laps and wastages shall not be measured separately ) with all lead and lift, loading & unloading, hire charges of machinery and equipments, transportation charges cost and conveyance of all materials, labour charges and all other incidental charges etc., complete as per standard technical detailed specification and design and directions of the engineer incharge of the work ( 1 ) 2720.00 ( 2 ) 2720.00 ( 3 ) 2720.00 ( 4 ) 2720.00 ( 5 ) 2720.00 ( 6 ) 2720.00 ( 7 ) 2720.00 kg 19040 11 providing and laying in position reinforced cement concrete for all super structures of building , road works, water works, irrigation works & super structure works of bridges upto 3.50 m height. the granite / trap / basalt crushed graded coarse aggregates and fine aggregates as per relevant is codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. the cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant is codes , labour, usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. ( the cost of steel reinforcement, dowel bars & formwork to be paid separately ) m20 design mix using 20 mm nominal size graded crushed coarse aggregates with all lead and lift, loading & unloading, hire charges of machinery and equipments, transportation charges cost and conveyance of all materials, labour charges and all other incidental charges etc., complete as per standard technical detailed specification and design and directions of the engineer incharge of the work ( 1 ) 20.65 ( 2 ) 20.65 ( 3 ) 20.65 ( 4 ) 20.65 ( 5 ) 20.65 ( 6 ) 20.65 ( 7 ) 20.65 cum 144.55 12 ksrb 4.2.10 : providing and laying in position reinforced cement concrete of design mix m20 with opc cement @ 24kgs, with 2mm and down size graded granite metal coares aggregates @ 0.5175cum and fine aggregates @ 0.345cum, with superplastisiser @ 0.225lts, machine mixed, well compacted for plain chajja of 7.5cms average thickness, upto ground floor level including cost of all materials, labour, hom of machinery, curing, complete as per specifications. specification no. kbs 4.1, 4.6 with all lead and lift, loading & unloading, hire charges of machinery and equipments, transportation charges cost and conveyance of all materials, labour charges and all other incidental charges etc., complete as per standard technical detailed specification and design and directions of the engineer incharge of the work ( 1 ) 2.16 ( 2 ) 2.16 ( 3 ) 2.16 ( 4 ) 2.16 ( 5 ) 2.16 ( 6 ) 2.16 ( 7 ) 2.16 sqm 15.12 13 providing brick work with common burnt clay non modular bricks of class designation 3.5 in foundation and plinth in cement mortar 1:4 ( 1 cement : 4 coarse sand ) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work. with all lead and lift, loading & unloading, hire charges of machinery and equipments, transportation charges cost and conveyance of all materials, labour charges and all other incidental charges etc., complete as per standard technical detailed specification and design and directions of the engineer incharge of the work ( 1 ) 24.68 ( 2 ) 24.68 ( 3 ) 24.68 ( 4 ) 24.68 ( 5 ) 24.68 ( 6 ) 24.68 ( 7 ) 24.68 cum 172.76 14 providing 12 mm cement plaster with cement mortar 1:4 ( 1 cement: 4 fine sand ) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of engineer in charge. with all lead and lift, loading & unloading, hire charges of machinery and equipments, transportation charges cost and conveyance of all materials, labour charges and all other incidental charges etc., complete as per standard technical detailed specification and design and directions of the engineer incharge of the work ( 1 ) 44.46 ( 2 ) 44.46 ( 3 ) 44.46 ( 4 ) 44.46 ( 5 ) 44.46 ( 6 ) 44.46 ( 7 ) 44.46 sqm 311.22 15 providing 15 mm cement plaster on the rough side of single or half brick wall of mix 1:4 ( 1 cement: 4 fine sand ) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of engineer in charge. with all lead and lift, loading & unloading, hire charges of machinery and equipments, transportation charges cost and conveyance of all materials, labour charges and all other incidental charges etc., complete as per standard technical detailed specification and design and directions of the engineer incharge of the work ( 1 ) 58.28 ( 2 ) 58.28 ( 3 ) 58.28 ( 4 ) 58.28 ( 5 ) 58.28 ( 6 ) 58.28 ( 7 ) 58.28 sqm 407.96 16 providing 20 mm cement plaster of mix :1:4 ( 1 cement: 4 fine sand ) to brick / stone masonary including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of engineer in charge. with all lead and lift, loading & unloading, hire charges of machinery and equipments, transportation charges cost and conveyance of all materials, labour charges and all other incidental charges etc., complete as per standard technical detailed specification and design and directions of the engineer incharge of the work ( 1 ) 171.64 ( 2 ) 171.64 ( 3 ) 171.64 ( 4 ) 171.64 ( 5 ) 171.64 ( 6 ) 171.64 ( 7 ) 171.64 sqm 1201.48 17 flooring with 25mm thick polished tandur blue stone slabs using cement mortar 1:6, 25mm thick over existing cement concrete bed or top of roof laid to line and level and jointed with cement slurry mixed with pigment to match the shade of the slab, , including cost of materials, labour, curing, polishing complete as per specifications. with all lead and lift, loading & unloading, hire charges of machinery and equipments, transportation charges cost and conveyance of all materials, labour charges and all other incidental charges etc., complete as per standard technical detailed specification and design and directions of the engineer incharge of the work ( 1 ) 58.79 ( 2 ) 58.79 ( 3 ) 58.79 ( 4 ) 58.79 ( 5 ) 58.79 ( 6 ) 58.79 ( 7 ) 58.79 sqm 411.53 18 finishing walls with acrylic smooth exterior paint of required shade :new work ( two coat applied @ 1.67 ltr / 10 m� over and including priming coat of exterior primer applied @ 2.20 kg / 10 m� ) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of engineer in charge. with all lead and lift, loading & unloading, hire charges of machinery and equipments, transportation charges cost and conveyance of all materials, labour charges and all other incidental charges etc., complete as per standard technical detailed specification and design and directions of the engineer incharge of the work ( 1 ) 102.74 ( 2 ) 102.74 ( 3 ) 102.74 ( 4 ) 102.74 ( 5 ) 102.74 ( 6 ) 102.74 ( 7 ) 102.74 sqm 719.18 19 providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of engineer in charge. with all lead and lift, loading & unloading, hire charges of machinery and equipments, transportation charges cost and conveyance of all materials, labour charges and all other incidental charges etc., complete as per standard technical detailed specification and design and directions of the engineer incharge of the work ( 1 ) 58.79 ( 2 ) 58.79 ( 3 ) 58.79 ( 4 ) 58.79 ( 5 ) 58.79 ( 6 ) 58.79 ( 7 ) 58.79 sqm 411.53 20 wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade :two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of engineer in charge. with all lead and lift, loading & unloading, hire charges of machinery and equipments, transportation charges cost and conveyance of all materials, labour charges and all other incidental charges etc., complete as per standard technical detailed specification and design and directions of the engineer incharge of the work ( 1 ) 58.79 ( 2 ) 58.79 ( 3 ) 58.79 ( 4 ) 58.79 ( 5 ) 58.79 ( 6 ) 58.79 ( 7 ) 58.79 sqm 411.53 21 providing and fixing 1mm thick m.s. sheet door with frame of 40x40x6 mm angle iron and 3 mm m.s. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. using m.s. angels 40x40x6 mm for diagonal braces including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the engineer in charge. with all lead and lift, loading & unloading, hire charges of machinery and equipments, transportation charges cost and conveyance of all materials, labour charges and all other incidental charges etc., complete as per standard technical detailed specification and design and directions of the engineer incharge of the work ( 1 ) 2.52 ( 2 ) 2.52 ( 3 ) 2.52 ( 4 ) 2.52 ( 5 ) 2.52 ( 6 ) 2.52 ( 7 ) 2.52 sqm 17.64 22 providing and fixing factory made isi marked steel glazed doors, windows and ventilators, side / top / centre hung, with beading and all members such as f7d, f4b, k11 b and k12 b etc. complete of standard rolled steel sections, joints mitred and flash butt welded and sash bars tenoned and riveted, including providing and fixing of hinges, pivots, including priming coat of approved steel primer, but excluding the cost of other fittings, complete all as per approved design, ( sectional weight of only steel members shall be measured for payment ) . with all lead and lift, loading & unloading, hire charges of machinery and equipments, transportation charges cost and conveyance of all materials, labour charges and all other incidental charges etc., complete as per standard technical detailed specification and design and directions of the engineer incharge of the work ( 1 ) 120.96 ( 2 ) 120.96 ( 3 ) 120.96 ( 4 ) 120.96 ( 5 ) 120.96 ( 6 ) 120.96 ( 7 ) 120.96 kg 846.72 23 painting steel work with deluxe multi surface paint to give an even shade. two coat applied @ 0.90 ltr / 10 m� over an under coat of primer applied @ 0.80 ltr / 10 m� of approved brand and manufacture including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of engineer in charge. with all lead and lift, loading & unloading, hire charges of machinery and equipments, transportation charges cost and conveyance of all materials, labour charges and all other incidental charges etc., complete as per standard technical detailed specification and design and directions of the engineer incharge of the work ( 1 ) 36.63 ( 2 ) 36.63 ( 3 ) 36.63 ( 4 ) 36.63 ( 5 ) 36.63 ( 6 ) 36.63 ( 7 ) 36.63 sqm 256.41 24 providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approved steel primer. m.s. tube including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the engineerin charge.with all lead and lift, loading & unloading, hire charges of machinery and equipments, transportation charges cost and conveyance of all materials, labour charges and all other incidental charges etc., complete as per standard technical detailed specification and design and directions of the engineer incharge of the work ( 1 ) 105.00 ( 2 ) 105.00 ( 3 ) 105.00 ( 4 ) 105.00 ( 5 ) 105.00 ( 6 ) 105.00 ( 7 ) 105.00 kg 735 25 providing and fixing on wall face unplasticised rigid pvc rain water pipes conforming to is : 13592 type a, including jointing with seal ring conforming to is : 5382 leaving 10 mm gap for thermal exxpansion ( i ) single socketed pipe 100 mm diameter with all lead and lift, loading & unloading, hire charges of machinery and equipments, transportation charges cost and conveyance of all materials, labour charges and all other incidental charges etc., complete as per standard technical detailed specification and design and directions of the engineer incharge of the work ( 1 ) 9.00 ( 2 ) 9.00 ( 3 ) 9.00 ( 4 ) 9.00 ( 5 ) 9.00 ( 6 ) 9.00 ( 7 ) 9.00 mtr 63 26 providing and laying water proofing treatment to the roof with pu based single component elastomeric pure polyurethane based coating on new terrace / chajjas / sunken portion of wc:bathroom, cold applied pu waterproofing membrane that is highly elastic with elongation greater than 400% and tensile strength greater than 2mpa as per astm d412. the waterproofing membrane to be applied in 2coats @ 1.6kg per m2 to achieve final dft ( dry film thickness ) of 1mm including prime coat of epoxy primer @150 g per m2 and protection with 120gsm geo textile over the waterproofing membrane. the finished cost to include surface preparation, making coving at junction, bore packing, treatment of construction joints completely as per specification & with a 10 years warranty on product & work from certified manufacturers as per the direction of the engineer in charge.with all lead and lift, loading & unloading, hire charges of machinery and equipments, transportation charges cost and conveyance of all materials, labour charges and all other incidental charges etc., complete as per standard technical detailed specification and design and directions of the engineer incharge of the work ( 1 ) 49.47 ( 2 ) 49.47 ( 3 ) 49.47 ( 4 ) 49.47 ( 5 ) 49.47 ( 6 ) 49.47 ( 7 ) 49.47 sqm 346.29 27 providing wall black boards in cm 1:3 with two coats of black paint including finishing etc., complete. with all lead and lift, loading & unloading, hire charges of machinery and equipments, transportation charges cost and conveyance of all materials, labour charges and all other incidental charges etc., complete as per standard technical detailed specification and design and directions of the engineer incharge of the work ( 1 ) 3.00 ( 2 ) 3.00 ( 3 ) 3.00 ( 4 ) 3.00 ( 5 ) 3.00 ( 6 ) 3.00 ( 7 ) 3.00 sqm 21 28 electrification: supplying heavy gauge pvc conduit pipe ...... mm dia..........mm thick confirming to is 2509 with suitable size bends, metal / pvc junction boxes, adhesive paste etc., and running before concreting the slab. the conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using pvc end enclosures, run with 18swg gi fish wire wherever necessary 19 / 20 mm dia 2 mm thick with all lead and lift, loading & unloading, hire charges of machinery and equipments, transportation charges cost and conveyance of all materials, labour charges and all other incidental charges etc., complete as per standard technical detailed specification and design and directions of the engineer incharge of the work ( 1 ) 30.00 ( 2 ) 30.00 ( 3 ) 30.00 ( 4 ) 30.00 ( 5 ) 30.00 ( 6 ) 30.00 ( 7 ) 30.00 mtr 210 29 upplying heavy gauge pvc conduit pipe .... dia ....... mm thick with suitable size bends, metal junction boxes adhesive paste etc., by groove cutting in the wall and fixing by bracing u or j hooks and cement plastering upto the wall surface and run with 18 swg gi fish wire run throughout the conduit wherever necessary 19 / 20 mm dia 2 mm thick with all lead and lift, loading & unloading, hire charges of machinery and equipments, transportation charges cost and conveyance of all materials, labour charges and all other incidental charges etc., complete as per standard technical detailed specification and design and directions of the engineer incharge of the work ( 1 ) 20.00 ( 2 ) 20.00 ( 3 ) 20.00 ( 4 ) 20.00 ( 5 ) 20.00 ( 6 ) 20.00 ( 7 ) 20.00 mtr 140 30 supplying and fixing sheet metal box made out of 18 swg sheet metal with necessary holes for cable / conduit entry as required with one coat of primer of approved make etc.135 x 75 x 65 mm with all lead and lift, loading & unloading, hire charges of machinery and equipments, transportation charges cost and conveyance of all materials, labour charges and all other incidental charges etc., complete as per standard technical detailed specification and design and directions of the engineer incharge of the work ( 1 ) 2 ( 2 ) 2 ( 3 ) 2 ( 4 ) 2 ( 5 ) 2 ( 6 ) 2 ( 7 ) 2 each 14 31 supplying and fixing sheet metal box made out of 18 swg sheet metal with necessary holes for cable / conduit entry as required with one coat of primer of approved make etc. 200 x 200 x 65 mm with all lead and lift, loading & unloading, hire charges of machinery and equipments, transportation charges cost and conveyance of all materials, labour charges and all other incidental charges etc., complete as per standard technical detailed specification and design and directions of the engineer incharge of the work ( 1 ) 1 ( 2 ) 1 ( 3 ) 1 ( 4 ) 1 ( 5 ) 1 ( 6 ) 1 ( 7 ) 1 each 7 32 supplying and fixing pvc / metal conduit deep junction box 32 mm deep junction box with all lead and lift, loading & unloading, hire charges of machinery and equipments, transportation charges cost and conveyance of all materials, labour charges and all other incidental charges etc., complete as per standard technical detailed specification and design and directions of the engineer incharge of the work ( 1 ) 7 ( 2 ) 7 ( 3 ) 7 ( 4 ) 7 ( 5 ) 7 ( 6 ) 7 ( 7 ) 7 each 49 33 supplying and fixing metal fan box with round hook. with all lead and lift, loading & unloading, hire charges of machinery and equipments, transportation charges cost and conveyance of all materials, labour charges and all other incidental charges etc., complete as per standard technical detailed specification and design and directions of the engineer incharge of the work ( 1 ) 7 ( 2 ) 7 ( 3 ) 7 ( 4 ) 7 ( 5 ) 7 ( 6 ) 7 ( 7 ) 7 each 49 34 supplying and wiring adopting loop system in existing pvc conduit / casing capping casing capping using 2x1.5mm2 ( phase & neutral ) & 1x1.0 mm2 ( earth wire ) frls multi strand pvc insulated copper wire ( confirming to is 694: and latest amendments ) without control switch shall be fixed on the existing plastic sheet / gang box, the other end of the wires shall be terminated with sufficient loose length in a wood / pvc round block. complete for each outlet. medium point above 3m upto 6m from tapping point to out let via switch box with all lead and lift, loading & unloading, hire charges of machinery and equipments, transportation charges cost and conveyance of all materials, labour charges and all other incidental charges etc., complete as per standard technical detailed specification and design and directions of the engineer incharge of the work ( 1 ) 10 ( 2 ) 10 ( 3 ) 10 ( 4 ) 10 ( 5 ) 10 ( 6 ) 10 ( 7 ) 10 point 70 35 wiring for lighting / power circuit using one of frls pvc insulated 1100v grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified is 694:confirming to latest amendments. 1.5 mm2 with all lead and lift, loading & unloading, hire charges of machinery and equipments, transportation charges cost and conveyance of all materials, labour charges and all other incidental charges etc., complete as per standard technical detailed specification and design and directions of the engineer incharge of the work ( 1 ) 20.00 ( 2 ) 20.00 ( 3 ) 20.00 ( 4 ) 20.00 ( 5 ) 20.00 ( 6 ) 20.00 ( 7 ) 20.00 mtr 140 36 supplying and drawing flexible multicore cable manufactured with electrolytic grade flexible copper with low conductor confirming to is 8130 1984 and ( virgin ) pvc insulation sheathed suitable for working voltage upto 1100v as per is694:2010 3c x 4 mm2 with all lead and lift, loading & unloading, hire charges of machinery and equipments, transportation charges cost and conveyance of all materials, labour charges and all other incidental charges etc., complete as per standard technical detailed specification and design and directions of the engineer incharge of the work ( 1 ) 30.00 ( 2 ) 30.00 ( 3 ) 30.00 ( 4 ) 30.00 ( 5 ) 30.00 ( 6 ) 30.00 ( 7 ) 30.00 mtr 210 37 supplying and fixing surface / flush mounting unbreakable pvc modular box suitable for mounting modular switch plates with due groove cutting in brick / c.c wall, including necessary rawl plugs, machine / nf screws etc., complete. 6 way with all lead and lift, loading & unloading, hire charges of machinery and equipments, transportation charges cost and conveyance of all materials, labour charges and all other incidental charges etc., complete as per standard technical detailed specification and design and directions of the engineer incharge of the work ( 1 ) 2 ( 2 ) 2 ( 3 ) 2 ( 4 ) 2 ( 5 ) 2 ( 6 ) 2 ( 7 ) 2 each 14 38 supplying and fixing surface / flush mounting unbreakable pvc modular box suitable for mounting modular switch plates with due groove cutting in brick / c.c wall, including necessary rawl plugs, machine / nf screws etc., complete. 16 18 way with all lead and lift, loading & unloading, hire charges of machinery and equipments, transportation charges cost and conveyance of all materials, labour charges and all other incidental charges etc., complete as per standard technical detailed specification and design and directions of the engineer incharge of the work ( 1 ) 1 ( 2 ) 1 ( 3 ) 1 ( 4 ) 1 ( 5 ) 1 ( 6 ) 1 ( 7 ) 1 each 7 39 supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal / pvc box 6 way with all lead and lift, loading & unloading, hire charges of machinery and equipments, transportation charges cost and conveyance of all materials, labour charges and all other incidental charges etc., complete as per standard technical detailed specification and design and directions of the engineer incharge of the work ( 1 ) 2 ( 2 ) 2 ( 3 ) 2 ( 4 ) 2 ( 5 ) 2 ( 6 ) 2 ( 7 ) 2 each 14 40 supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal / pvc box 16 18 way with all lead and lift, loading & unloading, hire charges of machinery and equipments, transportation charges cost and conveyance of all materials, labour charges and all other incidental charges etc., complete as per standard technical detailed specification and design and directions of the engineer incharge of the work ( 1 ) 1 ( 2 ) 1 ( 3 ) 1 ( 4 ) 1 ( 5 ) 1 ( 6 ) 1 ( 7 ) 1 each 7 41 supplying and fixing of modular switch & connected accessories on existing modular switch plate as per is 3854 and is 1293. 6a one way switch with all lead and lift, loading & unloading, hire charges of machinery and equipments, transportation charges cost and conveyance of all materials, labour charges and all other incidental charges etc., complete as per standard technical detailed specification and design and directions of the engineer incharge of the work ( 1 ) 7 ( 2 ) 7 ( 3 ) 7 ( 4 ) 7 ( 5 ) 7 ( 6 ) 7 ( 7 ) 7 each 49 42 supplying and fixing of modular switch & connected accessories on existing modular switch plate as per is 3854 and is 1293. stepped fan regulator two module with all lead and lift, loading & unloading, hire charges of machinery and equipments, transportation charges cost and conveyance of all materials, labour charges and all other incidental charges etc., complete as per standard technical detailed specification and design and directions of the engineer incharge of the work ( 1 ) 3 ( 2 ) 3 ( 3 ) 3 ( 4 ) 3 ( 5 ) 3 ( 6 ) 3 ( 7 ) 3 each 21 43 supplying and fixing of modular switch & connected accessories on existing modular switch plate as per is 3854 and is 1293. 16a one way switch with all lead and lift, loading & unloading, hire charges of machinery and equipments, transportation charges cost and conveyance of all materials, labour charges and all other incidental charges etc., complete as per standard technical detailed specification and design and directions of the engineer incharge of the work ( 1 ) 2 ( 2 ) 2 ( 3 ) 2 ( 4 ) 2 ( 5 ) 2 ( 6 ) 2 ( 7 ) 2 each 14 44 supplying and fixing of modular switch & connected accessories on existing modular switch plate as per is 3854 and is 1293. 6 / 16a universal socket with all lead and lift, loading & unloading, hire charges of machinery and equipments, transportation charges cost and conveyance of all materials, labour charges and all other incidental charges etc., complete as per standard technical detailed specification and design and directions of the engineer incharge of the work ( 1 ) 1 ( 2 ) 1 ( 3 ) 1 ( 4 ) 1 ( 5 ) 1 ( 6 ) 1 ( 7 ) 1 each 7 45 supplying and fixing of modular switch & connected accessories on existing modular switch plate as per is 3854 and is 1293. rj45 / i.o outlet cat 6 with all lead and lift, loading & unloading, hire charges of machinery and equipments, transportation charges cost and conveyance of all materials, labour charges and all other incidental charges etc., complete as per standard technical detailed specification and design and directions of the engineer incharge of the work ( 1 ) 1 ( 2 ) 1 ( 3 ) 1 ( 4 ) 1 ( 5 ) 1 ( 6 ) 1 ( 7 ) 1 each 7 46 supplying and fixing regular mccb distribution panel confirming to is / iec 61439 3 and ik09 tested as per is / iec 62262 with minimum ip43 protection provided with polyurethane ( pur ) gasket, with suitable earthing system, on wall / wood board / flush mounting using required cl a , bolts, nuts, etc., with provision for fixing of suitable type capacity mccbs as an incomer for 3 phase double door with necessary bus bar completely wired to use on 440v 3phase 4 wire powder coated painting etc., complete with a provision for fixing of single / three phase suitable capacity mcbs as outgoings confirming to is / iec 60898 4 way with all lead and lift, loading & unloading, hire charges of machinery and equipments, transportation charges cost and conveyance of all materials, labour charges and all other incidental charges etc., complete as per standard technical detailed specification and design and directions of the engineer incharge of the work ( 1 ) 1 ( 2 ) 1 ( 3 ) 1 ( 4 ) 1 ( 5 ) 1 ( 6 ) 1 ( 7 ) 1 each 7 47 supplying, fixing and wiring residual current circuit breaker ( rccb ) 240 / 450v upto 300ma sensitivity on existing wood / panel board. 32 40a 2 pole. with all lead and lift, loading & unloading, hire charges of machinery and equipments, transportation charges cost and conveyance of all materials, labour charges and all other incidental charges etc., complete as per standard technical detailed specification and design and directions of the engineer incharge of the work ( 1 ) 1 ( 2 ) 1 ( 3 ) 1 ( 4 ) 1 ( 5 ) 1 ( 6 ) 1 ( 7 ) 1 each 7 48 supplying & fixing miniature circuit breakers on existing mcb distribution boards using necessary fixing materials and c type curve, indicator on / off, energy cross 3 with short circuit breaking capacity of 10k and complete wiring as required confirming to iec 60898. 6 32 a sp with all lead and lift, loading & unloading, hire charges of machinery and equipments, transportation charges cost and conveyance of all materials, labour charges and all other incidental charges etc., complete as per standard technical detailed specification and design and directions of the engineer incharge of the work ( 1 ) 1 ( 2 ) 1 ( 3 ) 1 ( 4 ) 1 ( 5 ) 1 ( 6 ) 1 ( 7 ) 1 each 7 49 supplying capacitor type ceiling fan complete with down rod blades, shackle, canopies etc, for operation on 230 v, 50 cycles. single phase ac supply conforming to iss 374 1979 and with double ball bearing system. 48 sweep ( 1200 mm ) regular model with all lead and lift, loading & unloading, hire charges of machinery and equipments, transportation charges cost and conveyance of all materials, labour charges and all other incidental charges etc., complete as per standard technical detailed specification and design and directions of the engineer incharge of the work ( 1 ) 2 ( 2 ) 2 ( 3 ) 2 ( 4 ) 2 ( 5 ) 2 ( 6 ) 2 ( 7 ) 2 each 14 50 fixing a ceiling / wall mounting fan of all capacities and all types, with necessary cla and s hook made out of 15mm dia ms rod, with 5 a. ceiling rose of approved quality with necessary length of 23 / 0.0076 inch pvc insulated twin twisted wire of approved quality, mounted on a suitable size wooden board and wired. with all lead and lift, loading & unloading, hire charges of machinery and equipments, transportation charges cost and conveyance of all materials, labour charges and all other incidental charges etc., complete as per standard technical detailed specification and design and directions of the engineer incharge of the work ( 1 ) 2 ( 2 ) 2 ( 3 ) 2 ( 4 ) 2 ( 5 ) 2 ( 6 ) 2 ( 7 ) 2 each 14 51 supplying of .....feet pvc batten with integrated led tube .... w with high quality diffuser with life of 25000 burning hours & 70% lumen maintenance with cri > 80. power input: 220 240v@ 50 / 60hz & power factor >0.9 along with ce approved. 2 years warranty against any manufacturing defect working under standard electrical condition. led light fitting 1 x 4 20 / 22 w with all lead and lift, loading & unloading, hire charges of machinery and equipments, transportation charges cost and conveyance of all materials, labour charges and all other incidental charges etc., complete as per standard technical detailed specification and design and directions of the engineer incharge of the work ( 1 ) 7 ( 2 ) 7 ( 3 ) 7 ( 4 ) 7 ( 5 ) 7 ( 6 ) 7 ( 7 ) 7 each 49 52 supplying, fixing, wiring, earth electrode for grounding conduits, i.c. cutouts and other equipments on the meter board using 40mm dia 2.90mm thick gi pipe 2.5 mtr long buried in a pit … the pit should be filled with equal proportion of salt and charcoal 150mm all round the pipe to complete depth. the connection from the pipe to the conduit etc., is to be established through gi wire of size as per isi specification 7.3.3. of is 732 using 12mm dia bolts, nuts, washers and check nuts etc., the pipe shall have 16 through holes of 12 mm diawith all lead and lift, loading & unloading, hire charges of machinery and equipments, transportation charges cost and conveyance of all materials, labour charges and all other incidental charges etc., complete as per standard technical detailed specification and design and directions of the engineer incharge of the work ( 1 ) 1 ( 2 ) 1 ( 3 ) 1 ( 4 ) 1 ( 5 ) 1 ( 6 ) 1 ( 7 ) 1 no 7 53 supplying, fixing and wiring electronic trivector meter ( etv ) 5 to 20a single phase class 1 accuracy with temper proof energy meter. with all lead and lift, loading & unloading, hire charges of machinery and equipments, transportation charges cost and conveyance of all materials, labour charges and all other incidental charges etc., complete as per standard technical detailed specification and design and directions of the engineer incharge of the work ( 1 ) 1 ( 2 ) 1 ( 3 ) 1 ( 4 ) 1 ( 5 ) 1 ( 6 ) 1 ( 7 ) 1 each 7 54 bescom deposite including supervision and agreement charges ( 1 ) 1 ( 2 ) 1 ( 3 ) 1 ( 4 ) 1 ( 5 ) 1 ( 6 ) 1 ( 7 ) 1...

