New Mangalore Port Trust - Karnataka

39632339 tender for electrification work at pharmacy and other allied works at nmpa hospital supplying and wiring adopting loop system in existing pvc conduit casing and capping using 2x1.5 sq.mm (phase & neptral) & 1x1.0 sq.mm (earth wire) frls multistrand pvc insulated copper wire without control switch shall be fked on the existing plastic sheet / gang box, the other end of the wires shall be terminated with sufficient loose length in a wood /pvc round block complete for each out let. a) medium point b) lons point 4 nos. 4 nos. 2 supplying and fixing 25mm pvc casing and capping on the wall or ceiling using necessary materials like bends, junction boxes, elbows, screws at an interval of 300mm. etc. as required. 30 mirs 3 supplying of heavy gauge pvc conduit pipe 20mm dia 2mm thick confirming to is 2549 with suitable s2e bends, junction boxes, adhesive paste etc, complete. supplying capacitor type 48 sweef ceiling fan compltte with down rod, blades, shackle, canopies etc. for operation on 230v, 50h2, single phase ac supply confirming to iss 374 1979 and with double ball bearin fixing a ceiling fan of a1l capacities and all types to the existing s hook with fan regulator to the existing board with 5a ceiling rose of approved quality with necessary length of 2310.0076 pvc insulated twin twisted copper wire and r.virinq complete. supplying and wiring for lighting /power circuit using frls pvc insulated wire 1100v grade, multi strand copper wire with low conductor resistance single core cable in open or concealed system. al2.5 sq.mm wire b) 4 sq.mm wire supplying surface mounting powder coated unbreakable pvc modular box suitable for fixing mounting modular switch plates. t a) 2 way b) 6 way c) 10 12 wa 100 nltr 50 mtr 4 nos. 5 nos. 1 no. supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts and nuts etc. complete on the existing pvc box. a) 2 module b) 6 module c) 12 module 4 nos. 5 nos. 1 no. supplying and fixing of following modular type materials on existing modular switch plates. a) 6 amp switch b) 6 amp 3 way socket t cl 6116 amp universal socket 32a dp switch supplying and fixing of recess mounting non integral type 2x2x36watt led luminaries. suppt l 20 nos. 1 1 nos. 2 nos. 2 nos. supplying and fixing of 12way double door spn distribution board. supplying and fixing of miniature circuit breaker. a)6,{ sp mcb b) 25a dp mcb c) 32a tpn mcb 4 nos. 2 nos. 1 no. 14 iupplying and fixing of 15mm ms rod md hook for fixins of fans....

Karnataka Power Corporation Limited - Karnataka

38932776 supply of rigid al tubular conductor, corona bell and earthing rods etc., for svp, kpcl, jogfalls 577 435 earthing rod for 220kv yard, frp earthing / discharge rods, bimetalic strip cu al 2mm, bimetalic strip cu al, tension string turn buckle, paddle clamp 1400amps, corona bell 3 inch al tube, corona bell 2.5 inch al tube, cleat clamp 7 / 3.65mm gshield, pad clamp 7 / 3.65mm gshieldwire, earth wire tension clamp 7 / 3.6, neutral bus bpi 2.5 inch al tube, palm connector for studd 30mm, c type wedge connector paddle, exp connector 2.5 inch al horizont, exp connector 2.5 inch al horiznta, exp connector 3 inch al horizontal, connector for 123kv la 2.5inch, interconnector 3 feet 2.5feet al tube, gt neutral bushing connector, gt hv bushing connector, connector acsr drake conductor, exapnsion connector 3 feet al tube, connector drake & 2 point 5 feet al tube, rigid al tubular conductor 220...

Military Engineer Services - Karnataka

38897077 tender for provision of certain minor works 03 to 05 for e m at 58 su af station chimney hills. 1 supply and fixing tpn distribution boards, vertical type, protection class ip 43, double door, 4 way, concealed in wallsuitable for mounting mccb ampsas incomer and mcb sp, tp as outgoing with min 160 amps rating bus bar , concealed in wall all as specified and directed by engineer in charge . 2 supply and fixing 415v, 10 ka b curve miniature circuit breaker ( mcb ) of tp and current carrying capacity 50 amp, in the mcb db complete with connection testing and commissioning. 3 supply and fixing 240v, 10 ka b curve miniature circuit breaker ( mcb ) of single poles and current carrying capacity 5 to 32 amp, in the mcb db complete with connection testing and commissioning. 4 supply and fixing mccb , 3 pole , 415 v adjustabletype , with breaking capacity 100 amps all as specified and directed by engineer in charge . 5 m&l in repair earthing complete with galvanised steel pipe electrode of size 40 mm bore, medium grade, 2.5 meter length, burried directly in ground in bore 350 mm dia verticaliy to a depth not less 3.2 meter below ground level with top edge of the pipe not less than 60 cm below normal ground level connected to galvanised earth lead wire 4.0mm dia by meanswith bolts, nuts check nuts and washers protected by gl light grade pipe of size 15 mm dia and connecting up with the db as the case may be upto a maximum distance of 7.5m away from the earth electrode including test point junction, excavation, earthwork, pcc chamber, rcc cover ( yellow painted ) with handle , watering pipe 20mm dia gi medium grade with funnel and wire mesh, charcoal dust , salt, mild steel earth markerwith earthing result , dateall as per plate no.2 of ssr 1991 and as directed by engineer in charge.note: boring charges are included in the above quoted rates . 6 supply and fixing smc meter boxes , suitable for 3 phase meter of size 485 mm x 340 mm x 185 mm with transparent lid , single piece moulded, concealed metal hinges , wall mounted all as specified and directed by engineer in charge .cat part no gsmb 4834 of sintex or equivalent as per makes approved by command . 7 supply and fixing smc meter boxes , suitable for singlephase meter of size 285 mm x 230 mm x 125 mm with transparent lid , single piece moulded, concealed metal hinges , wall mounted all as specified and directed by engineer in charge .cat part no gsmb 2823 of sintex or equivalent as per makes approved by command . 8 m&l industrial five core 6 sqmmflexible cable , 1100 v pvc insulated & sheathed with bare annealed copper conductor as per is 694 2010 all as specified and directed . 9 m&l industrial three core 4sqmmflexible cable , 1100 v pvc insulated & sheathed with bare annealed copper conductor as per is 694 2010 all as specified and directed . 10 supply and fix trunking gi cable tray of size 150 mm width, 50 mm height , thickness 2.0 mmwith cover of size 155 mm width , 12 mm height, 2 mm thickness and accessories ( any type of joint and bends ) with fittings ( channel, fasteners, anchor bolt ) all as specified and directed. 11 earth continuity conductor or main earthing lead fixed to wall on batten, on ceilingany other indicated situation for loop earthing etc. as required 20 x 3 mm copper wireon porceilin insulator by distance 450 mm all as specified and directed .note : porceilien insulator cost is included in the above quoted rates . 12 m&l air termination, singlepointed, copper rod 12mm dia and 300mm long all as specified and directed . 13 supply and fix test point terminal block made of gun metal or phosphorus bronze size 75x75x25mmdrilled and screwed including 3 nos. 8mm dia 25mm long hex. head screw all as specified and directed . 14 m&l in repair earthing complete with copper pipe electrode of size 40 mm bore, medium grade, 2.5 meter length, burried directly in ground in bore 350 mm dia verticaliy to a depth not less 3.2 meter below ground level with top edge of the pipe not less than 60 cm below normal ground level connected to copper earth lead strip25 mm x 3 mm by meanswith bolts, nuts check nuts and washers protected by gl light grade pipe of size 40 mm dia and connecting up with the testing point as the case may be upto a maximum distance of 7.5m away from the earth electrode including test point junction, excavation, earthwork, pcc chamber, rcc cover ( yellow painted ) with handle , watering pipe 20mm dia gi medium grade with funnel and wire mesh, charcoal dust , salt, mild steel earth markerwith earthing result , dateall as per plate no.2 of ssr 1991 and as directed by engineer in charge.note: boring charges are included in the above quoted rates . 15 supply and fix microprocessor based programmable timer for air conditioner ( 2 tons capacity ) of 2 acs at 4 hrs or 8 hrs intervalall as specified and directed . 16 supply and fix air cooled split unit air conditioner , invertor type, electric driven single phase of capacity of 2 tr, bee 5 star rated including remote , ac stand , copper piping with insulationupto 10 mtr lenghall as specified and directed . 17 m&l submain wiring for circuit / submain wiring alongwith earth wire withfrls , pvc insulated copper conductor, single core cable in surface as required 2 x 4 sqmm + 1 x 4 sqmm earth wire with pvc conduit 25 mm diaall as specified and directed by engineer in charge . 18 supply and fix sheet metal enclosures with socket, plug top including mcb spcapacity 20 amps, concealed in wallall as specified and directed by engineer in charge ....

Hindustan Petroleum Corporation Limited - Karnataka

38847214 bids are invited for ht yard electrical works 1 dismantling and shifting of existing ht equipment providing expertise manpower to dismantle the existing ht yard equipment comprising of 4 pole structure with cross arm supports and ht switch gears transformer stayset civil work foundations ht yard fencing mild steel gates metal chips etc. and shifting same to a designated area within the site premise for safe keeping as per instructions of engineer in charge. job includes clearance of all debris from the area and leveling the ht yard to match surrounding ffl note vendor shall engage mechanized equipment for above job and ensure the entire job is carried out safely without causing any damages to the switch gears during dismantling and shifting operations. 2 supply laying connection testing and commissioning of pvc xlpe insulated armoured aluminum cables of ayxfy 3.5c x 25 mm2 including supports clamps termination of cables with lugs and glands etc. bare earth wire to be binded with cables and taken to the same saddles clamps of cable fixing all complete from main power supply to various panels. the item of single compression double compression glands along with its termination shall be included in this item for both sides of cable. 3 installation of electrical accessories including cable tags cable marker nickle plated lugs double compressed brass cable glands brass adaptor reducers nipples fixing of metallic anchor fasteners for supporting of cable trays and misc. electrical switch gear including all labour and materials complete as required and as per directions of engineer in charge. 4 revamping of earth pit the job includes identifying the old worn out earth pits carrying out reconstruction of civil work and allied jobs so as to make the earth pit as per is 3043 bringing the resistance below 2 ohms by adding salt and charcoal. fixing funnels if damaged. painting the plastered external and internal surface of chamber and testing the earth pit marking the resistance value on the existing earthing display board of 1 x 1 feet etc complete. 5 statutory approval electrical system cea scope of work includes but limited to preparation of all drawings sld earthing layout etc documents liasoning with the state and central govt. electricity bodies authorities cea mppkvvcl electrical inspectorate making complete arrangements of visit of govt. officials from central & state electricity bodies without any extra cost to hpcl compliance of all the points issued during visit within a week and obtaining all required statutory approvals for charging of new modified facilities obtaining cea approvals for new lt panels. the job shall also include obtaining any other approval associated with this job not mentioned above but required for successful commissioning of the entire job. note all statutory fees shall be paid by hpcl. however liasoning shall be made by the party with the electrical authorities. total quantity : 105...

Department Of Telecommunications - Karnataka

38068939 bids are invited for to te uppunda and general servicing disconnecting and shifting dg , loading dg on transport vehicle , transporting dg , unloading dg , providing dg foundation with bricks , installing dg , servicing b check for dg , v belts , radiator coolant , metallic flexible fuel pipe , 6 swg earth wire on ground , 6 swg earth wire on surface , laying ug cable , end termination of cable shifting of 20kva ea set from telecom stores at mangalore total quantity : 59...

Karnataka Power Corporation Limited - Karnataka

36905307 supply of 220kv clamp connectors procurement of 220kv clamp connectors , twin moose line asmb 245kv la, twin moose line asmb 400kv la, clamp 203, clamp 206, clamp 219, clamp 209a, clamp no 409a, clamp no 405a, clamp 204a, clamp 212, clamp 223, clamp 502a, clamp no 414a, clamp no 420, clamp no 508, clamp no 520a, fired wedge connector, 2 hole lynx paddle clamp, 4 hole lynx paddle clamp, pg clamp 11kv coyote, 11kv acsr conductor, pad clamp 11kv rabbit, bi metalic sheet, p.g. clamp for lynx acsr, cleat clamp for gi shieldwire, pg clamp for gi shield wire, tee connector for lynx acsr, terminal connector on isolator, rigid connector for al. tube, connector lynx on isolator, connector for al. tube on cb, rigid connector al, tube on ct, rigid connectoe al tube on pt, rigid type connt al tube on pt, rigid / sliding type connector, expansion terminal connector, angular tee connector al tube, inverted vee connector, corona bell for 2.5inchipsal tube, welding sleeve for 2.5inchaltube, pad connt for gi earth wire...

Karnataka Power Corporation Limited - Karnataka

35738452 supply of 220kv clamp connectors procurement of 220kv clamp connectors , twin moose line asmb 245kv la, twin moose line asmb 400kv la, clamp 203, clamp 206, clamp 219, clamp 209a, clamp no 409a, clamp no 405a, clamp 204a, clamp 212, clamp 223, clamp 502a, clamp no 414a, clamp no 420, clamp no 508, clamp no 520a, fired wedge connector, 2 hole lynx paddle clamp, 4 hole lynx paddle clamp, pg clamp 11kv coyote, 11kv acsr conductor, pad clamp 11kv rabbit, bi metalic sheet, p.g. clamp for lynx acsr, cleat clamp for gi shieldwire, pg clamp for gi shield wire, tee connector for lynx acsr, terminal connector on isolator, rigid connector for al. tube, connector lynx on isolator, connector for al. tube on cb, rigid connector al, tube on ct, rigid connectoe al tube on pt, rigid type connt al tube on pt, rigid / sliding type connector, expansion terminal connector, angular tee connector al tube, inverted vee connector, corona bell for 2.5inchipsal tube, welding sleeve for 2.5inchaltube, pad connt for gi earth wire...

Airports Authority Of India - Karnataka

35459068 construction of ils at kalaburagi airport sh electrical works supply of 20w led fixture surface and wall mounted led batten, extruded aluminium housing provided for efficient heat dissipation with polycarbonate diffuser & integrated electronic driver.led luminaire shall be suitable for 230v, 50hz. 1 phase ac supply as required. ( led and driver should meet aai specifications ) ( make: havells model: lumilineplusneo20wled865spcssind ) or equivalent 2 supply of 40 watts led outdoor type light fitting with pressure die cast aluminum housing, heat resistant glass, high power leds with secondary optics, ip67 protectionindulding integral control driver with top opening driver cover operates on single phase , 230 volts, 50hz, ac power supply etc. complete as required. ( make: crompton model:lsts 40 cdl m ) or equivalent 3 supply of 300mm , 1400rpm heavy duty exhaust fan with 4 blades, bird protective guard andallother required accessories suitable for working at 230volts, 50hz, single phase, ac supply etc. as required. ( make: havells or equivalent fromlist of approved makes ) 4 wiring for group controlled ( looped ) light point / fan point / exhaust fan point / call bell point ( without independent switch etc. ) with 1.5 sq. mm frls pvc insulated copper conductor single core cable in surface / recessed steel conduit, and earthing the point with 1.5 sq. mm frls pvc insulated copper conductor single core cable etc as required. group b 5 wiring for light point / fan point / exhaust fan point / call bell point with 1.5 sqmm frls pvc insulated copper conductor single core cable in surface / recessed steel conduit, with modular switch, modular plate, suitable gi box and earthing the point with 1.5sqmm frls pvc insulated copper conductor single core cable etc. as required. group b 6 wiring for light / power plug with 2 x 4 sq.mm frls pvc insulated copper conductor single core cable in surface / recessed medium class steel conduit alongwith 1 no. 4 sq.mm frls pvc insulated copper conductor single core cable for loop earthing as required 7 wiring for circuit / submain wiring alongwith earth wire with the following sizes of frls pvc insulated copper conductor, single core cable in surface / recessed steel conduit as required 2 x 2.5 sq.mm + 1 x 2.5 sq.mm earth wire 8 supplying and fixing suitable size gi box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5 / 6modular socket outlet and 5 / 6 a modular switch, connections etc. as required. 9 supplying and fixing suitable size gi box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 15 / 16 a modular socket outlet and 15 / 16 a modular switch, connections etc. as required. 10 supplying and fixing of following ways surface / recess mounting, vertical type, 415 volts, tpn mcb distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 amps tinned copper bus bar, common neutral link, earthbar, din bar for mounting mcb’s ( but without mcb’s and incomer ) as required . 8 way ( 4 + 4+24 ) , tpn, mcb db, double door 11 supplying and fixing following way, single pole and neutral, sheet steel, mcbdistribution board, 240 v, on surface / recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. ( but without mcb / rccb / isolator ) .12 way, double door 12 supplying and fixing 5 a to 32 a rating, 240 / 415 v, 10 ka, c curve, miniature circuit breaker suitable for inductive load of following poles in the existing mcb db complete with connections, testing and commissioning etc. as required. double pole 13 supplying and fixing of 63 amp rating, four poles, ( three phase and neutral ) 415 volts, isolator in the existing mcb db complete with connections, testing and commissioning etc. as required. 14 supplying and fixing following rating, four pole, 63a ( three phase and neutral ) , 415 v, residual current circuit breaker ( rccb ) , having a sensitivity current 30 ma in the existing mcb db complete with connections, testing and commissioning etc. as required. 15 installation, testing & commissioning of 40 w led type outdoor light fixture on single arm g.i bracket including provided 600mm length g.i bracket to be fixed on the outside cornors of the building with clamps, connections with 3c x 1.5 sq.mm frls pvc sheathed copper conductor, single core cables from lighting pointetc., complete as required. 16 installation, testing and commissioning of pre wired, fluorescent fitting / compact fluorescent fitting / led fitting of all types, complete with all accessories and tube / lamp etc. directly on ceiling / wall, including connections with 1.5 sq. mm frls pvc insulated, copper conductor, single core cable and earthing etc. as required. 17 installation, testing and commissioning of 300mm sweep, high speed, powder coated robust metalic exhaust fan with bird guard, including necessary accessories, wiringwith 1.5 sq. mm frls pvc insulated, copper conductor, single core cable etc. complete as required 18 supplying and fixing following way, single pole and neutral, sheet steel, mcb distribution board, 240 v, on surface / recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. ( but without mcb / rccb / isolator ) .8 way, double door 19 supplying and fixing 20 a, 240 v, spn industrial type socket outlet, with 2 pole and earth, metal enclosed plug top along with 20 a c curve, sp, mcb, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required. 20 supply, installation, testing and commissioning of addressable type fire alarm control panel having minimum one loop suitable for connecting sensors, manual call points, hooters and response indicators operation on 230 volts, 50 hz power supply, display to indicate fire and normal operation & power supply status, push button for accept and reset, sealed lead acid batteries with minimum 24v dc backup minimum 2hrs on alarm mode & normal operation mode with battery charger etc., shall be complete as required. panel shall have necessary provision for connecting and functioning with auto dialer etc. as required 21 sitc of auto dialer with all necessary accessoriesincluding connections etc. as required. 22 supply & fixing ofmanual call point complete with all accessories including connections of etc. as required 23 sitc of hooter with base plate etc. as required.. 24 supply & fixing of photoelectric, multi sensor smoke detectors along with mounting base with unique optical sensing chamber, visible leds complete with all accessories including connections etc. as required. ( as per approved makes list ) 25 sitc of response indicator in the existing false ceiling etc. as required. 26 supply and laying of 20 mm dia ms steel conduits isi marked red painted with all fittings and saddles for drawingcontrol cables on surface / recess / above false ceiling / concealed. etc. as required 27 supply and laying of xlpe insulated pvc sheathed / xlpe armoured control cable of sizefrls2cx1.5sq.mm copper conductor cable 650 / 1100v grade as per is 7098 ( part 1 ) 1988 in the existingconduit as required. 28 supply of single phase 1.5 ton 5 star rating split air conditioner of wall mounting inverter type consisting of non ductable single type room evaporator unit ( copper coil ) with cordless remote control and one number outdoor condensing unit comprising of compressor and refrigerant r 410a, suitable for operation on 230v, 50hz. ac supply i / c supply of all accessories i.e. copper pipe, interconnecting cable, drain pipe, full charge of refrigerant etc., as required. 29 installation, testing and commissioning of single phase 1.5 ton split air conditioner of high wall mounting type with minimum 5 star rating including fixing the condenser unit on raising standand fixing of evaporator unit including providing and making inter connections between evaporator unit and condenser unit up to a length of 3 mtrs etc. as required. 30 supply and fixing of following for interconnections between evaporator unit and condensing unit ( extra length ) for1.5 ton ac, as required as per oem. i. 1 / 4dia copper pipe with insulation or as per oem.ii. 1 / 2copper pipewith insulation or as per oem.iii. 2 x 2.5 sq. mm+ 1.5 sq.mm copper conductor cable or as per oem.. iv. rigid pvc pipe / pvc trunking of suitable size for covering the refrigerant line for above 31 providing and laying of 25 mm cpvc drain pipepipe for 1.5 trsplit type a.c units withnecessary saddles complete etc. as required. 32 supply and fixing of 4 kva voltage stabilizerwall mounting type suitable for 1.5 ton split unit with in put volt range 170v to 270 v & output 220 +10% etc., as required 33 supply, installation, testing and commissioning of automatic 24 hrs programmable timer suitable to 1.5tr to 2 tr capacity split ac units for running alternately etc. as required 34 excavation of the cable trenches in hard rock not exceeding 1.5 metres in width, and lift upto 1.5 metres, including getting out the excavated soil and disposal of excavated soil as directed within a lead of 50 metres 35 laying of one number pvc insulated and pvc sheathed / xlpe power cable of 1.1 kv grade of following size in the existing rcc / hume / stoneware / gi pipe / hdpe / dwc pipe as required. upto 35 sq.mm 36 laying of one number pvc insulated and pvc sheathed / xlpe power cable of 1.1 kv grade of following size in the existing rcc / hume / stoneware / gi pipe / hdpe / dwc pipe as required. above 185 sq.mm and upto 400 sq.mm 37 laying of one number pvc insulated and pvc sheathed / xlpe power cable of 1.1 kv grade of following size in masonnary open ductetc as required. upto 35 sq.mm 38 laying of one number pvc insulated and pvc sheathed / xlpe power cable of 1.1 kv grade of following size in masonnary open ductetc as required. above 185 sq.mm and upto 400 sq.mm 39 laying and fixing of one number pvc insulated and pvc sheathed / xlpe power cable of 1.1 kv grade of following size on wall surface as required.upto 35 sq. mm ( clamped with 1mm thick saddle ) 40 providing and fixing of 50 mm dia g.i. pipe ( medium class ) in ground complete with g.i. fittings in existing trench etc as required. 41 providing, laying and fixing of 100 mm dia g.i. pipe ( medium class ) in ground complete with g.i. fittings in existing trench etc as required. 42 supplying and laying of 120 mm dia ( od 120 mm & id 103 mm nominal ) dwc hdpe pipe isi marked along with all accessories like socket, bend, couplers etc. conforming to is 14930, part ii complete with fitting and cutting, jointing etc. direct in ground ( 75 cm below ground level ) i / c excavation and refilling the trench but excluding sand cushioning and protective covering etc. complete as required.120 mm dia ( od 120 mm & id 103 mm nominal ) 43 supplying and making end termination with brass double compression gland and aluminium lugs for 31 / 2 x 300 sq.mm ( 70 mm ) size of pvc insulated and pvc sheathed / xlpe aluminium conductor cable of 1.1 kv grade as required. 44 supplying and making end termination with brass compression gland and aluminium lugs for 4 x 16 sq.mm ( 28 mm ) size of pvc insulated and pvc sheathed / xlpe copper conductor cable of 1.1 kv grade as required. 45 supply of 3½ x 300 sq.mm straight through joint with heat shrinkable kit including ferrules and other jointing materials for pvc insulated and pvc sheathed / xlpe aluminium conductor cable of 1.1 kv grade as required. 46 supplying and making cable route marker with cement concrete 1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone agreegate 20 mm nominal size ) of size 60 cm x 60 cm at the bottom and 50 cm x 50 cm at the top with a thicknes of 10 cm i / c inscription duly engraved as required. 47 design, fabrication, assembling, supply, installation, testingand commissioning of indoorpanel cubicle type made of 14swg crca sheet steel totally enclosed ip 42, free standing, floor mountedcompartmentalized with powder coated painting suitable for operation on 3phase, 415volts, 4wire50hzacsupplysystem as per specifications and drawings as required . i ) ( incomer ) a ) 200 a, 35 ka ( ics ) , 415v, four pole mccb withmicroprocessor release, frontoperatedrotaryhandle 02 nos. ii ) tpn spd, type 2, uc = 275 v, imax = 50 ka ( 8 / 20μs ) with isolating mcb & indicators = 02 nosiii ) auto transfer switch 200a, 4 pole 01no iv ) ( outgoing ) : a ) 160 a, 35 ka ( ics ) , 415v, four pole mccb withmicroprocessorrelease, frontoperatedrotaryhandle 01nos.b ) 63 a, 35 ka ( ics ) , 415v, four pole mccb withmicroprocessorrelease, frontoperatedrotaryhandle 03nos. c ) 200 amps tpn aluminium busbar. d ) necessary internal wiring &earthing strip as per speifications e ) rail mounted terminal connectors 2.5 sq.mm 14no.sf ) heavy duty power terminals for termination of outgoing cable suitable for 3.5x35 sq.mm al / cu cable. v ) metering / indicationa ) led indication lamps ( ryb ) with sp mcb protection = 2 sets. b ) digital multifunction meter, 3 phase, 5a, class 1 with tape insulated cts ( 200 / 5 ) = 02 set. c ) on offindication lamps ( led type ) 6 sets d ) mv power digital data logger for current, voltage etc. with at least 3 days record 01 no 48 earthing with g.i. earth plate 600 mm x 600 mm x 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal / coke and salt as required. 49 supplying and laying 25 mm x 5 mm gi strip at 0.50 meter below ground as strip earth electrode, including connection / terminating with nut, bolt, spring, washer etc. as required. ( jointing shall be done by overlapping and with 2 sets of brass nut bolt & spring washer spaced at 50 mm ) 50 providing and fixing 25 mm x 5 mm gi strip in 40 mm dia g.i. pipe from earth electrode including connection with brass nut, bolt, spring, washer excavation and re filling etc. as required. 51 providing and fixing 25 mm x 5 mm gi strip on surface or in recess for connections etc. as required. 52 supply of floor mounted water dispenser of flow rate 20 litres / hr hot, cold and normalsuitable for supply voltage of 230v single phase 53 providing and fixing following rating and breaking capacity mccb with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required. 200 a 36 ka four pole 54 supply of following size 1.1 kv grade xlpe insulated, pvc innersheathed, unarmoured copper conductor power cable conforming to is 7098 ( part 1 ) amended upto date. 4 x 4 sq.mm 55 supply & fixingof ledaviation obstacle fixture light low intensity type a steady red light output for night marking as per icao annexure 14, etc. as required. 56 supply & fixing weather proof junction boxes ( 130 mm x 180mmx 77 mm ) ip66 to including toaccommodate 5a ( 02 nos. ) & 15a ( 02nos. ) switch sockets etc. as required....

Military Engineer Services - Karnataka

35317564 certain e / m sanctioned works in sdi and aste under ge ( af ) marathahalli point wiring complete withmulti stranded copper wire size 1.5 sqmm insulated unsheathedfrlscabled cable 1100 voltsr conforming to is 694 drawn in and including non metalic rigid pvc conduit incl accessories surface type run on walls / ceiling incl ms terminal boxesmounted concealed on walls , includemetal box of suitable size and modlur white plate with frame fo mounting modlure switches, socket andregulators etc., incl provision of 1.5 sqmm frls pvc insulated multi stranded copper conductor cable as earth continuity conductor and connecting to common earth dolly, all as specified and as directed, 2 point wiring complete withmulti stranded copper wire size 2.5 sqmm insulated unsheathedfrlscabled cable 1100 voltsr conforming to is 694 drawn in and including non metalic rigid pvc conduit incl accessories surface type run on walls / ceiling incl ms terminal boxesmounted concealed on walls , includemetal box of suitable size and modlur white plate with frame fo mounting modlure switches, socket andregulators etc., incl provision of 2.5 sqmm frls pvc insulated multi stranded copper conductor cable as earth continuity conductor and connecting to common earth dolly, all as specified and as directed, 3 point wiring complete withmulti stranded copper wire size 4 sqmm insulated unsheathedfrlscabled cable 1100 voltsr conforming to is 694 drawn in and including non metalic rigid pvc conduit incl accessories surface type run on walls / ceiling incl ms terminal boxesmounted concealed on walls , includemetal box of suitable size and modlur white plate with frame fo mounting modlure switches, socket andregulators etc., incl provision of4 sqmm frls pvc insulated multi stranded copper conductor cable as earth continuity conductor and connecting to common earth dolly, all as specified and as directed, 4 taking down unservicable conventional fittings and supply & fixing in repairs led tube light fitting 1 x22 w, 220v ac decorative crcahousing box type with driver, holder including led tube light connecting upwith 3 core 0.5sqmm copper wire , hangingthe fittings from ceiling rose to required height as all as specified and as directed. 5 taking down unservicable conventional fittings and supply & fixing in repairs led tube light fitting 1 x20 w, 220v ac decorative crcahousing box type with driver, holder including led tube light connecting upwith 3 core 0.5sqmm copper wire between ceiling rose and fitting terminal all as specified and as directed. 6 taking down unservicable conventional fittings and supply & fixingin repair 600x600mm surface / recessed mounted ledlight fitting 36 / 35 w, glare freeuniform illuminationacrylic diffuser, connector block etc., complete with all accessoriesand including connecting up with 3 core 0.5sqmm copper wire between ceiling rose and fitting terminal complete all as specified and as directed. 7 , m& l for fixing stupe well glass 30watts 220v ac vertical hanging / horizontal / surface mounting pressure die alunminum casting aluminium well glass luminaires with high power led as source lightof 30 watts, 220v accomplete with driver, holder including ledlamp suitable for roof ceiling including connecting up with driver, three core flexiable copper conductor cable of suitable size from ceiling rose complete with all accessories as directed 8 taking down unservicableswitches and s&fmodular type one way 6 amps. 9 s&f mccb 3 pole mccb 3 pole .415 v. fixed type, 25 to 100 amps with breaking capacity 16 ka in existing panel 10 supply and fixingmcb db spn 8 way, double door, 240 v, ac, 11 supply and fixingmcb db spn 4way, double door, 240 v, ac, 12 supply and fixing mcb spn25 to 63 amps rating, 10 ka c curve240v, 50 hz ac completein dbs all as specified and as directed. 13 supply and fixingmcb spn 32 amps rating, 10 ka c curve240v, 50 hz ac complete in dbs all as specified and as directed. 14 supply and fixingmcb sp 5 to 32 amps rating, 10 ka c curve240v, 50 hz ac in dbs complete all as specified and as directed. 15 taking out old unserviceable ug cable including supply and laying 25 sqmm, 4 core lt ug cable grade pvc xlpe insulated, pvc sheathed armoured, heavy duty, in trenches / walls / poles / passing through pipes with multistranded aluminium conductor including lugs / thimbles / ferrules connection, testing and commissioning complete all as specified and as directed. 16 excavation in trenches not exc 1.5 mtr deep and not exc 1.5 mtr wide in loose / soft soil and getting out complete all as specified and as directed.. 17 returning and filling in, levelling watering and well ramming in layers not exc 25 cms thick each all as directed 18 removal of surplus soil to a distance not exc 50 mtr and depositing where as directed at a level n.exceeding 1.5 m above the starting point complete all as specified and as directed. 19 m / l for sand filling in trenches above and below the cable for protection complete all as specified and as directed. 20 m / l for laying old size sub class b bricks in trenches abovethe cable for protection 21 supplyand laying gi pipe light grade 50mm bore including necessary fittings for cable proctectionof ltcable iin trench / floor / post, as specified and directed by engineer in charge, 22 earthing complete with galvanised iron earth plate electrode600x600x6 mm as earthing lead buried directly in ground vertically to depth not less than 2.25 mtr below gl with the top edge of the platenot less than 1.5 mtr from gl, connectedto gi earth lead of 4.0mm dia, by means of bolts & nuts, to gi and connected to earthing test point all as shown inelecrical plate no 5 of ssrpart 1of 2009 * specified or indicated and testing on completion including excavation / earth work in any type of starta pcc ( 1:3:6 ) type c1 earthing chamber pre cast slab 50 mm thick in cement concrete ( 1 : 2 : 4 ) type b1 , reinforced with welded steel wire fabric ( xpm ) weight not less than 4 kg / sqm cast iron frame , funnel with wire mesh gi watering pipe of 20 mm bore medioum grade and lugs with and including gi earth wire 4 mm dia with gi proctection pipe of 15 mm medium grade 7.5 meter grade 7.5 meter long etc complete allas specified. 23 taking down old unservicable conventional fittings ands&f18 w ledutra bright led tube light ( opposite side connection with external led driver ) withvery high efficacysuited forinstalling in existing tube light g5 lamp holders to give glare free light with necessary wiringas required at site with own arrangement of ladder / or any arrangement to fix the light , testingafter completion of work, 24 taking down old unservicable conventional fittings and s&f ledlight fittingsmirror type with high output diffuser 2 feet , 10 watts 220 v ac decorativetype with driver, holder including led tube light connecting up with three core flexiable copper conductor cable of suitable size from ceiling rose complete with all accessories 25 taking down old unservicable conventional fittings , s&fled luminaires 600mmx600mm 35 / 36 watts 220v ac recessed type with high efficiency pmma diffuser soft glare free light complete with driver, holders &led lamp suitable for roof ceiling including connecting up three core flexiable copper conductor cable of suitable size complete all as specified &directed 26 suply & fix 110outer outer dia in mm, 3 layer pp r polypropylene random copolymer concealedpipes sdr 7.4 pipes sdr 7.4 ( pn16 ) uv stabilized and antimicrobial fusion welded having thermal stability for hot & cold water supply all pp r plain & brass threaded polypropylene random fittings laid in trenches .including repairingthe damaged road / hard standing as existing by cement concrete / asphaltic concreteas per specified and directed dy engr in charge , make : sfmc / kpt 27 suply & fix 63 mm, outer dia 3 layer pp r polypropylene random copolymer concealed pipes sdr 7.4 pipes sdr 7.4 ( pn16 ) uv stabilized and antimicrobial fusion welded having thermal stability for hot & cold water supply all pp r plain & brass threaded polypropylene random fittings laid in trenches and repairingthe damaged road / hard standing as existing by cement concrete / asphaltic concreteas per specified and directed dy engr in charge , make : sfmc / kpt 28 suply & fix 50 mm, out dia 3 layer pp r polypropylene random copolymer concealedpipes sdr 7.4 pipes sdr 7.4 ( pn16 ) uv stabilized and antimicrobial fusion welded having thermal stability for hot & cold water supply all pp r plain & brass threaded polypropylene random fittings laid in trenches and repairingthe damaged road / hard standing as existing by cement concrete / asphaltic concreteas per specified and directed dy engr in charge , make : sfmc / kpt 29 suply & fix 32 mm, outer dia 3 layer pp r polypropylene random copolymer concealedpipes sdr 7.4 pipes sdr 7.4 ( pn16 ) uv stabilized and antimicrobial fusion welded having thermal stability for hot & cold water supply all pp r plain & brass threaded polypropylene random fittings laid in trenches.and repairingthe damaged road / hard standing as existing by cement concrete / asphaltic concreteas per specified and directed dy engr in charge , make : sfmc / kpt 30 material and labour for dismantling the 150mm dia bore sluice insdi and reconditioning the sluice valve by replacing ss spindle, spindle nuts with brass ring, gland nuts rubber gasket required size and refixing, complete all as specified and as directed. 31 supply and fixing with all required materails / bolts& nuts / flange holes / rubber gasket as per site requirement ofcast iron heavy duty sluice valve with ci spindle conforming to is 14846: 2000 pn 1.6 of size100mm boreall as specified and as directed , make : kirloskar / leader / zoloto, 32 supply and fixing cast iron heavy duty non returnbutterflyvalveconforming to is 14846:of size 150mm bore including suitable size nuts, bolts, washer and rubber gasketall as specified and as directed , make : kirloskar / leader / l&t, 33 supply and fix 32 mm outer dia pp r gate valve brass insert as per requirement complete all as specified and as directed. make : sfmc / kpt / green fit, 34 supply and fix 63 mm outer dia pp r gatevalve brass insert as per requirement complete all as specified and as directed. make : sfmc / kpt / green fit, 35 supply and fix 150mm6 inches foot valve ci for sump inclusiveof fittings , fixtures & rubber gasket all as directed, make : kirloskar / leader / upadhyay, 36 material and labour for cleaning of under ground sump of capacity40, 000 gallons at sdi complete with the following : ( a ) cleaning of water tanks with high pressure water jet with pressure not exeeding 28kg / sqcm and remove all masses algae and dirt. ( b ) removal of dirty water alongwith sludge using sludge machines and disposal of the same to a safe distance. ( c ) scrubbing of floors using industrial vacuum cleaner. ( d ) applying of anti bacterial sterilization to walls floors and roofs of tanks. ( e ) testing of water shall be carried out after cleaning of tank and a certificate to this effect shall be submitted while claiming payment . ( f ) tank capacity and date of cleaning shall be marked on tanks neatly with oil paint all as directed by the eic. 37 material and labour for cleaning of oht of capacity40, 000 gallons at sdi complete with the following : ( a ) cleaning of water tanks with high pressure water jet with pressure not exeeding 28kg / sqcm and remove all masses algae and dirt. ( b ) removal of dirty water alongwith sludge using sludge machines and disposal of the same to a safe distance. ( c ) scrubbing of floors using industrial vacuum cleaner. ( d ) applying of anti bacterial sterilization to walls floors and roofs of tanks. ( e ) testing of water shall be carried out after cleaning of tank and a certificate to this effect shall be submitted while claiming payment . ( f ) tank capacity and date of cleaning shall be marked on tanks neatly with oil paint all as directed by the eic. 38 dismantling the existing broken valve chambers completely and material & labour forconstruction of new valve chamber having inner dimensions 900 mm x 900 mm x 900 mm with foundation pcc 1:4:8 type d2 using 40mm grade stone aggregate, brick work with sub class b old size build in cement mortar 1:6, pcc 1: 2: 4 type b1 using 20mm stone aggregate for coping, 15 mm thickrendering plaster in cm 1:4 including ms cover with locking arrangement all as specified and as directed. note: chamber covers will be measured and paid separately under relevant item of this schedule. 39 supply and fix of side add on aux. cotact blockas required no / nc at site for star delta starter motorall as directed 40 supply & fixdirect on line starter in sheet metal enclouser, ac 415v, 50 hz 3 ph of 7.5 kw 41 repairs & servicing ofdefective motorpump of capcity 10 to 15 hp by dismantling the pump & removing unserviceable parts, rewinding the motor including bearings, bushes, glandassemble the pump properly after replacements of unserviceable partspainting of motor , complete all as specified & as directed by engineer in charge, 42 material & labour for dismantling the delivery pipe lines of submersiable pump set from water mains, lifting / taking out carefully the gi column pipes upto 50mm dia, submersible cable defective submersible pump set from bore well transporting to workshop opening the pump set including repair / replacement of worn out parts , oling / greasing, lubricating the parts and reassembling, shifiting back to bore well after repair and lowering submersible pump set with agi column pipe 50mm dia / submersiable cable etc, in the depth upto 200 mtrs all as specified and directed by engineer in charge, note : the above quoted rates deemed to be inclusive for jointing of submersiable cable reconnecting the delivery pipe submersiable cable, reconnecting the delivery pipe lines ofsubmersible pump sets to water mains testing for satisfactory running & continuous flow of water 43 desiliting / cleaning of borewell including taking out and lowering of new / repaired submersible pump set of any size ( 5 hp to 17.5 hp ) , 3 phase 400 / 415 volts in 200 / 250 mm size tube well up to existing depth of bore comprising following nature of work. ( a ) dip connection existing pipe connection any size and removing electric connection. ( b ) errection of trapord / chain pulley block at site ( c ) unscrewing the submersible pump and removing the same at site for relowering. ( d ) transporting the trooly mounted dth machine at site for flushing the bore well / further boring if required. ( e ) flushing the bore hole through compressor operating 120psi after lowering the rig in length 1.5 mtr x 80 nos continuously till clear water in obtained not less than 8 hrs 44 supply & fixstar delta starterin sheet metal enclouser, ac 415v, 50 hz 3 ph of 7.5 kw 45 supply & fix flat three core pvc insulated 4 sqmm 3 core & pvc sheathed industrial cable for submersible pump motors 1100 volt, conforming to is 694 all as directed 46 s & f mcb tpn 40 / 63 amps incl making connections all as specified and directed.make havells or equivalent. make : havells or equivalent....

Indian Army - Karnataka

35152590 bids are invited for item no 1 of boq for providing services of electrician semiskilled 1 no per shift of 8 hours total 448 shifts , custom bid for services item no 2 of boq for providing services of helper unskilled 1 no per shift of 8 hours total 224 shifts , custom bid for services item no 3 of boq for providing services of electrician semi skilled per hour required in extra hours total 160 hours , custom bid for services item no 4 of boq for providing services of one helper unskilled per hour required in extra hours total 160 hours , custom bid for services item no 5 of boq for supply only pvc insulatedcopper conductor frls cable 1100 v grade 15 sqmm size total 180 rm , custom bid for services item no 6 of boq for supply only pvc insulatedcopper conductor frls cable 1100 v grade 25 sqmm size total 180 rm , custom bid for services item no 7 of boq for supply only pvc insulatedcopper conductor frls cable 1100 v grade 4 sqmm size total 180 rm , custom bid for services item no 8 of boq for supply only pvc insulatedcopper conductor frls cable 1100 v grade 6 sqmm size total 90 rm , custom bid for services item no 9 of boq for supply only pvc insulated flexible copper cable 3 core 2300052 of size frls grade total 90 rm , custom bid for services item no10 of boq for supply only rigid non metalic pvc conduit of size 25mm dia total 30 rm , custom bid for services item no 11 of boq for supply only rigid non metalic pvc conduit of size 20mm dia total 30 rm , custom bid for services item no 12 of boq for supply only pvc casingcaping of 25mm size total 80 rm , custom bid for services item no 13 of boq for supply only switch piano flush type 56 amps single pole 230 v oneway total 20 nos , custom bid for services item no 14 of boq for supply only switch socket combination 2 in 1 5 pin 5 amps 240 v flush type total 15 nos , custom bid for services item no 15 of boq for supply only socket outlet 5 pin 5 15 amps 240 v flush type total 15 nos , custom bid for services item no 16 of boq for supply only calling bell dingdong type working on ac 230 v single phase total 06 nos , custom bid for services item no 17 of boq for supply only bell push single pole flush type 230 v 5 amps total 04 nos , custom bid for services item no 18 of boq for supply only fan capacitor of 25 mfd for ceiling fan single phase 230 v total 30 nos , custom bid for services item bid number: gem / 2022 / b / 2819622 dated: 06 12 2022 bid document 1 / 53 item category phase 230 v total 30 nos , custom bid for services item no 19 of boq for supply only pvc ceiling rose three terminals white bakelite type total 10 nos , custom bid for services item no 20 of boq for supply only cfl 36 watt 4 pin total 50 nos , custom bid for services item no 21 of boq for supply only modular switch one way flush type 1 module 230 v 16 amps total 10 nos , custom bid for services item no 22 of boq for supply only modular socket 16 amps 2 moudle flush type 230v total 10 nos , custom bid for services item no 23 of boq for supply only modular socket one way 6 amps 1module 230v total 10 nos , custom bid for services item no 24 of boq for supply only bell push modular type 1 module ac 230v total 05 nos , custom bid for services item no 25 of boq for supply only modular fan regulator 220 w 2 module 230 v total 10 nos , custom bid for services item no 26 of boq for sf heavy duty automatic stardelta starter type ml15 fsld for pump set 10 hp total 02 nos , custom bid for services item no 27 of boq for supply only mcb sp 230 v 6 to 32 amps current rating c series 10 ka breaking capacity total 20 nos , custom bid for services item no 28 of boq for supply only mcb spn 230 v 10 to 32 amps current rating c series 10 ka breaking capacity total 10 nos , custom bid for services item no 29 of boq for supply only mcb spn 230 v 40 to 63 amps current rating c series 10 ka breaking capacity total 10 nos , custom bid for services item no 30 of boq for supply only mcb tpn 415 v 63 a current rating c series 10 ka breaking capacity total 6 nos , custom bid for services item no 31 of boq for supply only metal clad plug 2pe 20 amps 240 volts total 06 nos , custom bid for services item no 32 of boq for supply metal clad socket with cap chain 2pe 20 amps 240 volts total 06 nos , custom bid for services item no 33 of boq for supply only heavy duty capacitor for linear load 415 volts 50 hz of 25 kvar capacity total 06 nos , custom bid for services item no 34 of boq for supply only wall mounted battern type led light fitting 20 watt 4 ft length total 40 nos , custom bid for services item no 35 of boq for supply only wall mounted battern type led light fitting 10 watt 2 ft length total 20 nos , custom bid for services item no 36 of boq for s f led ceiling mounted recessed full lite luminaire light fittings with glare free uniform illumination 36 w 2x2 ft total 16 nos , custom bid for services item no 37 of boq for s f led surface mounted led flat panel luminaire light fittings with glare free uniform illumination 36 w 2x2 ft total 08 nos , custom bid for services item no 38 of boq for supply and fix outdoor type led post of lantern light fitting of 25 watts total 08 nos , custom bid for services item no 39 of boq for servicing of ht vcbs capacity 630800 amps complete total 01 job , custom bid for services item no 40 of boq for calibration of relays of ht 11 kv vcbocb through primary and secondary injection method total 02 jobs , custom bid for services item no 41 of boq for servicing of lt acbs capacity 630800 amps complete total 02 jobs , custom bid for services item no 42 of boq for supply and replacement of auxillary contact 10 a capacity suitable for acb 630800 amps with 2no 2nc coil voltage total 02 nos , custom bid for services item no 43 of boq for supply and replacement of shunt coil relay suitable for acb 630 a to 800 a 3 phase415 volt total 02 nos , custom bid for services item no 44 of boq for supply and replacement of under voltage relay suitable for acb 630 a to 800 amps 3 phase 415 volt total 02 nos , custom bid for services item no 45 of boq for supply and replacement of earth fault relay suitable for acb 630 a to 800 amps 3 phase 415 volt total 02 nos , custom bid for bid details 2 / 53 800 amps 3 phase 415 volt total 02 nos , custom bid for services item no 46 of boq for supply only mccb 4 pole 400amps 3536 ka breaking capacity50 hz 415 v ac thermal magnetic release trip unit total 01 no , custom bid for services item no 47 of boq for supply only mccb 4 pole 250 amps 3536 ka breaking capacity 50 hz 415 v ac thermal magnetic release trip unit total 02 nos , custom bid for services item no 48 of boq for supply only mccb 4 pole 200 amps 3536 ka breaking capacity 50 hz 415 v ac thermal magnetic release trip unit total 02 nos , custom bid for services item no 49 of boq for supply only mccb 3 pole 100 amps 16 ka breaking capacity 50 hz 415 v ac thermal magnetic release trip unit total 02 nos , custom bid for services item no 50 of boq for supply only mccb 4 pole 125 amps 16 ka breaking capacity 50 hz 415 v ac thermal magnetic release trip unit total 02 nos , custom bid for services item no 51 of boq for supply only mccb 3 pole 63 amps 16 ka breaking capacity 50 hz 415 v ac thermal magnetic release trip unit total 03 nos , custom bid for services item no 52 of boq for taking down supply and lay cable xlpe insulated armoured lt cable 1100 volts grade of size 10 sq mm 4 core total 150 rm , custom bid for services item no 53 of boq for taking down supply and lay cable xlpe insulated armoured lt cable 1100 volts grade of size 35 sq mm 35 core total 100 rm , custom bid for services item no 54 of boq for taking down supply and lay cable xlpe insulated armoured lt cable 1100 volts grade of size 50sq mm 35 core total 80 rm , custom bid for services item no 55 of boq for taking down supply and lay cable xlpe insulated armoured lt cable 1100 volts grade of size 70sq mm 35 core total 80 rm , custom bid for services item no 56 of boq for fabricate supply install test and commissioning of lt panel board indooroutdoor type 3 phase 4 wire made out of 2 mm ms sheet including all components specified in item 56 total 02 jobs , custom bid for services item no 57 of boq for supply and lay cable xlpe insulated armoured ht cable 11000 volts grade of size 120 sqmm 3 core total 60 rm , custom bid for services item no 58 of boq for ml for cable joining kit for 11 kv earthed grade cable for outdoor end termination heat shrink type joint for 3 core xlpe armoured aluminium conductor cable of size 120 sqmm total 06 nos , custom bid for services item no 59 of boq for excavation in trenches in hard dense soil not exceeding 15 metre wide not exceeding 15 metre in depth total 35 cum , custom bid for services item no 60 of boq for returning filling with excavated soil total 05 cum , custom bid for services item no 61 of boq for removing of excavated soil to a distance not exceeding 50 m depositing where as directed total 03 cum , custom bid for services item no 62 of boq for supply and lay riddled earth soil conforming is1255 for cushioning in layers for cables total 2 cum , custom bid for services item no 63 of boq for sl bricks sub class b of old size 230 mm x 115 mm x 75 mm laid in trenches for cable protection toatal 500 nos , custom bid for services item no 64 of boq for painting to steel surfaces of vcbs lt panel boards or feeder pillar boxes or any other plants total 250 sqm , custom bid for services item no 65 of boq for material and labour for topping up of transformer oil isi marked total 75 litres , custom bid for services item no 66 of boq for supply only selector switch for voltmeter suitable for ht 11 kv panel boards total 05 nos , custom bid for services item no 67 of boq for supply only selector switch for ammeter suitable for ht 11 kv panel boards total 05 nos , custom bid for services item no 68 of boq for supply only bid details 3 / 53 custom bid for services item no 68 of boq for supply only led type indicator lamps 3 phase with ryb colours set of 3 total 06 sets of three , custom bid for services item no 69 of boq for material and labour for earthing complete with galvanised steel earth plate electrode 600 mm x 600 mmx 630 mm using galvanised earth wire 4 mm dia all as specified in item description total 04 jobs...

Indian Army - Karnataka

34991897 bids are invited for custom bid for services item no 1 of boq for providing services of electrician semiskilled 1 no per shift of 8 hours total 448 shifts , custom bid for services item no 2 of boq for providing services of helper unskilled 1 no per shift of 8 hours total 224 shifts , custom bid for services item no 3 of boq for providing services of electrician semi skilled per hour required in extra hours total 160 hours , custom bid for services item no 4 of boq for providing services of one helper unskilled per hour required in extra hours total 160 hours , custom bid for services item no 5 of boq for supply only pvc insulatedcopper conductor frls cable 1100 v grade 15 sqmm size total 180 rm , custom bid for services item no 6 of boq for supply only pvc insulatedcopper conductor frls cable 1100 v grade 25 sqmm size total 180 rm , custom bid for services item no 7 of boq for supply only pvc insulatedcopper conductor frls cable 1100 v grade 4 sqmm size total 180 rm , custom bid for services item no 8 of boq for supply only pvc insulatedcopper conductor frls cable 1100 v grade 6 sqmm size total 90 rm , custom bid for services item no 9 of boq for supply only pvc insulated flexible copper cable 3 core 2300052 of size frls grade total 90 rm , custom bid for services item no10 of boq for supply only rigid non metalic pvc conduit of size 25mm dia total 30 rm , custom bid for services item no 11 of boq for supply only rigid non metalic pvc conduit of size 20mm dia total 30 rm , custom bid for services item no 12 of boq for supply only pvc casingcaping of 25mm size total 80 rm , custom bid for services item no 13 of boq for supply only switch piano flush type 56 amps single pole 230 v oneway total 20 nos , custom bid for services item no 14 of boq for supply only switch socket combination 2 in 1 5 pin 5 amps 240 v flush type total 15 nos , custom bid for services item no 15 of boq for supply only socket outlet 5 pin 5 15 amps 240 v flush type total 15 nos , custom bid for services item no 16 of boq for supply only calling bell dingdong type working on ac 230 v single phase total 06 nos , custom bid for services item no 17 of boq for supply only bell push single pole flush type 230 v 5 amps total 04 nos , custom bid for services item no 18 of boq for supply only fan capacitor of 25 mfd for ceiling fan single phase 230 v total 30 nos , custom bid for services item phase 230 v total 30 nos , custom bid for services item no 19 of boq for supply only pvc ceiling rose three terminals white bakelite type total 10 nos , custom bid for services item no 20 of boq for supply only cfl 36 watt 4 pin total 50 nos , custom bid for services item no 21 of boq for supply only modular switch one way flush type 1 module 230 v 16 amps total 10 nos , custom bid for services item no 22 of boq for supply only modular socket 16 amps 2 moudle flush type 230v total 10 nos , custom bid for services item no 23 of boq for supply only modular socket one way 6 amps 1module 230v total 10 nos , custom bid for services item no 24 of boq for supply only bell push modular type 1 module ac 230v total 05 nos , custom bid for services item no 25 of boq for supply only modular fan regulator 220 w 2 module 230 v total 10 nos , custom bid for services item no 26 of boq for sf heavy duty automatic stardelta starter type ml15 fsld for pump set 10 hp total 02 nos , custom bid for services item no 27 of boq for supply only mcb sp 230 v 6 to 32 amps current rating c series 10 ka breaking capacity total 20 nos , custom bid for services item no 28 of boq for supply only mcb spn 230 v 10 to 32 amps current rating c series 10 ka breaking capacity total 10 nos , custom bid for services item no 29 of boq for supply only mcb spn 230 v 40 to 63 amps current rating c series 10 ka breaking capacity total 10 nos , custom bid for services item no 30 of boq for supply only mcb tpn 415 v 63 a current rating c series 10 ka breaking capacity total 6 nos , custom bid for services item no 31 of boq for supply only metal clad plug 2pe 20 amps 240 volts total 06 nos , custom bid for services item no 32 of boq for supply metal clad socket with cap chain 2pe 20 amps 240 volts total 06 nos , custom bid for services item no 33 of boq for supply only heavy duty capacitor for linear load 415 volts 50 hz of 25 kvar capacity total 06 nos , custom bid for services item no 34 of boq for supply only wall mounted battern type led light fitting 20 watt 4 ft length total 40 nos , custom bid for services item no 35 of boq for supply only wall mounted battern type led light fitting 10 watt 2 ft length total 20 nos , custom bid for services item no 36 of boq for s f led ceiling mounted recessed full lite luminaire light fittings with glare free uniform illumination 36 w 2x2 ft total 16 nos , custom bid for services item no 37 of boq for s f led surface mounted led flat panel luminaire light fittings with glare free uniform illumination 36 w 2x2 ft total 08 nos , custom bid for services item no 38 of boq for supply and fix outdoor type led post of lantern light fitting of 25 watts total 08 nos , custom bid for services item no 39 of boq for servicing of ht vcbs capacity 630800 amps complete total 01 job , custom bid for services item no 40 of boq for calibration of relays of ht 11 kv vcbocb through primary and secondary injection method total 02 jobs , custom bid for services item no 41 of boq for servicing of lt acbs capacity 630800 amps complete total 02 jobs , custom bid for services item no 42 of boq for supply and replacement of auxillary contact 10 a capacity suitable for acb 630800 amps with 2no 2nc coil voltage total 02 nos , custom bid for services item no 43 of boq for supply and replacement of shunt coil relay suitable for acb 630 a to 800 a 3 phase415 volt total 02 nos , custom bid for services item no 44 of boq for supply and replacement of under voltage relay suitable for acb 630 a to 800 amps 3 phase 415 volt total 02 nos , custom bid for services item no 45 of boq for supply and replacement of earth fault relay suitable for acb 630 a to 800 amps 3 phase 415 volt total 02 nos , custom bid for services item no 46 of boq for supply only mccb 4 pole 400amps 3536 ka breaking capacity50 hz 415 v ac thermal magnetic release trip unit total 01 no , custom bid for services item no 47 of boq for supply only mccb 4 pole 250 amps 3536 ka breaking capacity 50 hz 415 v ac thermal magnetic release trip unit total 02 nos , custom bid for services item no 48 of boq for supply only mccb 4 pole 200 amps 3536 ka breaking capacity 50 hz 415 v ac thermal magnetic release trip unit total 02 nos , custom bid for services item no 49 of boq for supply only mccb 3 pole 100 amps 16 ka breaking capacity 50 hz 415 v ac thermal magnetic release trip unit total 02 nos , custom bid for services item no 50 of boq for supply only mccb 4 pole 125 amps 16 ka breaking capacity 50 hz 415 v ac thermal magnetic release trip unit total 02 nos , custom bid for services item no 51 of boq for supply only mccb 3 pole 63 amps 16 ka breaking capacity 50 hz 415 v ac thermal magnetic release trip unit total 03 nos , custom bid for services item no 52 of boq for taking down supply and lay cable xlpe insulated armoured lt cable 1100 volts grade of size 10 sq mm 4 core total 150 rm , custom bid for services item no 53 of boq for taking down supply and lay cable xlpe insulated armoured lt cable 1100 volts grade of size 35 sq mm 35 core total 100 rm , custom bid for services item no 54 of boq for taking down supply and lay cable xlpe insulated armoured lt cable 1100 volts grade of size 50sq mm 35 core total 80 rm , custom bid for services item no 55 of boq for taking down supply and lay cable xlpe insulated armoured lt cable 1100 volts grade of size 70sq mm 35 core total 80 rm , custom bid for services item no 56 of boq for fabricate supply install test and commissioning of lt panel board indooroutdoor type 3 phase 4 wire made out of 2 mm ms sheet including all components specified in item 56 total 02 jobs , custom bid for services item no 57 of boq for supply and lay cable xlpe insulated armoured ht cable 11000 volts grade of size 120 sqmm 3 core total 60 rm , custom bid for services item no 58 of boq for ml for cable joining kit for 11 kv earthed grade cable for outdoor end termination heat shrink type joint for 3 core xlpe armoured aluminium conductor cable of size 120 sqmm total 06 nos , custom bid for services item no 59 of boq for excavation in trenches in hard dense soil not exceeding 15 metre wide not exceeding 15 metre in depth total 35 cum , custom bid for services item no 60 of boq for returning filling with excavated soil total 05 cum , custom bid for services item no 61 of boq for removing of excavated soil to a distance not exceeding 50 m depositing where as directed total 03 cum , custom bid for services item no 62 of boq for supply and lay riddled earth soil conforming is1255 for cushioning in layers for cables total 2 cum , custom bid for services item no 63 of boq for sl bricks sub class b of old size 230 mm x 115 mm x 75 mm laid in trenches for cable protection toatal 500 nos , custom bid for services item no 64 of boq for painting to steel surfaces of vcbs lt panel boards or feeder pillar boxes or any other plants total 250 sqm , custom bid for services item no 65 of boq for material and labour for topping up of transformer oil isi marked total 75 litres , custom bid for services item no 66 of boq for supply only selector switch for voltmeter suitable for ht 11 kv panel boards total 05 nos , custom bid for services item no 67 of boq for supply only selector switch for ammeter suitable for ht 11 kv panel boards total 05 nos , custom bid for services item no 68 of boq for supply only custom bid for services item no 68 of boq for supply only led type indicator lamps 3 phase with ryb colours set of 3 total 06 sets of three , custom bid for services item no 69 of boq for material and labour for earthing complete with galvanised steel earth plate electrode 600 mm x 600 mmx 630 mm using galvanised earth wire 4 mm dia all as specified in item description total 04 jobs...