Rural Development Panchayath Raj Engineering Department - Karnataka

34502999 tender for turuvekere taluk package no: tmk tvk 47 / 22 23 1 civil work: earth work excavation by manual means for drains, canals, waste weir, draft, approach channels, key trenches, foundation of bridges and such simillar works in all kinds of soils , as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m including cost of labour, tools & other appurtenaces required to complete the work. in all kinds of soils depth upto 1.5 m with all lead and lift, loading & unloading, hire charges of machinery and equipments, transportation charges cost and conveyance of all materials, labour charges and all other incidental charges etc., complete as per standard technical detailed specification and design and directions of the engineer incharge of the work ( 1 ) 46.93 ( 2 ) 46.93 ( 3 ) 46.93 ( 4 ) 46.93 ( 5 ) 46.93 ( 6 ) 46.93 ( 7 ) 46.93 cum 328.51 2 filling available excavated earth ( excluding rock ) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering with all lead and lift, loading & unloading, hire charges of machinery and equipments, transportation charges cost and conveyance of all materials, labour charges and all other incidental charges etc., complete as per standard technical detailed specification and design and directions of the engineer incharge of the work ( 1 ) 32.85 ( 2 ) 32.85 ( 3 ) 32.85 ( 4 ) 32.85 ( 5 ) 32.85 ( 6 ) 32.85 ( 7 ) 32.85 cum 229.95 3 providing and laying in position plain cement concrete for levelling course for all works in foundation. the granite / trap / basalt crushed graded coarse aggregates and fine aggregates as per relevant is codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. ( the cost of steel reinforcement & formwork shall be paid separately ) mix 1:4:8 ( m5 ) using 40 mm nominal size graded crushed coarse aggregates with all lead and lift, loading & unloading, hire charges of machinery and equipments, transportation charges cost and conveyance of all materials, labour charges and all other incidental charges etc., complete as per standard technical detailed specification and design and directions of the engineer incharge of the work ( 1 ) 11.67 ( 2 ) 11.67 ( 3 ) 11.67 ( 4 ) 11.67 ( 5 ) 11.67 ( 6 ) 11.67 ( 7 ) 11.67 cum 81.69 4 providing random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 ( 1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size ) upto plinth level with : cement mortar 1:6 ( 1 cement : 6 coarse sand ) with all lead and lift, loading & unloading, hire charges of machinery and equipments, transportation charges cost and conveyance of all materials, labour charges and all other incidental charges etc., complete as per standard technical detailed specification and design and directions of the engineer incharge of the work ( 1 ) 12.12 ( 2 ) 12.12 ( 3 ) 12.12 ( 4 ) 12.12 ( 5 ) 12.12 ( 6 ) 12.12 ( 7 ) 12.12 cum 84.84 5 providing coursed rubble masonry ( second sort ) with hard stone in foundation & plinth with cement mortar 1:6 ( 1 cement : 6 coarse sand ) with all lead and lift, loading & unloading, hire charges of machinery and equipments, transportation charges cost and conveyance of all materials, labour charges and all other incidental charges etc., complete as per standard technical detailed specification and design and directions of the engineer incharge of the work ( 1 ) 6.84 ( 2 ) 6.84 ( 3 ) 6.84 ( 4 ) 6.84 ( 5 ) 6.84 ( 6 ) 6.84 ( 7 ) 6.84 cum 47.88 6 appendix i – additionalities for formwork, centering 1. foundation upto plinth a ) isolated 8% with all lead and lift, loading & unloading, hire charges of machinery and equipments, transportation charges cost and conveyance of all materials, labour charges and all other incidental charges etc., complete as per standard technical detailed specification and design and directions of the engineer incharge of the work ( 1 ) 17.81 ( 2 ) 17.81 ( 3 ) 17.81 ( 4 ) 17.81 ( 5 ) 17.81 ( 6 ) 17.81 ( 7 ) 17.81 cum 124.67 7 providing and laying in position reinforced cement concrete for all foundation works. the granite / trap / basalt crushed graded coarse aggregates and fine aggregates as per relevant is codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant is codes , labour, usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. ( the cost of steel reinforcement & formwork to be paid separately ) m20 design mix using 20 mm nominal size graded crushed coarse with all lead and lift, loading & unloading, hire charges of machinery and equipments, transportation charges cost and conveyance of all materials, labour charges and all other incidental charges etc., complete as per standard technical detailed specification and design and directions of the engineer incharge of the work ( 1 ) 17.81 ( 2 ) 17.81 ( 3 ) 17.81 ( 4 ) 17.81 ( 5 ) 17.81 ( 6 ) 17.81 ( 7 ) 17.81 cum 124.67 8 appendix i – additionalities for formwork, centering 8. columns & piers 10%with all lead and lift, loading & unloading, hire charges of machinery and equipments, transportation charges cost and conveyance of all materials, labour charges and all other incidental charges etc., complete as per standard technical detailed specification and design and directions of the engineer incharge of the work ( 1 ) 4.17 ( 2 ) 4.17 ( 3 ) 4.17 ( 4 ) 4.17 ( 5 ) 4.17 ( 6 ) 4.17 ( 7 ) 4.17 cum 29.19 9 appendix i – additionalities for formwork, centering 12. beams & lintels of building 20% 13. roof ( straight & arched ) 20% with all lead and lift, loading & unloading, hire charges of machinery and equipments, transportation charges cost and conveyance of all materials, labour charges and all other incidental charges etc., complete as per standard technical detailed specification and design and directions of the engineer incharge of the work ( 1 ) 15.13 ( 2 ) 15.13 ( 3 ) 15.13 ( 4 ) 15.13 ( 5 ) 15.13 ( 6 ) 15.13 ( 7 ) 15.13 cum 105.91 10 providing thermo mechanically treated bars of grade fe 550d or more steel reinforcement for r.c.c. work including straightening, cutting, bending, placing in position, binding and anchoring to adjacent members whereever necessary complete as per design including cost of material, labour, usage charges complete as per specifications. ( the laps and wastages shall not be measured separately ) with all lead and lift, loading & unloading, hire charges of machinery and equipments, transportation charges cost and conveyance of all materials, labour charges and all other incidental charges etc., complete as per standard technical detailed specification and design and directions of the engineer incharge of the work ( 1 ) 2720.00 ( 2 ) 2720.00 ( 3 ) 2720.00 ( 4 ) 2720.00 ( 5 ) 2720.00 ( 6 ) 2720.00 ( 7 ) 2720.00 kg 19040 11 providing and laying in position reinforced cement concrete for all super structures of building , road works, water works, irrigation works & super structure works of bridges upto 3.50 m height. the granite / trap / basalt crushed graded coarse aggregates and fine aggregates as per relevant is codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. the cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant is codes , labour, usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. ( the cost of steel reinforcement, dowel bars & formwork to be paid separately ) m20 design mix using 20 mm nominal size graded crushed coarse aggregates with all lead and lift, loading & unloading, hire charges of machinery and equipments, transportation charges cost and conveyance of all materials, labour charges and all other incidental charges etc., complete as per standard technical detailed specification and design and directions of the engineer incharge of the work ( 1 ) 20.65 ( 2 ) 20.65 ( 3 ) 20.65 ( 4 ) 20.65 ( 5 ) 20.65 ( 6 ) 20.65 ( 7 ) 20.65 cum 144.55 12 ksrb 4.2.10 : providing and laying in position reinforced cement concrete of design mix m20 with opc cement @ 24kgs, with 2mm and down size graded granite metal coares aggregates @ 0.5175cum and fine aggregates @ 0.345cum, with superplastisiser @ 0.225lts, machine mixed, well compacted for plain chajja of 7.5cms average thickness, upto ground floor level including cost of all materials, labour, hom of machinery, curing, complete as per specifications. specification no. kbs 4.1, 4.6 with all lead and lift, loading & unloading, hire charges of machinery and equipments, transportation charges cost and conveyance of all materials, labour charges and all other incidental charges etc., complete as per standard technical detailed specification and design and directions of the engineer incharge of the work ( 1 ) 2.16 ( 2 ) 2.16 ( 3 ) 2.16 ( 4 ) 2.16 ( 5 ) 2.16 ( 6 ) 2.16 ( 7 ) 2.16 sqm 15.12 13 providing brick work with common burnt clay non modular bricks of class designation 3.5 in foundation and plinth in cement mortar 1:4 ( 1 cement : 4 coarse sand ) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work. with all lead and lift, loading & unloading, hire charges of machinery and equipments, transportation charges cost and conveyance of all materials, labour charges and all other incidental charges etc., complete as per standard technical detailed specification and design and directions of the engineer incharge of the work ( 1 ) 24.68 ( 2 ) 24.68 ( 3 ) 24.68 ( 4 ) 24.68 ( 5 ) 24.68 ( 6 ) 24.68 ( 7 ) 24.68 cum 172.76 14 providing 12 mm cement plaster with cement mortar 1:4 ( 1 cement: 4 fine sand ) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of engineer in charge. with all lead and lift, loading & unloading, hire charges of machinery and equipments, transportation charges cost and conveyance of all materials, labour charges and all other incidental charges etc., complete as per standard technical detailed specification and design and directions of the engineer incharge of the work ( 1 ) 44.46 ( 2 ) 44.46 ( 3 ) 44.46 ( 4 ) 44.46 ( 5 ) 44.46 ( 6 ) 44.46 ( 7 ) 44.46 sqm 311.22 15 providing 15 mm cement plaster on the rough side of single or half brick wall of mix 1:4 ( 1 cement: 4 fine sand ) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of engineer in charge. with all lead and lift, loading & unloading, hire charges of machinery and equipments, transportation charges cost and conveyance of all materials, labour charges and all other incidental charges etc., complete as per standard technical detailed specification and design and directions of the engineer incharge of the work ( 1 ) 58.28 ( 2 ) 58.28 ( 3 ) 58.28 ( 4 ) 58.28 ( 5 ) 58.28 ( 6 ) 58.28 ( 7 ) 58.28 sqm 407.96 16 providing 20 mm cement plaster of mix :1:4 ( 1 cement: 4 fine sand ) to brick / stone masonary including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of engineer in charge. with all lead and lift, loading & unloading, hire charges of machinery and equipments, transportation charges cost and conveyance of all materials, labour charges and all other incidental charges etc., complete as per standard technical detailed specification and design and directions of the engineer incharge of the work ( 1 ) 171.64 ( 2 ) 171.64 ( 3 ) 171.64 ( 4 ) 171.64 ( 5 ) 171.64 ( 6 ) 171.64 ( 7 ) 171.64 sqm 1201.48 17 flooring with 25mm thick polished tandur blue stone slabs using cement mortar 1:6, 25mm thick over existing cement concrete bed or top of roof laid to line and level and jointed with cement slurry mixed with pigment to match the shade of the slab, , including cost of materials, labour, curing, polishing complete as per specifications. with all lead and lift, loading & unloading, hire charges of machinery and equipments, transportation charges cost and conveyance of all materials, labour charges and all other incidental charges etc., complete as per standard technical detailed specification and design and directions of the engineer incharge of the work ( 1 ) 58.79 ( 2 ) 58.79 ( 3 ) 58.79 ( 4 ) 58.79 ( 5 ) 58.79 ( 6 ) 58.79 ( 7 ) 58.79 sqm 411.53 18 finishing walls with acrylic smooth exterior paint of required shade :new work ( two coat applied @ 1.67 ltr / 10 m� over and including priming coat of exterior primer applied @ 2.20 kg / 10 m� ) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of engineer in charge. with all lead and lift, loading & unloading, hire charges of machinery and equipments, transportation charges cost and conveyance of all materials, labour charges and all other incidental charges etc., complete as per standard technical detailed specification and design and directions of the engineer incharge of the work ( 1 ) 102.74 ( 2 ) 102.74 ( 3 ) 102.74 ( 4 ) 102.74 ( 5 ) 102.74 ( 6 ) 102.74 ( 7 ) 102.74 sqm 719.18 19 providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of engineer in charge. with all lead and lift, loading & unloading, hire charges of machinery and equipments, transportation charges cost and conveyance of all materials, labour charges and all other incidental charges etc., complete as per standard technical detailed specification and design and directions of the engineer incharge of the work ( 1 ) 58.79 ( 2 ) 58.79 ( 3 ) 58.79 ( 4 ) 58.79 ( 5 ) 58.79 ( 6 ) 58.79 ( 7 ) 58.79 sqm 411.53 20 wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade :two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of engineer in charge. with all lead and lift, loading & unloading, hire charges of machinery and equipments, transportation charges cost and conveyance of all materials, labour charges and all other incidental charges etc., complete as per standard technical detailed specification and design and directions of the engineer incharge of the work ( 1 ) 58.79 ( 2 ) 58.79 ( 3 ) 58.79 ( 4 ) 58.79 ( 5 ) 58.79 ( 6 ) 58.79 ( 7 ) 58.79 sqm 411.53 21 providing and fixing 1mm thick m.s. sheet door with frame of 40x40x6 mm angle iron and 3 mm m.s. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. using m.s. angels 40x40x6 mm for diagonal braces including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the engineer in charge. with all lead and lift, loading & unloading, hire charges of machinery and equipments, transportation charges cost and conveyance of all materials, labour charges and all other incidental charges etc., complete as per standard technical detailed specification and design and directions of the engineer incharge of the work ( 1 ) 2.52 ( 2 ) 2.52 ( 3 ) 2.52 ( 4 ) 2.52 ( 5 ) 2.52 ( 6 ) 2.52 ( 7 ) 2.52 sqm 17.64 22 providing and fixing factory made isi marked steel glazed doors, windows and ventilators, side / top / centre hung, with beading and all members such as f7d, f4b, k11 b and k12 b etc. complete of standard rolled steel sections, joints mitred and flash butt welded and sash bars tenoned and riveted, including providing and fixing of hinges, pivots, including priming coat of approved steel primer, but excluding the cost of other fittings, complete all as per approved design, ( sectional weight of only steel members shall be measured for payment ) . with all lead and lift, loading & unloading, hire charges of machinery and equipments, transportation charges cost and conveyance of all materials, labour charges and all other incidental charges etc., complete as per standard technical detailed specification and design and directions of the engineer incharge of the work ( 1 ) 120.96 ( 2 ) 120.96 ( 3 ) 120.96 ( 4 ) 120.96 ( 5 ) 120.96 ( 6 ) 120.96 ( 7 ) 120.96 kg 846.72 23 painting steel work with deluxe multi surface paint to give an even shade. two coat applied @ 0.90 ltr / 10 m� over an under coat of primer applied @ 0.80 ltr / 10 m� of approved brand and manufacture including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of engineer in charge. with all lead and lift, loading & unloading, hire charges of machinery and equipments, transportation charges cost and conveyance of all materials, labour charges and all other incidental charges etc., complete as per standard technical detailed specification and design and directions of the engineer incharge of the work ( 1 ) 36.63 ( 2 ) 36.63 ( 3 ) 36.63 ( 4 ) 36.63 ( 5 ) 36.63 ( 6 ) 36.63 ( 7 ) 36.63 sqm 256.41 24 providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approved steel primer. m.s. tube including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the engineerin charge.with all lead and lift, loading & unloading, hire charges of machinery and equipments, transportation charges cost and conveyance of all materials, labour charges and all other incidental charges etc., complete as per standard technical detailed specification and design and directions of the engineer incharge of the work ( 1 ) 105.00 ( 2 ) 105.00 ( 3 ) 105.00 ( 4 ) 105.00 ( 5 ) 105.00 ( 6 ) 105.00 ( 7 ) 105.00 kg 735 25 providing and fixing on wall face unplasticised rigid pvc rain water pipes conforming to is : 13592 type a, including jointing with seal ring conforming to is : 5382 leaving 10 mm gap for thermal exxpansion ( i ) single socketed pipe 100 mm diameter with all lead and lift, loading & unloading, hire charges of machinery and equipments, transportation charges cost and conveyance of all materials, labour charges and all other incidental charges etc., complete as per standard technical detailed specification and design and directions of the engineer incharge of the work ( 1 ) 9.00 ( 2 ) 9.00 ( 3 ) 9.00 ( 4 ) 9.00 ( 5 ) 9.00 ( 6 ) 9.00 ( 7 ) 9.00 mtr 63 26 providing and laying water proofing treatment to the roof with pu based single component elastomeric pure polyurethane based coating on new terrace / chajjas / sunken portion of wc:bathroom, cold applied pu waterproofing membrane that is highly elastic with elongation greater than 400% and tensile strength greater than 2mpa as per astm d412. the waterproofing membrane to be applied in 2coats @ 1.6kg per m2 to achieve final dft ( dry film thickness ) of 1mm including prime coat of epoxy primer @150 g per m2 and protection with 120gsm geo textile over the waterproofing