Rural Development Panchayath Raj Engineering Department - Karnataka

34503078 tender for turuvekere taluk package no: tmk tvk 46 / 22 23 1 civil work: earth work excavation by manual means for drains, canals, waste weir, draft, approach channels, key trenches, foundation of bridges and such simillar works in all kinds of soils , as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m including cost of labour, tools & other appurtenaces required to complete the work. in all kinds of soils depth upto 1.5 m with all lead and lift, loading & unloading, hire charges of machinery and equipments, transportation charges cost and conveyance of all materials, labour charges and all other incidental charges etc., complete as per standard technical detailed specification and design and directions of the engineer incharge of the work ( 1 ) 46.93 ( 2 ) 46.93 ( 3 ) 46.93 ( 4 ) 46.93 ( 5 ) 46.93 ( 6 ) 46.93 ( 7 ) 46.93 cum 328.51 2 filling available excavated earth ( excluding rock ) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering with all lead and lift, loading & unloading, hire charges of machinery and equipments, transportation charges cost and conveyance of all materials, labour charges and all other incidental charges etc., complete as per standard technical detailed specification and design and directions of the engineer incharge of the work ( 1 ) 32.85 ( 2 ) 32.85 ( 3 ) 32.85 ( 4 ) 32.85 ( 5 ) 32.85 ( 6 ) 32.85 ( 7 ) 32.85 cum 229.95 3 providing and laying in position plain cement concrete for levelling course for all works in foundation. the granite / trap / basalt crushed graded coarse aggregates and fine aggregates as per relevant is codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. ( the cost of steel reinforcement & formwork shall be paid separately ) mix 1:4:8 ( m5 ) using 40 mm nominal size graded crushed coarse aggregates with all lead and lift, loading & unloading, hire charges of machinery and equipments, transportation charges cost and conveyance of all materials, labour charges and all other incidental charges etc., complete as per standard technical detailed specification and design and directions of the engineer incharge of the work ( 1 ) 11.67 ( 2 ) 11.67 ( 3 ) 11.67 ( 4 ) 11.67 ( 5 ) 11.67 ( 6 ) 11.67 ( 7 ) 11.67 cum 81.69 4 providing random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 ( 1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size ) upto plinth level with : cement mortar 1:6 ( 1 cement : 6 coarse sand ) with all lead and lift, loading & unloading, hire charges of machinery and equipments, transportation charges cost and conveyance of all materials, labour charges and all other incidental charges etc., complete as per standard technical detailed specification and design and directions of the engineer incharge of the work ( 1 ) 12.12 ( 2 ) 12.12 ( 3 ) 12.12 ( 4 ) 12.12 ( 5 ) 12.12 ( 6 ) 12.12 ( 7 ) 12.12 cum 84.84 5 providing coursed rubble masonry ( second sort ) with hard stone in foundation & plinth with cement mortar 1:6 ( 1 cement : 6 coarse sand ) with all lead and lift, loading & unloading, hire charges of machinery and equipments, transportation charges cost and conveyance of all materials, labour charges and all other incidental charges etc., complete as per standard technical detailed specification and design and directions of the engineer incharge of the work ( 1 ) 6.84 ( 2 ) 6.84 ( 3 ) 6.84 ( 4 ) 6.84 ( 5 ) 6.84 ( 6 ) 6.84 ( 7 ) 6.84 cum 47.88 6 appendix i – additionalities for formwork, centering 1. foundation upto plinth a ) isolated 8% with all lead and lift, loading & unloading, hire charges of machinery and equipments, transportation charges cost and conveyance of all materials, labour charges and all other incidental charges etc., complete as per standard technical detailed specification and design and directions of the engineer incharge of the work ( 1 ) 17.81 ( 2 ) 17.81 ( 3 ) 17.81 ( 4 ) 17.81 ( 5 ) 17.81 ( 6 ) 17.81 ( 7 ) 17.81 cum 124.67 7 providing and laying in position reinforced cement concrete for all foundation works. the granite / trap / basalt crushed graded coarse aggregates and fine aggregates as per relevant is codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant is codes , labour, usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. ( the cost of steel reinforcement & formwork to be paid separately ) m20 design mix using 20 mm nominal size graded crushed coarse with all lead and lift, loading & unloading, hire charges of machinery and equipments, transportation charges cost and conveyance of all materials, labour charges and all other incidental charges etc., complete as per standard technical detailed specification and design and directions of the engineer incharge of the work ( 1 ) 17.81 ( 2 ) 17.81 ( 3 ) 17.81 ( 4 ) 17.81 ( 5 ) 17.81 ( 6 ) 17.81 ( 7 ) 17.81 cum 124.67 8 appendix i – additionalities for formwork, centering 8. columns & piers 10%with all lead and lift, loading & unloading, hire charges of machinery and equipments, transportation charges cost and conveyance of all materials, labour charges and all other incidental charges etc., complete as per standard technical detailed specification and design and directions of the engineer incharge of the work ( 1 ) 4.17 ( 2 ) 4.17 ( 3 ) 4.17 ( 4 ) 4.17 ( 5 ) 4.17 ( 6 ) 4.17 ( 7 ) 4.17 cum 29.19 9 appendix i – additionalities for formwork, centering 12. beams & lintels of building 20% 13. roof ( straight & arched ) 20% with all lead and lift, loading & unloading, hire charges of machinery and equipments, transportation charges cost and conveyance of all materials, labour charges and all other incidental charges etc., complete as per standard technical detailed specification and design and directions of the engineer incharge of the work ( 1 ) 15.13 ( 2 ) 15.13 ( 3 ) 15.13 ( 4 ) 15.13 ( 5 ) 15.13 ( 6 ) 15.13 ( 7 ) 15.13 cum 105.91 10 providing thermo mechanically treated bars of grade fe 550d or more steel reinforcement for r.c.c. work including straightening, cutting, bending, placing in position, binding and anchoring to adjacent members whereever necessary complete as per design including cost of material, labour, usage charges complete as per specifications. ( the laps and wastages shall not be measured separately ) with all lead and lift, loading & unloading, hire charges of machinery and equipments, transportation charges cost and conveyance of all materials, labour charges and all other incidental charges etc., complete as per standard technical detailed specification and design and directions of the engineer incharge of the work ( 1 ) 2720.00 ( 2 ) 2720.00 ( 3 ) 2720.00 ( 4 ) 2720.00 ( 5 ) 2720.00 ( 6 ) 2720.00 ( 7 ) 2720.00 kg 19040 11 providing and laying in position reinforced cement concrete for all super structures of building , road works, water works, irrigation works & super structure works of bridges upto 3.50 m height. the granite / trap / basalt crushed graded coarse aggregates and fine aggregates as per relevant is codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. the cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant is codes , labour, usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. ( the cost of steel reinforcement, dowel bars & formwork to be paid separately ) m20 design mix using 20 mm nominal size graded crushed coarse aggregates with all lead and lift, loading & unloading, hire charges of machinery and equipments, transportation charges cost and conveyance of all materials, labour charges and all other incidental charges etc., complete as per standard technical detailed specification and design and directions of the engineer incharge of the work ( 1 ) 20.65 ( 2 ) 20.65 ( 3 ) 20.65 ( 4 ) 20.65 ( 5 ) 20.65 ( 6 ) 20.65 ( 7 ) 20.65 cum 144.55 12 ksrb 4.2.10 : providing and laying in position reinforced cement concrete of design mix m20 with opc cement @ 24kgs, with 2mm and down size graded granite metal coares aggregates @ 0.5175cum and fine aggregates @ 0.345cum, with superplastisiser @ 0.225lts, machine mixed, well compacted for plain chajja of 7.5cms average thickness, upto ground floor level including cost of all materials, labour, hom of machinery, curing, complete as per specifications. specification no. kbs 4.1, 4.6 with all lead and lift, loading & unloading, hire charges of machinery and equipments, transportation charges cost and conveyance of all materials, labour charges and all other incidental charges etc., complete as per standard technical detailed specification and design and directions of the engineer incharge of the work ( 1 ) 2.16 ( 2 ) 2.16 ( 3 ) 2.16 ( 4 ) 2.16 ( 5 ) 2.16 ( 6 ) 2.16 ( 7 ) 2.16 sqm 15.12 13 providing brick work with common burnt clay non modular bricks of class designation 3.5 in foundation and plinth in cement mortar 1:4 ( 1 cement : 4 coarse sand ) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work. with all lead and lift, loading & unloading, hire charges of machinery and equipments, transportation charges cost and conveyance of all materials, labour charges and all other incidental charges etc., complete as per standard technical detailed specification and design and directions of the engineer incharge of the work ( 1 ) 24.68 ( 2 ) 24.68 ( 3 ) 24.68 ( 4 ) 24.68 ( 5 ) 24.68 ( 6 ) 24.68 ( 7 ) 24.68 cum 172.76 14 providing 12 mm cement plaster with cement mortar 1:4 ( 1 cement: 4 fine sand ) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of engineer in charge. with all lead and lift, loading & unloading, hire charges of machinery and equipments, transportation charges cost and conveyance of all materials, labour charges and all other incidental charges etc., complete as per standard technical detailed specification and design and directions of the engineer incharge of the work ( 1 ) 44.46 ( 2 ) 44.46 ( 3 ) 44.46 ( 4 ) 44.46 ( 5 ) 44.46 ( 6 ) 44.46 ( 7 ) 44.46 sqm 311.22 15 providing 15 mm cement plaster on the rough side of single or half brick wall of mix 1:4 ( 1 cement: 4 fine sand ) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of engineer in charge. with all lead and lift, loading & unloading, hire charges of machinery and equipments, transportation charges cost and conveyance of all materials, labour charges and all other incidental charges etc., complete as per standard technical detailed specification and design and directions of the engineer incharge of the work ( 1 ) 58.28 ( 2 ) 58.28 ( 3 ) 58.28 ( 4 ) 58.28 ( 5 ) 58.28 ( 6 ) 58.28 ( 7 ) 58.28 sqm 407.96 16 providing 20 mm cement plaster of mix :1:4 ( 1 cement: 4 fine sand ) to brick / stone masonary including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of engineer in charge. with all lead and lift, loading & unloading, hire charges of machinery and equipments, transportation charges cost and conveyance of all materials, labour charges and all other incidental charges etc., complete as per standard technical detailed specification and design and directions of the engineer incharge of the work ( 1 ) 171.64 ( 2 ) 171.64 ( 3 ) 171.64 ( 4 ) 171.64 ( 5 ) 171.64 ( 6 ) 171.64 ( 7 ) 171.64 sqm 1201.48 17 flooring with 25mm thick polished tandur blue stone slabs using cement mortar 1:6, 25mm thick over existing cement concrete bed or top of roof laid to line and level and jointed with cement slurry mixed with pigment to match the shade of the slab, , including cost of materials, labour, curing, polishing complete as per specifications. with all lead and lift, loading & unloading, hire charges of machinery and equipments, transportation charges cost and conveyance of all materials, labour charges and all other incidental charges etc., complete as per standard technical detailed specification and design and directions of the engineer incharge of the work ( 1 ) 58.79 ( 2 ) 58.79 ( 3 ) 58.79 ( 4 ) 58.79 ( 5 ) 58.79 ( 6 ) 58.79 ( 7 ) 58.79 sqm 411.53 18 finishing walls with acrylic smooth exterior paint of required shade :new work ( two coat applied @ 1.67 ltr / 10 m� over and including priming coat of exterior primer applied @ 2.20 kg / 10 m� ) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of engineer in charge. with all lead and lift, loading & unloading, hire charges of machinery and equipments, transportation charges cost and conveyance of all materials, labour charges and all other incidental charges etc., complete as per standard technical detailed specification and design and directions of the engineer incharge of the work ( 1 ) 102.74 ( 2 ) 102.74 ( 3 ) 102.74 ( 4 ) 102.74 ( 5 ) 102.74 ( 6 ) 102.74 ( 7 ) 102.74 sqm 719.18 19 providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of engineer in charge. with all lead and lift, loading & unloading, hire charges of machinery and equipments, transportation charges cost and conveyance of all materials, labour charges and all other incidental charges etc., complete as per standard technical detailed specification and design and directions of the engineer incharge of the work ( 1 ) 58.79 ( 2 ) 58.79 ( 3 ) 58.79 ( 4 ) 58.79 ( 5 ) 58.79 ( 6 ) 58.79 ( 7 ) 58.79 sqm 411.53 20 wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade :two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of engineer in charge. with all lead and lift, loading & unloading, hire charges of machinery and equipments, transportation charges cost and conveyance of all materials, labour charges and all other incidental charges etc., complete as per standard technical detailed specification and design and directions of the engineer incharge of the work ( 1 ) 58.79 ( 2 ) 58.79 ( 3 ) 58.79 ( 4 ) 58.79 ( 5 ) 58.79 ( 6 ) 58.79 ( 7 ) 58.79 sqm 411.53 21 providing and fixing 1mm thick m.s. sheet door with frame of 40x40x6 mm angle iron and 3 mm m.s. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. using m.s. angels 40x40x6 mm for diagonal braces including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the engineer in charge. with all lead and lift, loading & unloading, hire charges of machinery and equipments, transportation charges cost and conveyance of all materials, labour charges and all other incidental charges etc., complete as per standard technical detailed specification and design and directions of the engineer incharge of the work ( 1 ) 2.52 ( 2 ) 2.52 ( 3 ) 2.52 ( 4 ) 2.52 ( 5 ) 2.52 ( 6 ) 2.52 ( 7 ) 2.52 sqm 17.64 22 providing and fixing factory made isi marked steel glazed doors, windows and ventilators, side / top / centre hung, with beading and all members such as f7d, f4b, k11 b and k12 b etc. complete of standard rolled steel sections, joints mitred and flash butt welded and sash bars tenoned and riveted, including providing and fixing of hinges, pivots, including priming coat of approved steel primer, but excluding the cost of other fittings, complete all as per approved design, ( sectional weight of only steel members shall be measured for payment ) . with all lead and lift, loading & unloading, hire charges of machinery and equipments, transportation charges cost and conveyance of all materials, labour charges and all other incidental charges etc., complete as per standard technical detailed specification and design and directions of the engineer incharge of the work ( 1 ) 120.96 ( 2 ) 120.96 ( 3 ) 120.96 ( 4 ) 120.96 ( 5 ) 120.96 ( 6 ) 120.96 ( 7 ) 120.96 kg 846.72 23 painting steel work with deluxe multi surface paint to give an even shade. two coat applied @ 0.90 ltr / 10 m� over an under coat of primer applied @ 0.80 ltr / 10 m� of approved brand and manufacture including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of engineer in charge. with all lead and lift, loading & unloading, hire charges of machinery and equipments, transportation charges cost and conveyance of all materials, labour charges and all other incidental charges etc., complete as per standard technical detailed specification and design and directions of the engineer incharge of the work ( 1 ) 36.63 ( 2 ) 36.63 ( 3 ) 36.63 ( 4 ) 36.63 ( 5 ) 36.63 ( 6 ) 36.63 ( 7 ) 36.63 sqm 256.41 24 providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approved steel primer. m.s. tube including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the engineerin charge.with all lead and lift, loading & unloading, hire charges of machinery and equipments, transportation charges cost and conveyance of all materials, labour charges and all other incidental charges etc., complete as per standard technical detailed specification and design and directions of the engineer incharge of the work ( 1 ) 105.00 ( 2 ) 105.00 ( 3 ) 105.00 ( 4 ) 105.00 ( 5 ) 105.00 ( 6 ) 105.00 ( 7 ) 105.00 kg 735 25 providing and fixing on wall face unplasticised rigid pvc rain water pipes conforming to is : 13592 type a, including jointing with seal ring conforming to is : 5382 leaving 10 mm gap for thermal exxpansion ( i ) single socketed pipe 100 mm diameter with all lead and lift, loading & unloading, hire charges of machinery and equipments, transportation charges cost and conveyance of all materials, labour charges and all other incidental charges etc., complete as per standard technical detailed specification and design and directions of the engineer incharge of the work ( 1 ) 9.00 ( 2 ) 9.00 ( 3 ) 9.00 ( 4 ) 9.00 ( 5 ) 9.00 ( 6 ) 9.00 ( 7 ) 9.00 mtr 63 26 providing and laying water proofing treatment to the roof with pu based single component elastomeric pure polyurethane based coating on new terrace / chajjas / sunken portion of wc:bathroom, cold applied pu waterproofing membrane that is highly elastic with elongation greater than 400% and tensile strength greater than 2mpa as per astm d412. the waterproofing membrane to be applied in 2coats @ 1.6kg per m2 to achieve final dft ( dry film thickness ) of 1mm including prime coat of epoxy primer @150 g per m2 and protection with 120gsm geo textile over the waterproofing membrane. the finished cost to include surface preparation, making coving at junction, bore packing, treatment of construction joints completely as per specification & with a 10 years warranty on product & work from certified manufacturers as per the direction of the engineer in charge.with all lead and lift, loading & unloading, hire charges of machinery and equipments, transportation charges cost and conveyance of all materials, labour charges and all other incidental charges etc., complete as per standard technical detailed specification and design and directions of the engineer incharge of the work ( 1 ) 49.47 ( 2 ) 49.47 ( 3 ) 49.47 ( 4 ) 49.47 ( 5 ) 49.47 ( 6 ) 49.47 ( 7 ) 49.47 sqm 346.29 27 providing wall black boards in cm 1:3 with two coats of black paint including finishing etc., complete. with all lead and lift, loading & unloading, hire charges of machinery and equipments, transportation charges cost and conveyance of all materials, labour charges and all other incidental charges etc., complete as per standard technical detailed specification and design and directions of the engineer incharge of the work ( 1 ) 3.00 ( 2 ) 3.00 ( 3 ) 3.00 ( 4 ) 3.00 ( 5 ) 3.00 ( 6 ) 3.00 ( 7 ) 3.00 sqm 21 28 electrification: supplying heavy gauge pvc conduit pipe ...... mm dia..........mm thick confirming to is 2509 with suitable size bends, metal / pvc junction boxes, adhesive paste etc., and running before concreting the slab. the conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using pvc end enclosures, run with 18swg gi fish wire wherever necessary 19 / 20 mm dia 2 mm thick with all lead and lift, loading & unloading, hire charges of machinery and equipments, transportation charges cost and conveyance of all materials, labour charges and all other incidental charges etc., complete as per standard technical detailed specification and design and directions of the engineer incharge of the work ( 1 ) 30.00 ( 2 ) 30.00 ( 3 ) 30.00 ( 4 ) 30.00 ( 5 ) 30.00 ( 6 ) 30.00 ( 7 ) 30.00 mtr 210 29 upplying heavy gauge pvc conduit pipe .... dia ....... mm thick with suitable size bends, metal junction boxes adhesive paste etc., by groove cutting in the wall and fixing by bracing u or j hooks and cement plastering upto the wall surface and run with 18 swg gi fish wire run throughout the conduit wherever necessary 19 / 20 mm dia 2 mm thick with all lead and lift, loading & unloading, hire charges of machinery and equipments, transportation charges cost and conveyance of all materials, labour charges and all other incidental charges etc., complete as per standard technical detailed specification and design and directions of the engineer incharge of the work ( 1 ) 20.00 ( 2 ) 20.00 ( 3 ) 20.00 ( 4 ) 20.00 ( 5 ) 20.00 ( 6 ) 20.00 ( 7 ) 20.00 mtr 140 30 supplying and fixing sheet metal box made out of 18 swg sheet metal with necessary holes for cable / conduit entry as required with one coat of primer of approved make etc.135 x 75 x 65 mm with all lead and lift, loading & unloading, hire charges of machinery and equipments, transportation charges cost and conveyance of all materials, labour charges and all other incidental charges etc., complete as per standard technical detailed specification and design and directions of the engineer incharge of the work ( 1 ) 2 ( 2 ) 2 ( 3 ) 2 ( 4 ) 2 ( 5 ) 2 ( 6 ) 2 ( 7 ) 2 each 14 31 supplying and fixing sheet metal box made out of 18 swg sheet metal with necessary holes for cable / conduit entry as required with one coat of primer of approved make etc. 200 x 200 x 65 mm with all lead and lift, loading & unloading, hire charges of machinery and equipments, transportation charges cost and conveyance of all materials, labour charges and all other incidental charges etc., complete as per standard technical detailed specification and design and directions of the engineer incharge of the work ( 1 ) 1 ( 2 ) 1 ( 3 ) 1 ( 4 ) 1 ( 5 ) 1 ( 6 ) 1 ( 7 ) 1 each 7 32 supplying and fixing pvc / metal conduit deep junction box 32 mm deep junction box with all lead and lift, loading & unloading, hire charges of machinery and equipments, transportation charges cost and conveyance of all materials, labour charges and all other incidental charges etc., complete as per standard technical detailed specification and design and directions of the engineer incharge of the work ( 1 ) 7 ( 2 ) 7 ( 3 ) 7 ( 4 ) 7 ( 5 ) 7 ( 6 ) 7 ( 7 ) 7 each 49 33 supplying and fixing metal fan box with round hook. with all lead and lift, loading & unloading, hire charges of machinery and equipments, transportation charges cost and conveyance of all materials, labour charges and all other incidental charges etc., complete as per standard technical detailed specification and design and directions of the engineer incharge of the work ( 1 ) 7 ( 2 ) 7 ( 3 ) 7 ( 4 ) 7 ( 5 ) 7 ( 6 ) 7 ( 7 ) 7 each 49 34 supplying and wiring adopting loop system in existing pvc conduit / casing capping casing capping using 2x1.5mm2 ( phase & neutral ) & 1x1.0 mm2 ( earth wire ) frls multi strand pvc insulated copper wire ( confirming to is 694: and latest amendments ) without control switch shall be fixed on the existing plastic sheet / gang box, the other end of the wires shall be terminated with sufficient loose length in a wood / pvc round block. complete for each outlet. medium point above 3m upto 6m from tapping point to out let via switch box with all lead and lift, loading & unloading, hire charges of machinery and equipments, transportation charges cost and conveyance of all materials, labour charges and all other incidental charges etc., complete as per standard technical detailed specification and design and directions of the engineer incharge of the work ( 1 ) 10 ( 2 ) 10 ( 3 ) 10 ( 4 ) 10 ( 5 ) 10 ( 6 ) 10 ( 7 ) 10 point 70 35 wiring for lighting / power circuit using one of frls pvc insulated 1100v grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified is 694:confirming to latest amendments. 1.5 mm2 with all lead and lift, loading & unloading, hire charges of machinery and equipments, transportation charges cost and conveyance of all materials, labour charges and all other incidental charges etc., complete as per standard technical detailed specification and design and directions of the engineer incharge of the work ( 1 ) 20.00 ( 2 ) 20.00 ( 3 ) 20.00 ( 4 ) 20.00 ( 5 ) 20.00 ( 6 ) 20.00 ( 7 ) 20.00 mtr 140 36 supplying and drawing flexible multicore cable manufactured with electrolytic grade flexible copper with low conductor confirming to is 8130 1984 and ( virgin ) pvc insulation sheathed suitable for working voltage upto 1100v as per is694:2010 3c x 4 mm2 with all lead and lift, loading & unloading, hire charges of machinery and equipments, transportation charges cost and conveyance of all materials, labour charges and all other incidental charges etc., complete as per standard technical detailed specification and design and directions of the engineer incharge of the work ( 1 ) 30.00 ( 2 ) 30.00 ( 3 ) 30.00 ( 4 ) 30.00 ( 5 ) 30.00 ( 6 ) 30.00 ( 7 ) 30.00 mtr 210 37 supplying and fixing surface / flush mounting unbreakable pvc modular box suitable for mounting modular switch plates with due groove cutting in brick / c.c wall, including necessary rawl plugs, machine / nf screws etc., complete. 6 way with all lead and lift, loading & unloading, hire charges of machinery and equipments, transportation charges cost and conveyance of all materials, labour charges and all other incidental charges etc., complete as per standard technical detailed specification and design and directions of the engineer incharge of the work ( 1 ) 2 ( 2 ) 2 ( 3 ) 2 ( 4 ) 2 ( 5 ) 2 ( 6 ) 2 ( 7 ) 2 each 14 38 supplying and fixing surface / flush mounting unbreakable pvc modular box suitable for mounting modular switch plates with due groove cutting in brick / c.c wall, including necessary rawl plugs, machine / nf screws etc., complete. 16 18 way with all lead and lift, loading & unloading, hire charges of machinery and equipments, transportation charges cost and conveyance of all materials, labour charges and all other incidental charges etc., complete as per standard technical detailed specification and design and directions of the engineer incharge of the work ( 1 ) 1 ( 2 ) 1 ( 3 ) 1 ( 4 ) 1 ( 5 ) 1 ( 6 ) 1 ( 7 ) 1 each 7 39 supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal / pvc box 6 way with all lead and lift, loading & unloading, hire charges of machinery and equipments, transportation charges cost and conveyance of all materials, labour charges and all other incidental charges etc., complete as per standard technical detailed specification and design and directions of the engineer incharge of the work ( 1 ) 2 ( 2 ) 2 ( 3 ) 2 ( 4 ) 2 ( 5 ) 2 ( 6 ) 2 ( 7 ) 2 each 14 40 supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal / pvc box 16 18 way with all lead and lift, loading & unloading, hire charges of machinery and equipments, transportation charges cost and conveyance of all materials, labour charges and all other incidental charges etc., complete as per standard technical detailed specification and design and directions of the engineer incharge of the work ( 1 ) 1 ( 2 ) 1 ( 3 ) 1 ( 4 ) 1 ( 5 ) 1 ( 6 ) 1 ( 7 ) 1 each 7 41 supplying and fixing of modular switch & connected accessories on existing modular switch plate as per is 3854 and is 1293. 6a one way switch with all lead and lift, loading & unloading, hire charges of machinery and equipments, transportation charges cost and conveyance of all materials, labour charges and all other incidental charges etc., complete as per standard technical detailed specification and design and directions of the engineer incharge of the work ( 1 ) 7 ( 2 ) 7 ( 3 ) 7 ( 4 ) 7 ( 5 ) 7 ( 6 ) 7 ( 7 ) 7 each 49 42 supplying and fixing of modular switch & connected accessories on existing modular switch plate as per is 3854 and is 1293. stepped fan regulator two module with all lead and lift, loading & unloading, hire charges of machinery and equipments, transportation charges cost and conveyance of all materials, labour charges and all other incidental charges etc., complete as per standard technical detailed specification and design and directions of the engineer incharge of the work ( 1 ) 3 ( 2 ) 3 ( 3 ) 3 ( 4 ) 3 ( 5 ) 3 ( 6 ) 3 ( 7 ) 3 each 21 43 supplying and fixing of modular switch & connected accessories on existing modular switch plate as per is 3854 and is 1293. 16a one way switch with all lead and lift, loading & unloading, hire charges of machinery and equipments, transportation charges cost and conveyance of all materials, labour charges and all other incidental charges etc., complete as per standard technical detailed specification and design and directions of the engineer incharge of the work ( 1 ) 2 ( 2 ) 2 ( 3 ) 2 ( 4 ) 2 ( 5 ) 2 ( 6 ) 2 ( 7 ) 2 each 14 44 supplying and fixing of modular switch & connected accessories on existing modular switch plate as per is 3854 and is 1293. 6 / 16a universal socket with all lead and lift, loading & unloading, hire charges of machinery and equipments, transportation charges cost and conveyance of all materials, labour charges and all other incidental charges etc., complete as per standard technical detailed specification and design and directions of the engineer incharge of the work ( 1 ) 1 ( 2 ) 1 ( 3 ) 1 ( 4 ) 1 ( 5 ) 1 ( 6 ) 1 ( 7 ) 1 each 7 45 supplying and fixing of modular switch & connected accessories on existing modular switch plate as per is 3854 and is 1293. rj45 / i.o outlet cat 6 with all lead and lift, loading & unloading, hire charges of machinery and equipments, transportation charges cost and conveyance of all materials, labour charges and all other incidental charges etc., complete as per standard technical detailed specification and design and directions of the engineer incharge of the work ( 1 ) 1 ( 2 ) 1 ( 3 ) 1 ( 4 ) 1 ( 5 ) 1 ( 6 ) 1 ( 7 ) 1 each 7 46 supplying and fixing regular mccb distribution panel confirming to is / iec 61439 3 and ik09 tested as per is / iec 62262 with minimum ip43 protection provided with polyurethane ( pur ) gasket, with suitable earthing system, on wall / wood board / flush mounting using required cl a , bolts, nuts, etc., with provision for fixing of suitable type capacity mccbs as an incomer for 3 phase double door with necessary bus bar completely wired to use on 440v 3phase 4 wire powder coated painting etc., complete with a provision for fixing of single / three phase suitable capacity mcbs as outgoings confirming to is / iec 60898 4 way with all lead and lift, loading & unloading, hire charges of machinery and equipments, transportation charges cost and conveyance of all materials, labour charges and all other incidental charges etc., complete as per standard technical detailed specification and design and directions of the engineer incharge of the work ( 1 ) 1 ( 2 ) 1 ( 3 ) 1 ( 4 ) 1 ( 5 ) 1 ( 6 ) 1 ( 7 ) 1 each 7 47 supplying, fixing and wiring residual current circuit breaker ( rccb ) 240 / 450v upto 300ma sensitivity on existing wood / panel board. 32 40a 2 pole. with all lead and lift, loading & unloading, hire charges of machinery and equipments, transportation charges cost and conveyance of all materials, labour charges and all other incidental charges etc., complete as per standard technical detailed specification and design and directions of the engineer incharge of the work ( 1 ) 1 ( 2 ) 1 ( 3 ) 1 ( 4 ) 1 ( 5 ) 1 ( 6 ) 1 ( 7 ) 1 each 7 48 supplying & fixing miniature circuit breakers on existing mcb distribution boards using necessary fixing materials and c type curve, indicator on / off, energy cross 3 with short circuit breaking capacity of 10k and complete wiring as required confirming to iec 60898. 6 32 a sp with all lead and lift, loading & unloading, hire charges of machinery and equipments, transportation charges cost and conveyance of all materials, labour charges and all other incidental charges etc., complete as per standard technical detailed specification and design and directions of the engineer incharge of the work ( 1 ) 1 ( 2 ) 1 ( 3 ) 1 ( 4 ) 1 ( 5 ) 1 ( 6 ) 1 ( 7 ) 1 each 7 49 supplying capacitor type ceiling fan complete with down rod blades, shackle, canopies etc, for operation on 230 v, 50 cycles. single phase ac supply conforming to iss 374 1979 and with double ball bearing system. 48 sweep ( 1200 mm ) regular model with all lead and lift, loading & unloading, hire charges of machinery and equipments, transportation charges cost and conveyance of all materials, labour charges and all other incidental charges etc., complete as per standard technical detailed specification and design and directions of the engineer incharge of the work ( 1 ) 2 ( 2 ) 2 ( 3 ) 2 ( 4 ) 2 ( 5 ) 2 ( 6 ) 2 ( 7 ) 2 each 14 50 fixing a ceiling / wall mounting fan of all capacities and all types, with necessary cla and s hook made out of 15mm dia ms rod, with 5 a. ceiling rose of approved quality with necessary length of 23 / 0.0076 inch pvc insulated twin twisted wire of approved quality, mounted on a suitable size wooden board and wired. with all lead and lift, loading & unloading, hire charges of machinery and equipments, transportation charges cost and conveyance of all materials, labour charges and all other incidental charges etc., complete as per standard technical detailed specification and design and directions of the engineer incharge of the work ( 1 ) 2 ( 2 ) 2 ( 3 ) 2 ( 4 ) 2 ( 5 ) 2 ( 6 ) 2 ( 7 ) 2 each 14 51 supplying of .....feet pvc batten with integrated led tube .... w with high quality diffuser with life of 25000 burning hours & 70% lumen maintenance with cri > 80. power input: 220 240v@ 50 / 60hz & power factor >0.9 along with ce approved. 2 years warranty against any manufacturing defect working under standard electrical condition. led light fitting 1 x 4 20 / 22 w with all lead and lift, loading & unloading, hire charges of machinery and equipments, transportation charges cost and conveyance of all materials, labour charges and all other incidental charges etc., complete as per standard technical detailed specification and design and directions of the engineer incharge of the work ( 1 ) 7 ( 2 ) 7 ( 3 ) 7 ( 4 ) 7 ( 5 ) 7 ( 6 ) 7 ( 7 ) 7 each 49 52 supplying, fixing, wiring, earth electrode for grounding conduits, i.c. cutouts and other equipments on the meter board using 40mm dia 2.90mm thick gi pipe 2.5 mtr long buried in a pit … the pit should be filled with equal proportion of salt and charcoal 150mm all round the pipe to complete depth. the connection from the pipe to the conduit etc., is to be established through gi wire of size as per isi specification 7.3.3. of is 732 using 12mm dia bolts, nuts, washers and check nuts etc., the pipe shall have 16 through holes of 12 mm diawith all lead and lift, loading & unloading, hire charges of machinery and equipments, transportation charges cost and conveyance of all materials, labour charges and all other incidental charges etc., complete as per standard technical detailed specification and design and directions of the engineer incharge of the work ( 1 ) 1 ( 2 ) 1 ( 3 ) 1 ( 4 ) 1 ( 5 ) 1 ( 6 ) 1 ( 7 ) 1 no 7 53 supplying, fixing and wiring electronic trivector meter ( etv ) 5 to 20a single phase class 1 accuracy with temper proof energy meter. with all lead and lift, loading & unloading, hire charges of machinery and equipments, transportation charges cost and conveyance of all materials, labour charges and all other incidental charges etc., complete as per standard technical detailed specification and design and directions of the engineer incharge of the work ( 1 ) 1 ( 2 ) 1 ( 3 ) 1 ( 4 ) 1 ( 5 ) 1 ( 6 ) 1 ( 7 ) 1 each 7 54 bescom deposite including supervision and agreement charges ( 1 ) 1 ( 2 ) 1 ( 3 ) 1 ( 4 ) 1 ( 5 ) 1 ( 6 ) 1 ( 7 ) 1...