membrane. the finished cost to include surface preparation, making coving at junction, bore packing, treatment of construction joints completely as per specification & with a 10 years warranty on product & work from certified manufacturers as per the direction of the engineer in charge.with all lead and lift, loading & unloading, hire charges of machinery and equipments, transportation charges cost and conveyance of all materials, labour charges and all other incidental charges etc., complete as per standard technical detailed specification and design and directions of the engineer incharge of the work ( 1 ) 49.47 ( 2 ) 49.47 ( 3 ) 49.47 ( 4 ) 49.47 ( 5 ) 49.47 ( 6 ) 49.47 ( 7 ) 49.47 sqm 346.29 27 providing wall black boards in cm 1:3 with two coats of black paint including finishing etc., complete. with all lead and lift, loading & unloading, hire charges of machinery and equipments, transportation charges cost and conveyance of all materials, labour charges and all other incidental charges etc., complete as per standard technical detailed specification and design and directions of the engineer incharge of the work ( 1 ) 3.00 ( 2 ) 3.00 ( 3 ) 3.00 ( 4 ) 3.00 ( 5 ) 3.00 ( 6 ) 3.00 ( 7 ) 3.00 sqm 21 28 electrification: supplying heavy gauge pvc conduit pipe ...... mm dia..........mm thick confirming to is 2509 with suitable size bends, metal / pvc junction boxes, adhesive paste etc., and running before concreting the slab. the conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using pvc end enclosures, run with 18swg gi fish wire wherever necessary 19 / 20 mm dia 2 mm thick with all lead and lift, loading & unloading, hire charges of machinery and equipments, transportation charges cost and conveyance of all materials, labour charges and all other incidental charges etc., complete as per standard technical detailed specification and design and directions of the engineer incharge of the work ( 1 ) 30.00 ( 2 ) 30.00 ( 3 ) 30.00 ( 4 ) 30.00 ( 5 ) 30.00 ( 6 ) 30.00 ( 7 ) 30.00 mtr 210 29 upplying heavy gauge pvc conduit pipe .... dia ....... mm thick with suitable size bends, metal junction boxes adhesive paste etc., by groove cutting in the wall and fixing by bracing u or j hooks and cement plastering upto the wall surface and run with 18 swg gi fish wire run throughout the conduit wherever necessary 19 / 20 mm dia 2 mm thick with all lead and lift, loading & unloading, hire charges of machinery and equipments, transportation charges cost and conveyance of all materials, labour charges and all other incidental charges etc., complete as per standard technical detailed specification and design and directions of the engineer incharge of the work ( 1 ) 20.00 ( 2 ) 20.00 ( 3 ) 20.00 ( 4 ) 20.00 ( 5 ) 20.00 ( 6 ) 20.00 ( 7 ) 20.00 mtr 140 30 supplying and fixing sheet metal box made out of 18 swg sheet metal with necessary holes for cable / conduit entry as required with one coat of primer of approved make etc.135 x 75 x 65 mm with all lead and lift, loading & unloading, hire charges of machinery and equipments, transportation charges cost and conveyance of all materials, labour charges and all other incidental charges etc., complete as per standard technical detailed specification and design and directions of the engineer incharge of the work ( 1 ) 2 ( 2 ) 2 ( 3 ) 2 ( 4 ) 2 ( 5 ) 2 ( 6 ) 2 ( 7 ) 2 each 14 31 supplying and fixing sheet metal box made out of 18 swg sheet metal with necessary holes for cable / conduit entry as required with one coat of primer of approved make etc. 200 x 200 x 65 mm with all lead and lift, loading & unloading, hire charges of machinery and equipments, transportation charges cost and conveyance of all materials, labour charges and all other incidental charges etc., complete as per standard technical detailed specification and design and directions of the engineer incharge of the work ( 1 ) 1 ( 2 ) 1 ( 3 ) 1 ( 4 ) 1 ( 5 ) 1 ( 6 ) 1 ( 7 ) 1 each 7 32 supplying and fixing pvc / metal conduit deep junction box 32 mm deep junction box with all lead and lift, loading & unloading, hire charges of machinery and equipments, transportation charges cost and conveyance of all materials, labour charges and all other incidental charges etc., complete as per standard technical detailed specification and design and directions of the engineer incharge of the work ( 1 ) 7 ( 2 ) 7 ( 3 ) 7 ( 4 ) 7 ( 5 ) 7 ( 6 ) 7 ( 7 ) 7 each 49 33 supplying and fixing metal fan box with round hook. with all lead and lift, loading & unloading, hire charges of machinery and equipments, transportation charges cost and conveyance of all materials, labour charges and all other incidental charges etc., complete as per standard technical detailed specification and design and directions of the engineer incharge of the work ( 1 ) 7 ( 2 ) 7 ( 3 ) 7 ( 4 ) 7 ( 5 ) 7 ( 6 ) 7 ( 7 ) 7 each 49 34 supplying and wiring adopting loop system in existing pvc conduit / casing capping casing capping using 2x1.5mm2 ( phase & neutral ) & 1x1.0 mm2 ( earth wire ) frls multi strand pvc insulated copper wire ( confirming to is 694: and latest amendments ) without control switch shall be fixed on the existing plastic sheet / gang box, the other end of the wires shall be terminated with sufficient loose length in a wood / pvc round block. complete for each outlet. medium point above 3m upto 6m from tapping point to out let via switch box with all lead and lift, loading & unloading, hire charges of machinery and equipments, transportation charges cost and conveyance of all materials, labour charges and all other incidental charges etc., complete as per standard technical detailed specification and design and directions of the engineer incharge of the work ( 1 ) 10 ( 2 ) 10 ( 3 ) 10 ( 4 ) 10 ( 5 ) 10 ( 6 ) 10 ( 7 ) 10 point 70 35 wiring for lighting / power circuit using one of frls pvc insulated 1100v grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified is 694:confirming to latest amendments. 1.5 mm2 with all lead and lift, loading & unloading, hire charges of machinery and equipments, transportation charges cost and conveyance of all materials, labour charges and all other incidental charges etc., complete as per standard technical detailed specification and design and directions of the engineer incharge of the work ( 1 ) 20.00 ( 2 ) 20.00 ( 3 ) 20.00 ( 4 ) 20.00 ( 5 ) 20.00 ( 6 ) 20.00 ( 7 ) 20.00 mtr 140 36 supplying and drawing flexible multicore cable manufactured with electrolytic grade flexible copper with low conductor confirming to is 8130 1984 and ( virgin ) pvc insulation sheathed suitable for working voltage upto 1100v as per is694:2010 3c x 4 mm2 with all lead and lift, loading & unloading, hire charges of machinery and equipments, transportation charges cost and conveyance of all materials, labour charges and all other incidental charges etc., complete as per standard technical detailed specification and design and directions of the engineer incharge of the work ( 1 ) 30.00 ( 2 ) 30.00 ( 3 ) 30.00 ( 4 ) 30.00 ( 5 ) 30.00 ( 6 ) 30.00 ( 7 ) 30.00 mtr 210 37 supplying and fixing surface / flush mounting unbreakable pvc modular box suitable for mounting modular switch plates with due groove cutting in brick / c.c wall, including necessary rawl plugs, machine / nf screws etc., complete. 6 way with all lead and lift, loading & unloading, hire charges of machinery and equipments, transportation charges cost and conveyance of all materials, labour charges and all other incidental charges etc., complete as per standard technical detailed specification and design and directions of the engineer incharge of the work ( 1 ) 2 ( 2 ) 2 ( 3 ) 2 ( 4 ) 2 ( 5 ) 2 ( 6 ) 2 ( 7 ) 2 each 14 38 supplying and fixing surface / flush mounting unbreakable pvc modular box suitable for mounting modular switch plates with due groove cutting in brick / c.c wall, including necessary rawl plugs, machine / nf screws etc., complete. 16 18 way with all lead and lift, loading & unloading, hire charges of machinery and equipments, transportation charges cost and conveyance of all materials, labour charges and all other incidental charges etc., complete as per standard technical detailed specification and design and directions of the engineer incharge of the work ( 1 ) 1 ( 2 ) 1 ( 3 ) 1 ( 4 ) 1 ( 5 ) 1 ( 6 ) 1 ( 7 ) 1 each 7 39 supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal / pvc box 6 way with all lead and lift, loading & unloading, hire charges of machinery and equipments, transportation charges cost and conveyance of all materials, labour charges and all other incidental charges etc., complete as per standard technical detailed specification and design and directions of the engineer incharge of the work ( 1 ) 2 ( 2 ) 2 ( 3 ) 2 ( 4 ) 2 ( 5 ) 2 ( 6 ) 2 ( 7 ) 2 each 14 40 supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal / pvc box 16 18 way with all lead and lift, loading & unloading, hire charges of machinery and equipments, transportation charges cost and conveyance of all materials, labour charges and all other incidental charges etc., complete as per standard technical detailed specification and design and directions of the engineer incharge of the work ( 1 ) 1 ( 2 ) 1 ( 3 ) 1 ( 4 ) 1 ( 5 ) 1 ( 6 ) 1 ( 7 ) 1 each 7 41 supplying and fixing of modular switch & connected accessories on existing modular switch plate as per is 3854 and is 1293. 6a one way switch with all lead and lift, loading & unloading, hire charges of machinery and equipments, transportation charges cost and conveyance of all materials, labour charges and all other incidental charges etc., complete as per standard technical detailed specification and design and directions of the engineer incharge of the work ( 1 ) 7 ( 2 ) 7 ( 3 ) 7 ( 4 ) 7 ( 5 ) 7 ( 6 ) 7 ( 7 ) 7 each 49 42 supplying and fixing of modular switch & connected accessories on existing modular switch plate as per is 3854 and is 1293. stepped fan regulator two module with all lead and lift, loading & unloading, hire charges of machinery and equipments, transportation charges cost and conveyance of all materials, labour charges and all other incidental charges etc., complete as per standard technical detailed specification and design and directions of the engineer incharge of the work ( 1 ) 3 ( 2 ) 3 ( 3 ) 3 ( 4 ) 3 ( 5 ) 3 ( 6 ) 3 ( 7 ) 3 each 21 43 supplying and fixing of modular switch & connected accessories on existing modular switch plate as per is 3854 and is 1293. 16a one way switch with all lead and lift, loading & unloading, hire charges of machinery and equipments, transportation charges cost and conveyance of all materials, labour charges and all other incidental charges etc., complete as per standard technical detailed specification and design and directions of the engineer incharge of the work ( 1 ) 2 ( 2 ) 2 ( 3 ) 2 ( 4 ) 2 ( 5 ) 2 ( 6 ) 2 ( 7 ) 2 each 14 44 supplying and fixing of modular switch & connected accessories on existing modular switch plate as per is 3854 and is 1293. 6 / 16a universal socket with all lead and lift, loading & unloading, hire charges of machinery and equipments, transportation charges cost and conveyance of all materials, labour charges and all other incidental charges etc., complete as per standard technical detailed specification and design and directions of the engineer incharge of the work ( 1 ) 1 ( 2 ) 1 ( 3 ) 1 ( 4 ) 1 ( 5 ) 1 ( 6 ) 1 ( 7 ) 1 each 7 45 supplying and fixing of modular switch & connected accessories on existing modular switch plate as per is 3854 and is 1293. rj45 / i.o outlet cat 6 with all lead and lift, loading & unloading, hire charges of machinery and equipments, transportation charges cost and conveyance of all materials, labour charges and all other incidental charges etc., complete as per standard technical detailed specification and design and directions of the engineer incharge of the work ( 1 ) 1 ( 2 ) 1 ( 3 ) 1 ( 4 ) 1 ( 5 ) 1 ( 6 ) 1 ( 7 ) 1 each 7 46 supplying and fixing regular mccb distribution panel confirming to is / iec 61439 3 and ik09 tested as per is / iec 62262 with minimum ip43 protection provided with polyurethane ( pur ) gasket, with suitable earthing system, on wall / wood board / flush mounting using required cl a , bolts, nuts, etc., with provision for fixing of suitable type capacity mccbs as an incomer for 3 phase double door with necessary bus bar completely wired to use on 440v 3phase 4 wire powder coated painting etc., complete with a provision for fixing of single / three phase suitable capacity mcbs as outgoings confirming to is / iec 60898 4 way with all lead and lift, loading & unloading, hire charges of machinery and equipments, transportation charges cost and conveyance of all materials, labour charges and all other incidental charges etc., complete as per standard technical detailed specification and design and directions of the engineer incharge of the work ( 1 ) 1 ( 2 ) 1 ( 3 ) 1 ( 4 ) 1 ( 5 ) 1 ( 6 ) 1 ( 7 ) 1 each 7 47 supplying, fixing and wiring residual current circuit breaker ( rccb ) 240 / 450v upto 300ma sensitivity on existing wood / panel board. 32 40a 2 pole. with all lead and lift, loading & unloading, hire charges of machinery and equipments, transportation charges cost and conveyance of all materials, labour charges and all other incidental charges etc., complete as per standard technical detailed specification and design and directions of the engineer incharge of the work ( 1 ) 1 ( 2 ) 1 ( 3 ) 1 ( 4 ) 1 ( 5 ) 1 ( 6 ) 1 ( 7 ) 1 each 7 48 supplying & fixing miniature circuit breakers on existing mcb distribution boards using necessary fixing materials and c type curve, indicator on / off, energy cross 3 with short circuit breaking capacity of 10k and complete wiring as required confirming to iec 60898. 6 32 a sp with all lead and lift, loading & unloading, hire charges of machinery and equipments, transportation charges cost and conveyance of all materials, labour charges and all other incidental charges etc., complete as per standard technical detailed specification and design and directions of the engineer incharge of the work ( 1 ) 1 ( 2 ) 1 ( 3 ) 1 ( 4 ) 1 ( 5 ) 1 ( 6 ) 1 ( 7 ) 1 each 7 49 supplying capacitor type ceiling fan complete with down rod blades, shackle, canopies etc, for operation on 230 v, 50 cycles. single phase ac supply conforming to iss 374 1979 and with double ball bearing system. 48 sweep ( 1200 mm ) regular model with all lead and lift, loading & unloading, hire charges of machinery and equipments, transportation charges cost and conveyance of all materials, labour charges and all other incidental charges etc., complete as per standard technical detailed specification and design and directions of the engineer incharge of the work ( 1 ) 2 ( 2 ) 2 ( 3 ) 2 ( 4 ) 2 ( 5 ) 2 ( 6 ) 2 ( 7 ) 2 each 14 50 fixing a ceiling / wall mounting fan of all capacities and all types, with necessary cla and s hook made out of 15mm dia ms rod, with 5 a. ceiling rose of approved quality with necessary length of 23 / 0.0076 inch pvc insulated twin twisted wire of approved quality, mounted on a suitable size wooden board and wired. with all lead and lift, loading & unloading, hire charges of machinery and equipments, transportation charges cost and conveyance of all materials, labour charges and all other incidental charges etc., complete as per standard technical detailed specification and design and directions of the engineer incharge of the work ( 1 ) 2 ( 2 ) 2 ( 3 ) 2 ( 4 ) 2 ( 5 ) 2 ( 6 ) 2 ( 7 ) 2 each 14 51 supplying of .....feet pvc batten with integrated led tube .... w with high quality diffuser with life of 25000 burning hours & 70% lumen maintenance with cri > 80. power input: 220 240v@ 50 / 60hz & power factor >0.9 along with ce approved. 2 years warranty against any manufacturing defect working under standard electrical condition. led light fitting 1 x 4 20 / 22 w with all lead and lift, loading & unloading, hire charges of machinery and equipments, transportation charges cost and conveyance of all materials, labour charges and all other incidental charges etc., complete as per standard technical detailed specification and design and directions of the engineer incharge of the work ( 1 ) 7 ( 2 ) 7 ( 3 ) 7 ( 4 ) 7 ( 5 ) 7 ( 6 ) 7 ( 7 ) 7 each 49 52 supplying, fixing, wiring, earth electrode for grounding conduits, i.c. cutouts and other equipments on the meter board using 40mm dia 2.90mm thick gi pipe 2.5 mtr long buried in a pit … the pit should be filled with equal proportion of salt and charcoal 150mm all round the pipe to complete depth. the connection from the pipe to the conduit etc., is to be established through gi wire of size as per isi specification 7.3.3. of is 732 using 12mm dia bolts, nuts, washers and check nuts etc., the pipe shall have 16 through holes of 12 mm diawith all lead and lift, loading & unloading, hire charges of machinery and equipments, transportation charges cost and conveyance of all materials, labour charges and all other incidental charges etc., complete as per standard technical detailed specification and design and directions of the engineer incharge of the work ( 1 ) 1 ( 2 ) 1 ( 3 ) 1 ( 4 ) 1 ( 5 ) 1 ( 6 ) 1 ( 7 ) 1 no 7 53 supplying, fixing and wiring electronic trivector meter ( etv ) 5 to 20a single phase class 1 accuracy with temper proof energy meter. with all lead and lift, loading & unloading, hire charges of machinery and equipments, transportation charges cost and conveyance of all materials, labour charges and all other incidental charges etc., complete as per standard technical detailed specification and design and directions of the engineer incharge of the work ( 1 ) 1 ( 2 ) 1 ( 3 ) 1 ( 4 ) 1 ( 5 ) 1 ( 6 ) 1 ( 7 ) 1 each 7 54 bescom deposite including supervision and agreement charges ( 1 ) 1 ( 2 ) 1 ( 3 ) 1 ( 4 ) 1 ( 5 ) 1 ( 6 ) 1 ( 7 ) 1...