Rural Development Panchayath Raj Engineering Department - Karnataka

34502999 tender for turuvekere taluk package no: tmk tvk 47 / 22 23 1 civil work: earth work excavation by manual means for drains, canals, waste weir, draft, approach channels, key trenches, foundation of bridges and such simillar works in all kinds of soils , as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m including cost of labour, tools & other appurtenaces required to complete the work. in all kinds of soils depth upto 1.5 m with all lead and lift, loading & unloading, hire charges of machinery and equipments, transportation charges cost and conveyance of all materials, labour charges and all other incidental charges etc., complete as per standard technical detailed specification and design and directions of the engineer incharge of the work ( 1 ) 46.93 ( 2 ) 46.93 ( 3 ) 46.93 ( 4 ) 46.93 ( 5 ) 46.93 ( 6 ) 46.93 ( 7 ) 46.93 cum 328.51 2 filling available excavated earth ( excluding rock ) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering with all lead and lift, loading & unloading, hire charges of machinery and equipments, transportation charges cost and conveyance of all materials, labour charges and all other incidental charges etc., complete as per standard technical detailed specification and design and directions of the engineer incharge of the work ( 1 ) 32.85 ( 2 ) 32.85 ( 3 ) 32.85 ( 4 ) 32.85 ( 5 ) 32.85 ( 6 ) 32.85 ( 7 ) 32.85 cum 229.95 3 providing and laying in position plain cement concrete for levelling course for all works in foundation. the granite / trap / basalt crushed graded coarse aggregates and fine aggregates as per relevant is codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. ( the cost of steel reinforcement & formwork shall be paid separately ) mix 1:4:8 ( m5 ) using 40 mm nominal size graded crushed coarse aggregates with all lead and lift, loading & unloading, hire charges of machinery and equipments, transportation charges cost and conveyance of all materials, labour charges and all other incidental charges etc., complete as per standard technical detailed specification and design and directions of the engineer incharge of the work ( 1 ) 11.67 ( 2 ) 11.67 ( 3 ) 11.67 ( 4 ) 11.67 ( 5 ) 11.67 ( 6 ) 11.67 ( 7 ) 11.67 cum 81.69 4 providing random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 ( 1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size ) upto plinth level with : cement mortar 1:6 ( 1 cement : 6 coarse sand ) with all lead and lift, loading & unloading, hire charges of machinery and equipments, transportation charges cost and conveyance of all materials, labour charges and all other incidental charges etc., complete as per standard technical detailed specification and design and directions of the engineer incharge of the work ( 1 ) 12.12 ( 2 ) 12.12 ( 3 ) 12.12 ( 4 ) 12.12 ( 5 ) 12.12 ( 6 ) 12.12 ( 7 ) 12.12 cum 84.84 5 providing coursed rubble masonry ( second sort ) with hard stone in foundation & plinth with cement mortar 1:6 ( 1 cement : 6 coarse sand ) with all lead and lift, loading & unloading, hire charges of machinery and equipments, transportation charges cost and conveyance of all materials, labour charges and all other incidental charges etc., complete as per standard technical detailed specification and design and directions of the engineer incharge of the work ( 1 ) 6.84 ( 2 ) 6.84 ( 3 ) 6.84 ( 4 ) 6.84 ( 5 ) 6.84 ( 6 ) 6.84 ( 7 ) 6.84 cum 47.88 6 appendix i – additionalities for formwork, centering 1. foundation upto plinth a ) isolated 8% with all lead and lift, loading & unloading, hire charges of machinery and equipments, transportation charges cost and conveyance of all materials, labour charges and all other incidental charges etc., complete as per standard technical detailed specification and design and directions of the engineer incharge of the work ( 1 ) 17.81 ( 2 ) 17.81 ( 3 ) 17.81 ( 4 ) 17.81 ( 5 ) 17.81 ( 6 ) 17.81 ( 7 ) 17.81 cum 124.67 7 providing and laying in position reinforced cement concrete for all foundation works. the granite / trap / basalt crushed graded coarse aggregates and fine aggregates as per relevant is codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant is codes , labour, usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. ( the cost of steel reinforcement & formwork to be paid separately ) m20 design mix using 20 mm nominal size graded crushed coarse with all lead and lift, loading & unloading, hire charges of machinery and equipments, transportation charges cost and conveyance of all materials, labour charges and all other incidental charges etc., complete as per standard technical detailed specification and design and directions of the engineer incharge of the work ( 1 ) 17.81 ( 2 ) 17.81 ( 3 ) 17.81 ( 4 ) 17.81 ( 5 ) 17.81 ( 6 ) 17.81 ( 7 ) 17.81 cum 124.67 8 appendix i – additionalities for formwork, centering 8. columns & piers 10%with all lead and lift, loading & unloading, hire charges of machinery and equipments, transportation charges cost and conveyance of all materials, labour charges and all other incidental charges etc., complete as per standard technical detailed specification and design and directions of the engineer incharge of the work ( 1 ) 4.17 ( 2 ) 4.17 ( 3 ) 4.17 ( 4 ) 4.17 ( 5 ) 4.17 ( 6 ) 4.17 ( 7 ) 4.17 cum 29.19 9 appendix i – additionalities for formwork, centering 12. beams & lintels of building 20% 13. roof ( straight & arched ) 20% with all lead and lift, loading & unloading, hire charges of machinery and equipments, transportation charges cost and conveyance of all materials, labour charges and all other incidental charges etc., complete as per standard technical detailed specification and design and directions of the engineer incharge of the work ( 1 ) 15.13 ( 2 ) 15.13 ( 3 ) 15.13 ( 4 ) 15.13 ( 5 ) 15.13 ( 6 ) 15.13 ( 7 ) 15.13 cum 105.91 10 providing thermo mechanically treated bars of grade fe 550d or more steel reinforcement for r.c.c. work including straightening, cutting, bending, placing in position, binding and anchoring to adjacent members whereever necessary complete as per design including cost of material, labour, usage charges complete as per specifications. ( the laps and wastages shall not be measured separately ) with all lead and lift, loading & unloading, hire charges of machinery and equipments, transportation charges cost and conveyance of all materials, labour charges and all other incidental charges etc., complete as per standard technical detailed specification and design and directions of the engineer incharge of the work ( 1 ) 2720.00 ( 2 ) 2720.00 ( 3 ) 2720.00 ( 4 ) 2720.00 ( 5 ) 2720.00 ( 6 ) 2720.00 ( 7 ) 2720.00 kg 19040 11 providing and laying in position reinforced cement concrete for all super structures of building , road works, water works, irrigation works & super structure works of bridges upto 3.50 m height. the granite / trap / basalt crushed graded coarse aggregates and fine aggregates as per relevant is codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. the cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant is codes , labour, usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. ( the cost of steel reinforcement, dowel bars & formwork to be paid separately ) m20 design mix using 20 mm nominal size graded crushed coarse aggregates with all lead and lift, loading & unloading, hire charges of machinery and equipments, transportation charges cost and conveyance of all materials, labour charges and all other incidental charges etc., complete as per standard technical detailed specification and design and directions of the engineer incharge of the work ( 1 ) 20.65 ( 2 ) 20.65 ( 3 ) 20.65 ( 4 ) 20.65 ( 5 ) 20.65 ( 6 ) 20.65 ( 7 ) 20.65 cum 144.55 12 ksrb 4.2.10 : providing and laying in position reinforced cement concrete of design mix m20 with opc cement @ 24kgs, with 2mm and down size graded granite metal coares aggregates @ 0.5175cum and fine aggregates @ 0.345cum, with superplastisiser @ 0.225lts, machine mixed, well compacted for plain chajja of 7.5cms average thickness, upto ground floor level including cost of all materials, labour, hom of machinery, curing, complete as per specifications. specification no. kbs 4.1, 4.6 with all lead and lift, loading & unloading, hire charges of machinery and equipments, transportation charges cost and conveyance of all materials, labour charges and all other incidental charges etc., complete as per standard technical detailed specification and design and directions of the engineer incharge of the work ( 1 ) 2.16 ( 2 ) 2.16 ( 3 ) 2.16 ( 4 ) 2.16 ( 5 ) 2.16 ( 6 ) 2.16 ( 7 ) 2.16 sqm 15.12 13 providing brick work with common burnt clay non modular bricks of class designation 3.5 in foundation and plinth in cement mortar 1:4 ( 1 cement : 4 coarse sand ) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work. with all lead and lift, loading & unloading, hire charges of machinery and equipments, transportation charges cost and conveyance of all materials, labour charges and all other incidental charges etc., complete as per standard technical detailed specification and design and directions of the engineer incharge of the work ( 1 ) 24.68 ( 2 ) 24.68 ( 3 ) 24.68 ( 4 ) 24.68 ( 5 ) 24.68 ( 6 ) 24.68 ( 7 ) 24.68 cum 172.76 14 providing 12 mm cement plaster with cement mortar 1:4 ( 1 cement: 4 fine sand ) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of engineer in charge. with all lead and lift, loading & unloading, hire charges of machinery and equipments, transportation charges cost and conveyance of all materials, labour charges and all other incidental charges etc., complete as per standard technical detailed specification and design and directions of the engineer incharge of the work ( 1 ) 44.46 ( 2 ) 44.46 ( 3 ) 44.46 ( 4 ) 44.46 ( 5 ) 44.46 ( 6 ) 44.46 ( 7 ) 44.46 sqm 311.22 15 providing 15 mm cement plaster on the rough side of single or half brick wall of mix 1:4 ( 1 cement: 4 fine sand ) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of engineer in charge. with all lead and lift, loading & unloading, hire charges of machinery and equipments, transportation charges cost and conveyance of all materials, labour charges and all other incidental charges etc., complete as per standard technical detailed specification and design and directions of the engineer incharge of the work ( 1 ) 58.28 ( 2 ) 58.28 ( 3 ) 58.28 ( 4 ) 58.28 ( 5 ) 58.28 ( 6 ) 58.28 ( 7 ) 58.28 sqm 407.96 16 providing 20 mm cement plaster of mix :1:4 ( 1 cement: 4 fine sand ) to brick / stone masonary including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of engineer in charge. with all lead and lift, loading & unloading, hire charges of machinery and equipments, transportation charges cost and conveyance of all materials, labour charges and all other incidental charges etc., complete as per standard technical detailed specification and design and directions of the engineer incharge of the work ( 1 ) 171.64 ( 2 ) 171.64 ( 3 ) 171.64 ( 4 ) 171.64 ( 5 ) 171.64 ( 6 ) 171.64 ( 7 ) 171.64 sqm 1201.48 17 flooring with 25mm thick polished tandur blue stone slabs using cement mortar 1:6, 25mm thick over existing cement concrete bed or top of roof laid to line and level and jointed with cement slurry mixed with pigment to match the shade of the slab, , including cost of materials, labour, curing, polishing complete as per specifications. with all lead and lift, loading & unloading, hire charges of machinery and equipments, transportation charges cost and conveyance of all materials, labour charges and all other incidental charges etc., complete as per standard technical detailed specification and design and directions of the engineer incharge of the work ( 1 ) 58.79 ( 2 ) 58.79 ( 3 ) 58.79 ( 4 ) 58.79 ( 5 ) 58.79 ( 6 ) 58.79 ( 7 ) 58.79 sqm 411.53 18 finishing walls with acrylic smooth exterior paint of required shade :new work ( two coat applied @ 1.67 ltr / 10 m� over and including priming coat of exterior primer applied @ 2.20 kg / 10 m� ) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of engineer in charge. with all lead and lift, loading & unloading, hire charges of machinery and equipments, transportation charges cost and conveyance of all materials, labour charges and all other incidental charges etc., complete as per standard technical detailed specification and design and directions of the engineer incharge of the work ( 1 ) 102.74 ( 2 ) 102.74 ( 3 ) 102.74 ( 4 ) 102.74 ( 5 ) 102.74 ( 6 ) 102.74 ( 7 ) 102.74 sqm 719.18 19 providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of engineer in charge. with all lead and lift, loading & unloading, hire charges of machinery and equipments, transportation charges cost and conveyance of all materials, labour charges and all other incidental charges etc., complete as per standard technical detailed specification and design and directions of the engineer incharge of the work ( 1 ) 58.79 ( 2 ) 58.79 ( 3 ) 58.79 ( 4 ) 58.79 ( 5 ) 58.79 ( 6 ) 58.79 ( 7 ) 58.79 sqm 411.53 20 wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade :two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of engineer in charge. with all lead and lift, loading & unloading, hire charges of machinery and equipments, transportation charges cost and conveyance of all materials, labour charges and all other incidental charges etc., complete as per standard technical detailed specification and design and directions of the engineer incharge of the work ( 1 ) 58.79 ( 2 ) 58.79 ( 3 ) 58.79 ( 4 ) 58.79 ( 5 ) 58.79 ( 6 ) 58.79 ( 7 ) 58.79 sqm 411.53 21 providing and fixing 1mm thick m.s. sheet door with frame of 40x40x6 mm angle iron and 3 mm m.s. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. using m.s. angels 40x40x6 mm for diagonal braces including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the engineer in charge. with all lead and lift, loading & unloading, hire charges of machinery and equipments, transportation charges cost and conveyance of all materials, labour charges and all other incidental charges etc., complete as per standard technical detailed specification and design and directions of the engineer incharge of the work ( 1 ) 2.52 ( 2 ) 2.52 ( 3 ) 2.52 ( 4 ) 2.52 ( 5 ) 2.52 ( 6 ) 2.52 ( 7 ) 2.52 sqm 17.64 22 providing and fixing factory made isi marked steel glazed doors, windows and ventilators, side / top / centre hung, with beading and all members such as f7d, f4b, k11 b and k12 b etc. complete of standard rolled steel sections, joints mitred and flash butt welded and sash bars tenoned and riveted, including providing and fixing of hinges, pivots, including priming coat of approved steel primer, but excluding the cost of other fittings, complete all as per approved design, ( sectional weight of only steel members shall be measured for payment ) . with all lead and lift, loading & unloading, hire charges of machinery and equipments, transportation charges cost and conveyance of all materials, labour charges and all other incidental charges etc., complete as per standard technical detailed specification and design and directions of the engineer incharge of the work ( 1 ) 120.96 ( 2 ) 120.96 ( 3 ) 120.96 ( 4 ) 120.96 ( 5 ) 120.96 ( 6 ) 120.96 ( 7 ) 120.96 kg 846.72 23 painting steel work with deluxe multi surface paint to give an even shade. two coat applied @ 0.90 ltr / 10 m� over an under coat of primer applied @ 0.80 ltr / 10 m� of approved brand and manufacture including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of engineer in charge. with all lead and lift, loading & unloading, hire charges of machinery and equipments, transportation charges cost and conveyance of all materials, labour charges and all other incidental charges etc., complete as per standard technical detailed specification and design and directions of the engineer incharge of the work ( 1 ) 36.63 ( 2 ) 36.63 ( 3 ) 36.63 ( 4 ) 36.63 ( 5 ) 36.63 ( 6 ) 36.63 ( 7 ) 36.63 sqm 256.41 24 providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approved steel primer. m.s. tube including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the engineerin charge.with all lead and lift, loading & unloading, hire charges of machinery and equipments, transportation charges cost and conveyance of all materials, labour charges and all other incidental charges etc., complete as per standard technical detailed specification and design and directions of the engineer incharge of the work ( 1 ) 105.00 ( 2 ) 105.00 ( 3 ) 105.00 ( 4 ) 105.00 ( 5 ) 105.00 ( 6 ) 105.00 ( 7 ) 105.00 kg 735 25 providing and fixing on wall face unplasticised rigid pvc rain water pipes conforming to is : 13592 type a, including jointing with seal ring conforming to is : 5382 leaving 10 mm gap for thermal exxpansion ( i ) single socketed pipe 100 mm diameter with all lead and lift, loading & unloading, hire charges of machinery and equipments, transportation charges cost and conveyance of all materials, labour charges and all other incidental charges etc., complete as per standard technical detailed specification and design and directions of the engineer incharge of the work ( 1 ) 9.00 ( 2 ) 9.00 ( 3 ) 9.00 ( 4 ) 9.00 ( 5 ) 9.00 ( 6 ) 9.00 ( 7 ) 9.00 mtr 63 26 providing and laying water proofing treatment to the roof with pu based single component elastomeric pure polyurethane based coating on new terrace / chajjas / sunken portion of wc:bathroom, cold applied pu waterproofing membrane that is highly elastic with elongation greater than 400% and tensile strength greater than 2mpa as per astm d412. the waterproofing membrane to be applied in 2coats @ 1.6kg per m2 to achieve final dft ( dry film thickness ) of 1mm including prime coat of epoxy primer @150 g per m2 and protection with 120gsm geo textile over the waterproofing membrane. the finished cost to include surface preparation, making coving at junction, bore packing, treatment of construction joints completely as per specification & with a 10 years warranty on product & work from certified manufacturers as per the direction of the engineer in charge.with all lead and lift, loading & unloading, hire charges of machinery and equipments, transportation charges cost and conveyance of all materials, labour charges and all other incidental charges etc., complete as per standard technical detailed specification and design and directions of the engineer incharge of the work ( 1 ) 49.47 ( 2 ) 49.47 ( 3 ) 49.47 ( 4 ) 49.47 ( 5 ) 49.47 ( 6 ) 49.47 ( 7 ) 49.47 sqm 346.29 27 providing wall black boards in cm 1:3 with two coats of black paint including finishing etc., complete. with all lead and lift, loading & unloading, hire charges of machinery and equipments, transportation charges cost and conveyance of all materials, labour charges and all other incidental charges etc., complete as per standard technical detailed specification and design and directions of the engineer incharge of the work ( 1 ) 3.00 ( 2 ) 3.00 ( 3 ) 3.00 ( 4 ) 3.00 ( 5 ) 3.00 ( 6 ) 3.00 ( 7 ) 3.00 sqm 21 28 electrification: supplying heavy gauge pvc conduit pipe ...... mm dia..........mm thick confirming to is 2509 with suitable size bends, metal / pvc junction boxes, adhesive paste etc., and running before concreting the slab. the conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using pvc end enclosures, run with 18swg gi fish wire wherever necessary 19 / 20 mm dia 2 mm thick with all lead and lift, loading & unloading, hire charges of machinery and equipments, transportation charges cost and conveyance of all materials, labour charges and all other incidental charges etc., complete as per standard technical detailed specification and design and directions of the engineer incharge of the work ( 1 ) 30.00 ( 2 ) 30.00 ( 3 ) 30.00 ( 4 ) 30.00 ( 5 ) 30.00 ( 6 ) 30.00 ( 7 ) 30.00 mtr 210 29 upplying heavy gauge pvc conduit pipe .... dia ....... mm thick with suitable size bends, metal junction boxes adhesive paste etc., by groove cutting in the wall and fixing by bracing u or j hooks and cement plastering upto the wall surface and run with 18 swg gi fish wire run throughout the conduit wherever necessary 19 / 20 mm dia 2 mm thick with all lead and lift, loading & unloading, hire charges of machinery and equipments, transportation charges cost and conveyance of all materials, labour charges and all other incidental charges etc., complete as per standard technical detailed specification and design and directions of the engineer incharge of the work ( 1 ) 20.00 ( 2 ) 20.00 ( 3 ) 20.00 ( 4 ) 20.00 ( 5 ) 20.00 ( 6 ) 20.00 ( 7 ) 20.00 mtr 140 30 supplying and fixing sheet metal box made out of 18 swg sheet metal with necessary holes for cable / conduit entry as required with one coat of primer of approved make etc.135 x 75 x 65 mm with all lead and lift, loading & unloading, hire charges of machinery and equipments, transportation charges cost and conveyance of all materials, labour charges and all other incidental charges etc., complete as per standard technical detailed specification and design and directions of the engineer incharge of the work ( 1 ) 2 ( 2 ) 2 ( 3 ) 2 ( 4 ) 2 ( 5 ) 2 ( 6 ) 2 ( 7 ) 2 each 14 31 supplying and fixing sheet metal box made out of 18 swg sheet metal with necessary holes for cable / conduit entry as required with one coat of primer of approved make etc. 200 x 200 x 65 mm with all lead and lift, loading & unloading, hire charges of machinery and equipments, transportation charges cost and conveyance of all materials, labour charges and all other incidental charges etc., complete as per standard technical detailed specification and design and directions of the engineer incharge of the work ( 1 ) 1 ( 2 ) 1 ( 3 ) 1 ( 4 ) 1 ( 5 ) 1 ( 6 ) 1 ( 7 ) 1 each 7 32 supplying and fixing pvc / metal conduit deep junction box 32 mm deep junction box with all lead and lift, loading & unloading, hire charges of machinery and equipments, transportation charges cost and conveyance of all materials, labour charges and all other incidental charges etc., complete as per standard technical detailed specification and design and directions of the engineer incharge of the work ( 1 ) 7 ( 2 ) 7 ( 3 ) 7 ( 4 ) 7 ( 5 ) 7 ( 6 ) 7 ( 7 ) 7 each 49 33 supplying and fixing metal fan box with round hook. with all lead and lift, loading & unloading, hire charges of machinery and equipments, transportation charges cost and conveyance of all materials, labour charges and all other incidental charges etc., complete as per standard technical detailed specification and design and directions of the engineer incharge of the work ( 1 ) 7 ( 2 ) 7 ( 3 ) 7 ( 4 ) 7 ( 5 ) 7 ( 6 ) 7 ( 7 ) 7 each 49 34 supplying and wiring adopting loop system in existing pvc conduit / casing capping casing capping using 2x1.5mm2 ( phase & neutral ) & 1x1.0 mm2 ( earth wire ) frls multi strand pvc insulated copper wire ( confirming to is 694: and latest amendments ) without control switch shall be fixed on the existing plastic sheet / gang box, the other end of the wires shall be terminated with sufficient loose length in a wood / pvc round block. complete for each outlet. medium point above 3m upto 6m from tapping point to out let via switch box with all lead and lift, loading & unloading, hire charges of machinery and equipments, transportation charges cost and conveyance of all materials, labour charges and all other incidental charges etc., complete as per standard technical detailed specification and design and directions of the engineer incharge of the work ( 1 ) 10 ( 2 ) 10 ( 3 ) 10 ( 4 ) 10 ( 5 ) 10 ( 6 ) 10 ( 7 ) 10 point 70 35 wiring for lighting / power circuit using one of frls pvc insulated 1100v grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified is 694:confirming to latest amendments. 1.5 mm2 with all lead and lift, loading & unloading, hire charges of machinery and equipments, transportation charges cost and conveyance of all materials, labour charges and all other incidental charges etc., complete as per standard technical detailed specification and design and directions of the engineer incharge of the work ( 1 ) 20.00 ( 2 ) 20.00 ( 3 ) 20.00 ( 4 ) 20.00 ( 5 ) 20.00 ( 6 ) 20.00 ( 7 ) 20.00 mtr 140 36 supplying and drawing flexible multicore cable manufactured with electrolytic grade flexible copper with low conductor confirming to is 8130 1984 and ( virgin ) pvc insulation sheathed suitable for working voltage upto 1100v as per is694:2010 3c x 4 mm2 with all lead and lift, loading & unloading, hire charges of machinery and equipments, transportation charges cost and conveyance of all materials, labour charges and all other incidental charges etc., complete as per standard technical detailed specification and design and directions of the engineer incharge of the work ( 1 ) 30.00 ( 2 ) 30.00 ( 3 ) 30.00 ( 4 ) 30.00 ( 5 ) 30.00 ( 6 ) 30.00 ( 7 ) 30.00 mtr 210 37 supplying and fixing surface / flush mounting unbreakable pvc modular box suitable for mounting modular switch plates with due groove cutting in brick / c.c wall, including necessary rawl plugs, machine / nf screws etc., complete. 6 way with all lead and lift, loading & unloading, hire charges of machinery and equipments, transportation charges cost and conveyance of all materials, labour charges and all other incidental charges etc., complete as per standard technical detailed specification and design and directions of the engineer incharge of the work ( 1 ) 2 ( 2 ) 2 ( 3 ) 2 ( 4 ) 2 ( 5 ) 2 ( 6 ) 2 ( 7 ) 2 each 14 38 supplying and fixing surface / flush mounting unbreakable pvc modular box suitable for mounting modular switch plates with due groove cutting in brick / c.c wall, including necessary rawl plugs, machine / nf screws etc., complete. 16 18 way with all lead and lift, loading & unloading, hire charges of machinery and equipments, transportation charges cost and conveyance of all materials, labour charges and all other incidental charges etc., complete as per standard technical detailed specification and design and directions of the engineer incharge of the work ( 1 ) 1 ( 2 ) 1 ( 3 ) 1 ( 4 ) 1 ( 5 ) 1 ( 6 ) 1 ( 7 ) 1 each 7 39 supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal / pvc box 6 way with all lead and lift, loading & unloading, hire charges of machinery and equipments, transportation charges cost and conveyance of all materials, labour charges and all other incidental charges etc., complete as per standard technical detailed specification and design and directions of the engineer incharge of the work ( 1 ) 2 ( 2 ) 2 ( 3 ) 2 ( 4 ) 2 ( 5 ) 2 ( 6 ) 2 ( 7 ) 2 each 14 40 supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal / pvc box 16 18 way with all lead and lift, loading & unloading, hire charges of machinery and equipments, transportation charges cost and conveyance of all materials, labour charges and all other incidental charges etc., complete as per standard technical detailed specification and design and directions of the engineer incharge of the work ( 1 ) 1 ( 2 ) 1 ( 3 ) 1 ( 4 ) 1 ( 5 ) 1 ( 6 ) 1 ( 7 ) 1 each 7 41 supplying and fixing of modular switch & connected accessories on existing modular switch plate as per is 3854 and is 1293. 6a one way switch with all lead and lift, loading & unloading, hire charges of machinery and equipments, transportation charges cost and conveyance of all materials, labour charges and all other incidental charges etc., complete as per standard technical detailed specification and design and directions of the engineer incharge of the work ( 1 ) 7 ( 2 ) 7 ( 3 ) 7 ( 4 ) 7 ( 5 ) 7 ( 6 ) 7 ( 7 ) 7 each 49 42 supplying and fixing of modular switch & connected accessories on existing modular switch plate as per is 3854 and is 1293. stepped fan regulator two module with all lead and lift, loading & unloading, hire charges of machinery and equipments, transportation charges cost and conveyance of all materials, labour charges and all other incidental charges etc., complete as per standard technical detailed specification and design and directions of the engineer incharge of the work ( 1 ) 3 ( 2 ) 3 ( 3 ) 3 ( 4 ) 3 ( 5 ) 3 ( 6 ) 3 ( 7 ) 3 each 21 43 supplying and fixing of modular switch & connected accessories on existing modular switch plate as per is 3854 and is 1293. 16a one way switch with all lead and lift, loading & unloading, hire charges of machinery and equipments, transportation charges cost and conveyance of all materials, labour charges and all other incidental charges etc., complete as per standard technical detailed specification and design and directions of the engineer incharge of the work ( 1 ) 2 ( 2 ) 2 ( 3 ) 2 ( 4 ) 2 ( 5 ) 2 ( 6 ) 2 ( 7 ) 2 each 14 44 supplying and fixing of modular switch & connected accessories on existing modular switch plate as per is 3854 and is 1293. 6 / 16a universal socket with all lead and lift, loading & unloading, hire charges of machinery and equipments, transportation charges cost and conveyance of all materials, labour charges and all other incidental charges etc., complete as per standard technical detailed specification and design and directions of the engineer incharge of the work ( 1 ) 1 ( 2 ) 1 ( 3 ) 1 ( 4 ) 1 ( 5 ) 1 ( 6 ) 1 ( 7 ) 1 each 7 45 supplying and fixing of modular switch & connected accessories on existing modular switch plate as per is 3854 and is 1293. rj45 / i.o outlet cat 6 with all lead and lift, loading & unloading, hire charges of machinery and equipments, transportation charges cost and conveyance of all materials, labour charges and all other incidental charges etc., complete as per standard technical detailed specification and design and directions of the engineer incharge of the work ( 1 ) 1 ( 2 ) 1 ( 3 ) 1 ( 4 ) 1 ( 5 ) 1 ( 6 ) 1 ( 7 ) 1 each 7 46 supplying and fixing regular mccb distribution panel confirming to is / iec 61439 3 and ik09 tested as per is / iec 62262 with minimum ip43 protection provided with polyurethane ( pur ) gasket, with suitable earthing system, on wall / wood board / flush mounting using required cl a , bolts, nuts, etc., with provision for fixing of suitable type capacity mccbs as an incomer for 3 phase double door with necessary bus bar completely wired to use on 440v 3phase 4 wire powder coated painting etc., complete with a provision for fixing of single / three phase suitable capacity mcbs as outgoings confirming to is / iec 60898 4 way with all lead and lift, loading & unloading, hire charges of machinery and equipments, transportation charges cost and conveyance of all materials, labour charges and all other incidental charges etc., complete as per standard technical detailed specification and design and directions of the engineer incharge of the work ( 1 ) 1 ( 2 ) 1 ( 3 ) 1 ( 4 ) 1 ( 5 ) 1 ( 6 ) 1 ( 7 ) 1 each 7 47 supplying, fixing and wiring residual current circuit breaker ( rccb ) 240 / 450v upto 300ma sensitivity on existing wood / panel board. 32 40a 2 pole. with all lead and lift, loading & unloading, hire charges of machinery and equipments, transportation charges cost and conveyance of all materials, labour charges and all other incidental charges etc., complete as per standard technical detailed specification and design and directions of the engineer incharge of the work ( 1 ) 1 ( 2 ) 1 ( 3 ) 1 ( 4 ) 1 ( 5 ) 1 ( 6 ) 1 ( 7 ) 1 each 7 48 supplying & fixing miniature circuit breakers on existing mcb distribution boards using necessary fixing materials and c type curve, indicator on / off, energy cross 3 with short circuit breaking capacity of 10k and complete wiring as required confirming to iec 60898. 6 32 a sp with all lead and lift, loading & unloading, hire charges of machinery and equipments, transportation charges cost and conveyance of all materials, labour charges and all other incidental charges etc., complete as per standard technical detailed specification and design and directions of the engineer incharge of the work ( 1 ) 1 ( 2 ) 1 ( 3 ) 1 ( 4 ) 1 ( 5 ) 1 ( 6 ) 1 ( 7 ) 1 each 7 49 supplying capacitor type ceiling fan complete with down rod blades, shackle, canopies etc, for operation on 230 v, 50 cycles. single phase ac supply conforming to iss 374 1979 and with double ball bearing system. 48 sweep ( 1200 mm ) regular model with all lead and lift, loading & unloading, hire charges of machinery and equipments, transportation charges cost and conveyance of all materials, labour charges and all other incidental charges etc., complete as per standard technical detailed specification and design and directions of the engineer incharge of the work ( 1 ) 2 ( 2 ) 2 ( 3 ) 2 ( 4 ) 2 ( 5 ) 2 ( 6 ) 2 ( 7 ) 2 each 14 50 fixing a ceiling / wall mounting fan of all capacities and all types, with necessary cla and s hook made out of 15mm dia ms rod, with 5 a. ceiling rose of approved quality with necessary length of 23 / 0.0076 inch pvc insulated twin twisted wire of approved quality, mounted on a suitable size wooden board and wired. with all lead and lift, loading & unloading, hire charges of machinery and equipments, transportation charges cost and conveyance of all materials, labour charges and all other incidental charges etc., complete as per standard technical detailed specification and design and directions of the engineer incharge of the work ( 1 ) 2 ( 2 ) 2 ( 3 ) 2 ( 4 ) 2 ( 5 ) 2 ( 6 ) 2 ( 7 ) 2 each 14 51 supplying of .....feet pvc batten with integrated led tube .... w with high quality diffuser with life of 25000 burning hours & 70% lumen maintenance with cri > 80. power input: 220 240v@ 50 / 60hz & power factor >0.9 along with ce approved. 2 years warranty against any manufacturing defect working under standard electrical condition. led light fitting 1 x 4 20 / 22 w with all lead and lift, loading & unloading, hire charges of machinery and equipments, transportation charges cost and conveyance of all materials, labour charges and all other incidental charges etc., complete as per standard technical detailed specification and design and directions of the engineer incharge of the work ( 1 ) 7 ( 2 ) 7 ( 3 ) 7 ( 4 ) 7 ( 5 ) 7 ( 6 ) 7 ( 7 ) 7 each 49 52 supplying, fixing, wiring, earth electrode for grounding conduits, i.c. cutouts and other equipments on the meter board using 40mm dia 2.90mm thick gi pipe 2.5 mtr long buried in a pit … the pit should be filled with equal proportion of salt and charcoal 150mm all round the pipe to complete depth. the connection from the pipe to the conduit etc., is to be established through gi wire of size as per isi specification 7.3.3. of is 732 using 12mm dia bolts, nuts, washers and check nuts etc., the pipe shall have 16 through holes of 12 mm diawith all lead and lift, loading & unloading, hire charges of machinery and equipments, transportation charges cost and conveyance of all materials, labour charges and all other incidental charges etc., complete as per standard technical detailed specification and design and directions of the engineer incharge of the work ( 1 ) 1 ( 2 ) 1 ( 3 ) 1 ( 4 ) 1 ( 5 ) 1 ( 6 ) 1 ( 7 ) 1 no 7 53 supplying, fixing and wiring electronic trivector meter ( etv ) 5 to 20a single phase class 1 accuracy with temper proof energy meter. with all lead and lift, loading & unloading, hire charges of machinery and equipments, transportation charges cost and conveyance of all materials, labour charges and all other incidental charges etc., complete as per standard technical detailed specification and design and directions of the engineer incharge of the work ( 1 ) 1 ( 2 ) 1 ( 3 ) 1 ( 4 ) 1 ( 5 ) 1 ( 6 ) 1 ( 7 ) 1 each 7 54 bescom deposite including supervision and agreement charges ( 1 ) 1 ( 2 ) 1 ( 3 ) 1 ( 4 ) 1 ( 5 ) 1 ( 6 ) 1 ( 7 ) 1...

Council Of Scientific And Industrial Research - Karnataka

34246759 renovation of room no. 6 at tfss dept. for housing e nose & e tongue equipment at csir cftri, mysuru demolishing brick work manually / by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of engineer in charge.in cement mortar 3 demolishing cement concrete manually / by mechanical means including disposal of material within 50 metres lead as per direction of engineer in charge.nominal concrete 1:4:8 or leaner mix ( i / c equivalent design mix ) 4 dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 metres lead.for thickness of tiles 10 mm to 25 mm 5 removing sink of any size including stacking of useful materials within 50 metres lead or to the auction yard of cftri as directed by engineer in charge. 6 dismantling g.i pipes ( exposed on wall ) including all necessary fittings manually / by mechanical means including stacking of pipes within 50 metres lead as per direction of engineer in charge:15 mm to 40 mm nominal bore 7 dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead. 8 hacking of cc flooring including cleaning for surface etc. complete as per direction of the engineer in charge. 9 repairs to plaster of thickness 12 mm to 20 mm in patches of area 2.5 sq.meters and under, including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete, including disposal of rubbish to the dumping ground, all complete as per direction of engineer in charge.with cement mortar 1:4 ( 1cement: 4 m sand ) 10 providing and laying vitrified tiles in floor in different sizes ( minimum thickness of 10 mm ) with water absorption less than 0.08% and conforming to is:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 ( 1 cement: 4 m sand ) jointing with grey cement slurry @3.3 kg / sqm including grouting the joints with white cement and matching pigments etc. the tiles must be cut with the zero chipping diamond cutter only. laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily.double charge vitrified tile polished finish of size ( tile cost is considered for rs 80.00 / sq.ft or rs. 861 / per sqm including gst ) size of tile 600 x 600 mmmake: somany / kajaria / rak / nitco 11 providing and laying vitrified tiles in different sizes ( thickness to be specified by manufacturer ) , with water absorption less than 0.08 % and conforming to i.s. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar1:3 ( 1 cement: 3 m sand ) , including grouting the joint with white cement & matching pigments etc. complete. ( tile cost is considered for rs 80.00 / sq.ft or rs. 861 / per sqm including gst ) size of tile 600x600 mmmake: somany / kajaria / rak / nitco 12 providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 ( 1 cement : 4 m sand ) , joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing of edges to give high gloss finish etc. complete at all levels.granite stone slab of colour black, cherry / ruby redarea of slab over 0.50 sqm 13 providing edge moulding to 18 mm thick marble stone counters, vanities etc., including machine polishing to edge to give high gloss finish etc. complete as per design approved by engineer in charge.granite work 14 extra for providing opening of required size & shape for wash basin / kitchen sink in kitchen platform, vanity counter and similar location in marble / granite / stone work, including necessary holes for pillar taps etc. including moulding, rubbing and polishing of cut edges etc. complete. 15 providing and fixing tiled false ceiling of approved materials of size 600x600 mm in true horizontal level suspended on inter locking metal grid of hot dipped galvanised steel sections ( galvanized @ 170 gsm / sqm ) consisting of main t runner with suitably spaced joints to get required length and of size 24x32mm made from 0.30mm thick ( minimum ) sheet spaced at 1200mm center to center and cross t of size 24x25mm made of 0.30mm thick ( minimum ) sheet, 1200mm long spaced between main tat 600mm center to centerto form a grid of 1200x600 mm and secondary cross t of length 600mm and size 24x25mm made of 0.30 mm thick ( minimum ) sheet to be interlocked at middle of the 1200x600mm panel to form grids of 600x600mm and wall angle of size 24x24x0.3mm and laying false ceiling tiles of approved texture in the grid including, required, cutting / making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. main t runners to be suspended from ceiling using gi slotted cleats of size 27x37x25x1.6 mm fixed to ceiling with 12.5 mm dia and 50mm long dash fasteners, 4mm gi adjustable rods with galvanised butterfly level clips of size 85 x 30 x 0.8 mm spaced at 1200mm center to center along main t, bottom exposed width of 24mm of all t sections shall be pre painted with polyester paint, all complete for all heights as per specifications drawings and as directed by engineer in charge. 9 mm thick square edge pvc laminated gypsum tile of size 600x600 mm, made of gypsum plasterboard, manufactured from natural gypsum as per is 2095 part i and laminated with white 0.16 mm thick fire retardant pvc film on the face side and 12 micron metalized polyester on the back side with all edges sealed with the face side pvc film which goes around and wraps the edges and is bonded to the edges and the back side metalized polyester film so as to make the tile a completely sealed unit.the tiles should have thermal conductivity k = 0.24 w / m k, colour white, fire performance class 0 / class1 ( bs 476 part 6&7 ) in module size of 600 x 600 x 9 mmmake: armgyp dew drops ( armstrong ) 16 providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections / appropriate z sections and other sections of approved make conforming to is: 733 and is: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required epdm rubber / neoprene gasket etc. aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, aluminium snap beading for glazing / paneling, c.p. brass / stainless steel screws, all complete as per architectural drawings and the directions of engineer in charge. ( glazing, panelingand dash fasteners to be paid for separately ) :for fixed portionpowder coated aluminium ( minimum thickness of powder coating 50 micron ) make: jindal 17 providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections / appropriate z sections and other sections of approved make conforming to is: 733 and is: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required epdm rubber / neoprene gasket etc. aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, aluminium snap beading for glazing / paneling c.p. brass / stainless steel screws, all complete as per architectural drawings and the directions of engineer in charge. ( glazing, paneling and dash fasteners to be paid for separately ) :for shutters of doors, windows & ventilators including providing and fixing hinges / pivots and making provision for fixing of fittings wherever required including the cost of epdm rubber / neoprene gasket required ( fittings shall be paid for separately ) powder coated aluminium ( minimum thickness of powder coating 50 micron ) make: jindal 18 providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with epdm rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer in charge . ( cost of aluminium snap beading shall be paid in basic item ) :with float glass panes of 5 mm thickness ( weight not less than 12.50 kg / sqm ) ( pin headed / plain ) make: saint gobian or modi 19 providing and fixing 9mm thick prelaminated particle board flat pressed three layer or graded wood particle board conforming to is: 12823 grade i type ii, in panelling fixed in aluminium doors, windows shutters and partition frames with c.p brass / stainless steel screws etc. complete as per architectural drawings and directions of engineer in charge. pre laminated particle board with decorative lamination on both sides.make: novapan 20 providing and fixing brass 100mm mortice latch and lock with 6 levers without pair of handles ( best make of approved quality ) for aluminium doors including necessary cutting and making good etc. complete.make: godrej 21 providing and fixing aluminium extruded section body tubular type universal hydraulic door closer ( having brand logo with isi, is : 3564, embossed on the body, door weight upto 36 kg to 80 kg and door width from 701 mm to 1000 mm ) , with double speed adjustment with necessary accessories and screws etc. complete.make: godrej 22 providing and fixing aluminium hanging floor door stopper, isi marked, anodised ( anodic coating not less than grade ac 10 as per is : 1868 ) transparent or dyed to required colour and shade, with necessary screws etc. complete.twin rubber stopper 23 providing and fixing 220mm long tubular ss handlemake: ozone ( h type or d type ) 24 providing and fixing aluminium tower bolts isi marked anodised ( anodic coating not less than grade ac 10 as per is : 1868 ) transparent or dyed to required colour or shade with necessary screws etc. complete:100x10 mm 25 filling the gap in between aluminium frame & adjacent rcc / brick / stone work by providing weather silicon sealant over backer rod of approved quality as per architectural drawings and direction of engineer in charge complete.upto 5mm depth and 5 mm width 26 providing and fixing white vitreous china laboratory sink with c.i. brackets, c.p. brass chain with rubber plug, 40 mm c.p brass waste and 40mm c.p. brass trap with necessary c.p. brass unions complete, including painting of fittings and brackets, cutting and making good the wall wherever required : size 600x450x200 mmmake: cera / parryware / hindware 27 providing and fixing three way swan neck tapmake: hindware 28 providing and fixing cp coated brass angle cock15 mmmake: onida 29 providing and fixing p.v.c. waste pipe for sink or wash basin including p.v.c. waste fittings complete.flexible pipe32 mm diamake: onida 30 providing and fixing uplasticised pvc connection pipe with brass unions :45 cm length15 mm nominal boremake: water tech 31 applying priming coats with primer of approved brand and manufacture, having low voc ( volatile organic compound ) content.with water thinnable cement primer on wall surface having voc content less than 50 grams / litremake: asian 32 wall painting with premium acrylic emulsion paint of interior grade, having voc ( voatile organic compound ) content less than 50 grams / litre of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour:two coatsmake: asian / nerolac / dulux 33 disposal of building rubbish / malba / similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by engineer in charge, beyond 50 m initial lead for all lead upto 10 kms including all lifts involved. 34 electrical works 35 suppling and fixing 16 module, 2 rows x 8, gi box ( minimum size: 232.8 x 147.4 x 61.2mm ) along with modular base & cover plate for items as mentioned in item no: 1 in recess ( in brick wall and making good the damage ) etc. as required in single line alignment from the ground at a height as advised by the project in charge, electrical. all the items mentioned in item no:1 has to be fixed in each modular plate as sets and internal wiring for the switches, sockets etc are to be done with 4.0 sq.mm frls wires for phase, neutral and earth. red / yellow / blue color wire for phase, black for neutral and green colour for earth. wire make: havells / finolex / v guard. modular base & cover plate make & model: same as item no:2.07. 36 suppling and fixing 16 module, 2 row x 8, pvc box ( minimum size: 245.2 x 172 x 45mm ) along with modular base & cover plate for items as mentioned in item no: 1 in recess ( in brick wall and making good the damage ) etc. as required in single line alignment from the ground at a height as advised by the project in charge, electrical. all the items mentioned in item no:1 has to be fixed in each modular plate as sets and internal wiring for the switches, sockets etc are to be done with 4.0 sq.mm frls wires for phase, neutral and earth. red / yellow / blue color wire for phase, black for neutral and green colour for earth. wire make: havells / finolex / v guard. modular base & cover plate make: same as the make and model of item no:2.07. 37 suppling and fixing of c curve, 240 / 415v phase ac, 50hz, 2 pole modular type 32 a mcb having a breaking capacity of 10ka in the existing modular plate. the output control wires from the mcb to the switches are to be done with 4.0 sq.mm frls wires for both phase & neutral. red / yellow / blue color wire for phase and black for neutral. wire make: havells / finolex / v guard. modular mcb make: priority should be given same as the make of item no:2.07. in case of unavailability in the market, any standard make with isi mark to fix. 38 supply, commissioning, testing and successful installation of 2 feet x 2 feet 36 watt led light fitting ( day colour lighting ) complete with all fittings, suitable for grid / false ceiling completeset including required length of internal wiring with rated 2 core copper wire to work with 240v single phase, 50hz ac supply. make: philips / wipro / havells. 39 dismantling & taking down wiring with all fittings, fixtures and old existing main switch board / distribution board after carefully disconnecting the incoming electrical input for the said room and depositing all the old materials to e & mm store yard or to a specified location within standard distance as advised by the electrical officer in charge of the project. 40 labour charges for digging upto 10 feet, fixing the item no:2.08, refilling of soil ( along with charcoal / coke and salt from item no:2.08 as required. 41 supplying and fixing following modular switch / socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.make: legrand / schneider / crabtree / leon / indo asiana ) 5 / 6 a switch 2 nos b ) 3 pin 5 / 6 a socket outlet 2 nos c ) 15 / 16 a switch 2 nos d ) 6 pin 15 / 16 a socket outlet 2 nos. 42 earthing with copper earth plate 600 mm x 600 mm x 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal / coke and salt as required. note: masonry enclosure size is 1.5 feet x 1.5 feet x 1.5 feet.as per is 3043, charcoal / coke and salt should be refilled with 50 kg each per earthpit. the copper plate has to be tinned, connected copper flats have to be brazed and only ss nut, bolts and washers to be used. 43 providing and fixing 25 mm x 5 mm copper strip in 40 mm dia g.i.pipe from earth electrode including connection with brass nut, bolt, spring, washer excavation and re filling etc. as required. 44 providing and fixing 4.00 mm dia copper wire on surface or in recess for loop earthing along with existing surface / recessed conduit / submain wiring / cable as required. 45 providing and fixing earth bus of 50 mm x 5 mm copper strip on surface for connections etc. as required. 46 supplying and fixing of following sizes of medium class pvc conduit along with accessories in surface / recess including cutting the wall and making good the same in case of recessed conduit as required. pvc conduit make: vip / joegeetha / supreme ( i ) 25 mm 47 supplying and fixing following modular switch on the existing modular plate & switch box including connections but excluding modular plate etc. as required. make & model: same as item no: 2.075 / 6 a switch 48 supplying and fixing following modular switch on the existing modular plate & switch box including connections but excluding modular plate etc. as required. make & model same as item no: 2.0715 / 16 a switch 49 suppying and fixing following size / modules, gi box alongwith modular base & cover plate for modular switches in recess etc. as required. make & model same as item no: 2.074 module ( 125mm x 75mm ) 50 suppying and fixing following size / modules, gi box alongwith modular base & cover plate for modular switches in recess etc. as required. make & model same as item no: 2.076 module ( 200mm x 75mm ) 51 wring for circuit / submain wiring alongwith earth wire with the following sizes of frls pvc insulated copper conductor, single core cable in surface / recessed medium class pvc conduit as required. wire make : havells / finolex / standard / v guard. pvc conduit make: vip / joegeetha / supreme.2 x 1.5 sq.mm + 1 x 1.5 sq.mm earth wire 52 wring for circuit / submain wiring alongwith earth wire with the following sizes of frls pvc insulated copper conductor, single core cable in surface / recessed medium class pvc conduit as required. wire make : havells / finolex / standard / v guard. pvc conduit make: vip / joegeetha / supreme. 2 x 2.5 sq. mm + 1 x 2.5 sq. mm earth wire 53 wring for circuit / submain wiring alongwith earth wire with the following sizes of frls pvc insulated copper conductor, single core cable in surface / recessed medium class pvc conduit as required. wire make : havells / finolex / standard / v guard. pvc conduit make: vip / joegeetha / supreme. 2 x 4 sq. mm + 1 x 4 sq. mm earth wire 54 wring for circuit / submain wiring alongwith earth wire with the following sizes of frls pvc insulated copper conductor, single core cable in surface / recessed medium class pvc conduit as required. wire make: havells / finolex / standard / v guard. pvc conduit make: vip / joegeetha / supreme.2 x 6 sq. mm + 1 x 6 sq. mm earth wire 55 wring for circuit / submain wiring alongwith earth wire with the following sizes of frls pvc insulated copper conductor, single core cable in surface / recessed medium class pvc conduit as required. wire make : havells / finolex / standard / v guard. pvc conduit make: vip / joegeetha / supreme.4 x 10 sq. mm + 2 x 6 sq. mm earth wire 56 wring for circuit / submain wiring alongwith earth wire with the following sizes of frls pvc insulated copper conductor, single core cable in surface / recessed medium class pvc conduit as required. wire make : havells / finolex / standard / v guard. pvc conduit make: vip / joegeetha / supreme.4 x 16 sq. mm + 2 x 6 sq. mm earth wire 57 supplying and drawing following sizes of frls pvc insulated copper conductor, single core cable in the existing surface / recessed steel / pvc conduit as required. wire make: havells / finolex / standard / v guard.pvc conduit make: vip / joegeetha / supreme. 2 x 6 sq. mm 58 supplying and fixing metal box of following sizes ( nominal size ) on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc. as required.100 mm ( l ) x 100 mm ( h ) x 60 ( d ) mm deep 59 supplying and fixing suitable size gi box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5 / 6 a & 15 / 16 a modular socket outlet and 15 / 16 a modular switch, connections etc. as required. make & model for modular plate & cover: same as item no: 2.07 60 supplying & fixing suitable size gi box with modular plate and cover in front on surface or in recess including providing and fixing 25 a modular socket outlet and 25 a modular sp mcb, c curve including connections, paiting etc. as required. make & model for modular plate & cover: same as item no: 2.07 61 supplying and fixing following rating, double pole, ( single phase and neutral ) , 240 v, residual current circuit breaker ( rccb ) , having a sensitivity current 30 ma in the existing mcb db complete with connections, testing and commissioning etc. as required.make: legrand / schneider / abb / l&t25 amps 62 supplying and fixing following rating, double pole, ( single phase and neutral ) , 240 v, residual current circuit breaker ( rccb ) , having a sensitivity current 30 ma in the existing mcb db complete with connections, testing and commissioning etc. as required.make: make: same as item no: 2.27 40 amps 63 supplying and fixing following rating, four pole, ( three phase and neutral ) , 415 volts, residual current circuit breaker ( rccb ) , having a sensitivity current 30 ma in the existing mcb db complete with connections, testing and commissioning etc. as required. make: same as item no: 2.2763 amps 64 supplying and fixing 30 a, 415 v, tpn industrial type socket outlet, with 4 pole and earth, metal enclosed plug top alongwith 30 a, “c” curve, tpmcb, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required. make: same as item no: 2.27 65 supplying and fixing 4 way ( 4 + 12 ) , double door, horizontal type three pole and neutral, sheet steel, mcb distribution board, 415 v, on surface / recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. ( but without mcb / rccb / isolator ) . make: same as item no: 2.27...

Karnataka Power Corporation Limited - Karnataka

34164012 procurement of 220kv clamp connectors , twin moose line asmb 245kv la, twin moose line asmb 400kv la, clamp 203, clamp 206, clamp 219, clamp 209a, clamp no 409a, clamp no 405a, clamp 204a, clamp 212, clamp 223, clamp 502a, clamp no 414a, clamp no 420, clamp no 508, clamp no 520a, fired wedge connector, 2 hole lynx paddle clamp, 4 hole lynx paddle clamp, pg clamp 11kv coyote, 11kv acsr conductor, pad clamp 11kv rabbit, bi metalic sheet, p.g. clamp for lynx acsr, cleat clamp for gi shieldwire, pg clamp for gi shield wire, tee connector for lynx acsr, terminal connector on isolator, rigid connector for al. tube, connector lynx on isolator, connector for al. tube on cb, rigid connector al, tube on ct, rigid connectoe al tube on pt, rigid type connt al tube on pt, rigid / sliding type connector, expansion terminal connector, angular tee connector al tube, inverted vee connector, corona bell for 2.5inchipsal tube, welding sleeve for 2.5inchaltube, pad connt for gi earth wire...

South Western Railway - Karnataka

33033840 supply of come along clampcome along clamp,come along clamp for (19/2.5 mm (earth wire (glav. steel) capacity 2.5 ton. dia 12.50mm as per rly approved drg. no im/acac/04/12/105 make im or sste or similar...

South Western Railway - Karnataka

32779939 supply of come along clampcome along clamp,come along clamp for (19/2.5 mm (earth wire (glav. steel) capacity 2.5 ton. dia 12.50mm as per rly approved drg. no im/acac/04/12/105 make im accepted make: sste...

South Western Railway - Karnataka

32428181 supply of come along clampcome along clamp,come along clamp for (19/2.5 mm (earth wire (glav. steel) capacity 2.5 ton. dia 12.50mm as per rly approved drg. no im/acac/04/12/105 make im accepted make: sste...

Karnataka Power Corporation Limited - Karnataka

32284094 supply of fire wedge connectors, palm connectors, rigid al. tubular conductor for svp, kpcl, jogfalls 577435 supply of fire wedge connectors, palm connectors, rigid al. tubular conductor for svp, kpcl, jogfalls 577435 , fire wedge connectors, wedge connector al conductor, palm connectors 4 hole paddle, rigid al tubular conductor 220, connector drake & 2.5 al tube, exapnsion connector 3 al tube, connector acsr drake conductor, gt hv bushing connector, gt neutral bushing connector, interconnector 3 2.5 al tube, connector for 123kv la 2.5, exp connector 3 al horizontal, exp connector 2.5 al horiznta, exp connector 2.5 al horizont, c type wedge connector paddle, palm connector for studd 30mm, neutral bus bpi 2.5 al tube, earth wire tension clamp 7 / 3.6, pad clamp 7 / 3.65mm gshieldwire, cleat clamp 7 / 3.65mm gshield, corona bell 2.5 al tube, corona bell 3 al tube, paddle clamp 1400amps, tension string turn buckle, bimetalic strip ( cu al ) , bimetalic strip ( cu al ) 2mm, frp earthing / discharge rods, earthing rod for 220kv yard, 110 kv acsr lynx conductor...

Karnataka Power Corporation Limited - Karnataka

32054011 supply of 220kv clamp connectors procurement of 220kv clamp connectors , twin moose line asmb 245kv la,twin moose line asmb 400kv la,clamp 203,clamp 206,clamp 219,clamp 209a,clamp no 409a,clamp no 405a,clamp 204a,clamp 212,clamp 223,clamp 502a,clamp no 414a,clamp no 420,clamp no 508,clamp no 520a,fired wedge connector,2 hole lynx paddle clamp,4 hole lynx paddle clamp,pg clamp 11kv coyote,11kv acsr conductor,pad clamp 11kv rabbit,bi metalic sheet,p.g. clamp for lynx acsr,cleat clamp for gi shieldwire,pg clamp for gi shield wire,tee connector for lynx acsr,terminal connector on isolator,rigid connector for al. tube,connector lynx on isolator,connector for al. tube on cb,rigid connector al,tube on ct,rigid connectoe al tube on pt,rigid type connt al tube on pt,rigid/sliding type connector,expansion terminal connector,angular tee connector al tube,inverted vee connector,corona bell for 2.5inchipsal tube,welding sleeve for 2.5inchaltube,pad connt for gi earth wire...

Karnataka Power Corporation Limited - Karnataka

31556468 supply of 220kv clamp connectors =1 twin moose line asmb 245kv la 2 twin moose line asmb 400kv la 3 clamp 203 4 clamp 206 5 clamp 219 6 clamp 209a 7 clamp no 409a 8 clamp no 405a 9 clamp 204a 10 clamp 212 11 clamp 223 12 clamp 502a 13 clamp no 414a 14 clamp no 420 15 clamp no 508 16 clamp no 520a 17 fired wedge connector 18 2 hole lynx paddle clamp 19 4 hole lynx paddle clamp 20 pg clamp 11kv coyote 21 11kv acsr conductor 22 pad clamp 11kv rabbit 23 bi metalic sheet 24 p.g. clamp for lynx acsr 25 cleat clamp for gi shieldwire 26 pg clamp for gi shield wire 27 tee connector for lynx acsr 28 terminal connector on isolator 29 rigid connector for al. tube 30 connector lynx on isolator 31 connector for al. tube on cb 32 rigid connector al, tube on ct 33 rigid connectoe al tube on pt 34 rigid type connt al tube on pt 35 rigid / sliding type connector 36 expansion terminal connector 37 angular tee connector al tube 38 inverted vee connector 39 corona bell for 2.5inchipsal tube 40 welding sleeve for 2.5inchaltube 41 pad connt for gi earth wire...

Karnataka Neeravari Nigam Limited - Karnataka

31485707 supplying and installing of utm machine with necessary renovation for existing qgc no 1 building. tender title 1 ksrrb m200 15.1. dismantling of existing structures like culverts, bridges, retaining walls and other structure comprising of masonry, cement concrete, wood work, steel work, including t&p and scaffolding wherever necessary, sorting the dismantled material, disposal of unserviceable material and stacking the serviceable material with all lifts complete as per specifications. iii ) dismantling stone masonry.rubble stone masonry in mud mortar. morth specification no. 202 2 dismantling mangalore tiles roof and stacking the material within a radius of 50 meters. including cost of materials, labour, hom complete as per specifications. a.c. sheet roofing. 3 ksrb 2 2 : earthwork excavation by manual means for foundation of buildings, water supply and sanitary lines and electrical conduits etc, either in pits or in trenches 1.5m and above in width, in soil not exceeding 1.5 m. in depth including dressing the bottom and sides of pits and trenches, stacking the excavated soil clear from edges of excavation with lead upto 50 m. including breaking of clods complete as per specifications.ksrb 2 2.2 : do in hard soil. no. kbs 2.1 ( b ) i 2.3.5 4 ksrb 4 1.1: providing and laying in position plain cement concrete of mix 1:2:4 with opc @ 240kgs, with 40mm and down size graded granite metal coarse aggregates @0.878cum and fine aggregates @ 0.459cum machine mixed, concrete laid in layers not exceeding 15 ems. thick, well compacted, in foundation, including cost of all materials, labour, hom curing complete as per specifications specification no. kbs 4.1, 4.2 5 ksrb 4.9.2 : providing t.m.t steel reinforcement for r.c.c work including straightening, cutting, bending, hooking, placing in position, lapping and i or welding wherever required, tying with binding wire and anchoring to the adjoining members wherever necessary complete as per design ( laps, hooks and wastage shall not be measured and paid ) cost of materials, labour, hom complete as per specifications. specification no. kbs 4.6.3 tmt bars fe 500 6 ksrb 4.2.8: providing and laying in position reinforced cement concrete of design mix m20 with opc @ 320kgs, with 20mm and down size graded granite metal coarse aggregates @0.69cum and fine aggregates @ 0.46cum, with super plasticisers @31ts confirming to is9103 1999 reaffirmed 2008, machine mixed, concrete laid in layers not exceeding 15 ems thick, vibrated for all works in ground floor level for roof slabs, staircase, lintels, and beams retaining walls, return walls, walls ( any thickness ) including attached pilasters, columns, 7 ksrb 6 1 : providing and constructing burnt brick masonry for basement and superstructure with approved quality of non modular bricks of standard size of class designation 3.5 newton per sqm with cement mortar including cost of materials, labour charges, scaffolding, curing complete as per specifications. specification no. kbs 6.2 with cement mortar 1:6 8 ksrb15 3 : providing 15mm thick cement plaster in single coat with cement mortar to brick masonry including rounding off corners wherever required srnooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications. 9 fabricating, supplying & erecting m.s.angular truss for all spans as per approved designs and drawing. the entire truss is anchored suitably by using 4 nos. of m.s. anchor bolts at each support, with base plate and shoe plate. the work includes cutting, straightening, placing in position of m.s angle and welding wherever necessary, and applying one coat of red oxide primer coat to all the members including cost of all materials, labour charges, & hire charges of machineries for cutting, welding, grinding & erection equipments, etc , complete as per specification 10 providing and installing of pre painted galvalume iron trapezoidal profiled sheet of approved make 1060 mm width ( 1000 mm cover width ) , 28 30 mm crest height with crest distance of 200 mm c / c with 2 ribs at the centre for stiffening. the total coated thickness ( tct ) of the sheet will be 0.47 mm + / 0.02 mm tolerance zinc aiu alloy coating az150 gsm as per astm 1397 / a755 550 mpa steel grade, 5 7 microns epoxy 11 ksrb 15 15.1 providing and applying painting in two coats with plastic emulsion paint of approved brand on wall surface to give an even approved shade after thoroughly brushing the surface, free from mortar drops and other foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour, complete as per specifications. with primer 12 supplying and fixing regular mccb distribution panel confirming to is 8828, on wall / wood board / flush mountingusing required clamps, bolts, nuts, etc., with provision for fixing of suitable type capacity mccbs as an incomer for 3 phase double door with necessary bus bar completely wired to use on 440volts 3phase 4 wire powder coated painting etc., complete with a provision for fixing of single / three phase suitable capacity mccb / mcbs as outgoings confirming to is8828. 13 supplying and fixing miniature circuit breakers on existing mcb distribution boards using necessary fixing materials and c type curve, indicator on / off, energy cross 3 with short circuit breaking capacity of 10k and complete wiring as required confirming to iec 60898. 40 amps sp 14 supplying and fixing miniature circuit breakers on existing mcb distribution boards using necessary fixing materials and c type curve, indicator on / off, energy cross 3 with short circuit breaking capacity of 10k and complete wiring as required confirming to iec 60898. 50 63amps tpn 15 supplying and fixing moulded case circuit breaker ( mccb ) over the existing wood / panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. protection of overload and short circuit with thermal magnetic / micro processor release and earth fault as per is 13947. ( icu = ics ) 125 amps 25ka. 16 supplying and fixing of metal socket set of 2pole and earth plugs and socket for incorporating sp and tp mcb ( without mcb ) . the entire plug and socket shall be mounted in a thermoplastic / powder coated metal box & wired completely 30amps. 17 supplying heavy gauge pvc conduit pipe …….dia .......mm thick confirming to is 2509 with suitable size bends, junction boxes, adhesive paste etc., and fixing using inverted wood plugs in case of rcc ceiling and rcc wall / stone structure or rawl plugs in case of brick walls and cement plastering the damaged portion using heavy gauge saddles at an interval of 700mm using nf screw 32mm dia 2.5mm thick. 18 supplying pvc / gi flexible conduit pipe…mm dia fixing on surface over inverted tapered wooden plugs or phill plugsor rawl plugs and clamped using heavy gauge saddles at an interval of 300mm using nf screws and on either end of the pipe terminated completely 25mm 19 supplying and wiring adopting loop system in existing pvc conduit / casing capping using 2x1.5sqmm ( phase & neutral ) & 1x1.0 sqmm ( earth wire ) frls multi strand pvc insulated copper wire ( confirming to is 694: and latest amendments ) with a 6amps flush type sp control switch shall be fixed on the existing plastic sheet / gang box, the other end of the wires shall be terminated with sufficient loose length in a wood / pvc round block. complete for each outlet. three outlet in a row, above 6mts upto 10mtr from tapping point to out let via switches 20 wiring for lighting / power circuit using one of frls pvc insulated 1100v grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified is 694:confirming to latest amendments. ( 1.5 sqmm ) 21 wiring for lighting / power circuit using one of frls pvc insulated 1100v grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified is 694:confirming to latest amendments. ( 10 sqmm ) 22 wiring for lighting / power circuit using one of frls pvc insulated 1100v grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified is 694:confirming to latest amendments. ( 4 sqmm ) 23 supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal / pvc box. ( 6 module ) 24 supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal / pvc box. ( 12 module ) 25 supplying and fixing surface / flush mounting unbreakable pvc modular box suitable for mounting modular switch plates with due groove cutting in brick / c.c wall, including necessary rawl plugs, machine / nf screws etc., complete. ( 6 way ) 26 supplying and fixing surface / flush mounting unbreakable pvc modular box suitable for mounting modular switch plates with due groove cutting in brick / c.c wall, including necessary rawl plugs, machine / nf screws etc., complete. ( 12 way ) 27 supplying and fixing / replacing of 6 / 16 / 32amps electrical accessories on existing switch board. ( 6amps sp switch ) 28 supplying and fixing / replacing of 6 / 16 / 32amps electrical accessories on existing switch board. ( 6amps 3 way 5 pin socket ) 29 supplying and fixing / replacing of 6 / 16 / 32amps electrical accessories on existing switch board. ( 6amps bakelite ceiling rose ) 30 supplying and fixing / replacing of 6 / 16 / 32amps electrical accessories on existing switch board. ( 16 amps sp switch ) 31 supplying and fixing / replacing of 6 / 16 / 32amps electrical accessories on existing switch board. ( 16 / 6 amps combined plug and socket ) 32 supplying and fixing / replacing of 6 / 16 / 32amps electrical accessories on existing switch board. ( electronic stepped regulator. ) 33 supplying and fixing / replacing of 6 / 16 / 32amps electrical accessories on existing switch board. ( 3 phase industrial sockel and plug for moters ) 34 supplying and fixing regular mcb distribution boards on wall / wood board / flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity mcbs single phase / 3 phase / single door with powder coated painting. made out of 14 swg ms enclosure. 12 way spn db 35 supplying, fixing and wiring residual current circuit breaker ( rccb ) 240 / 450v up to 300ma sensitivity on existing wood / panel board. 63 amps 2 pole 36 supplying of ......feet pvc batten with integrated led tube .....w with high quality diffuser with life of 25000 burning hours & 70% lumen maintenance with cri > 80. power input: 220 240v @ 50 / 60hz & power factor >0.9 along with ce approved. 2 years warranty against any manufacturing defect working under standard electrical condition. led light fitting 1 x 4 20 / 22 watt 37 utm machine techinical specifications in annexure 1...