South Western Railway - Karnataka

34404277 auction sale of [ pl no. 98090800 ] scrap / cond / released / rusted m.s bazar scrap such as disintegrated thorough rust corrugated sheets, pots, springs cutting hup iron, gurrah, mortar pans, buckets, oil tanks, coal tubes, un sound / corroded paint drums / tar / oil / grease barrels containing with / without paint / oil / tar, water strainer, bail putty, corroded commode chutes, name dimply board punjas, dampers, destination board, tins, sheets, packing sheets, corroded battery boxes / sheets / released u type sheets of different sizes and lengths, corroded dust shield springs, fencing wire, berth ladders, dampers, compressed empty paint drums, oil filters, packing bands, rusted gi wire knitting, iron mesh, corroded zinc sheet / fabricated materials, corroded grs boxes, gi / ms wire / rope , alphabetic location boards, fully corroded tl fan / tube fittings, panel boards, broken fire extinguishers, geyser bodies and other items coming under bazaar scrap on as is where is condition available under the custody of cdms / 08 ward / ap.note: 1.pick and choose of the material are not allowed. loading to be started from one end and to be ended on other end only. ( pressing permitted ) special conditions: during delivery, selection, sorting, rejection of part or partial lot will not be entertained. picking, disturbing of other nearby lots, undefined materials near lot or under lot formation materials will not be entertained. purchaser may survey materials before bidding into auction, after successful bid further queries or objection will not be entertained. ( loc: bin no 0134 and 0136 at scrap yard...

Karnataka Power Corporation Limited - Karnataka

34277535 consolidated procurement of cable jointing and wiring materials for all projects of kpcl , power cable vlo 0.75 sq mm, 07cx2.5 sqmm gland 1.1kv, 12c x 2.5 sq. mm gland, gland for 5cx2.5sqmm cable, 1000sqmm aluminium lug, power cable glant 1c 500sqmm, 5 amp socket, 5 amps switches, jumper cables, indoor 3x 400 sqmm 11kv termin, inst cbl cop 16px0.5 sqmm, cop inst arm cble 4cx.05m, cop inst arm cbl 12px.5mm, cop inst arm cbl 16cx.5mm, 8 swg gi wire, 8 swg gi wire, instru.cable 12pair x 0.5, heatshrink tube 2, heatshrink tube 1 / 16, heatshrink tube 1 / 8, heatshrink tube 1 / 4, heatshrink tube 3 / 8, heatshrink tube 1 / 2, heatshrink tube 1, heat shrink sleeve 2mm specification as per section iii tender document, solvent cement, xlpa 630sq.mm endtermnl kit id, 4c x 2.5sqmm copper mult cable, 4c x 2.5sqmm copper mult cable, m.strand copper wire 2.5sq.mm, multi strand copper wire 4.sq., 3cx1.5 sqmm cu.multi stand cab, 4cx2.5sqmm cu. multi stand cab, 2.5 sqmm multi std pvc cable, 2.5sqmm multi cable, 2.5sqmm multi cable, 2.5sqmm multi cable, calling bells, cable tie 150 mm, cable tie 200 mm, releasabl cable tie 300x7.6 mm, cable tie 300x7.6 mm, cable tie 600 x 9 mm, cable tie 200 x 4.8 mm, cable tie 150 x 4.6 mm, marker cable tie 100x2.5mm...

Directorate Of Municipal Administration - Karnataka

34169414 annual supply of water supply materials to tmc, lakshmeshwar , 1 pvc collar ( 6kg ) , 1 pvc tee. modlded ) , 1 1 / 2 a pvc ewlbo, 1 1 / 4 a pvc ewlbo, 1 x 2âpvc reducer isi, 1 to 2 hp single phase submerciable power pump, 1 a pvc pipe ( isi mark ) 6 kg, 1 gi cock isi, 1 pvc collar ( molded ) , 1 pvc tee. modlded ) , 1 x 1â¼ apvc reduser isi, 1 x 1â¼ reducer elbow pvc isi, 1pvc adapted ( male ) , 1.5 hp single phase stater set isi mark, 1 / 2 pvc pipe ( isi mark ) 6 kg, 1 / 2 x 3 / 4 pvc reducer, 1 / 2 x 3 / 4âpvc end cap isi, 1 / 2 x 90 pvc bend, 1 / 2 a pvc ewlbo, 1 / 2 g i union isi, 1 / 2 gi cock isi, 1 / 2 pvc collar ( molded ) , 1 / 2 pvc elwbo 6kg isi, 1 / 2 pvc tee. modlded ) , 1 / 2 steel cock, 1 / 2 x 2â½ pvc saddle isi, 1 / 2pvc adapted ( male ) , 1 / 2pvc adapted ( male ) , 1 / 2x2 1 / 2 pvc saddle isi, 1 / 2x3 pvc saddle isi, 1 / 2x4 pvc saddle isi, 1 / 2x6 pvc saddle isi, 1 / 2 a pvc pipe ( isi mark ) 6 kg, 10 mm aluminium wire, 10 to 14hp 3phase monoblock pump set 12 stage, 100 amps load limiter, 100mm ci valve kartar isi, 10hp 3phase submerciable power pump 12 stage suguna / vguard, 110mm leakage coupler pvc, 110mm pvc bend 6kg, 12 no gi wire isi mark, 12x150 m.m full faded nut bolt, 14hp 3phase submerciable power pump 12 stage suguna / vguard, 150 mm ci valve kartar isi, 16 no gi wire isi mark, 16a x 415 v.i.c.t.p switch unit, 180mm pvc elbow 6kg, 180mm pvc reducer 6kg, 180mm pvc collar, 180mm pvc end cap, 180mm pvc tee 6kg, 180mm sleve valve isi mark, 1â¼ apvc adapter ( 4kg ) , 1â¼ g i union isi, 1â¼ third adapter apvc isi, 1â¼ x 1â½ apvc reduser isi, 1â¼ x 1â½ reducer elbow pvc isi, 1â½ gi union isi, 1â½ third adapter apvc isi, 1â½ x 2 apvc reduser isi, 1â½ x 2 pvc reducer elbow isi, 2 1 / 2 x 2 pvc reducer isi, 2 1 / 2 x 3 pvc reducer isi, 2 1 / 2 gm gate valve, 2 hp single phase stater set isi mark, 2 1 / 2 a pvc pipe ( isi mark ) 6 kg, 2 a pvc pipe ( isi mark ) 6 kg, 2 apvc adapter ( 4kg ) , 2 apvc end cap, 2 g.i plug ( h ) , 2 g.i unian ( h ) , 2 gi pipe isi, 2 gi plastic valve, 2 gm gate valve, 2 pvc bend isi mark, 2 pvc collar ( molded ) , 2 pvc elwbo 6kg isi, 2 pvc end cap isi, 2 pvc leakage coupler finolex, 2 pvc pipe ( isi mark ) 6 kg, 2 pvc tee. modlded ) , 2 x 2â½ pvc tellpice isi, 2pvc adapted ( male ) , 2 gi bend & culping ( h ) , 2 gi pipe with tata collar isi, 2.5 finolex cable wire, 200 mm ci valve kartar isi, 200mm pvc elbow 6kg, 200mm leakage coupler pvc, 200mm pvc bend 6kg, 200mm pvc collar, 200mm pvc pipe ( isi mark ) 6kg, 200mm pvc reducer 6kg, 20mm*12 inch gi nipple, 20mm*15mm nut bolt, 20mm*24 inch gi nipple, 20mm*36 inch gi nipple, 20mm*6 inch gi nipple, 21 to 32 ltlk stater realy, 240mm legs isi mark, 2â½ ci valve isi, 2â½ x 3 pvc tellpice isi, 3 hp single phase submerciable power pump, 3 a pvc pipe ( isi mark ) 6 kg, 3 ci valve isi, 3 ci kartar sluice valve isi, 3 gm gate valve isi, 3 m s flange isi, 3 pvc adapter ( 6kg ) , 3 pvc bend isi mark, 3 pvc collar ( molded ) , 3 pvc elwbo 6kg isi, 3 pvc end cap isi, 3 pvc leakage coupler finolex, 3 pvc pipe ( isi mark ) 6 kg, 3 pvc tee. modlded ) , 3 x 4 pvc reducer elbow isi, 3 x 4 reducer collar isi, 3 x 4 tellapice pvc isi, 3pvc adapted ( male ) , 3.5 x 4 x 1.5 ms penal board box, 3 / 20 copper wire, 3 / 4 gi pipe isi, 3 / 4 apvc pipe ( 6kg ) isi finolex, 3 / 4 g i union isi, 3 / 4 gi cock isi, 3 / 4 pvc bend isi mark, 3 / 4 pvc collar ( molded ) , 3 / 4 pvc pipe ( isi mark ) 10 kg, 3 / 4 pvc pipe ( isi mark ) 6 kg, 3 / 4 pvc tee. modlded ) , 3 / 4âpvc end cap isi, 300mm legs isi mark, 32 a x 415 v.i.c.t.p switch unit, 4 pvc adapted, 4 pvc elbow, 4 a pvc bend, 4 ci valve isi, 4 ci kartar sluice valve isi, 4 leakage coupler pvc, 4 m s flange isi, 4 pvc adapter ( 6kg ) , 4 pvc bend isi mark, 4 pvc collar ( molded ) , 4 pvc elwbo 6kg isi, 4 pvc end cap ( 6kg ) finolexs, 4 pvc pipe ( isi mark ) 6 kg, 4mm finolex cable wire, 5 hp single phase submerciable power pump 12 stage sunaga / vguard, 5 x 4 pvc reducer isi, 5 x 6 reducer collar isi, 6 hp 10stage sub mercible motor pump set, 6 x 4 pvc reducer isi, 6 to 7.5 hp single phase stater set isi mark, 6 pvc adapted, 6 pvc elbow, 6 pvc end cap ( 6kg ) , 6 a pvc bend, 6 ci valve isi, 6 ci kartar sluice valve isi, 6 leakage coupler pvc, 6 m s flange isi, 6 pvc adapter ( 6kg ) , 6 pvc bend isi mark, 6 pvc leakage coupler finolex, 6 pvc pipe ( isi mark ) 6 kg, 6 x 6 pvc reducer elbow isi, 6 x 6 tellapice pvc isi, 6a switch socket, indicator and bell bush, 7.5 hp 3phase submerciable power pump 12 stage, 7 / 20 copper wire, 8 pvc end cap ( 6kg ) , 8 pvc end cap isi, 8 pvc leakage coupler finolex, 8 pvc pipe ( isi mark ) 6 kg, 8 pvc tee. modlded ) , 8 x 6 pvc reducer ( 6 kg ) , 80mm ci valve kartar isi, 900 x 750 m.s cutting panel board box, 900 x 750 m.s panel board box, 13 21 ltlk stater rile, 13 21 ltlk starter relay, 63 amps load limiter, 63 amps t p set, 7.5 hp preventer, 8 to 15 hp preventer, aluminum service wire bundle, amps and volt meter set, contractor set ltlk, ltlk 13 to 21 stater rile, ltlk 6 to 10 stater rile, ltlk 9 to 14 stater rile, ltlk contractor, solvent cement., starter point kit, bearing grease, rubber packing...

South Western Railway - Karnataka

34147860 supply of gi wire 8 swg coated with zincgi wire 8 swg coated with zinc, gi wire 8 swg coated with zinc confirming to grade zn 98 specified in is 209.1966. the zinc coating shall be uniform, adherent, reasonable smooth and free from imperfections as per is 280.2006, => limited...

D. Devaraj URS Backward Classes Development Corporation - Karnataka

34047417 eoi for empanelment of manufacturers of submersible pumpsets for supply, installation and electrification ( energization ) of irrigation submersible pumpset along with its accessories suitable for 165mm dia borewells under ganga kalyana scheme for the year 2020 21, 2021 22 and 2022 23.in the development corporations coming under backward classes welfare department. , submersible pump sets 5 hp 10 stage, submersible pump sets 5 hp 12 stage, submersible pump sets 7.5 hp 12 stage, submersible pump sets 7.5 hp 15 stage, submersible pump sets 7.5 hp 20 stage, submersible pump sets 10 hp 20 stage, submersible pump sets 10 hp 30 stage, submersible pump sets 12.5 hp 20 stage, submersible pump sets 12.5 hp 30 stage, submersible pump sets 15 hp 30 stage, submersible pump sets 15 hp 35 stage, submersible pump sets 17.5 hp 26 stage, submersible pump sets 17.5 hp 35 stage, submersible pump sets 20 hp 30 stage, submersible pump sets 20 hp 40 stage, providing, gi pipes conforming to is 1239:1990 with latest amendments complete with cuts and threads wherever necessary, including testing for water tightness, with all lead and commissioning. ( contractor will make his own arrangements for procuring water for testing ) for medium duty gi pipe class ‘b’ medium duty size 50 mm., providing mild steel ( galvanized ) 50 mm dia gi collar confirming to is 1239 ii, 1991 with latest amendments if any. 50mm, supply and delivery at site 50mm ( 2” ) dia heavy duty unplasticized upvc column pipes with heavy duty collars, rubber profile ring, vibration control profile ring, freezing and turbulence free leak proof epdm ring with isi mark with its latest amendments, supply and delivery at site 50mm ( 2” ) dia heavy duty gi adopter set complete suitable for upvc column pipes for submersible pumpsets., supply and delivery at site brand new best make pvc insulated cable of flat 3 core ( sheathed ) of nominal cross sectional area as per is 694 2010 with isi mark and as per its latest amendments 1x3x2.5 sqmm, supply and delivery at site brand new best make pvc insulated cable of flat 3 core ( sheathed ) of nominal cross sectional area as per is 694 2010 with isi mark and as per its latest amendments 1x3x4 sqmm, supply and delivery at site brand new best make pvc insulated cable of flat 3 core ( sheathed ) of nominal cross sectional area as per is 694 2010 with isi mark and as per its latest amendments 1x3x6 sqmm, supply and delivery at site of brand new best make gate valve as per is 778 / 1984 with isi mark and as per its latest amendments size 50 mm, supply and delivery at site of brand new best make non return valve as per is 778 / 1984 with isi mark and as per its latest amendments size 50 mm, supply and delivery at site mild steel ( galvanized ) gi bend confirming to is 1239 ii, 1991 with latest amendments if any. size 50 mm, supply and delivery at site mild steel ( galvanized ) gi hexagonal nipple confirming to is 1239 ii, 1991 with latest amendments if any. size 50 mm, supply, installing, testing and commissioning common control panel consisting of the following incoming:1 no set of phase indicating lamps with sfu of suitable rating 1 no, analog ammeter, 1 no analog voltmeter 1ni with phase selector switch, isolating switch outgoing for main electrical pump: 1 no. mcb 1 no. dol of s / d starter suitable for respective hp 1 no. electrical protection like single phase preventer, under voltage over volage, under current over current & dry run protection suitable for the pump described above 1 no for outdoor type upto 6 hp pumps, supply, installing, testing and commissioning common control panel consisting of the following incoming:1 no set of phase indicating lamps with sfu of suitable rating 1 no, analog ammeter, 1 no analog voltmeter 1ni with phase selector switch, isolating switch outgoing for main electrical pump: 1 no. mcb 1 no. dol of s / d starter suitable for respective hp 1 no. electrical protection like single phase preventer, under voltage over volage, under current over current & dry run protection suitable for the pump described above 1 no for outdoor type 6 to 15 hp pumps, supply, installing, testing and commissioning common control panel consisting of the following incoming:1 no set of phase indicating lamps with sfu of suitable rating 1 no, analog ammeter, 1 no analog voltmeter 1ni with phase selector switch, isolating switch outgoing for main electrical pump: 1 no. mcb 1 no. dol of s / d starter suitable for respective hp 1 no. electrical protection like single phase preventer, under voltage over volage, under current over current & dry run protection suitable for the pump described above 1 no for outdoor type 15 to 20 hp pumps, supply and delivery at site best indigenous brand new power capacitor as per is 2834 / 1986 with latest amendments with kptcl authorities and erection, electrification and commissioning of the same at the location of respective pump sets. – kvar, supply and delivery at site delivery of best indigenous brand new mcb ( miniature circuit breakers ) of required capacity as per is 88228 / 1978 and its latest amendments and with isi mark of 6 / 10 / 16 / 20 / 25 / 40 amps with scalable box ( per 3 poles ) , providing, supplying and fixing suitable for 1.1 kv class ug cable filled with necessary bitumen / insulating compound complete with terminals, clamps, bolts, nuts and washers etc. with necessary materials and labour tools and equipment’s as per instructions of engineer incharge of work. –3.5 x 10 sq mm, providing, supplying and fixing suitable for 1.1 kv class ug cable filled with necessary bitumen / insulating compound complete with terminals, clamps, bolts, nuts and washers etc. with necessary materials and labour tools and equipment’s as per instructions of engineer incharge of work. – 3.5 x 25 sq mm, providing, laying and fixing gi pipes conforming to is 1239:1990 with latest amendments complete with gi fittings ( excluding the cost of fittings ) with cuts and threads wherever necessary, including testing for water tightness, with all lead and commissioning. ( contractor will make his own arrangements for procuring water for testing ) light duty 40mm ‘a’ class for earthing., labour charges for erection, electrification and commissioning of pump sets, including aligning and balancing of all items including supply and erection of two pair of supporting clamps, bore well caps, cable clips and water tight gland cable protectors, bolts, nuts, valve and gauges, tools and equipment’s etc., involved in the job as per specifications, with necessary tests as per specifications, with testing of as per instructions of engineer in charge of work., labour charges for erection of outdoor type panel board and meter board units with all necessary materials and labour, tools and equipment’s including providing cement concrete foundation bed etc., complete as per specification, with testing of as per instructions of engineer in charge of work., providing main connection from pole pvc insulated sheathed steel wire cable in new trench as per is 1554 / 1988 with latest amendments with isi mark from kptcl pole to meter board unit., digging of trench of 0.6 mtr deep x 0.50 mtr wide refilling the trench to the required ground level and consolidating, etc. complete as per instructions of engineer / assigned officers incharge of work in soil ( ordinary ) , providing, supplying and fixing lt cast iron pot heads suitable for 1.1 kv class ug cable filled with necessary bitumen / insulating compound complete with terminals clamps, bolts, nuts and washers, etc. with all necessary materials and labour tools and equipment’s as per specifications, with testing of as per instructions of engineer / assigned officers incharge of work. 3.5x10 sqmm, providing, supplying and fixing lt cast iron pot heads suitable for 1.1 kv class ug cable filled with necessary bitumen / insulating compound complete with terminals clamps, bolts, nuts and washers, etc. with all necessary materials and labour tools and equipment’s as per specifications, with testing of as per instructions of engineer / assigned officers incharge of work. 3.5 x 25 sqmm, supporting clamps ( two pairs ) , pvc cable locking strips ( 2 nos per length ) heavy ( for installation of 152 mtrs & above ) each pair weighing not less than 4000 grms of 350mmx60mmx10mm size., borewell cap ( including bolts and nuts ) weighing not less than 800 gms., earthing: supplying and fixing and wiring earth electrode for grounding circuits ic cutouts and other equipment’s on the meter board in the pit. the pits should be filled up with equal proportion of salt and charcoal 150mm around the pipe to complete depth. the connection from the pipe to the conduits etc. is to established through gi wire of sizes as per clause 7.3.3 of is 732 using 12mm bolts, nuts, washers and check nuts, the pipe shall have 16 through holes of 12mm dia....

South Western Railway - Karnataka

34008487 supply of gi wire 8 swg coated with zincgi wire 8 swg coated with zinc, gi wire 8 swg coated with zinc confirming to grade zn 98 specified in is 209.1966. the zinc coating shall be uniform, adherent, reasonable smooth and free from imperfections as per is 280.2006, => limited...