Karnataka Power Transmission Corporation Limited - Karnataka

30385333 providing additional 1x12.5mva, 66 / 11kv power transformer at 66 / 11kv hosapalya circle sub station in magadi taluk, ramanagara dist., on total turnkey basis including supply of all materials / equipment and erection ( including civil works ) of all materials / equipments, testing and commissioning on total turnkey basis. ss1 power transformer : 12.5mva, 66 / 11kv delta / star, dynll, 3ph, 50 hz, core type winding with oltc, rtcc panel, etc., complete filled with transil oil with 10% spare oil with the terminal connectors suitable for drake acsr on the primary and secondary and neutral connectors suitable 66kv side and drake acsr / 2 nos of 50x8mm copper flat for each phase from lv side of tranformer to vable at 11kv side cable terminating structure with suitable support insulator on lv side of transformer and 2 nos. of 50mmx8mm copper flats from neutral terminal to earthmat through nct along with necessary support pin insulators ( 37mt ) . ss2 circuit breaker: sf 6 circuit breaker with semi pneumatic.pneumatic operated / spring type operating mechanism, including mounting structure with rigid, bi metallic terminal connector suitable for single drake acsr conductor and mounting structure i 66 kv, 1250 a, 31.5ka sf6 cb: for power transformer ( with capacitive trip device ) ss3 isolator: i isolator: isolators including marshalling box and suitable terminal connectors, as required as per technical specification with solid core cylindrical post insulators:66 kv, 1250 a, 31.5 ka class double break manually operated isolator with terminal connectors suitable for drake acsr:upright mounting type without earth switch. lph 4600mm. ii 11 kv isolators: a 11kv isolators, double break 400a, 25ka capacity with rigid bi metallic terminal connectors suitable for coyote acsr for capacitor bank. b 11kv isolators, single break 400a, 25ka capacity with rigid bi metallic terminal connectors suitable for coyote acsr for outgoing feeders. ss4 current transformer: current transformer: current transformer including marshalling box, single phase, oil filled outdoor type with rigid bimetallic terminal connectors suitable for drake acsr conductor. 1 66kv class, 31.5 ka, ct of ratio 200 100 / 1 1 1a for transformer. for metering: accuracy 0.2s, burden 10 va for backup protection: accuracy 5p20. burden 30 va for differential / distance protection ps class accuracy class, vk 800v, rct 2 ohm at 200 / 1a 2 11kv class, 25 ka, nct of ratio 1200 800 / 1 1 1a for refr protection ( of similar rating and ratio as that of incomer of 11kv switch gear ) with terminal connector suitable for 2nos of 50x8mm copper flats. note: 1 ) all the cts in each kv class shall be of one and the same make for inter changeability & reliability of performance. 2 ) the make and characteristics of 11kv nct should be the same as that of the incomer ct of 11kv switchgear to ensure this, the 11kv nct should be procured from the supplier of 11kv switchgear only. ss5 surge arrestor ( ( procelain housing ) metal oxide, gapless type, as per technical specification ) 1 60kv, 10ka, class ii normal duty 2 9kv, 10ka class ss6 capacitor bank:design, engineering, supply erection ( including civil works ) testing and commissioning of 2.9mvar 12.1kv capcitor bank, sar connected double bank with internal fuses, terminal connectors with suitable neutral ct and station class las, 0.2% series reactor s db isolators with iso / cable mounting structures on neutral side with mounting strcutures for nct, capcitor bank, station class las, series reactor etc., omplete as per specification ( including testing & commissiong ) ss7 control and relay panel complete: simplex type control & relay panel complete as per specifictaions: for 66 / 11kv transformer note: 1 ) all c&r panels and associated panels shall be one and same make for uniformity and interchangeability of components. 2 ) the accuracy class metering cts & vts & etv meter of c&r panels shall be 0.2s accuracy class irrespective of what has been indiacted else where in the bid document. ii ) the electronic tri vector meters with abt & tod features & dlms comaplint / protocol energy meter has to be provided. ss8 station structures: 1 11kv ods & take off strcuture: supplying & ercetion of dp strcuture with all accessories using 9.0 mters long 145kg wl suitable for , ounting gos. ss9 gi mounting structures : including bolts & nuts ( lattice type ) 1 66 kv isolators lph 4600mm. ( 0.76mt / structure ) 2 66kv current transformer & 11kv ncts. ( 0.149mt per structure ) 3 66kv lightning arrestors. ( 0.072 mt per structure ) 4 66kv pedestal insulators: a pedestal insulators ( for 66 kv bus ) . ( 0.147mt / strcuture ) b 66kv high pedestal insulatorsfor ( for transfomer ) ( 0.231mt / structure ) 5 11kv cable terminating structures for lv side of 66 / 11 kv tr. ( 0.072mt / structure ) 6 11kv cable raising ( support ) structures for capacitor bank ( 0.062mt ) 7 structure for 11kv isolator for capacitor bank ( 0.131mt ) ss10 bus bar formation: 1 drake acsr 2 earth wire 7 / 3.15mm steel with clamps / lugs ss11 insulators :post insulator cyindrical solid core as per iss5350, part ii & iii: 66kv class, 1 unit / stack ss12 hardwares: 1 c type wedge connector suitable for drake drake ( bus ) 2 post insulator clamp suiatble for single drake acsr and 66kv solid core insulator ss13 copper control cable : 1.1 kv class pvc insulated copper control cable with lugs / ferrules / glands as per techinical specifications. 1 19 core 2.5 sq.mm copper control cables. 2 4 core 6 sq.mm copper control cables. 3 4 core 2.5 sq.mm copper control cables. 4 2 core 2.5 sq.mm copper control cables. 5 2 core 6 sq.mm copper control cables. ss14 switchgear: 1 11kv, 500mva, 25ka metal clad vcb switchgear ( 1600a for incomer and 1250a for feeders ) outdoor type, each comprising of 1ic+6f+1bc+2cb+1ap ( remote announciation cum control panel ) with cts & pts & terminal connector suitable for drake / coyote acsr etc., complete as per technical specification. note: 1. simplex type annuncitor panel shall be provided for switch gear ( consisting of incommer, feeders and bus coupler ) . 2. for capcitor bank: the capacitor bank panel shall be same as that of provided in the i / c, the following panel in all respect. in addition to relays provided in the i / c, the follwoing additional relays to be provided. i ) circulatinf current relay with timer ii ) under voltage relay iii ) timer relay. 2 materials for new bay integration to existing scada panel: i multi functional transducer ( mft ) 0.2s class including labour ii opto coupler ( 220 or 110v dc ) including labour iii current cable copper core with 4.0sqmm cross section mutlistrand 7 core for ct termination iv voltage cables copper core with 2.5sqmm cross section mutlistrand 4 core for pt termination v signal / communication cables armoured copper core with 0.5sqmm cross section mutlistrand 10core vi control cables copper core with 1.5sqmm cross section mutlistrand 10 core vii rj 45 cable for energy meter integration to dcu ss15 11 kv xlpe insulated ug cable: a 11kv xlpe cable 1000sqmm aluminium cable from 66 / 11kv transfomer to 11kv switchgear. b 11kv xlpe cable 240sqmm aluminium cable 3 core to be run from 11kv switchgear to 11kv takeoff dp strcuture / capacitor bank c cable termination kits suitable for following sizes as per technical specification: i 1000sqmm single core: a indoor type b outdoor type ii 240sqmm single core: a indoor type b outdoor type ss16 nitrogen injection fire protection system: nitrogen injection fire protection system incluidng civil engineering work like soak pit etc., as per the recommendaion of the supplier of the fire fighting system with necessary mounting stand for 12.5mva power transformer. ...

Rural Development Panchayath Raj Engineering Department - Karnataka

28248547 installation of 8 member capacity elevetor (lift) in taluk panchayath office at mini vidhana soudha, ramanagara town & dist. (design, supply & installation of 1 no. lift of 8 passenger capacity for b+g+2 floors, including all civil and electrical works on turnkey basis and comprehensive annual maintenance including all kinds of routine preventive & corrective (breakdown) maintenance for one year) 1. supplying and wiring adopting loop system in existing pvc conduit /casing capping using 2x1.5sqmm (phase & neutral) & 1x1.0 sqmm (earth wire) frls multi strand pvc insulated copper wire (confirming to is 694: and latest amendments) with a 6amps flush type sp control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/pvc round block. complete for each outlet. medium point above 3mtr upto 6mtr from tapping point to out let via switch, 2. wiring for lighting/power circuit using one of frls pvc insulated 1100v grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified is 694:confirming to latest amendments. 1.5 sqmm., 3. 2.5 sqmm., 4. supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. the box should be firmly flush mounted after due groove cutting in brick/stone/c.c wall. 6way, 5. supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/pvc box. 6 module, 6. supplying and fixing of modular switch & connected accessories on existing modular switch plate. 6amps one way switch, 7. 6amps 3way socket, 8. supplying and fixing miniature circuit breakers on existing mcb distribution boards using necessary fixing materials and c type curve, indicator on/off, energy cross 3 with short circuit breaking capacity of 10k and complete wiring as required confirming.50 63amps tpn, 9. supplying, fixing and wiring earth leakage miniature circuit breaker (elmcb) 240/450v up to 300ma sensitivity on existing wood/panel board.63 amps 4 pole, 10. supply and installation / fixing / provision of outdoor type thermoplastic modular panel enclosure with transparent polycarbonate lid, shock proof, ip65 (weather proof), rust proof, dust proof, water proof, corrosion proof having internally embedded gasket on both lid and flap suitable to fix single phase / three phase energy meter in suitable base plate and having a provision for fuse / mcb cutout with suitable transparent hinged flap opening for operating mcb along with complete tamper proof sealing facility.600mmx600mmx170mm, 11. supplying fixing and wiring earth electrode for grounding of lifts, transformers, dg sets etc. using 40mm dia 2.9mm thick 2.5 mtr long gi pipe with gi funnel with mesh and suitable size reducer fixed on the top of the earth electrode. the funnel should be enclosed in a cc chamber of 400x400x400mm with a cast iron cover. the earth electrode shall have staggered holes of 12mm dia and the electrode should be covered 150mm all round with alternate layers of salt and charcoal from the bottom of the cc chamber. the connection from the electrode is to be established through gi strip using gi bolts and nuts.electrode, 12. supplying and running of gi/copper strips for grounding connections, using necessary fixing materials as required.25x3mm gi strip, 13. 25x3mm copper strip, 14. 600x600x3mm copper plate, 15. supplying of 1.1 kv lt ug cable xlpe or heat resistant pvc insulated, pvc extruded inner sheath armoured ug lt cable as per is 1554 (part 1) or is 7098 part 1, armouring strip thickness in average +5% and resistivity 14 ohms/kms.3.5 core 25 sqmm, 16. 3.5 core 35 sqmm, 17. supplying and running gi/copper conductor for grounding and (along with other wires in conduit system of wiring) using necessary suitable size clamps, nails, guttas/spacers. 8 swg copper wire., 18. supplying of ......feet pvc batten with integrated led tube .....w with high quality diffuser with life of 25000 burning hours & 70% lumen maintenance with cri > 80. power input: 220 240v @ 50/60hz & power factor >0.9 along with ce approved. 2 years warranty against any manufacturing defect working under standard electrical condition. led light fighting 1 x4 20/22 w, 19. supplying & fixing of retrofit type led bulb.......w with opal acrylic diffuser comprising of led source with cct 6500 degree k, cri> 70%. efficacy >80 lumen per watt, life> 25000 burning hours and compliance to is 10322/iec 60598, lm 79 & lm 80. the led are driven by hf electronic driver integrated in the system, with pf > 0.95, power loss should < 5% of lamp wattage., short circuit & open circuit protection to be integrated in the circuit, thd less than 20%, life as per lm 79. the operating input voltage should be between 130 to 275 volts. bis approved and tested by nabl/cpri accredited laboratory with 2 years warranty against any manufacturing defect working under standard electrical condition..12w, 6500k, 20. supplying and fixing of round or oblong type bulk head fitting glass cover., 21. design, supplying, erecting testing and commissioning of passenger/ bed cum passenger hospital lift with speed of 1mtr per second, variable voltage variable frequency drive, with or without machine room for the available well size, operating at 415 v 3 phase 50 cycles ac supply, powder coated / stainless steel car entrance doors enclosures with suitable colour vinyl flooring, led car illumination, emergency light, intercom and fan as desired by the user, central opening / side opening door with or without attendant operation, 7 segment display buttons, call register indicator, fireman drive, ss handrails inside car, full length infrared curtain in car door, automatic rescue device with batteries, voice announcing in regional / international languages, braille buttons with one year warranty and maintenance with necessary scaffolding and minor civil works like fixing of guide rail, counter weight etc., 8 passenger,4 stops, 22. dismantling of existing structures like culverts, bridges, retaining walls and other structure comprising of masonry, cement concrete, wood work, steel work, including t&p and scaffolding wherever necessary, sorting the dismantled material, disposal of unserviceable material and stacking the serviceable material with all lifts complete as per specifications. c. prestressed / reinforced cement concrete grade m 20 & above. morth specification.wall 3*2.00*0.45*0.90 = 2.43 cum, ...

Rural Development Panchayath Raj Engineering Department - Karnataka

27826746 installation of 8 member capacity elevetor (lift) in taluk panchayath office at mini vidhana soudha, ramanagara town & dist. (design, supply & installation of 1 no. lift of 8 passenger capacity for b+g+2 floors, including all civil and electrical works on turnkey basis and comprehensive annual maintenance including all kinds of routine preventive & corrective (breakdown) maintenance for one year) 1. supplying and wiring adopting loop system in existing pvc conduit /casing capping using 2x1.5sqmm (phase & neutral) & 1x1.0 sqmm (earth wire) frls multi strand pvc insulated copper wire (confirming to is 694: and latest amendments) with a 6amps flush type sp control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/pvc round block. complete for each outlet. medium point above 3mtr upto 6mtr from tapping point to out let via switch, 2. wiring for lighting/power circuit using one of frls pvc insulated 1100v grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified is 694:confirming to latest amendments. 1.5 sqmm., 3. 2.5 sqmm., 4. supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. the box should be firmly flush mounted after due groove cutting in brick/stone/c.c wall. 6way, 5. supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/pvc box. 6 module, 6. supplying and fixing of modular switch & connected accessories on existing modular switch plate. 6amps one way switch, 7. 6amps 3way socket, 8. supplying and fixing miniature circuit breakers on existing mcb distribution boards using necessary fixing materials and c type curve, indicator on/off, energy cross 3 with short circuit breaking capacity of 10k and complete wiring as required confirming.50 63amps tpn, 9. supplying, fixing and wiring earth leakage miniature circuit breaker (elmcb) 240/450v up to 300ma sensitivity on existing wood/panel board.63 amps 4 pole, 10. supply and installation / fixing / provision of outdoor type thermoplastic modular panel enclosure with transparent polycarbonate lid, shock proof, ip65 (weather proof), rust proof, dust proof, water proof, corrosion proof having internally embedded gasket on both lid and flap suitable to fix single phase / three phase energy meter in suitable base plate and having a provision for fuse / mcb cutout with suitable transparent hinged flap opening for operating mcb along with complete tamper proof sealing facility.600mmx600mmx170mm, 11. supplying fixing and wiring earth electrode for grounding of lifts, transformers, dg sets etc. using 40mm dia 2.9mm thick 2.5 mtr long gi pipe with gi funnel with mesh and suitable size reducer fixed on the top of the earth electrode. the funnel should be enclosed in a cc chamber of 400x400x400mm with a cast iron cover. the earth electrode shall have staggered holes of 12mm dia and the electrode should be covered 150mm all round with alternate layers of salt and charcoal from the bottom of the cc chamber. the connection from the electrode is to be established through gi strip using gi bolts and nuts.electrode, 12. supplying and running of gi/copper strips for grounding connections, using necessary fixing materials as required.25x3mm gi strip, 13. 25x3mm copper strip, 14. 600x600x3mm copper plate, 15. supplying of 1.1 kv lt ug cable xlpe or heat resistant pvc insulated, pvc extruded inner sheath armoured ug lt cable as per is 1554 (part 1) or is 7098 part 1, armouring strip thickness in average +5% and resistivity 14 ohms/kms.3.5 core 25 sqmm, 16. 3.5 core 35 sqmm, 17. supplying and running gi/copper conductor for grounding and (along with other wires in conduit system of wiring) using necessary suitable size clamps, nails, guttas/spacers. 8 swg copper wire., 18. supplying of ......feet pvc batten with integrated led tube .....w with high quality diffuser with life of 25000 burning hours & 70% lumen maintenance with cri > 80. power input: 220 240v @ 50/60hz & power factor >0.9 along with ce approved. 2 years warranty against any manufacturing defect working under standard electrical condition. led light fighting 1 x4 20/22 w, 19. supplying & fixing of retrofit type led bulb.......w with opal acrylic diffuser comprising of led source with cct 6500 degree k, cri> 70%. efficacy >80 lumen per watt, life> 25000 burning hours and compliance to is 10322/iec 60598, lm 79 & lm 80. the led are driven by hf electronic driver integrated in the system, with pf > 0.95, power loss should < 5% of lamp wattage., short circuit & open circuit protection to be integrated in the circuit, thd less than 20%, life as per lm 79. the operating input voltage should be between 130 to 275 volts. bis approved and tested by nabl/cpri accredited laboratory with 2 years warranty against any manufacturing defect working under standard electrical condition..12w, 6500k, 20. supplying and fixing of round or oblong type bulk head fitting glass cover., 21. design, supplying, erecting testing and commissioning of passenger/ bed cum passenger hospital lift with speed of 1mtr per second, variable voltage variable frequency drive, with or without machine room for the available well size, operating at 415 v 3 phase 50 cycles ac supply, powder coated / stainless steel car entrance doors enclosures with suitable colour vinyl flooring, led car illumination, emergency light, intercom and fan as desired by the user, central opening / side opening door with or without attendant operation, 7 segment display buttons, call register indicator, fireman drive, ss handrails inside car, full length infrared curtain in car door, automatic rescue device with batteries, voice announcing in regional / international languages, braille buttons with one year warranty and maintenance with necessary scaffolding and minor civil works like fixing of guide rail, counter weight etc., 8 passenger,4 stops, 22. dismantling of existing structures like culverts, bridges, retaining walls and other structure comprising of masonry, cement concrete, wood work, steel work, including t&p and scaffolding wherever necessary, sorting the dismantled material, disposal of unserviceable material and stacking the serviceable material with all lifts complete as per specifications. c. prestressed / reinforced cement concrete grade m 20 & above. morth specification.wall 3*2.00*0.45*0.90 = 2.43 cum, ...

Karnataka State Natural Disaster Monitoring Centre - Karnataka

27769012 supply and installation of equipment to establish seoc at ksndmc 1. 24 u rack or better, 2. amplifier and dsp, 3. cable cubbies, 4. desktop computer, 5. extra for fabrication supply and fixing of stand fabricated using slotted angle/l angle of size 6mm x 50mm for mounting out door/indoor a.c. unit./ batteries. complete with all lead & lifts complete as per specification and directions of the engineer in charge of the work., 6. extra for groove cutting in brick wall or cc floor to the suitable depth for concealing of conduit or gi pipe and plastering, finishing upto wall surface complete. upto 50mm conduit in brick wall complete with all lead & lifts complete as per specification and directions of the engineer in charge of the work., 7. fixing a ceiling / wall mounting fan of all capacities and all types, with necessary clamps and s hook made out of 15mm dia ms rod, with 5 amps. ceiling rose of approved quality with necessary length of 23 / 0.0076 inch pvc insulated twin twisted wire of approved quality, mounted on a suitable size wooden board and wired.(complete with all lead & lifts complete as per specification and directions of the engineer in charge of the work., 8. fixing a ceiling / wall mounting fan of all capacities and all types, with necessary clamps and s hook made out of 15mm dia ms rod, with 5 amps. ceiling rose of approved quality with necessary length of 23 / 0.0076 inch pvc insulated twin twisted wire of approved quality, mounted on a suitable size wooden board and wired.complete with all lead & lifts complete as per specification and directions of the engineer in charge of the work., 9. fixing all types and all capacities of fluorescent or false ceiling or spot light or cfl or led fittings indoor on the wall or ceiling or rafters or girders using 23/0.0076 inch twin twisted pvc insulated wires, required nos of round blocks and clamps. complete with all lead & lifts complete as per specification and directions of the engineer in charge of the work., 10. gooseneck mics, 11. groove cutting in walls supplying heavy gauge pvc conduit pipe with suitable size bends, metal junction boxes adhesive paste etc., by groove cutting in the wall and fixing by bracing u or j hooks and cement plastering up to the wall surface and run with 18 swg gi fish wire run throughout the conduit wherever necessary. 19/20mm dia 2mm thickcomplete with all lead & lifts complete as per specification and directions of the engineer in charge of the work., 12. groove cutting in walls supplying heavy gauge pvc conduit pipe with suitable size bends, metal junction boxes adhesive paste etc., by groove cutting in the wall and fixing by bracing u or j hooks and cement plastering up to the wall surface and run with 18 swg gi fish wire run throughout the conduit wherever necessary. 25mm dia 2mm thick complete with all lead & lifts complete as per specification and directions of the engineer in charge of the work., 13. groove cutting in walls supplying heavy gauge pvc conduit pipe with suitable size bends, metal junction boxes adhesive paste etc., by groove cutting in the wall and fixing by bracing u or j hooks and cement plastering up to the wall surface and run with 18 swg gi fish wire run throughout the conduit wherever necessary. 32mm dia 2.5mm thick complete with all lead & lifts complete as per specification and directions of the engineer in charge of the work., 14. installation charges for split type air conditioner, 15. open conduit system supplying heavy gauge pvc conduit pipe confirming to is 2509 with suitable size bends, junction boxes, adhesive paste etc., and fixing using inverted wood plugs in case of rcc ceiling and rcc wall / stone structure or rawl plugs in case of brick walls and cement plastering the damaged portion using heavy gauge saddles at an interval of 700mm using nf screws. 19 or 20mm dia 2mm thick. complete with all lead & lifts complete as per specification and directions of the engineer in charge of the work., 16. open conduit system supplying heavy gauge pvc conduit pipe confirming to is 2509 with suitable size bends, junction boxes, adhesive paste etc., and fixing using inverted wood plugs in case of rcc ceiling and rcc wall / stone structure or rawl plugs in case of brick walls and cement plastering the damaged portion using heavy gauge saddles at an interval of 700mm using nf screws. 25mm dia 2mm thick. complete with all lead & lifts complete as per specification and directions of the engineer in charge of the work., 17. open conduit system supplying heavy gauge pvc conduit pipe confirming to is 2509 with suitable size bends, junction boxes, adhesive paste etc., and fixing using inverted wood plugs in case of rcc ceiling and rcc wall / stone structure or rawl plugs in case of brick walls and cement plastering the damaged portion using heavy gauge saddles at an interval of 700mm using nf screws. 32 mm dia 2.5mm thick. complete with all lead & lifts complete as per specification and directions of the engineer in charge of the work., 18. providing and laying of modular wooden polished flooring of 12mm thick, high density timber of approved colour and design with end trims, transition, profiles, beading, 15mm thick felt, and 20 micron polyester film with 4mm thick foam underlay etc., including cost of all materials, mortar, labour, curing etc., complete as per specification. complete with all lead & lifts complete as per specification and directions of the engineer in charge of the work., 19. providing & fixing of mineral fibre acoustical suspended ceiling system in module size of 600 x 600 x 16mm with exposed grid. tiles having humidity resistance (rh) of 99%, nrc 0.5, light reflectance ;,83%, thermal conductivity k = 0.052 0.057 w/m k, colour white, fire performance uk class 0 i class 1 (bs 476 pt 6 &7)with sand texture finished dune and suitable for green building application with recycled content of 39%. the tile shall be laid on 24 mm wide t section flanges colour white having rotary stitching on all t sections i.e. the main runner, 1200 mm & 600 mm cross tees with a web height of 38mm and a load carrying capacity of 15kgs/sqm & pull out strength of minimum 100 kgs. the t sections should have a galvanizing of 90 grams per sqm and need to be installed with suspension system of approved make. complete with all lead & lifts complete as per specification and directions of the engineer in charge of the work., 20. providing and fixing straight workstation consisting of back to back unit made out of 75 mm thick ms crca powder coated, tile based system for main sprine, separator 25 mm thick plpb bsl wooden separator for return spine,top tile finish 8 mm thick mdf covered with fabric of approved colour and one writing board (600 mm w) and one soft board (600 mmw) per workstation, bottom tile finish 9 mm thick laminate tile of approved colour, raceway one middle raceway (600mm w) below table top per workstation and continous raceway at the skirting level, wire manager abs plastic grommet one number per table,table top 25 mm thick plpb with straight table top hardware ms powder coated corner bkt,cantilever bkt,separator hook on bkt, l bkt and table joint plate., as per specifications, drawings and as directed by engineer in charge. complete with all lead & lifts complete as per specification and directions of the engineer in charge of the work. d) size : 1200 mmw x 540mm d x 1200 mm ht (non sharing work station with post formed table top, single unit), 21. providing and fixing veneer paneling, over the 50mm x 35mm sal wood frame work at spacing not exceeding 60dmm c/c fixed to the wall and top covered out of 4mm thick approved quality veneer, fixed over 12mm thick ply of approved brand, termite and water resistant, finished with melamine polish, complete with all lead & lifts complete as per specification and directions of the engineer in charge of the work., 22. supply of round/square recess/surface mounted rolling type led down light with .w gu 10 led lamp rib fabricated from die cast aluminium with white powder coated prewired to mains connector & has swiveling unit of aluminium die cast eye ball & led lamp position retained by circular wire spring, with life of 25000 burning hours & 70% lumen maintenance with cri > 80. power input: 220 240v @ 50/60hz & power factor >0.9 along with ce approved. 2 years warranty against any manufacturing defect working under standard electrical condition led square or round down light 15 18wcomplete with all lead & lifts complete as per specification and directions of the engineer in charge of the work., 23. supplying & fixing of switch mounting rack with power manager & cable manager. 12 u with 450mm depth complete with all lead & lifts complete as per specification and directions of the engineer in charge of the work., 24. supplying & fixing of switch mounting rack with power manager & cable manager. supplying & fixing of fan complete with all lead & lifts complete as per specification and directions of the engineer in charge of the work., 25. supplying & fixing of switch mounting rack with power manager & cable manager. supplying & fixing of power strip complete with all lead & lifts complete as per specification and directions of the engineer in charge of the work., 26. supplying & fixing flexible led strip light .w power consumption in 5mtrs length cct 6500 degree k, cri> 70%. efficacy >80 lumen per watt, life> 25000 burning hours and compliance to is 10322/iec 60598, lm 79 & lm 80. the led are driven by hf electronic driver non integrated, with pf > 0.95, power loss should < 5% of lamp wattage., short circuit & open circuit protection to be integrated in the circuit, thd less than 20%, life as per lm 79. the operating input voltage should be between 130 to 275 volts. bis approved with 2 years warranty against any manufacturing defect working under standard electrical condition. complete with all lead & lifts complete as per specification and directions of the engineer in charge of the work., 27. supplying & fixing of cat6 patch cable1 mtr complete with all lead & lifts complete as per specification and directions of the engineer in charge of the work., 28. supplying & fixing of cat6 patch cable2 mtr complete with all lead & lifts complete as per specification and directions of the engineer in charge of the work., 29. supplying & fixing of patch panel for lan cabling 48 port 10/100 patch panel complete with all lead & lifts complete as per specification and directions of the engineer in charge of the work., 30. supplying pvc or gi flexible conduit pipe fixing on surface over inverted tapered wooden plugs or phill plugs or rawl plugs and clamped using heavy gauge saddles at an interval of 300mm using nf screws and on either end of thepi pe terminated completely 32mm complete with all lead & lifts complete as per specification and directions of the engineer in charge of the work., 31. supplying pvc/gi flexible conduit pipe fixing on surface over inverted tapered wooden plugs or phill plugs or rawl plugs and clamped using heavy gauge saddles at an interval of 300mm using nf screws and on either end of the pipe terminated completely 25mm complete with all lead & lifts complete as per specification and directions of the engineer in charge of the work., 32. supplying and drawing pvc flexible one pair telephone unarmoured tinned copper cable.complete with all lead & lifts complete as per specification and directions of the engineer in charge of the work., 33. supplying and drawing pvc flexible one pair telephone unarmoured tinned copper cable.complete with all lead & lifts complete as per specification and directions of the engineer in charge of the work., 34. supplying and drawing pvc insulated gas injected physical foam jelly flooded co axial tv cable.rg 6.complete with all lead & lifts complete as per specification and directions of the engineer in charge of the work., 35. supplying and fixing miniature circuit breakers on existing mcb distribution boards using necessary fixing materials and c type curve, indicator on/off, energy cross 3 with short circuit breaking capacity of 10k and complete wiring as required confirming to iec 60898. 6 32 amps sp. complete with all lead & lifts complete as per specification and directions of the engineer in charge of the work., 36. supplying and fixing of mdf krone junction box with krone module or telephone cable termination. 50 pair complete with all lead & lifts complete as per specification and directions of the engineer in charge of the work., 37. supplying and fixing of pvc casing and capping on the wall or ceiling using necessary materials like bends, screws at an interval of 300mm etc. as required.50 mm complete with all lead & lifts complete as per specification and directions of the engineer in charge of the work., 38. supplying and fixing of modular switch & connected accessories on existing modular switch plate as per is 3854 and is 1293. 16amps one way switch complete with all lead & lifts complete as per specification and directions of the engineer in charge of the work., 39. supplying and fixing of modular switch & connected accessories on existing modular switch plate as per is 3854 and is 1293. 32amps dp switch complete with all lead & lifts complete as per specification and directions of the engineer in charge of the work., 40. supplying and fixing of modular switch & connected accessories on existing modular switch plate as per is 3854 and is 1293. 6amps 3way socket. complete with all lead & lifts complete as per specification and directions of the engineer in charge of the work., 41. supplying and fixing of modular switch & connected accessories on existing modular switch plate as per is 3854 and is 1293. 6amps one way. complete with all lead & lifts complete as per specification and directions of the engineer in charge of the work., 42. supplying and fixing of modular switch & connected accessories on existing modular switch plate as per is 3854 and is 1293. rj45/ i.o. outlet cat 6. (complete with all lead & lifts complete as per specification and directions of the engineer in charge of the work., 43. supplying and fixing of modular switch & connected accessories on existing modular switch plate as per is 3854 and is 1293. stepped fan regulator. complete with all lead & lifts complete as per specification and directions of the engineer in charge of the work., 44. supplying and fixing of modular switch & connected accessories on existing modular switch plate as per is 3854 and is 1293. tv/tel phone socket. complete with all lead & lifts complete as per specification and directions of the engineer in charge of the work., 45. supplying and fixing of modular switch & connected accessories on existing modular switch plate as per is 3854 and is 1293.6/16amps universal socket. complete with all lead & lifts complete as per specification and directions of the engineer in charge of the work., 46. supplying and fixing regular mcb distribution boards on wall / wood board / flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity mcbs single phase / 3 phase / single door with powder coated painting. made out of 14 swg ms enclosure.ii double door 12 way spn complete with all lead & lifts complete as per specification and directions of the engineer in charge of the work., 47. supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/pvc box. 1 to 3 module complete with all lead & lifts complete as per specification and directions of the engineer in charge of the work., 48. supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/pvc box. 12 module complete with all lead & lifts complete as per specification and directions of the engineer in charge of the work., 49. supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/pvc box. 16 18 module complete with all lead & lifts complete as per specification and directions of the engineer in charge of the work., 50. supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/pvc box. 4 module complete with all lead & lifts complete as per specification and directions of the engineer in charge of the work., 51. supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/pvc box. 6 module complete with all lead & lifts complete as per specification and directions of the engineer in charge of the work., 52. supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/pvc box. 8 module complete with all lead & lifts complete as per specification and directions of the engineer in charge of the work., 53. supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. the box should be firmly flush mounted after due groove cutting in brick/stone/c.c wall 10 12waycomplete with all lead & lifts complete as per specification and directions of the engineer in charge of the work., 54. supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. the box should be firmly flush mounted after due groove cutting in brick/stone/c.c wall 16 18waycomplete with all lead & lifts complete as per specification and directions of the engineer in charge of the work., 55. supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. the box should be firmly flush mounted after due groove cutting in brick/stone/c.c wall 4 5waycomplete with all lead & lifts complete as per specification and directions of the engineer in charge of the work., 56. supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. the box should be firmly flush mounted after due groove cutting in brick/stone/c.c wall 6waycomplete with all lead & lifts complete as per specification and directions of the engineer in charge of the work., 57. supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. the box should be firmly flush mounted after due groove cutting in brick/stone/c.c wall 8waycomplete with all lead & lifts complete as per specification and directions of the engineer in charge of the work., 58. supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. the box should be firmly flush mounted after due groove cutting in brick/stone/c.c wall1 3waycomplete with all lead & lifts complete as per specification and directions of the engineer in charge of the work., 59. supplying and installation of insulated refrigerant copper tubing of 5/8`` and 3/8`` with polythene foam insulation 3 core 80 stand copper wiring between indoor and outdoor unit. leak testing oil and gas charging for additional piping length of tube. split complete with all lead & lifts complete as per specification and directions of the engineer in charge of the work., 60. supplying and running gi/copper conductor for grounding and (along with other wires in conduit system of wiring) using necessary suitable size clamps, nails, guttas/spacers etc. 12 swg. copper wire complete with all lead & lifts complete as per specification and directions of the engineer in charge of the work., 61. supplying and wiring adopting loop system in existing pvc conduit /casing capping casing capping using 2x1.5sqmm (phase & neutral) & 1x1.0 sqmm (earth wire) frls multi strand pvc insulated copper wire (confirming to is 694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/pvc round block. complete for each outlet. long point above 6mtr. upto 10m from tapping point to out let via switch complete with all lead & lifts complete as per specification and directions of the engineer in charge of the work., 62. supplying and wiring adopting loop system in existing pvc conduit /casing capping casing capping using 2x1.5sqmm (phase & neutral) & 1x1.0 sqmm (earth wire) frls multi strand pvc insulated copper wire (confirming to is 694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/pvc round block. complete for each outlet. medium point above 3m. upto 6m from tapping point to out let via switch complete with all lead & lifts complete as per specification and directions of the engineer in charge of the work., 63. supplying and wiring adopting loop system in existing pvc conduit /casing capping casing capping using 2x1.5sqmm (phase & neutral) & 1x1.0 sqmm (earth wire) frls multi strand pvc insulated copper wire (confirming to is 694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/pvc round block. complete for each outlet. short point upto 3mtr from tapping point to out let via switch complete with all lead & lifts complete as per specification and directions of the engineer in charge of the work., 64. supplying and wiring adopting loop system in existing pvc conduit /casing capping casing capping using 2x1.5sqmm (phase & neutral) & 1x1.0 sqmm (earth wire) frls multi strand pvc insulated copper wire (confirming to is 694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/pvc round block. complete for each outlet. three outlet in a row, above 6mtr upto 10mtr from tapping point to out let via switches complete with all lead & lifts complete as per specification and directions of the engineer in charge of the work., 65. supplying and wiring adopting loop system in existing pvc conduit /casing capping casing capping using 2x1.5sqmm (phase & neutral) & 1x1.0 sqmm (earth wire) frls multi strand pvc insulated copper wire (confirming to is 694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/pvc round block. complete for each outlet. two outlet in a row, above 3mtr upto 6mtr from tapping point to out let via switches complete with all lead & lifts complete as per specification and directions of the engineer in charge of the work., 66. supplying fixing of network switches 48 port gigabyte (manageable)complete with all lead & lifts complete as per specification and directions of the engineer in charge of the work., 67. supplying of ......feet pvc batten with integrated led tube.....w with high quality diffuser with life of 25000 burning hours & 70% lumen maintenance with cri > 80. power input: 220 240v @ 50/60hz & power factor >0.9 along with ce approved. 2 years warranty against any manufacturing defect working under standard electrical condition. led light fighting 2x 4 20 /22 w complete with all lead & lifts complete as per specification and directions of the engineer in charge of the work., 68. supplying of .feet pvc batten with integrated led tube.....w with high quality diffuser with life of 25000 burning hours & 70% lumen maintenance with cri > 80. power input: 220 240v @ 50/60hz & power factor >0.9 along with ce approved. 2 years warranty against any manufacturing defect working under standard electrical condition. led light fighting 1 x 2 9/10wcomplete with all lead & lifts complete as per specification and directions of the engineer in charge of the work., 69. supplying of .feet pvc batten with integrated led tube.....w with high quality diffuser with life of 25000 burning hours & 70% lumen maintenance with cri > 80. power input: 220 240v @ 50/60hz & power factor >0.9 along with ce approved. 2 years warranty against any manufacturing defect working under standard electrical condition. led light fighting 1 x 4 20/22wcomplete with all lead & lifts complete as per specification and directions of the engineer in charge of the work., 70. supplying of 2tr invertor type split air conditioners, 71. supplying of ceiling fan with capacitor, 72. supplying of recess mounting non integral type .. led .. w luminaire comprising of pressure decast/extruded aluminium housing, with spring loaded fase ceiling clamps, power leds with cct 6500 degree k, cri> 70%. efficacy >100 lumen per watt, 120degree beam spread, life> 25000 burning hours and compliance to is 10322/iec 60598, lm 79 & lm 80. the lamp compartment is enclosed with anti glare opal diffuser which enhances the lighting level. leds are driven by hf electronic driver integrated in a separate control gear assembly., with pf > 0.95, power loss should < 5% of lamp wattage., short circuit & open circuit protection to be integrated in the circuit, , thd less than 20%, life as per lm 79. the operating input voltage should be between 130 to 275 volts. bis approved and tested by nabl/ cpri accredited laboratory with 2 years warranty against any manufacturing defect working under standard electrical condition led modular down light 2x2 / 1 x 4 42 55 watts complete with all lead & lifts complete as per specification and directions of the engineer in charge of the work., 73. supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes. 1.5 sqmm complete with all lead & lifts complete as per specification and directions of the engineer in charge of the work., 74. supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes. 10sqmm complete with all lead & lifts complete as per specification and directions of the engineer in charge of the work., 75. supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes. 2.5sqmm complete with all lead & lifts complete as per specification and directions of the engineer in charge of the work., 76. supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes. 4sqmm complete with all lead & lifts complete as per specification and directions of the engineer in charge of the work., 77. supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes. 6sqmm complete with all lead & lifts complete as per specification and directions of the engineer in charge of the work., 78. supplying, fixing and wiring residual current circuit breaker (rccb) 240/450v up to 300ma sensitivity on existing wood/panel board 32 amps 2 pole (complete with all lead & lifts complete as per specification and directions of the engineer in charge of the work., 79. video conference equipment, 80. video wall, 81. video wall controller with software, 82. wall mount or ceiling speakers, 83. wifi access point, 84. wiring for lighting/power circuit using one of frls pvc insulated 1100v grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified is 694:confirming to latest amendments. 4 sqmmcomplete with all lead & lifts complete as per specification and directions of the engineer in charge of the work., 85. wiring for lighting/power circuit using one of frls pvc insulated 1100v grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified is 694:confirming to latest amendments. 6 sqmm complete with all lead & lifts complete as per specification and directions of the engineer in charge of the work., 86. wiring for lighting/power circuit using one of frls pvc insulated 1100v grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified is 694:confirming to latest amendments. 1 sqmm complete with all lead & lifts complete as per specification and directions of the engineer in charge of the work., 87. wiring for lighting/power circuit using one of frls pvc insulated 1100v grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified is 694:confirming to latest amendments. 1.5 sqmm complete with all lead & lifts complete as per specification and directions of the engineer in charge of the work., 88. wiring for lighting/power circuit using one of frls pvc insulated 1100v grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified is 694:confirming to latest amendments. 10 sqmm complete with all lead & lifts complete as per specification and directions of the engineer in charge of the work., 89. wiring for lighting/power circuit using one of frls pvc insulated 1100v grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified is 694:confirming to latest amendments. 2.5 sqmm complete with all lead & lifts complete as per specification and directions of the engineer in charge of the work., 90. work station computer, ...

Karnataka State Natural Disaster Monitoring Centre - Karnataka

27768885 supply, installation and maintenance of equipment to strengthen state emergency operations centre and refurbishment at ksdma office, ms building, bangalore 1. 24 u or suitable rack for housing the amplifier & dsp and l3 network switch, 2. confirming to is 8828, on wall / wood board / flush mounting using required clamps, bolts, nuts, etc., with provision for fixing of suitable type capacity mccbs as an incomer for 3 phase double door with necessary bus bar completely wired to use on 440volts 3phase 4 wire powder coated painting etc., complete with a provision for fixing of single / three phase suitable capacity mccb / mcbs as outgoings confirming to is8828. 8way complete with all lead & lifts complete as per specification and directions of the engineer in charge of the work., 3. desktop computer, 4. dismantling the tile work in floor and roof laid in cement or surki mortar including stacking the materials of tiles thickness 10mm to 25mm, 5. extra for fabrication supply and fixing of stand fabricated using slotted angle / l angle of size 6mm x 50mm for mounting out door / indoor a.c. unit. / batteries.complete with all lead & lifts complete as per specification and directions of the engineer in charge of the work., 6. extra for groove cutting in brick wall / cc floor to the suitable depth for concealing of conduit or gi pipe and plastering, finishing upto wall surface complete. upto 50mm conduit in brick wall complete with all lead & lifts complete as per specification and directions of the engineer in charge of the work., 7. extra length of gi pipe of class b 19mm dia for down rod.. complete with all lead & lifts complete as per specification and directions of the engineer in charge of the work., 8. fixing a ceiling / wall mounting fan of all capacities and all types, with necessary clamps and s hook made out of 15mm dia ms rod, with 5 amps. ceiling rose of approved quality with necessary length of 23 / 0.0076 inch pvc insulated twin twisted wire of approved quality, mounted on a suitable size wooden board and wired.complete with all lead & lifts complete as per specification and directions of the engineer in charge of the work., 9. fixing all types and all capacities of fluorescent / false ceiling / spot light / cfl / led fittings indoor on the wall / ceiling / rafters / girders using 23 / 0.0076 inch twin twisted pvc insulatedwires, required nos of round blocks and clamps.complete with all lead & lifts complete as per specification and directions of the engineer in charge of the work., 10. fixing one exhaust fan in the nitch already left in the wall with bolts and nuts and 5 amps. ceiling rose with sufficient length of 23 / 0.0076 inch pvc insulated twin core wire. complete with all lead & lifts complete as per specification and directions of the engineer in charge of the work., 11. gooseneck mic, 12. groove cutting in walls supplying heavy gauge pvc conduit pipe with suitable size bends, metal junction boxes adhesive paste etc., by groove cutting in the wall and fixing by bracing u or j hooks and cement plastering up to the wall surface and run with 18 swg gi fish wire run throughout the conduit wherever necessary. complete with all lead & lifts complete as per specification and directions of the engineer in charge of the work. 19 or 20mm dia 2mm thick, 13. groove cutting in walls supplying heavy gauge pvc conduit pipe with suitable size bends, metal junction boxes adhesive paste etc., by groove cutting in the wall and fixing by bracing u or j hooks and cement plastering up to the wall surface and run with 18 swg gi fish wire run throughout the conduit wherever necessary. complete with all lead & lifts complete as per specification and directions of the engineer in charge of the work. 25mm dia 2mm thick, 14. groove cutting in walls supplying heavy gauge pvc conduit pipe with suitable size bends, metal junction boxes adhesive paste etc., by groove cutting in the wall and fixing by bracing u or j hooks and cement plastering up to the wall surface and run with 18 swg gi fish wire run throughout the conduit wherever necessary. complete with all lead & lifts complete as per specification and directions of the engineer in charge of the work. 32mm dia 2.5mm thick, 15. installation charges for 2ton split type air conditioner, 16. open conduit system supplying heavy gauge pvc conduit pipe confirming to is 2509 with suitable size bends, junction boxes, adhesive paste etc. and fixing using inverted wood plugs in case of rcc ceiling and rcc wall or stone structure or rawl plugs in case of brick walls and cement plastering the damaged portion using heavy gauge saddles at an interval of 700mm using nf screws. complete with all lead & lifts complete as per specification and directions of the engineer in charge of the work. 19 or 20mm dia 2mm thick., 17. open conduit system supplying heavy gauge pvc conduit pipe confirming to is 2509 with suitable size bends, junction boxes, adhesive paste etc. and fixing using inverted wood plugs in case of rcc ceiling and rcc wall or stone structure or rawl plugs in case of brick walls and cement plastering the damaged portion using heavy gauge saddles at an interval of 700mm using nf screws. complete with all lead & lifts complete as per specification and directions of the engineer in charge of the work. 25mm dia 2mm thick., 18. open conduit system supplying heavy gauge pvc conduit pipe confirming to is 2509 with suitable size bends, junction boxes, adhesive paste etc., and fixing using inverted wood plugs in case of rcc ceiling and rcc wall or stone structure or rawl plugs in case of brick walls and cement plastering the damaged portion using heavy gauge saddles at an interval of 700mm using nf screws. complete with all lead & lifts complete as per specification and directions of the engineer in charge of the work. 32 mm dia 2.5mm thick., 19. power amplifier with integrated or external digital signal processor, 20. providing & fixing factory made pvc door frame of size 50x47mm with a wall thickness of 5mm, made out of extruded 5mm rigid pvc foam sheet metered cut at corners & jointed 2 no.s of 150mm long brackets of 15x15mm m.s square tube, the entire door frame to be reinforced with 19x19mm m.s square tube of 19 gauge. the door frame to be fixed to the wall using m.s. screws of 65 / 80mm size complete with all lead & lifts complete as per specification and directions of the engineer in charge of the work., 21. providing and fixing stainless steel kitchen sink of size 400x915mm bowl depth 160mm, with drain board, m.s / c.i brackets, stainless steel plug 40 mm, painting of fittings and brackets, cutting and making good the wall and floor wherever required, including cost of materials, labour complete with all lead & lifts complete as per specification and directions of the engineer in charge of the work., 22. providing and laying of modular wooden polished flooring of 12mm thick, high density timber of approved colour and design with end trims, transition, profiles, beading, 15mm thick felt, and 20 micron polyester film with 4mm thick foam underlay etc., including cost of all materials, mortar, labour, curing etc., complete with all lead & lifts complete as per specification and directions of the engineer in charge of the work., 23. providing and applying painting in two coats with plastic emulsion paint of approved brand on wall surface with one coat of primer to give an even approved shade after throughly brushing the surface, free from mortar drops and other foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour, complete with all lead & lifts complete as per specification and directions of the engineer in charge of the work, 24. providing and applying painting in two coats with plastic emulsion paint of approved brand on wall surface with one coat of primer to give an even approved shade after throughly brushing the surface, free from mortar drops and other foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour, complete with all lead & lifts complete as per specification and directions of the engineer in charge of the work., 25. providing & fixing of mineral fibre acoustical suspended ceiling system in module size of 600 x 600 x 16mm with exposed grid. tiles having humidity resistance ( rh ) of 99%, nrc 0.5, light reflectance ;, 83%, thermal conductivity k = 0.052 0.057 w / m k, colour white, fire performance uk class 0 i class 1 ( bs 476 pt 6 &7 ) with sand texture finished dune and suitable for green building application with recycled content of 39%. the tile shall be laid on 24 mm wide t section flanges colour white having rotary stitching on all t sections i.e. the main runner, 1200 mm & 600 mm cross tees with a web height of 38mm and a load carrying capacity of 15kgs / sqm&pull out strength of minimum 100 kgs. the t sections should have a galvanizing of 90 grams per sqm and need to be installed with suspension system of approved make, 26. providing & fixing 30mm thick factory made rigid foam both side prelam panelled door shutters made from m.s. tube of 19x19mm, 19 gauge for styles and 15x15mm for top & bottom rails, covered with heat moulded prelaminated pvc c channel of 5mm thick sheet & 30x50mm wide to form styles & 5mm thick & 75mm wide prelaminated pvc sheets for top rail, lock rail & bottom rail on either side & 5mm thick, 20mm wide cross pvc sheet as gap insert for top rail & bottom rail, panelling of 5mm thick pvc sheet prelaminated on either side fitted in the m.s. frame, complete with all lead & lifts complete as per specification and directions of the engineer in charge of the work., 27. providing 12mm thick cement plaster in single coat with cement mortar 1: 3 to flooring including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete with all lead & lifts complete as per specification and directions of the engineer in charge of the work, 28. providing ceramic tiles of approved make, shade and size for flooring, treads of steps and landings laid on a bed of 12mm thick, cement mortar 1 :3 mix, flush pointing with white , cement using colour pigment, including cost of materials, labour, curing, complete with all lead & lifts complete as per specification and directions of the engineer in charge of the work. 30x30x6mm thick, 29. providing and applying enamel metal paint two coats ( excluding priming coat ) over new steel or other metal surface brushing to give an even shade after cleaning oil, grease, dirt and other foreign matter, including cost of materials, labour, complete with all lead & lifts complete as per specification and directions of the engineer in charge of the work, 30. providing and applying painting two coats ( excluding priming coat ) on new wood surface and / or wood based surface with enamel paint to give an even shade, cleaning the surface of all dirt, dust and foreign matter, sand papering including cost of materials, labour, complete with all lead & lifts complete as per specification and directions of the engineer in charge of the work, 31. providing and fixing ci nahani trap of approved quality and make confirming to is specifications and construction of cistern in cc 1:2:4 including cost of materials, conveyance, labour complete with all lead & lifts complete as per specification and directions of the engineer in charge of the work, 32. providing and fixing stoneware gully trap of approved quality and fixing in cc 1:2:4 including cost of materials, conveyance, labour complete with all lead & lifts complete as per specification and directions of the engineer in charge of the work, 33. providing and fixing 1500x450mm dia rectangular shape mirror with plastic moulded frame of approved make and shade with 6mm thick hard board backing including cost of materials, labour complete with all lead & lifts complete as per specification and directions of the engineer in charge of the work, 34. providing and fixing 2 way bib cock hindware or equivalent make including cost of materials, conveyance, labour complete with all lead & lifts complete as per specification and directions of the engineer in charge of the work, 35. providing and fixing angular stop cock hindware or equivalant make including cost of materials, conveyance, labour complete with all lead & lifts complete as per specification and directions of the engineer in charge of the work, 36. providing and fixing bottle trap 32 mm with 300 mm & 175 mm long wall connection pipe & wall flange ( premium ) hindware or equivalant make including cost of materials, conveyance, labour complete with all lead & lifts complete as per specification and directions of the engineer in charge of the work, 37. providing and fixing c.p. brass towel rail 900 mm length, 20mm dia with c.p brackets, fixed to wooden cleats with c.p. brass screws including cost of materials, labour complete with all lead & lifts complete as per specification and directions of the engineer in charge of the work, 38. providing and fixing chorinated poly venyl chloride ( cpvc ) pipes conforming to is 15778, having thermal stability for hot and cold water supply including cpvc plain and brass threaded fittings including fixing the pipe with clamp at 1.00mtr spacing. this includes jointing of pipes and fittings with one step cpvc solvent cement and the cost of cutting chases and making good the same including testing of joints complete with all lead & lifts complete as per specification and directions of the engineer in charge of the work, 39. providing and fixing chorinated poly venyl chloride ( cpvc ) pipes conforming to is 15778, having thermal stability for hot and cold water supply including cpvc plain and brass threaded fittings including fixing the pipe with clamp at 1.00mtr spacing. this includes jointing of pipes and fittings with one step cpvc solvent cement and the cost of cutting chases and making good the same including testing of joints complete with all lead & lifts complete as per specification and directions of the engineer in charge of the work., 40. providing and fixing health faucet ( brass ) with double lock 1m brass plated flexible hose & wall hook hindwareor equivalant make including cost of materials, conveyance, labour complete with all lead & lifts complete as per specification and directions of the engineer in charge of the work., 41. providing and fixing pillar cock hindware or equivalent make including cost of materials, conveyance, labour complete with all lead & lifts complete as per specification and directions of the engineer in charge of the work, 42. providing and fixing special make glazed vitrified tiles ( granomite finish ) of approved make, quality and colour of size 600x600x10mm thick fixed on existing flooring with a special adhesive for flooring, skirting and jointed with neat cement slurry mixed with pigment to match shade of tiles, including providing spacers at required interval and removing stains etc., cost of materials, mortar, labour etc., complete with all lead & lifts complete as per specification and directions of the engineer in charge of the work, 43. providing and fixing veneer paneling, over the 50mm x 35mm sal wood frame work at spacing not exceeding 60dmm c / c fixed to the wall and top covered out of 4mm thick approved quality veneer, fixed over 12mm thick ply of approved brand, termite and water resistant, finished with melamine polish, complete including cost and conveyance of all materials, labour for all items of work hom etc., complete with all lead & lifts complete as per specification and directions of the engineer in charge of the work., 44. providing and fixing factory made single leaft rigid grp sandwich composite door shutter of 32mm thick, laminated with two grp skins with wood grain finish, fabricated using u.v stabilized isopthalic gelcoat and on layer of 45 gsm e glass chopped strand mat ( csm ) , impregnated with orthopthalic polyster resin. the thickness of the skins shall not be less than 1.5mm. expanded polystyrene ( eps ) structural foam panel of 29mm thickness and a density of 20 kg / m3 shall be used as core material. wooden reinforcements made of seasoned salwood block of cross section not less than 28mmx32mm and also necessary salwood reinforcements for fixing the metal fittings such as tower bolts, aldrops, handles, etc, shall be provided. a structural adhesive compatible with eps foam shall be used for bonding the core material, the salwood reinforcement and the skins. the material and process for manufacturing the door shutters shall confirm to rv / tifac composites design centre standards and specifications and the door shutters tested in confiramation to is 4020 1994. the finish of shutter will be plain colour white / ivory / beige / light grey or any other colour using high quality pigments. exclusing cost of fixtures and inclusive of supply of shutters to respective work spot.complete with all lead & lifts complete as per specification and directions of the engineer in charge of the work., 45. providing and fixing modular partition consisting of 75mm thick frames tile based system ( frame with tile ) 75mm thick ms crca frames powder coated, tile based system frame, 8mm thick mdf covered with fabric of approved colour for top file finish, 5mm thick clear ordinary glass both side middle tile finish, or 8mm thick mdf covered with fabric of approved colour for middle tile finish, 9mm thick laminate tile of approved colour for botom tile finish, continuous skirting level raceway will be provided. complete with all lead & lifts complete as per specification and directions of the engineer in charge of the work., 46. providing and fixing to wall, ceiling and floor unplasticised pvc 6.00 kgs / sqcm working pressure with pipe fittings, wall clips etc., and making good the wall, ceiling and floor for sanitary pipelines including cost of all materials, labour charges, hom of acquirements and testing complete with all lead & lifts complete as per specification and directions of the engineer in charge of the work. 110mm dia, 47. providing and fixing white vitreous china clay, table top wash basin size : 49 x 40 x 15 cm hindware make cutting and making good the wall and floor wherever required, including cost of materials, labour complete with all lead & lifts complete as per specification and directions of the engineer in charge of the work, 48. providing and fixing white vitreous china clay, water closet size : 62.5 x 36 x 76 cm cistern with lid complete set hindware or equivalant make cutting and making good the wall and floor wherever required, including cost of materials, labour complete with all lead & lifts complete as per specification and directions of the engineer in charge of the work., 49. providing and fixing white vitreous china clay, flat back, lipped front urinal basin of 430x260x350mm in the range of three 7.5 litres pvc automatic flushing cistern, c.i / m.s brackets, standard flush pipe and c.p. brass spreaders with brass unions and g.i. clamps painting of fittings and brackets, cutting and making good the wall and floor wherever required, including cost of materials, labour complete with all lead & lifts complete as per specification and directions of the engineer in charge of the work, 50. providing and laying platform using prepolished, water cut / gang saw 40mm thick telephonic black granite. laid on existing vertical supports and fixing in cm 1:3 proportion. including cutting to required shape, pattern with paper joints, including full rounding for nosing, finished with cement mortar, pointed with colour pigments to match the colour of slab making through jointing with sealant, making holes 25mm x 12mm grooves in joints including cost of all materials, mortar, labour, curing etc., complete with all lead & lifts complete as per specification and directions of the engineer in charge of the work., 51. providing rough cement plastering 15mm thick in single coat with cement mortar 1:4, 52. providing skirting, dado, rises of steps with colour glazed tiles on 10mm thick cement plaster 1:3 and jointed with white cement slurry over rough plaster surface ( excluding cost of rough plastered surface which should be measured and paid separately ) using glazed tiles of approved make and size including cost of materials, labour, complete as per specifications. specification no.kbs 14.16, 14.17 colour glazed tiles 30x45 cms 6mm thick with border of size 30 x 10 cms.complete with all lead & lifts complete as per specification and directions of the engineer in charge of the work, 53. removing of existing old or broken wash basin / urinals and disposing it, 54. supply of round / square recess / surface mounted rolling type led down light with .......w gu 10 led lamp rib fabricated from die cast aluminium with white powder coated prewired to mains connector & has swiveling unit of aluminium die cast eye ball & led lamp position retained by circular wire spring, with life of 25000 burning hours & 70% lumen maintenance with cri > 80. power input: 220 240v @ 50 / 60hz & power factor >0.9 along with ce approved. 2 years warranty against any manufacturing defect working under standard electrical condition led square or round down light 15 18w complete with all lead & lifts complete as per specification and directions of the engineer in charge of the work., 55. supplying & fixing of switch mounting rack with power manager & cable manager. supplying & fixing of fan complete with all lead & lifts complete as per specification and directions of the engineer in charge of the work., 56. supplying & fixing of switch mounting rack with power manager & cable manager. supplying & fixing of power strip complete with all lead & lifts complete as per specification and directions of the engineer in charge of the work., 57. supplying & fixing of switch mounting rack with power manager & cable manager. supplying fixing of network switches 24 port gigabyte ( manageable ) complete with all lead & lifts complete as per specification and directions of the engineer in charge of the work., 58. supplying & fixing of switch mounting rack with power manager & cable manager. 9u with 450mm depth complete with all lead & lifts complete as per specification and directions of the engineer in charge of the work., 59. supplying & fixing flexible led strip light power consumption in 5mtrs length cct 6500 degree k, cri> 70%. efficacy >80 lumen per watt, life> 25000 burning hours and compliance to is 10322 / iec 60598, lm 79 & lm 80. the led are driven by hf electronic driver non integrated, with pf > 0.95, power loss should < 5% of lamp wattage., short circuit & open circuit protection to be integrated in the circuit, thd less than 20%, life as per lm 79. the operating input voltage should be between 130 to 275 volts. bis approved with 2 years warranty against any manufacturing defect working under standard electrical condition.complete with all lead & lifts complete as per specification and directions of the engineer in charge of the work., 60. supplying & fixing cat6 patch cable 1 mtr complete with all lead & lifts complete as per specification and directions of the engineer in charge of the work., 61. supplying & fixing cat6 patch cable 2 mtr complete with all lead & lifts complete as per specification and directions of the engineer in charge of the work., 62. supplying & fixing of patch panel for lan cabling 24 port 10 / 100 patch panel complete with all lead & lifts complete as per specification and directions of the engineer in charge of the work., 63. supplying pvc or gi flexible conduit pipe fixing on surface over inverted tapered wooden plugs or phill plugs or rawl plugs and clamped using heavy gauge saddles at an interval of 300mm using nf screws and on either end of the pipe terminated completely 25mm complete with all lead & lifts complete as per specification and directions of the engineer in charge of the work., 64. supplying pvc or gi flexible conduit pipe fixing on surface over inverted tapered wooden plugs or phill plugs or rawl plugs and clamped using heavy gauge saddles at an interval of 300mm using nf screws and on either end of thepi pe terminated completely 32mm complete with all lead & lifts complete as per specification and directions of the engineer in charge of the work., 65. supplying and drawing pvc flexible one pair telephone unarmoured tinned copper cable. complete with all lead & lifts complete as per specification and directions of the engineer in charge of the work., 66. supplying and drawing pvc flexible one pair telephone unarmoured tinned copper cable.complete with all lead & lifts complete as per specification and directions of the engineer in charge of the work., 67. supplying and drawing pvc insulated gas injected physical foam jelly flooded co axial tv cable.rg 6. complete with all lead & lifts complete as per specification and directions of the engineer in charge of the work., 68. supplying and fixing miniature circuit breakers on existing mcb distribution boards using necessary fixing materials and c type curve, indicator on / off, energy cross 3 with short circuit breaking capacity of 10k and complete wiring as required confirming to iec 60898. 5 32 amps dp., 69. supplying and fixing miniature circuit breakers on existing mcb distribution boards using necessary fixing materials and c type curve, indicator on / off, energy cross 3 with short circuit breaking capacity of 10k and complete wiring as required confirming to iec 60898. 50 63 amps tpn., 70. supplying and fixing miniature circuit breakers on existing mcb distribution boards using necessary fixing materials and c type curve, indicator on / off, energy cross 3 with short circuit breaking capacity of 10k and complete wiring as required confirming to iec 60898. 6 32 amps sp. complete with all lead & lifts complete as per specification and directions of the engineer in charge of the work., 71. supplying and fixing miniature circuit breakers on existing mcb distribution boards using necessary fixing materials and c type curve, indicator on / off, energy cross 3 with short circuit breaking capacity of 10k and complete wiring as required confirming to iec 60898. 6 32amps tpn, 72. supplying and fixing of mdf krone junction box with krone module / telephone cable termination. 50pair complete with all lead & lifts complete as per specification and directions of the engineer in charge of the work., 73. supplying and fixing of pvc casing and capping on the wall or ceiling using necessary materials like bends, screws at an interval of 300mm etc. as required.50 mm complete with all lead & lifts complete as per specification and directions of the engineer in charge of the work., 74. supplying and fixing of modular switch & connected accessories on existing modular switch plate as per is 3854 and is 1293. 16amps one way switch, 75. supplying and fixing of modular switch & connected accessories on existing modular switch plate as per is 3854 and is 1293. 32amps dp switch ( complete with all lead & lifts complete as per specification and directions of the engineer in charge of the work., 76. supplying and fixing of modular switch & connected accessories on existing modular switch plate as per is 3854 and is 1293. 6 / 16amps universal socket. complete with all lead & lifts complete as per specification and directions of the engineer in charge of the work., 77. supplying and fixing of modular switch & connected accessories on existing modular switch plate as per is 3854 and is 1293. 6amps 3way socket. complete with all lead & lifts complete as per specification and directions of the engineer in charge of the work., 78. supplying and fixing of modular switch & connected accessories on existing modular switch plate as per is 3854 and is 1293. 6amps one way. complete with all lead & lifts complete as per specification and directions of the engineer in charge of the work., 79. supplying and fixing of modular switch & connected accessories on existing modular switch plate as per is 3854 and is 1293. rj45 / i.o.outlet cat 6. complete with all lead & lifts complete as per specification and directions of the engineer in charge of the work., 80. supplying and fixing of modular switch & connected accessories on existing modular switch plate as per is 3854 and is 1293. stepped fan regulator complete with all lead & lifts complete as per specification and directions of the engineer in charge of the work., 81. supplying and fixing of modular switch & connected accessories on existing modular switch plate as per is 3854 and is 1293. tv / tel phone socket. complete with all lead & lifts complete as per specification and directions of the engineer in charge of the work., 82. supplying and fixing regular mcb distribution boards on wall / wood board / flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity mcbs single phase / 3 phase / single door with powder coated painting. made out of 14 swg ms enclosure.ii double door 12 way spn, 83. supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal / pvc box. 1 to 3 module complete with all lead & lifts complete as per specification and directions of the engineer in charge of the work., 84. supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal / pvc box. 12 module complete with all lead & lifts complete as per specification and directions of the engineer in charge of the work., 85. supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal / pvc box. 16 18 module complete with all lead & lifts complete as per specification and directions of the engineer in charge of the work., 86. supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal / pvc box. 4 module complete with all lead & lifts complete as per specification and directions of the engineer in charge of the work., 87. supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal / pvc box. 6 module complete with all lead & lifts complete as per specification and directions of the engineer in charge of the work., 88. supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal / pvc box. 8 module complete with all lead & lifts complete as per specification and directions of the engineer in charge of the work., 89. supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. the box should be firmly flush mounted after due groove cutting in brick / stone / c.c wall 1 3way complete with all lead & lifts complete as per specification and directions of the engineer in charge of the work., 90. supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. the box should be firmly flush mounted after due groove cutting in brick / stone / c.c wall 10 12way complete with all lead & lifts complete as per specification and directions of the engineer in charge of the work., 91. supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. the box should be firmly flush mounted after due groove cutting in brick / stone / c.c wall 16 18way complete with all lead & lifts complete as per specification and directions of the engineer in charge of the work., 92. supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. the box should be firmly flush mounted after due groove cutting in brick / stone / c.c wall 4 5way complete with all lead & lifts complete as per specification and directions of the engineer in charge of the work., 93. supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. the box should be firmly flush mounted after due groove cutting in brick / stone / c.c wall 6way complete with all lead & lifts complete as per specification and directions of the engineer in charge of the work., 94. supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. the box should be firmly flush mounted after due groove cutting in brick / stone / c.c wall 8way complete with all lead & lifts complete as per specification and directions of the engineer in charge of the work., 95. supplying and installation of insulated refrigerant copper tubing of 5 / 8`` and 3 / 8`` with polythene foam insulation 3 core 80 stand copper wiring between indoor and outdoor unit. leak testing oil and gas charging for additional piping length of tube..split complete with all lead & lifts complete as per specification and directions of the engineer in charge of the work., 96. supplying and running gi / copper conductor for grounding and ( along with other wires in conduit system of wiring ) using necessary suitable size clamps, nails, guttas / spacers etc. 12 swg. copper wire, 97. supplying and wiring adopting loop system in existing pvc conduit or casing capping casing capping using 2x1.5sqmm ( phase & neutral ) & 1x1.0 sqmm ( earth wire ) frls multi strand pvc insulated copper wire ( confirming to is 694: and latest amendments ) without control switch shall be fixed on the existing plastic sheet or gang box, the other end of the wires shall be terminated with sufficient loose length in a wood or pvc round block. complete for each outlet. complete with all lead & lifts complete as per specification and directions of the engineer in charge of the work. three outlet in a row, above 6mtr upto 10mtr from tapping point to out let via switches, 98. supplying and wiring adopting loop system in existing pvc conduit or casing capping casing capping using 2x1.5sqmm ( phase & neutral ) & 1x1.0 sqmm ( earth wire ) frls multi strand pvc insulated copper wire ( confirming to is 694: and latest amendments ) without control switch shall be fixed on the existing plastic sheet or gang box, the other end of the wires shall be terminated with sufficient loose length in a wood or pvc round block. complete for each outlet. complete with all lead & lifts complete as per specification and directions of the engineer in charge of the work. long point above 6mtr. upto 10m from tapping point to out let via switch, 99. supplying and wiring adopting loop system in existing pvc conduit or casing capping casing capping using 2x1.5sqmm ( phase & neutral ) & 1x1.0 sqmm ( earth wire ) frls multi strand pvc insulated copper wire ( confirming to is 694: and latest amendments ) without control switch shall be fixed on the existing plastic sheet or gang box, the other end of the wires shall be terminated with sufficient loose length in a wood or pvc round block. complete for each outlet. complete with all lead & lifts complete as per specification and directions of the engineer in charge of the work. medium point above 3m. upto 6m from tapping point to out let via switch, 100. supplying and wiring adopting loop system in existing pvc conduit or casing capping casing capping using 2x1.5sqmm ( phase & neutral ) & 1x1.0 sqmm ( earth wire ) frls multi strand pvc insulated copper wire ( confirming to is 694: and latest amendments ) without control switch shall be fixed on the existing plastic sheet or gang box, the other end of the wires shall be terminated with sufficient loose length in a wood or pvc round block. complete for each outlet. complete with all lead & lifts complete as per specification and directions of the engineer in charge of the work. short point upto 3mtr from tapping point to out let via switch, 101. supplying and wiring adopting loop system in existing pvc conduit or casing capping casing capping using 2x1.5sqmm ( phase & neutral ) & 1x1.0 sqmm ( earth wire ) frls multi strand pvc insulated copper wire ( confirming to is 694: and latest amendments ) without control switch shall be fixed on the existing plastic sheet or gang box, the other end of the wires shall be terminated with sufficient loose length in a wood or pvc round block. complete for each outlet. complete with all lead & lifts complete as per specification and directions of the engineer in charge of the work. two outlet in a row, above 3mtr upto 6mtr from tapping point to out let via switches., 102. supplying of 1440rpm heavy duty exhaust fan with bracket blades suitable to operate on 230v 50hz, ac supply complete.15 sweep complete with all lead & lifts complete as per specification and directions of the engineer in charge of the work., 103. supplying of 2tr invertor type split air conditioners, 104. supplying of ceiling fan with capacitor rating as per guideline of bee 5 star rating and is:374 / 79 and also comply with is:1709 / 1984, 105. supplying of pvc batten with integrated led tube.....w with high quality diffuser with life of 25000 burning hours & 70% lumen maintenance with cri > 80. power input: 220 240v @ 50 / 60hz & power factor >0.9 along with ce approved. 2 years warranty against any manufacturing defect working under standard electrical condition. led light fighting 1 x 2 9 / 10w complete with all lead & lifts complete as per specification and directions of the engineer in charge of the work., 106. supplying of pvc batten with integrated led tube.....w with high quality diffuser with life of 25000 burning hours & 70% lumen maintenance with cri > 80. power input: 220 240v @ 50 / 60hz & power factor >0.9 along with ce approved. 2 years warranty against any manufacturing defect working under standard electrical condition. led light fighting 1 x 4 20 / 22w complete with all lead & lifts complete as per specification and directions of the engineer in charge of the work., 107. supplying of pvc batten with integrated led tube.....w with high quality diffuser with life of 25000 burning hours & 70% lumen maintenance with cri > 80. power input: 220 240v @ 50 / 60hz & power factor >0.9 along with ce approved. 2 years warranty against any manufacturing defect working under standard electrical condition. led light fighting 2x 4 20 / 22 w complete with all lead & lifts complete as per specification and directions of the engineer in charge of the work., 108. supplying of recess mounting non integral type ........led ...... w luminaire comprising of pressure decast / extruded aluminium housing, with spring loaded fase ceiling clamps, power leds with cct 6500 degree k, cri> 70%. efficacy >100 lumen per watt, 120degree beam spread, life> 25000 burning hours and compliance to is 10322 / iec 60598, lm 79 & lm 80. the lamp compartment is enclosed with anti glare opal diffuser which enhances the lighting level. leds are driven by hf electronic driver integrated in a separate control gear assembly., with pf > 0.95, power loss should < 5% of lamp wattage., short circuit & open circuit protection to be integrated in the circuit, , thd less than 20%, life as per lm 79. the operating input voltage should be between 130 to 275 volts. bis approved and tested by nabl / cpri accredited laboratory with 2 years warranty against any manufacturing defect working under standard electrical condition led modular down light 2x2 / 1 x 4 42 55 watts complete with all lead & lifts complete as per specification and directions of the engineer in charge of the work., 109. supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes. 1.5 sqmm complete with all lead & lifts complete as per specification and directions of the engineer in charge of the work., 110. supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes. 10sqmm complete with all lead & lifts complete as per specification and directions of the engineer in charge of the work., 111. supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes. 2.5sqmm complete with all lead & lifts complete as per specification and directions of the engineer in charge of the work., 112. supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes. 4sqmm complete with all lead & lifts complete as per specification and directions of the engineer in charge of the work, 113. supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes. 6sqmm complete with all lead & lifts complete as per specification and directions of the engineer in charge of the work., 114. supplying, erecting, testing & commissioning of on line ups system suitable for operation on 230v, 50hz, a / c supply, with isolation transformer all accessories complete and excluding batteries and wiring complete. 5 kva on line ups complete with all lead & lifts complete as per specification and directions of the engineer in charge of the work., 115. supplying, fixing and wiring residual current circuit breaker ( rccb ) 240 / 450v up to 300ma sensitivity on existing wood / panel board 32 amps 2 pole, 116. supplying, installation, testing & commissioning of 12v dc, ah batteries in poly propylene container for u.p.s. sealed maintenance free batteries. 120 ah capacity complete with all lead & lifts complete as per specification and directions of the engineer in charge of the work., 117. video conference equipment, 118. video wall controller with software, 119. video wall display unit, 120. wall mount or ceiling speakers, 121. wiring for lighting or power circuit using one of frls pvc insulated 1100v grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified is 694:confirming to latest amendments complete with all lead & lifts complete as per specification and directions of the engineer in charge of the work. 6 sqmm, 122. wiring for lighting or power circuit using one of frls pvc insulated 1100v grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified is 694:confirming to latest amendments. complete with all lead & lifts complete as per specification and directions of the engineer in charge of the work. 1.5 sqmm, 123. wiring for lighting or power circuit using one of frls pvc insulated 1100v grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified is 694:confirming to latest amendments. complete with all lead & lifts complete as per specification and directions of the engineer in charge of the work. 2.5 sqmm, 124. wiring for lighting or power circuit using one of frls pvc insulated 1100v grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified is 694:confirming to latest amendments. complete with all lead & lifts complete as per specification and directions of the engineer in charge of the work. 1 sqmm, 125. wiring for lighting or power circuit using one of frls pvc insulated 1100v grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified is 694:confirming to latest amendments complete with all lead & lifts complete as per specification and directions of the engineer in charge of the work. 4 sqmm, 126. wiring for lighting or power circuit using one of frls pvc insulated 1100v grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified is 694:confirming to latest amendments complete with all lead & lifts complete as per specification and directions of the engineer in charge of the work. 10 sqmm, 127. workstation computer, ...