Council Of Scientific And Industrial Research - Karnataka

33866732 quotation for electrical materials quotation for electrical materials , 2 modular pvc box with plate make: roma , 1 modular pvc box with plate make: roma , 4 modular pvc box with plate make: roma , 6 modular pvc box with plate make: roma , 8 modular pvc box with plate make roma , 18 modular pvc box with plate make:roma , 12 modular pvc box with plate make: roma , 16 modular pvc box with plate make roma , olrtype: 6 12a ldr 21 make: l & t , mk1 thermal overload relay 11 18a make: l & t , water proof double ended tape make: reputed , cfl 15watt, 230vac tread type make: philips / cg / bajaj , fan regulator two modular step type. make: roma , sp modular switches 10a 230vac make: roma , sp modular switches 20a 230vac make: roma , modular socket 10a 230vac make: roma , modular socket 20a 230vac make: roma , sp switch 6a 230vac make: lisha / anchor , sp switch 16a 230vac make: lisha / anchor , socket 6a 5 pin 230vac make: lisha / anchor , socket 6 / 16a 6 pin 230vac make: lisha / anchor , single modular dummy switch plugs make: roma , wooden gattas 100nos pack make:standard , pvc round blocks make : chowdary , pvc junction covering over size plate small make: reputed , pvc junction covering plate big make: reputed , rocker switch dp 20a 230vac make: reputed , nylon cable ties 100mm 100nos pack make: reputed , nylon cable ties 150mm 100nos pack make: reputed , nylon cable ties 200mm 100nos pack make: reputed , nylon cable ties 250mm 100nos pack make: reputed , nylon cable ties 300mm 100nos pack make: reputed , nylon cable tie base make: reputed , cfl 18w, 230vacpin type make: philips / crompton , wooden screw 1 / 2” ( 35 / 8mm ) make: reputed , wooden screw 3 / 4” ( 50 / 8mm ) make: reputed , wooden screw 1” make: reputed , wooden screw 1.5” make: reputed , wooden screw 2” make: reputed , 2x28w t5 electronics choke make: philips , 40 fluorescent lamp side holder pin type make : reputed , 40w fluorescent lamp starter drum type make: reputed , 15a combined switch and socket make: lisha / anchor , 15 / 6a combined switch and socket make: lisha / anchor , 40w copper wondedchoke make: crompton / philips , u axe frame blades 13mm ( 144 pack ) make: reputed , 40w fluorescent lamp make:philips / cg / bajaj , 20w 2 fluroscent tube make:philips / cg / bajaj , 55w 5ft fluoroscent lamp make:philips / bajaj , 45w led out door type fitting for street light make:philips / cg / bajaj , 60w led out door type fitting for street light make:philips / cg / bajaj , 90 w led out door type fitting for street light make:philips / cg / bajaj , t5, 28w tubes make:philips / cg / bajaj , t5, 14w tubes make:philips / cg / bajaj , dlp truncking 50x80 mm, 2meter long make:legrand , dlp trunching 32x32 mm, 2meter long make: legrand , 19mm gi sadle black color make: reputed , 25mm gi sadle black color make: reputed , earth strip bar sadle with base 19mm make: reputed , earth strip bar sadle with base 25mm make: reputed , 32mm pvc flexible conduit grey make: reputed , 25mm pvc flexible conduit grey make: reputed , 19 mm pvc flexible conduit grey make: reputed , 32mm pvc flexible conduitwith re inforced gi wire make: reputed , 25mm pvc flexible conduitwith re inforced gi wire make: reputed , 19 mm pvc flexible conduitwith re inforced gi wire make: reputed , fan capacitor 1.5 mfd, 440v make: reputed , fan capacitor 2 .5mfd, 440v make: reputed , fan capacitor 3.15 mfd, 440v make: reputed , fan capacitor 5 mfd, 440v make: reputed , celing fan 80w 1200 sweep make: usha / orient / cg , pvc bend 1 black make: reputed , pvc bend 3 / 4 black make: reputed , pvc color1 black make: reputed , pvc color 3 / 4 black make: reputed , pvc elbow1 black make: reputed , pvc elbow3 / 4 black make: reputed , pvc pipe 1 black make: reputed , pvc pipe 3 / 4 black make: reputed , pvc junction box 1 way 1 black make: reputed , pvc junction box 2 way 1 black make: reputed , pvc junction box 3 way 1 black make: reputed , pvc junction box 4 way 1 black make: reputed , pvc junction box 1 way 3 / 4 black make: reputed , pvc junction box 2 way 3 / 4 black make: reputed , pvc junction box 3 way 3 / 4 black make: reputed , pvc junction box 4 way 3 / 4 black make: reputed , insulation tape adhesive 8m black make: anchor , insulation tape adhesive 8m red make: anchor , insulation tape adhesive 8m yellow make: anchor , insulation tape adhesive 8m blue make: anchor , insulation tape adhesive 8m green make: anchor , incandiscent lamp 230vac 60w make: philips , incandiscent lamp 230vac 100w make: philips , pendent holder make: lisha , fork type lugs 1.5sq mm make: dowells / braco / multi / pomat , fork type lugs 2.5sq mm make:dowells / braco / multi / pomat , ring type lugs 1.5sqmm make:dowells / braco / multi / pomat , ring type lugs 2.5sqmm make:dowells / braco / multi / pomat , ring type lugs 4 sqmm make:dowells / braco / multi / pomat , ring type lugs 6 sqmm make:dowells / braco / multi / pomat , ring type lugs 10 sqmm make:dowells / braco / multi / pomat , pin type lugs 2.5 sqmm make:dowells / braco / multi / pomat , pin type lugs 4 sqmm make:dowells / braco / multi / pomat , pin type lugs 6 sqmm make:dowells / braco / multi / pomat , pin type lugs 10sqmm make:dowells / braco / multi / pomat , pin type lugs 16 sqmm make:dowells / braco / multi / pomat , nylon cable glands pg 19 make:dowells / braco / multi / pomat , nylon cable glands pg 22 make:dowells / braco / multi / pomat , nylon cable glands pg 28 make:dowells / braco / multi / pomat , nylon cable glands pg 32 make:dowells / braco / multi / pomat , nylon cable glands pg 35 make:dowells / braco / multi / pomat , led batten type 20w ( 4 ) fittings make:philips / cg / bajaj , 1.5sqmm multistrand 1.1kv grade copper wire red 100m coil make: finolex / policab , 1.5sqmm multistrand 1.1kv grade copper wire black 100m coil make: finolex / policab , 1.5sqmm multistrand 1.1kv grade copper wire yellow 100m coil make: finolex / policab , 1.5sqmm multistrand 1.1kv grade copper wire blue 100m coil make: finolex / policab , 3 part celing rose 230vac make: reputed , 28 w, 240v, twin led fitting complete set with suitable driver with inbuilt protection, white colormake:bajaj type:bctbls 36 zt wh or equivalent make: philips / cg / wipro , sp mcbs c curve with 10ka breaking capacity of following rating , 6a 230vac make: abb / siemens , 10a 230vac make: abb / siemens , 16a 230vac make: abb / siemens , 20a 230vac make: abb / siemens , 32a 230vac make: abb / siemens , dp mcbs c curve with 10ka breaking capacity of following rating , 6a 230vac make: abb / siemens , 10a 230vac make: abb / siemens , 16a 230vac make: abb / siemens , 20a 230vac make: abb / siemens , 32a 230vac make: abb / siemens , tp mcbs c curve with 25ka breaking capacity of following rating , 6a 230vac make: abb / siemens , 10a 230vac make: abb / siemens , 16a 230vac make: abb / siemens , 20a 230vac make: abb / siemens , 32a 230vac make: abb / siemens , 4p mcbs c curve with 25ka breaking capacity of following rating , 6a 415vac make: abb / siemens , 10a 230vac make: abb / siemens , 16a 230vac make: abb / siemens , 20a 230vac make: abb / siemens , 32a 230vac make: abb / siemens , 40a 230vac make: abb / siemens , 63a 230vac make: abb / siemens , 100a 230vac make: abb / siemens , 125a 230vac make: abb / siemens , pvc dp mcb enclosure polycarbonate make: legrand / havells / indoasian , pvc 4p mcb enclouser polycarbonate make: legrand / havells / indoasian , exhaust fan metal body 300x300mm make: usha / orient / crompton , exhaust fan metal body 250x250mm make: usha / orient / crompton , exhaust fan metal body 200x200mm make: usha / orient / crompton , exhaust fan metal body 225x225mm make: usha / orient / crompton , 32 amps, 415 volts, tpn industrial type socket outlet, with 4 pole and earth, metal enclosed plug top along with 30 amps c curve, tp mcb, in sheet steel enclosure on surface or in recess, with chained metal cover for the socket outlet make: legrand / abb / schneider , 63amps, 415 volts, tpn industrial type socket outlet, with 4 pole and earth, metal enclosed plug top along with 30 amps c curve, tp mcb, in sheet steel enclosure on surface or in recess, with chained metal cover for the socket outlet make: legrand / abb / schneider , 4 way, double door vertical type, tpn, sheet steel, mcb distribution board, 415 volts, on surface complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted. make: legrand / abb / schneider , 8 way, double door vertical type, tpn, sheet steel, mcb distribution board, 415 volts, on surface complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted. make: legrand / abb / schneider , 12 way, double door vertical type, tpn, sheet steel, mcb distribution board, 415 volts, on surface complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted. make: legrand / abb / schneider , bajaj edge 100w led street light lamp drivers cat no:bgd 36240 5y make:bajaj / crompton , bajaj edge 60w led street light lamp drivers cat no:bgd 36195 5y make:bajaj / crompton , bajaj edge 45w led street light lamp drivers cat no:bgd 36195 5y make:bajaj / crompton , crc 2 26 , electro cleaner , 500ml aerosol can make: crc , compact led panel 12w square 4x4inch led fitting ( surface mount ) make: cg / bajaj / philips , 1200 mm bldc motor with remote 3 blade ceiling fan 230vac. make: crompton / atomberg , 9w 230v led bulb screew type make: crompton / philips , double modular step control fan regulator make: roma , singlemodular step control fan regulator make: roma , electronic fan regulator flush type ( switch type 1 module ) 230vac make: anchor , electronic fan regulator flush type ( socket type 2 module ) 230vac make: anchor , modular dp mcb 32a make: roma , modular sp mcb 6a make: roma , modular sp mcb 10a make: roma , single compressedbrassmetal galnd of 19mm size make: dowells / braco / multi , single compressedbrassmetal galnd of 22mm size , single compressedbrassmetal galnd of 25mm size make: dowells / braco / multi , single compressedbrassmetal galnd of 28mm size make: dowells / braco / multi , 3cx2.5sqmm copper flexible cable 1.1kv grade make: polycab / finolex / power , 4cx2.5sqmm copper flexible cable 1.1kv grade make: polycab / finolex / power , 3cx1.5sqmm copper flexible cable 1.1kv grade make: polycab / finolex / power , 2cx1.5sqmm copper flexible cable 1.1kv grade make: polycab / finolex / power , 4cx4sqmmcopperflexiblecable1.1kv grade make: polycab / finolex / power , 25mm pvc casing and capping make:modi , pvc over size cover make: reputed , angular holder make: lisha , 20mm ms heavy duty saddles make: bharath / national , 25mm ms heavy duty saddles make: bharath / national , pvc bend 1 1 / 4 black ( 32mm ) make: reputed , 20mm pvc conduit pipe having 2mm thickness heavy duty make: reputed , 25mm dia x 350mm long hamering hole bit make: bosch , 6mm x 160mm concrete drilling bit make: bosch , 8mm x 160mm concrete drilling bit make: bosch , 8mm x 110mm concrete drilling bit make: bosch , 18w / 20w, t5 retro led tubes of length 1200mm high quality aluminium houong and pc diffuser for led liner lamp make: philips / cg / jaguar , 18w / 23w, t5 retro led tubes of length 1200mm high quality aluminium houong and pc diffuser for led liner lamp make: philips / cg / jaguar , 15w round led recess mounting type down light with aluminium die cast housing make: philips / cg / jaguar , 30w led lensed type street light pressure die cast aluminium housing make: philips / cg / jaguar , 45w led lensed type street light pressure die cast aluminium housing make: philips / cg / jaguar , 60w led lensed type street light pressure die cast aluminium housing make: philips / cg / jaguar , 50 / 60w led flood light lened type ip66 aluminium pressure die cast cover toughened glass make: philips / cg / jaguar , sub total: , less: discount ( if any ) ...

Karnataka Power Corporation Limited - Karnataka

33642137 procurement of weld mesh and barbed gi wire scope of supply: weld mesh and barbed gi wire shall be supplied as per the specification indicated to ytps stores within the delivery period to be stipulated in the order. procurement of weld mesh and barbed gi wire , weld mesh size 1x 1, weld mesh 1 sq x 4 mm, g.i.barbed wire 12 swg...

South Western Railway - Karnataka

33524291 auction sale of [ pl no. 98090800 scrap / cond / released / rusted m.s bazar scrap such as disintegrated thorough rust corrugated sheets, pots, springs cutting hup iron, gurrah, mortar pans, buckets, oil tanks, coal tubes, dpt kit, un sound / corroded paint drums / tar / oil / grease barrels containing with / without paint / oil / tar, water strainer, bail putty, corroded commode chutes, name dimply board punjas, dampers, destination board, tins, sheets, packing sheets, corroded battery boxes / sheets / released u type sheets of different sizes and lengths, corroded dust shield springs, fencing wire, berth ladders, dampers, compressed empty paint drums, oil filters, packing bands, rusted gi wire knitting, iron mesh, corroded zinc sheet / fabricated materials, corroded grs boxes, gi / ms wire / rope , alphabetic location boards, fully corroded tl fan / tube fittings, panel boards, broken fire extinguishers, geyser bodies and other items coming under bazaar scrap on as is where condition available under the custody of dms 08 ward ap.note: pick and choose of the material are not allowed loading to be started from one end and to be ended on other end only. ( pressing permitted ) ( loc: bin no 0134 and 0136 at scrap yard ) special conditions: during delivery, selection, sorting, rejection of part or partial lot will not be entertained. picking, disturbing of other nearby lots, undefined materials near lot or under lot formation materials will not be entertained. purchaser may survey materials before bidding into auction, after successful bid further queries or objection will not be entertained....

Karnataka Power Corporation Limited - Karnataka

33500591 consolidated procurement of cable jointing and wiring materials for all projects of kpcl consolidated procurement of cable jointing and wiring materials for all projects of kpcl , power cable vlo 0.75 sq mm, 07cx2.5 sqmm gland 1.1kv, 12c x 2.5 sq. mm gland, gland for 5cx2.5sqmm cable, 1000sqmm aluminium lug, power cable glant 1c 500sqmm, 5 amp socket, 5 amps switches, jumper cables, indoor 3x 400 sqmm 11kv termin, inst cbl cop 16px0.5 sqmm, cop inst arm cble 4cx.05m, cop inst arm cbl 12px.5mm, cop inst arm cbl 16cx.5mm, 8 swg gi wire, 8 swg gi wire, instru.cable 12pair x 0.5, heatshrink tube 2, heatshrink tube 1 / 16, heatshrink tube 1 / 8, heatshrink tube 1 / 4, heatshrink tube 3 / 8, heatshrink tube 1 / 2, heatshrink tube 1, heat shrink sleeve 2mm specification as per section iii tender document, solvent cement, xlpa 630sq.mm endtermnl kit id, 4c x 2.5sqmm copper mult cable, 4c x 2.5sqmm copper mult cable, m.strand copper wire 2.5sq.mm, multi strand copper wire 4.sq., 3cx1.5 sqmm cu.multi stand cab, 4cx2.5sqmm cu. multi stand cab, 2.5 sqmm multi std pvc cable, 2.5sqmm multi cable, 2.5sqmm multi cable, 2.5sqmm multi cable, calling bells, cable tie 150 mm, cable tie 200 mm, releasabl cable tie 300x7.6 mm, cable tie 300x7.6 mm, cable tie 600 x 9 mm, cable tie 200 x 4.8 mm, cable tie 150 x 4.6 mm, marker cable tie 100x2.5mm...

Directorate Of Municipal Administration - Karnataka

33442841 providing and fixing safety equipments to high masks=1 digging of trench of 0.6m deep x 0.50 mtr wide refilling the trench to the required ground level and consolidating etc., complete. ( as per civil sr ksrb i 2, p 7 ) asphalt cutting 2 supply and laying double walled corrugated ( dwc ) hdpe pipe including all necessary connectingsockets / couplings / tees / bends / end caps of same materials in existing trench as per is 14930 part ii suitable for drawing underground cables.50mm od / 38mm id 3 supplying of 1.1 kv lt ug cable having aluminum conductor pvc insulated, extruded inner sheathed, galvanized, steel strip ( except 2cx10sq.mm wire armoured ) confirming to is 3975:1990 ( no. of strip indicated in gtp ) & extruded pvc outer sheathed armoured cable with specified is 1554 part 1:1988 & confirming to gtp of group a.3.5 core 25 sqmm 4 labour charges for laying of 1.1 kv class ug cable in existing trench gi pipe / stoneware pipe / on wall / on pole as required.in existing trench / duct.25 sqmm to 75 sqmm 5 supplying and fixing l.t. cast iron pot heads suitable for 1.1 kv class ug cable filled with necessary bitumen / insulating compound complete with terminals, clamps, bolts, nuts and washers etc.25sqmm 6 supplying and fixing of heavy duty cable glands suitable for ug cable of 1.1 kv class ( metal only ) 25mm dia 7 supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes.25 sqmm long barrel 8 supplying, fixing, wiring, earth electrode for grounding conduits, i.c. cutouts and other equipments on the meter board using 40mm dia 2.90mm thick gi pipe 2.5 mtr long buried in a pit … the pit should be filled with equal proportion of salt and charcoal 150mm all round the pipe to complete depth. the connection from the pipe to the conduit etc., is to be established through gi wire of size as per isi specification 7.3.3. of is 732 using 12mm dia bolts, nuts, washers and check nuts etc., the pipe shall have 16 through holes of 122 mm dia 9 supply and installation / fixing / provision of pole box with hrc fuse / mcb provision and suitable connector / terminal for 3 ph / 1 ph connections with loop in & loop out terminals for 10 sqmm / 25 sqmm 3.5 c al / ar / cu / ar cable and branch out 2.5 sqmm 2 core al / cu pvc insulated cable, enclosed in a thermoplastic, polystyrene enclosure, which should be shock proof, safe, ip65 ( weather proof ) , rust proof, dust proof, water proof having internally embedded gasket with provision for cable entry through ip65 thermoplastic, polyamide glands and / or grommets.200mmx200mmx98mm 10 fabricating supplying and mounting ms box made out … swg suitable for floor / wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clamps with necessary cable entry pipe with gland and box should be finished with 2 coats of red oxide primer paint and finally finished with approved colour enameled metal paint etc., complete.14swg 11 panel box angle stand supplying and fixing angle iron frame work fabricated out of m.s .angle …..with bolts washers etc etc and painted with 2 coats of red oxideand then two coats of approved paint ( 32.9a ) c ) 75x75xx6mm 12 supplying and fixing moulded case circuit breaker ( mccb ) over the existing wood / panel board using necessary screws, bolts, nuts and wiring complete. protection of overload and short circuit with thermal magnetic / micro processor release and earth fault as per is 13947. ( icu = ics ) four pole 100amps 25ka. 13 supplying and fixing hrc fuse units base on existing switch / panel board.63a to 125amps 14 supplying and fixing hrc fuse link on existing switch fuse base with watt loss as per is 13703.up to 63amps 15 supply and fixing polished wood board made of not less than 15mm thick plank on both sides of not more than 2 pieces and fixing the same to the wall using tapered inverted wooden plugs screws.20x20x2.5 16 supplying of tpst with rewirable porcelain channels in sm enclosure. made out of 14 swg powder coated paint of approved colour.32amps 17 providing and fixing single phase autoswitch timer providing and fixing 3 phase 4pole contactor 40amps...

Ministry Of Power - Karnataka

33362825 bids are invited for supply of gi earth flats gi conduit 20mm dia 1.6mm thick , conduits & accessories:spec. / type gi circular pullout boxes 2 way:size 20 mm nom.dia , conduits & accessories:spec. / type gi circular box three way:size 20 mm nom.dia , conduits & accessories:spec. / type gi circular box four way:size 20 mm nom.dia , gi inspection bends suitable to 20mm conduit which shall be used for lighting purpose. , 190 to 210w led based flood light fitting , gi wire 16 swg for lighting , power cable : specification / voltage grade : is : 694 pvc insulated unarmoured, 1.1 kv grade : conductor : aluminium stranded : cable section : 1 c x 4 sq.mm , fitt mat junc box20 mm 4 way , 16a, sp mcb breaking capacity minimum 9ka, c type, din rail mount, voltage 240 / 415v, as per is 8828:1996 / iec 898 ( 1995 , conduits & accessories:spec. / type gi flexible conduit:size 20 mm nom.dia flexible conduit shall be water proof and rust proof. conduits shall be used for lighting purpose. , gi flat size 25mmx6mm, length minimum 5 meter each piece.ms flat shall conform to is 2062 & its latest amendments for steel & galvanization as per is 4759 & its latest amendments , gi earth flat of size 50x6 mm , g.i earth flat:size 25x6 mmtotal quantity : 17551...

Hindustan Aeronautics Limited - Karnataka

33256710 estimate for laying tiles and miscellaneous repairs to customs rooms in cargo complex in airport services centre, hal (bc) aluminium work & joinery: 1 supplying, fabricating & installing partly glazed partly panelled powder coated aluminium partitions with ivory colour comprising of anodised aluminium extruded rectungalar hollow tubes from high grade h.e 9 w.p alloy conforming to designation 63400 of is 737 of jindal,indal or other approved eqivalent manufacture comprising of the following for the partitions in the items etc., complete. a) partition frame anodised aluminium extruded rectanguler tubes not less than(101x44x2.1)mm in natural matt finish for partition frame work for door openings horizontal ,vertical,intermediate, outer frame members etc., at not exceeding 100cms centers (approx) b) bottom panel upto nearly 1m height from floor level fixed with 9mm thick navopan or other approved equilant particle board with integral laminate facing on both sides,with same colour and shade fine moisture and termite resistant quality etc, all complete as directed by engineer in charge c) balance panels fixed with 4mm thick sheet glass of approved quality,conforming to is 2835 in panes of size [1x1]m upto 2m and[1x0.75]m including providing glass louvers wherever required etc, all comple as directed by engineer in charge d) superior quality rubber glazing gaskets and aluminium tapered glazing clips0.7mm thick and measuring (19x17)mm self interlocking screwless, snap on type for fixing panel navopan board and glass panes etc.(the vertical member shall be embedded in cement concrete below the existing floor tiles if any to a minimum depth of 100mm including making holes in cement concrete floor and making the same including tiles if any etc, all complete as directed by engineer in charge 2 supplying fabricating and installing partly panelled and partly glazed single leaf door shutters frame of anodised aluminium extruded rectangular hollow tubes from high grade h.e 9 w.p alloy conforming to designation 63400 of is 737 of jindal, indal or other approved equivalent manufacture comprising of the following for the partitions in the items etc., complete a) door outer frame anodised aluminium extruded rectangular tubes not less than (101x44x2.1)mm in natural matt finish for outer door frame. b) shutter: shutter top member shall measure not less than (47x44x2.1)mm shutter bottom member shall measure not less than (95x44x3)mm shutter middle, horizontal and vertical members shall measure not less than (45x44x2.10)mm. c) superior quality rubber glazing gaskets and aluminium tapered glazing clip measuring (19x17)mm self interlocking screwless, snap on type for fixing particle boards and glass panes. d) hydraulically regulated door closer designation 3 with cast iron body or everite or other approved equivalent conforming to is 3564 or providing suitable heavy duty floor springs for each shutters. e) the shutter shall be approved shade and manufacture for glass panes. the door to be fitted with a neat and efficient security lock, butterfly handle, tower bolt rubber door stopper, insigna with red color for glass panel. woodwork work & joinery 3 supplying and fixing wall panelling made up of with ply wood boards of 19mm thick of approved brand with isi standards, firmly fixed on 100mm wide 19 thick ply wood stripes/ backings with necessary wedges/beadings firmly nailed/screwd to the existing masonry walls of any condition and at all heights rebated and prepared to receive decorative pattern as directed by the eic all joints shall be seemless etc., including making cut outs wherever required , scaffolding and making good the walls complete. 4 supplying and fixing veneers on to the wall panelling with all necessary adhesives/ glues including seemless pinning and making good the surfaces including applying touch wood or equivalent varnishing and prepared to receive decorative pattern as directed by the eic all joints shall be seemless etc., complete.(design/pattern of the veneers shall be approved by eic) 5 supplying and fixing harrison rails/curtain rails ms chromium plated with all necessary fittings,brackets etc painting work: 6 painting two coats of enamel paint for existing wooden surfaces including preparation of surfaces 7 painting two coats of enamel paint for existing inside masonary surfaces including preparation of surfaces 8 painting the interiors surfaces of walls and ceilings with two coats of distemper oil emulsion over the existing painted surfaces including preparations of old surfaces and chalk whitening preparatory to distempering etc., complete. including scaffolding wherever needed b walls floor finishes & pavings 9 supplying and fixing dark shade vitrified ceremic tiles 10mm thick of approved design,size square /rectangularpolished and area of tile not exceeding 0.36 sq.m and colour jointed with c.m.(1: 6) and pointed coloured cement to match the tiles including over a screed of c.m.(1: 6) 20mm thick bedding,curing etc., complete all as directed by the eic etc., complete. 10 supplying and fixing fancy type horzontal roller window screens/roller blinds of rexin/synthetic cloth made with fibre textured with desired shade and the screen(s) shall be openable with help of button type handles for easy operation of rolling up and down with a provision of intermediate stopper (that is partially openable) type with all neacessary slings for opening/closing operation etc complete including fixing of necessary clmaps/frame work at any height and with scaffolding etc complete 11 providing and fixing in true horizontal level false ceiling grid of prelude xl systems of standard manufacturer using hot dipped galvanized steel section, exposed surface chemically cleaned capping pre finished in baked polyester paint, main tee of size not less than (24 x 43)mm at every 1200mm c/c max mandatory stitched 1.20m cross t of size not less than (24 x 35)mm at every 600mm c/c and 0.60m cross ‘t’ of size not less than (24 x 30)mm and wall angle of size not less tham (19 x 19)mm to form grid of approximate size (600 x 600)mm. the main t of grid shall be suspended using 6mm thick pre straightened gi wires not less than 1200mm c/c by tying / welding to roof structural system including supplying and fixing pvc/ fibre board ceiling tiles regualr edge of size (600 x 600 x 16)mm, with properties of light reflection of more than 80%, sound absorption (nrc) 0.50, rh not less than 90%, of desired shade. the work is inclusive of making provision for the cut outs for the lights and other fixtures and neatly finishing the edges as per the instructions of the engineer in charge. .color and type of board should be got approved by hal before fixing. ...

Karnataka State Electronics Development Corporation Limited - Karnataka

33178697 supply & installation of high mast lights , fabrication, supplying, erection, testing and commissioning of ms long polygon high mast with single / multiple telescopic sections having, ( minimum overlap distance of 1.5 times of top section ) thickness as per bsen 10025 grades 355 jo / astm a572 50 steel sheet plate for shaft suitable to withstand a wind velocity of 47 m / s as per is 875 part 3 ( as per ga drawing ) . base plate as per is 2062 / astm a572 50. the mast shall be galvanized in single hot dip as per bsen iso 1461 / astm a123 with an average 70 microns as per is 2629, and welded as per bs 5135 single l seam joint the mast shall have 2 way head frame with die cast lm 6 pulleys, stainless steel axle, phosphorus bronze bearing bush press fitted with separate guides for 2 runs of 5 mm dia, stainless steel wire rope of aisi 304grade 7 / 19 core, ( factor of safety as per tr no 7 ) . 2.5 mm2 epr insulated pcp sheathed trailing power cable housed inside the bottom shaft of mast with door having locking arrangement the mast shall have manual / power tool ( suitable reversible geared motor operating on 230 / 415v, 50hz, the mast shall have 12.5 m top 100 mm and bottom 310 mm dia, supply of led floodlight ( 200 qs ) luminaire with pressure die cast aluminium housing body for optimal thermal dissipation. lamp compartment comprising of anti glare clear diffuser with injection moulded polycarbonate / clear glass material, delivering superior light output rated life burning hrs 50000 hr @ lumen maintenance of 70%, cct > 5500k, ip 66 optical and electrical compartment & impact resistance of complete luminaire > ik08. power factor >0.9 with mains, surge protection min 5kv along with over voltage / overload, short circuit / miss wiring protection. compatible for pole mauling with outer dia of 40mm to 50mm. universal voltage driver to operate wide voltage range from 100 v to 270v 50 / 60hz application. compliance to is 10322 / iec 60598, lm 79 & lm 80 adherence with rohs. ul approved mcpcb. top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools. led light fixture with w system power consumption. led efficiency> 1301m / w, nominal cri >75. luminaire manufacturer should have in house facility accredited by nabl / cpri & any government certified agency & design & development facility certified by iso 9001:2008. housing with supplier word mark / name shall be engraved / embossing on the die cast housing, supplying and drawing flexible multicore cable manufactured with electrolytic grade flexible copper with low conductor confirming to is 8130 1984 and ( virgin ) pvc insulation sheathed suitable for working voltage upto 1100v as peris 694:2010, supplying, fixing, wiring earth electrode for grounding conduits, i.c. cutouts and other equipments on the meter board using 40mm dia 2.90mm thick gi pipe 2.5 mtr long buried in a pit. the pit should be filled with equal proportion of salt and charcoal 150mm all round the pipe to complete depth. the connection from the pipe to the conduit etc, is to be established through gi wire of size as per isi specification 7.3.3. or is 732 using 12mm dia bolts, nuts, washers and check nuts etc., the pipe shall have 16 through holes of 12mm dia., supplying & fixing miniature circuit breakers on existing mcb distribution boards using necessary fixing materials and c type curve, indicator on / off, energy cross 3 with short circuit breaking capacity of 10k and complete wiring as required confirming to iec60898. 6 32 a sp, supplying, fixing and wiring electronic trivector meter ( etv ) 5 to 32 / 63 a three phase 4 wire whole current class 1accuracy energy meter., supplying of 1.1 kv lt ug cable xlpe or heat resistant pvc insulated pvc extruded inner sheath armoured ug lt cable as per is 1554 ( part ) or is 7098 part 1, armouringstrip thickness in average 5 and resistivity 14 ohms / kms ( max ) as per is 3975 4 core 16 sqmm, supplying and fixing microprocessor based astronomical timer switch with using necessary bolts, nuts and washers., supplying, fixing and wiring earth leakage relay with core balanced current transformer suitable for single phase 50 hz ac with latest microcontroller based, digital readout of percentage leakage current, programmable delay / auto / manualre set facility suitable to mount on dinrail / flush mounting on panel board., supplying and fixing of class a ( medium duty ) gi pipe of wall thickness not less than 3.25mm on pole / wall / drain crossing with necessary clamping arrangement for ug cable of 1.1 kv 50mm, digging of trench of 0.6m deep x 0.50 mtr wide refilling the trench to the required ground level and consolidating etc complete ( as per civil sr ksrb 1 2, p7 ) in soil ( hard ) , supplying, and fixing of hot dip galvanized m.s.bracket suitable for out door luminaries and mounted on octagonal pole using necessary bolts, nuts etc., complete. double arm bracket with 1500 mm standard 40 / 50 mm dia, earth work excavation in all kinds of soils depth upto 1.50m by manual means for drains, canals, waste weir, draft, approach channels, key trenches, foundation of bridges and such simillar works, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work, providing and laying in position plain cement concrete for levelling course for all works in foundation. the granite / trap / basalt crushed graded coarse aggregates and fine aggregates as per relevant is codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. ( the cost of steel reinforcement & formwork shall be paid separately ) mix 1:4:8 ( m5 ) using 40 mm nominal size graded crushed coarse aggregates, providing and laying in position reinforced cement concrete for all super structures of building , road works, water works, irrigation works & super structure works of bridges upto 3.50 m height. the granite / trap / basalt crushed graded coarse aggregates and fine aggregates as per relevant is codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. the cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant is codes , labour, usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. ( the cost of steel reinforcement, dowel bars & formwork to be paid separately ) m20 design mix using 20 mm nominalsize graded crushed coarse aggregates...

Karnataka State Electronics Development Corporation Limited - Karnataka

33167564 supply & installation of high mast lights supply & installation of high mast lights , fabrication, supplying, erection, testing and commissioning of ms long polygon high mast with single / multiple telescopic sections having, ( minimum overlap distance of 1.5 times of top section ) thickness as per bsen 10025 grades 355 jo / astm a572 50 steel sheet plate for shaft suitable to withstand a wind velocity of 47 m / s as per is 875 part 3 ( as per ga drawing ) . base plate as per is 2062 / astm a572 50. the mast shall be galvanized in single hot dip as per bsen iso 1461 / astm a123 with an average 70 microns as per is 2629, and welded as per bs 5135 single l seam joint the mast shall have 2 way head frame with die cast lm 6 pulleys, stainless steel axle, phosphorus bronze bearing bush press fitted with separate guides for 2 runs of 5 mm dia, stainless steel wire rope of aisi 304grade 7 / 19 core, ( factor of safety as per tr no 7 ) . 2.5 mm2 epr insulated pcp sheathed trailing power cable housed inside the bottom shaft of mast with door having locking arrangement the mast shall have manual / power tool ( suitable reversible geared motor operating on 230 / 415v, 50hz, the mast shall have 12.5 m top 100 mm and bottom 310 mm dia, supply of led floodlight ( 200 qs ) luminaire with pressure die cast aluminium housing body for optimal thermal dissipation. lamp compartment comprising of anti glare clear diffuser with injection moulded polycarbonate / clear glass material, delivering superior light output rated life burning hrs 50000 hr @ lumen maintenance of 70%, cct > 5500k, ip 66 optical and electrical compartment & impact resistance of complete luminaire > ik08. power factor >0.9 with mains, surge protection min 5kv along with over voltage / overload, short circuit / miss wiring protection. compatible for pole mauling with outer dia of 40mm to 50mm. universal voltage driver to operate wide voltage range from 100 v to 270v 50 / 60hz application. compliance to is 10322 / iec 60598, lm 79 & lm 80 adherence with rohs. ul approved mcpcb. top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools. led light fixture with w system power consumption. led efficiency> 1301m / w, nominal cri >75. luminaire manufacturer should have in house facility accredited by nabl / cpri & any government certified agency & design & development facility certified by iso 9001:2008. housing with supplier word mark / name shall be engraved / embossing on the die cast housing, supplying and drawing flexible multicore cable manufactured with electrolytic grade flexible copper with low conductor confirming to is 8130 1984 and ( virgin ) pvc insulation sheathed suitable for working voltage upto 1100v as peris 694:2010, supplying, fixing, wiring earth electrode for grounding conduits, i.c. cutouts and other equipments on the meter board using 40mm dia 2.90mm thick gi pipe 2.5 mtr long buried in a pit. the pit should be filled with equal proportion of salt and charcoal 150mm all round the pipe to complete depth. the connection from the pipe to the conduit etc, is to be established through gi wire of size as per isi specification 7.3.3. or is 732 using 12mm dia bolts, nuts, washers and check nuts etc., the pipe shall have 16 through holes of 12mm dia., supplying & fixing miniature circuit breakers on existing mcb distribution boards using necessary fixing materials and c type curve, indicator on / off, energy cross 3 with short circuit breaking capacity of 10k and complete wiring as required confirming to iec60898. 6 32 a sp, supplying, fixing and wiring electronic trivector meter ( etv ) 5 to 32 / 63 a three phase 4 wire whole current class 1accuracy energy meter., supplying of 1.1 kv lt ug cable xlpe or heat resistant pvc insulated pvc extruded inner sheath armoured ug lt cable as per is 1554 ( part ) or is 7098 part 1, armouringstrip thickness in average 5 and resistivity 14 ohms / kms ( max ) as per is 3975 4 core 16 sqmm, supplying and fixing microprocessor based astronomical timer switch with using necessary bolts, nuts and washers., supplying, fixing and wiring earth leakage relay with core balanced current transformer suitable for single phase 50 hz ac with latest microcontroller based, digital readout of percentage leakage current, programmable delay / auto / manualre set facility suitable to mount on dinrail / flush mounting on panel board., supplying and fixing of class a ( medium duty ) gi pipe of wall thickness not less than 3.25mm on pole / wall / drain crossing with necessary clamping arrangement for ug cable of 1.1 kv 50mm, digging of trench of 0.6m deep x 0.50 mtr wide refilling the trench to the required ground level and consolidating etc complete ( as per civil sr ksrb 1 2, p7 ) in soil ( hard ) , supplying, and fixing of hot dip galvanized m.s.bracket suitable for out door luminaries and mounted on octagonal pole using necessary bolts, nuts etc., complete. double arm bracket with 1500 mm standard 40 / 50 mm dia, earth work excavation in all kinds of soils depth upto 1.50m by manual means for drains, canals, waste weir, draft, approach channels, key trenches, foundation of bridges and such simillar works, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work, providing and laying in position plain cement concrete for levelling course for all works in foundation. the granite / trap / basalt crushed graded coarse aggregates and fine aggregates as per relevant is codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. ( the cost of steel reinforcement & formwork shall be paid separately ) mix 1:4:8 ( m5 ) using 40 mm nominal size graded crushed coarse aggregates, providing and laying in position reinforced cement concrete for all super structures of building , road works, water works, irrigation works & super structure works of bridges upto 3.50 m height. the granite / trap / basalt crushed graded coarse aggregates and fine aggregates as per relevant is codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. the cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant is codes , labour, usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. ( the cost of steel reinforcement, dowel bars & formwork to be paid separately ) m20 design mix using 20 mm nominalsize graded crushed coarse aggregates...

Karnataka State Electronics Development Corporation Limited - Karnataka

33167546 supply & installation of high mast lights supply & installation of high mast lights , fabrication,supplying,erection,testing and commissioning of ms long polygon high mast with single/multiple telescopic sections having, (minimum overlap distance of 1.5 times of top section) thickness as per bsen 10025 grades 355 jo/astm a572 50 steel sheet plate for shaft suitable to withstand a wind velocity of 47 m/s as per is 875 part 3(as per ga drawing). base plate as per is 2062/astm a572 50. the mast shall be galvanized in single hot dip as per bsen iso 1461/astm a123 with an average 70 microns as per is 2629, and welded as per bs 5135 single l seam joint the mast shall have 2 way head frame with die cast lm 6 pulleys, stainless steel axle, phosphorus bronze bearing bush press fitted with separate guides for 2 runs of 5 mm dia, stainless steel wire rope of aisi 304grade 7/19 core, (factor of safety as per tr no 7). 2.5 mm2 epr insulated pcp sheathed trailing power cable housed inside the bottom shaft of mast with door having locking arrangement the mast shall have manual/power tool (suitable reversible geared motor operating on 230/415v, 50hz, the mast shall have 12.5 m top 100 mm and bottom 310 mm dia,supply of led floodlight (200 qs) luminaire with pressure die cast aluminium housing body for optimal thermal dissipation. lamp compartment comprising of anti glare clear diffuser with injection moulded polycarbonate/clear glass material, delivering superior light output rated life burning hrs 50000 hr @ lumen maintenance of 70%, cct > 5500k, ip 66 optical and electrical compartment & impact resistance of complete luminaire > ik08. power factor >0.9 with mains, surge protection min 5kv along with over voltage/ overload, short circuit/ miss wiring protection. compatible for pole mauling with outer dia of 40mm to 50mm. universal voltage driver to operate wide voltage range from 100 v to 270v 50/60hz application. compliance to is 10322/ iec 60598, lm 79 & lm 80 adherence with rohs. ul approved mcpcb. top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools. led light fixture with w system power consumption. led efficiency> 1301m/w, nominal cri >75. luminaire manufacturer should have in house facility accredited by nabl / cpri & any government certified agency & design & development facility certified by iso 9001:2008. housing with supplier word mark / name shall be engraved / embossing on the die cast housing,supplying and drawing flexible multicore cable manufactured with electrolytic grade flexible copper with low conductor confirming to is 8130 1984 and (virgin) pvc insulation sheathed suitable for working voltage upto 1100v as peris 694:2010,supplying, fixing, wiring earth electrode for grounding conduits, i.c. cutouts and other equipments on the meter board using 40mm dia 2.90mm thick gi pipe 2.5 mtr long buried in a pit. the pit should be filled with equal proportion of salt and charcoal 150mm all round the pipe to complete depth. the connection from the pipe to the conduit etc, is to be established through gi wire of size as per isi specification 7.3.3. or is 732 using 12mm dia bolts, nuts, washers and check nuts etc., the pipe shall have 16 through holes of 12mm dia.,supplying & fixing miniature circuit breakers on existing mcb distribution boards using necessary fixing materials and c type curve, indicator on/off, energy cross 3 with short circuit breaking capacity of 10k and complete wiring as required confirming to iec60898. 6 32 a sp,supplying, fixing and wiring electronic trivector meter (etv) 5 to 32/63 a three phase 4 wire whole current class 1accuracy energy meter.,supplying of 1.1 kv lt ug cable xlpe or heat resistant pvc insulated pvc extruded inner sheath armoured ug lt cable as per is 1554 (part) or is 7098 part 1, armouringstrip thickness in average 5 and resistivity 14 ohms/kms (max) as per is 3975 4 core 16 sqmm,supplying and fixing microprocessor based astronomical timer switch with using necessary bolts, nuts and washers.,supplying, fixing and wiring earth leakage relay with core balanced current transformer suitable for single phase 50 hz ac with latest microcontroller based, digital readout of percentage leakage current, programmable delay / auto/ manualre set facility suitable to mount on dinrail/flush mounting on panel board.,supplying and fixing of class a (medium duty) gi pipe of wall thickness not less than 3.25mm on pole/wall/drain crossing with necessary clamping arrangement for ug cable of 1.1 kv 50mm,digging of trench of 0.6m deep x 0.50 mtr wide refilling the trench to the required ground level and consolidating etc complete (as per civil sr ksrb 1 2, p7) in soil (hard),supplying, and fixing of hot dip galvanized m.s.bracket suitable for out door luminaries and mounted on octagonal pole using necessary bolts, nuts etc.,complete. double arm bracket with 1500 mm standard 40/50 mm dia,earth work excavation in all kinds of soils depth upto 1.50m by manual means for drains, canals, waste weir, draft, approach channels, key trenches, foundation of bridges and such simillar works, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work,providing and laying in position plain cement concrete for levelling course for all works in foundation. the granite / trap / basalt crushed graded coarse aggregates and fine aggregates as per relevant is codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (the cost of steel reinforcement & formwork shall be paid separately) mix 1:4:8( m5) using 40 mm nominal size graded crushed coarse aggregates,providing and laying in position reinforced cement concrete for all super structures of building , road works, water works, irrigation works & super structure works of bridges upto 3.50 m height. the granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant is codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. the cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant is codes , labour, usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (the cost of steel reinforcement, dowel bars & formwork to be paid separately) m20 design mix using 20 mm nominalsize graded crushed coarse aggregates...

Karnataka State Electronics Development Corporation Limited - Karnataka

33167530 supply & installation of high mast lights supply & installation of high mast lights , fabrication, supplying, erection, testing and commissioning of ms long polygon high mast with single / multiple telescopic sections having, ( minimum overlap distance of 1.5 times of top section ) thickness as per bsen 10025 grades 355 jo / astm a572 50 steel sheet plate for shaft suitable to withstand a wind velocity of 47 m / s as per is 875 part 3 ( as per ga drawing ) . base plate as per is 2062 / astm a572 50. the mast shall be galvanized in single hot dip as per bsen iso 1461 / astm a123 with an average 70 microns as per is 2629, and welded as per bs 5135 single l seam joint the mast shall have 2 way head frame with die cast lm 6 pulleys, stainless steel axle, phosphorus bronze bearing bush press fitted with separate guides for 2 runs of 5 mm dia, stainless steel wire rope of aisi 304grade 7 / 19 core, ( factor of safety as per tr no 7 ) . 2.5 mm2 epr insulated pcp sheathed trailing power cable housed inside the bottom shaft of mast with door having locking arrangement the mast shall have manual / power tool ( suitable reversible geared motor operating on 230 / 415v, 50hz, the mast shall have 12.5 m top 100 mm and bottom 310 mm dia, supply of led floodlight ( 200 qs ) luminaire with pressure die cast aluminium housing body for optimal thermal dissipation. lamp compartment comprising of anti glare clear diffuser with injection moulded polycarbonate / clear glass material, delivering superior light output rated life burning hrs 50000 hr @ lumen maintenance of 70%, cct > 5500k, ip 66 optical and electrical compartment & impact resistance of complete luminaire > ik08. power factor >0.9 with mains, surge protection min 5kv along with over voltage / overload, short circuit / miss wiring protection. compatible for pole mauling with outer dia of 40mm to 50mm. universal voltage driver to operate wide voltage range from 100 v to 270v 50 / 60hz application. compliance to is 10322 / iec 60598, lm 79 & lm 80 adherence with rohs. ul approved mcpcb. top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools. led light fixture with w system power consumption. led efficiency> 1301m / w, nominal cri >75. luminaire manufacturer should have in house facility accredited by nabl / cpri & any government certified agency & design & development facility certified by iso 9001:2008. housing with supplier word mark / name shall be engraved / embossing on the die cast housing, supplying and drawing flexible multicore cable manufactured with electrolytic grade flexible copper with low conductor confirming to is 8130 1984 and ( virgin ) pvc insulation sheathed suitable for working voltage upto 1100v as peris 694:2010, supplying, fixing, wiring earth electrode for grounding conduits, i.c. cutouts and other equipments on the meter board using 40mm dia 2.90mm thick gi pipe 2.5 mtr long buried in a pit. the pit should be filled with equal proportion of salt and charcoal 150mm all round the pipe to complete depth. the connection from the pipe to the conduit etc, is to be established through gi wire of size as per isi specification 7.3.3. or is 732 using 12mm dia bolts, nuts, washers and check nuts etc., the pipe shall have 16 through holes of 12mm dia., supplying & fixing miniature circuit breakers on existing mcb distribution boards using necessary fixing materials and c type curve, indicator on / off, energy cross 3 with short circuit breaking capacity of 10k and complete wiring as required confirming to iec60898. 6 32 a sp, supplying, fixing and wiring electronic trivector meter ( etv ) 5 to 32 / 63 a three phase 4 wire whole current class 1accuracy energy meter., supplying of 1.1 kv lt ug cable xlpe or heat resistant pvc insulated pvc extruded inner sheath armoured ug lt cable as per is 1554 ( part ) or is 7098 part 1, armouringstrip thickness in average 5 and resistivity 14 ohms / kms ( max ) as per is 3975 4 core 16 sqmm, supplying and fixing microprocessor based astronomical timer switch with using necessary bolts, nuts and washers., supplying, fixing and wiring earth leakage relay with core balanced current transformer suitable for single phase 50 hz ac with latest microcontroller based, digital readout of percentage leakage current, programmable delay / auto / manualre set facility suitable to mount on dinrail / flush mounting on panel board., supplying and fixing of class a ( medium duty ) gi pipe of wall thickness not less than 3.25mm on pole / wall / drain crossing with necessary clamping arrangement for ug cable of 1.1 kv 50mm, digging of trench of 0.6m deep x 0.50 mtr wide refilling the trench to the required ground level and consolidating etc complete ( as per civil sr ksrb 1 2, p7 ) in soil ( hard ) , supplying, and fixing of hot dip galvanized m.s.bracket suitable for out door luminaries and mounted on octagonal pole using necessary bolts, nuts etc., complete. double arm bracket with 1500 mm standard 40 / 50 mm dia, earth work excavation in all kinds of soils depth upto 1.50m by manual means for drains, canals, waste weir, draft, approach channels, key trenches, foundation of bridges and such simillar works, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work, providing and laying in position plain cement concrete for levelling course for all works in foundation. the granite / trap / basalt crushed graded coarse aggregates and fine aggregates as per relevant is codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. ( the cost of steel reinforcement & formwork shall be paid separately ) mix 1:4:8 ( m5 ) using 40 mm nominal size graded crushed coarse aggregates, providing and laying in position reinforced cement concrete for all super structures of building , road works, water works, irrigation works & super structure works of bridges upto 3.50 m height. the granite / trap / basalt crushed graded coarse aggregates and fine aggregates as per relevant is codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. the cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant is codes , labour, usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. ( the cost of steel reinforcement, dowel bars & formwork to be paid separately ) m20 design mix using 20 mm nominalsize graded crushed coarse aggregates...