Karnataka Power Transmission Corporation Limited - Karnataka

27754837 site survey, planning, testing, design, engineering, supply, erection and commissioning of 48 fiber opgw cable by replacing existing earth wire in 220kv & 400kv transmission lines under buy back in karnataka state (kptcl) on total turnkey basis including supply of all matching materials/equipments and erection of all materials/ equipments, testing and commissioning, conforming to kptcl specifications ...

Karnataka Power Transmission Corporation Limited - Karnataka

26814935 site survey, planning, testing, design, engineering, supply, erection and commissioning of opgw cable by replacing existing earth wire in 220kv and 400kv transmission lines under buy back in karnataka state ( kptcl ) on total turnkey basis including supply of all matching materials / equipments and erection of all materials / equipments, testing and commissioning, conforming to kptcl specifications for implementation of reliable communication for 220 kv, 400 kv substations and generating stations for voice, data ( scada amd pmu ) and protection in karnataka state ( kptcl ) ....

Military Engineer Services - Karnataka

26763823 repairs and replacement of unserviceable light fitting and internal wiring at residential and otm accn at dhq 3 new mangalore under ge ( i ) ( cg ) goa , taking down carefully unserviceable/burnt copper/aluminium point wiring ( light , fan , socket or power ) complete , ( fittings such as switches , ceiling roses , pendants , regulators , socket etc to be measured separately ) , and keeping aside for taking in account of credit and making good disturbed surfaces of walls , floors etc complete all as specified and directed . , m&l point wiring complete with 1 . 5 sqmm single core pvc insulted fr cable 1100 volts grade with multistranded copper conductor drawn through and including 20mm dia pvc rigid non metallic pvc conduit with all accessories such as internal bend , end caps , etc complete fixed on walls/ceiling/roof/etc by means of suitable gi saddles/spacers and including provision of 1 . 5 sqmm single core pvc insulated fr cable 1100 volts grade with multistranded copper conductor cable as earth continuity conductor , fabricated steel terminal box made out of 1 . 6 mm thick ms sheet concealed in walls with 3mm thick bakelite top cover sheet , isi maked with chromium plated screws and cup washers for housing the switches , socket outlets , fan regulators etc , complete all as specified and directed for the following : , one light point controlled by one , one way switch . , one fan point controlled by one , one way switch and regulator . , one switch socket outlet point controlled by one 06 amp switch on independent board . , one switch socket outlet point controlled by one 06 amp switch on same board . , one light point controlled by two way 2 switches 06 amps . , one call bell/buzzer point controlled by one bell push switch . , all as per item no . 2 . 00 described here in before but with copper conductor cable fr 2 . 5 sqmm for one 3 pin socket outlet , 16 amps and including provision of fr 2 . 5 sqmm pvc insulated copper conductor cable as earth continuity conductor on independent board complete all as specified and directed . , m&l for point wiring complete with 1 . 5 sqmm single core pvc insulted fr cable 1100 volts grade with multistranded copper conductor drawn through in existing conduit including 1 . 5 sqmm single core pvc insulated fr cable 1100 volts grade with multistranded copper conductor cable as earth continuity conductor , complete all as specified and directed for the following : , one light point controlled by one , one way switch . , one fan point controlled by one , one way switch and regulator . , one switch socket outlet point controlled by one 06 amp switch on independent board . , one switch socket outlet point controlled by one 06 amp switch on same board . , one light point controlled by two way 2 switches 06 amps . , one call bell/buzzer point controlled by one bell push switch . , all as per item no . 4 . 00 described here in before but with copper conductor cable fr 2 . 5 sqmm for one 3 pin socket outlet , 16 amps and including of fr 2 . 5 sqmm pvc insulated copper conductor cable as earth continuity conductor on independent board complete all as specified and directed . , supply and fix in repairs holder pvc bakelite angular /pendant with back plate complete all as specified and directed . , supply and fix in repairs switch piano flush button single pole one way 06 a complete all as specified and directed . , supply and fix in repairs switch piano flush button single pole one way 16 a complete all as specified and directed . , supply and fix in repairs switch socket combination 16 amps flush type universal complete all as specified and directed . , supply and fix in repairs switch socket combination 06 amps flush type complete all as specified and directed . , supply and fix in repairs socket outlet , 5 pin 06 amps flush type complete all as specified and directed . , supply and fix in repairs socket outlet , multi purpose two in one , 06 & 16 amps flush type complete all as specified and directed . , supply and fix in repairs switch piano flush button two way 06 a complete all as specified and directed . , supply and fix in repairs step type ( five ) fan regulator , 230 volts ac complete all as specified and directed . , supply and fix in repairs bell push flush type 06 a complete all as specified and directed . , supply and fix in repair call bell , ding dong , electric ac 230volt complete all as specified and directed . , supply and fix in repairs ceiling rose surface type bakelite 65 x 50mm with three terminals complete all as specified and directed . , supply and fix in repairs modular switch 6a single pole , one way , 1 module , complete all as specified and directed . make: anchor roma cat no . 21011 , cona trump cat no . 15001 or similar make as mentioned in ps . , supply and fix in repairs modular switch 16a , one way , 1 module complete all as specified and directed . make: anchor roma cat no . 21066 , cona trump cat no . 15051 or similar make as mentioned in ps . , supply and fix in repairs modular socket , 06a , 2 in 1 , 2 module complete all as specified and directed . make: anchor roma cat no . 30373 , cona trump cat no . 15091 or similar make as mentioned in ps . , supply and fix in repairs modular socket 06/16a , heavy duty 2 module complete all as specified and directed . make: anchor roma cat no . 30828 , cona trump , cat no . 15101 or similar make as mentioned in ps . , supply and fix in repairs modular fan step regulator , isi marked 2 module complete all as specified and directed . make: anchor roma cat no . 20507 , cona trump cat no . 15126 or similar make as mentioned in ps . , supply and fix in repairs modular bell push 6a single pole one way , with neon , 1 module complete all as specified and directed . make: anchor roma cat no . 21055 , cona trump cat no . 15021or similar make as mentioned in ps . , m&l sub main wiring complete with 2 runs of 6 sqmm single core pvc insulated fr cable 1100 volts grade multistranded copper conductor cable with 01 run of 6 sqmm single core pvc insulated fr cable 1100 volts grade , multistranded copper conductor cable as earth continuity conductor , drawn through in and including 25 mm or higher dia non metallic rigid pvc conduit and conduit accessories fixed on wall/ceiling/fixed to roof/truss etc including taking down unserviceable submain wiring of any size including gi/copper earth continuity conductor complete all as specified and directed . [note: 2 run 6 sqmm main wire , 1run 6sqm earth wire and necessary pvc non metallic conduit with accessories will be measured in one run] , all as per item no . 24 . 00 described here in before but 2 runs of 4 sqmm and one run of 4 sqmm as earth continuity conductor , drawn through in and including 25 mm or higher dia non metallic rigid pvc conduit and conduit accessories fixed on wall/ceiling/fixed to roof/truss etc including taking down unserviceable submain wiring of any size including gi/copper earth continuity conductor complete all as specified and directed . [note: 2 run 4 sqmm main wire , 1run 4sqm earth wire and necessary pvc non metallic conduit with accessories will be measured in one run] , m&l for sub main wiring complete with 2 runs of 6 sqmm single core pvc insulated fr cable 1100 volts grade multistranded copper conductor cable with 01 run of 6 sqmm single core pvc insulated fr cable 1100 volts grade , multistranded...

Karnataka Power Transmission Corporation Limited - Karnataka

24704630 site survey, planning, testing, design, engineering, supply, erection and commissioning of opgw cable by replacing existing earth wire in 220kv & 400kv transmission lines under buy back in karnataka state (kptcl) on turn key basis ...

Karnataka State Electronics Development Corporation Limited - Karnataka

24631470 providing energy efficient led fittings 1. supplying of feet pvc batten with integrated led tube w with high quality diffuser with life of 25000 burning hours and 70% lumen maintenance with cri > 80. power input: 220 240v 50/60hz and power factor >0.9 along with ce approved. 2 years warranty against any manufacturing defect working under standard electrical condition. led light fitting 2 x 4 20 /22 w all the items includes with all leads and lifts, loading and unloading, cost of materials, labour, hiring of machineries as per standard specifications and as directed by the engineer in charge of the work and other incidental items which are necessary for the successful completion of the work., 2. supplying of feet pvc batten with integrated led tube w with high quality diffuser with life of 25000 burning hours 70% lumen maintenance with cri > 80. power input: 220 240v@ 50/60hz power factor >0.9 along with ce approved. 2 years warranty against any manufacturing defect working under standard electrical condition. led light fitting 1 x 4 20/22 w all the items includes with all leads and lifts, loading and unloading, cost of materials, labour, hiring of machineries as per standard specifications and as directed by the engineer in charge of the work and other incidental items which are necessary for the successful completion of the work., 3. supplying of recess mounting non integral type led w luminaire comprising of pressure decast/extruded aluminium housing, with spring loaded false ceiling clamps, power leds with cct 6500 degree k, cri> 70. efficacy > 100 lumen per watt, 120degree beam spread, life> 25000 burning hours and compliance to is 10322/iec 60598, lm 79 lm 80. the lamp compartment is enclosed with anti glare opal diffuser which enhances the lighting level leds are driven by hf electronic driver integrated in a separate control gear assembly., with pf > 0.95, power loss should< 5 of lamp wattage., short circuit & open circuit protection to be integrated in the circuit, thd less than 20, life as per lm 79. the operating input voltage should be between 130 to 275 volts. bis approved and tested by nabl/cpri accredited laboratory with 2 years warranty against any manufacturing defect working under standard electrical condition. led modular down light 2x2 /1 x 4 34 36watt all the items includes with all leads and lifts, loading and unloading, cost of materials, labour, hiring of machineries as per standard specifications and as directed by the engineer in charge of the work and other incidental items which are necessary for the successful completion of the work., 4. fixing all types and all capacities of fluorescent /false ceiling / spot light / cfl / led fittings indoor on the wall/ ceiling / rafters / girders using 23/0.0076 twin twisted pvc insulated wires, required nos of round blocks and clamps. on wall/ ceiling / rafter / girders all the items includes with all leads and lifts, loading and unloading, cost of materials, labour, hiring of machineries as per standard specifications and as directed by the engineer in charge of the work and other incidental items which are necessary for the successful completion of the work., 5. supplying of .....feet pvc batten with integrated led tube .... w with high quality diffuser with life of 25000 burning hours 70% lumen maintenance with cri > 80. power input: 220 240v@ 50/60hz power factor >0.9 along with ce approved. 2 years warranty against any manufacturing defect working under standard electrical condition. led light fitting 1 x 2 9/10w all the items includes with all leads and lifts, loading and unloading, cost of materials, labour, hiring of machineries as per standard specifications and as directed by the engineer in charge of the work and other incidental items which are necessary for the successful completion of the work., 6. supplying of .....feet pvc batten with integrated led tube .... w with high quality diffuser with life of 25000 burning hours 70% lumen maintenance with cri > 80. power input: 220 240v@ 50/60hz power factor >0.9 along with ce approved. 2 years warranty against any manufacturing defect working under standard electrical condition. led light fitting 1 x 4 20/22 w all the items includes with all leads and lifts, loading and unloading, cost of materials, labour, hiring of machineries as per standard specifications and as directed by the engineer in charge of the work and other incidental items which are necessary for the successful completion of the work., 7. supplying of .....feet pvc batten with integrated led tube .... w with high quality diffuser with life of 25000 burning hours 70% lumen maintenance with cri > 80. power input: 220 240v 50/60hz power factor >0.9 along with ce approved. 2 years warranty against any manufacturing defect working under standard electrical condition. led light fitting 2 x 4 20 /22 wall the items includes with all leads and lifts, loading and unloading, cost of materials, labour, hiring of machineries as per standard specifications and as directed by the engineerincharge of the work and other incidental items which are necessary for the successful completion of the work., 8. supplying of recess mounting non integral type ........ led w luminaire comprising of pressure decast/extruded aluminium housing, with spring loaded false ceiling clamps, power leds with cct 6500 degree k, cri> 70%. efficacy > 100 lumen per watt, 120degree beam spread, life> 25000 burning hours and compliance to is 10322/iec 60598, lm 79 lm 80. the lamp compartment is enclosed with anti glare opal diffuser which enhances the lighting level leds are driven by hf electronic driver integrated in a separate control gear assembly., with pf > 0.95, power loss should< 5% of lamp wattage., short circuit open circuit protection to be integrated in the circuit, thd less than 20%, life as per lm 79. the operating input voltage should be between 130 to 275 volts. bis approved and tested by nabl/cpri accredited laboratory with 2 years warranty against any manufacturing defect working under standard electrical condition. led modular down light 1 x1 34 22watts all the items includes with all leads and lifts, loading and unloading, cost of materials, labour, hiring of machineries as per standard specifications and as directed by the engineer incharge of the work and other incidental items which are necessary for the successful completion of the work., 9. supplying of recess mounting non integral type ........ led w luminaire comprising of pressure decast/extruded aluminium housing, with spring loaded false ceiling clamps, power leds with cct 6500 degree k, cri> 70%. efficacy > 100 lumen per watt, 120degree beam spread, life> 25000 burning hours and compliance to is 10322/iec 60598, lm 79 lm 80. the lamp compartment is enclosed with anti glare opal diffuser which enhances the lighting level leds are driven by hf electronic driver integrated in a separate control gear assembly., with pf > 0.95, power loss should< 5% of lamp wattage., short circuit & open circuit protection to be integrated in the circuit, thd less than 20%, life as per lm 79. the operating input voltage should be between 130 to 275 volts. bis approved and tested by nabl/cpri accredited laboratory with 2 years warranty against any manufacturing defect working under standard electrical condition. led modular down light 2x2 /1 x 4 34 36watt all the items includes with all leads and lifts, loading and unloading, cost of materials, labour, hiring of machineries as per standard specifications and as directed by the engineer in charge of the work and other incidental items which are necessary for the successful completion of the work., 10. led street light : .supply of led streetlight luminaire with pressure die cast aluminium housing body for optimal thermal dissipation. lamp compartment comprising of anti glare clear diffuser with injection moulded polycarbonate material, delivering superior light output rated life burning hrs 50000 hr @ lumen maintenance of 70%, maximum light intensity should be between 60 degrees to 70 degrees. cct > 5500k, ip66 optical and electrical compartment impact resistance of complete luminaire > ik08. power factor >0.9 with mains, surge protection min 5kv along with over voltage/ overload, short circuit/ miss wiring protection. compatible for pole mounting with outer dia of 40mm to 50mm. universal voltage driver to operate wide voltage range from 100v to 270v 50/60hz application. compliance to is 10322/iec 60598, lm 79 lm 80 adherence with rohs. ul approved mcpcb. top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools. led light fixture with ........w system power consumption. led efficiency>1301m/w, nominal cri >75. luminaire manufacturer should have in house facility accredited by nabl/cpri any government certified agency design development facility certified by iso 9001:2008. housing with supplier word mark /name shall be engraved / embossing on the die cast housing/ body part. warranty of 2 years against any manufacturing defect working under standard electrical conditions as mentioned above should be given by led manufacturer cree/nichia/ lumileds/osram make led source. led streetlight 120 watts all the items includes with all leads and lifts, loading and unloading, cost of materials, labour, hiring of machineries as per standard specifications and as directed by the engineer in charge of the work and other incidental items which are necessary for the successful completion of the work., 11. led flood light : .supply of led floodlight luminaire with pressure die cast aluminium housing body for optimal thermal dissipation. lamp compartment comprising of anti glare clear diffuser with injection moulded polycarbonate/clear glass material, delivering superior light output rated life burning hrs 50000 hr @ lumen maintenance of 70%, cct > 5500k, ip 66 optical and electrical compartment impact resistance of complete luminaire > ik08. power factor >0.9 with mains, surge protection min 5kv along with over voltage/ overload, short circuit/ miss wiring protection. compatible for pole mounting with outer dia of 40mm to 50mm. universal voltage driver to operate wide voltage range from 100 v to 270v 50/60hz application. compliance to is 10322/ iec 60598, lm 79 lm 80 adherence with rohs. ul approved mcpcb. top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools. led light fixture with ....... w system power consumption. led efficiency> 1301m/w, nominal cri >75. luminaire manufacturer should have in house facility accredited by nabl / cpri any government certified agency design development facility certified by iso 9001:2008. housing with supplier word mark / name shall be engraved / embossing on the die cast housing / body part warranty of 2 years against any manufacturing defect working under standard electrical conditions as mentioned above should be given by led manufacturer cree/nichia/ lumileds/osram make led source. led floodlight 100w all the items includes with all leads and lifts, loading and unloading, cost of materials, labour, hiring of machineries as per standard specifications and as directed by the engineer in charge of the work and other incidental items which are necessary for the successful completion of the work., 12. led flood light : .supply of led floodlight luminaire with pressure die cast aluminium housing body for optimal thermal dissipation. lamp compartment comprising of anti glare clear diffuser with injection moulded polycarbonate/clear glass material, delivering superior light output rated life burning hrs 50000 hr @ lumen maintenance of 70%, cct > 5500k, ip 66 optical and electrical compartment impact resistance of complete luminaire > ik08. power factor >0.9 with mains, surge protection min 5kv along with over voltage/ overload, short circuit/ miss wiring protection. compatible for pole mounting with outer dia of 40mm to 50mm. universal voltage driver to operate wide voltage range from 100 v to 270v 50/60hz application. compliance to is 10322/ iec 60598, lm 79 lm 80 adherence with rohs. ul approved mcpcb. top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools. led light fixture with ....... w system power consumption. led efficiency> 1301m/w, nominal cri >75. luminaire manufacturer should have in house facility accredited by nabl / cpri any government certified agency design development facility certified by iso 9001:2008. housing with supplier word mark / name shall be engraved / embossing on the die cast housing / body part warranty of 2 years against any manufacturing defect working under standard electrical conditions as mentioned above should be given by led manufacturer cree/nichia/ lumileds/osram make led source. led floodlight 120w all the items includes with all leads and lifts, loading and unloading, cost of materials, labour, hiring of machineries as per standard specifications and as directed by the engineer in charge of the work and other incidental items which are necessary for the successful completion of the work., 13. led flood light : .supply of led floodlight luminaire with pressure die cast aluminium housing body for optimal thermal dissipation. lamp compartment comprising of anti glare clear diffuser with injection moulded polycarbonate/clear glass material, delivering superior light output rated life burning hrs 50000 hr @ lumen maintenance of 70%, cct > 5500k, ip 66 optical and electrical compartment impact resistance of complete luminaire > ik08. power factor >0.9 with mains, surge protection min 5kv along with over voltage/ overload, short circuit/ miss wiring protection. compatible for pole mounting with outer dia of 40mm to 50mm. universal voltage driver to operate wide voltage range from 100 v to 270v 50/60hz application. compliance to is 10322/ iec 60598, lm 79 lm 80 adherence with rohs. ul approved mcpcb. top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools. led light fixture with ....... w system power consumption. led efficiency> 1301m/w, nominal cri >75. luminaire manufacturer should have in house facility accredited by nabl / cpri any government certified agency design development facility certified by iso 9001:2008. housing with supplier word mark / name shall be engraved / embossing on the die cast housing / body part warranty of 2 years against any manufacturing defect working under standard electrical conditions as mentioned above should be given by led manufacturer cree/nichia/ lumileds/osram make led source. led floodlight 200w all the items includes with all leads and lifts, loading and unloading, cost of materials, labour, hiring of machineries as per standard specifications and as directed by the engineer in charge of the work and other incidental items which are necessary for the successful completion of the work., 14. fixing halogen/metal halide /svl/il/led floodlight fitting over existing pole / wall ceiling including clamps, bolts, nuts and wiring using suitable capacity wires. all the items includes with all leads and lifts, loading and unloading, cost of materials, labour, hiring of machineries as per standard specifications and as directed by the engineer in charge of the work and other incidental items which are necessary for the successful completion of the work., 15. fixing all types and all capacities of fluorescent /false ceiling / spot light / cfl / led fittings indoor on the wall/ ceiling / rafters / girders using 23/0.0076 twin twisted pvc insulated wires, required nos of round blocks and clamps. on wall/ ceiling / rafter / girders all the items includes with all leads and lifts, loading and unloading, cost of materials, labour, hiring of machineries as per standard specifications and as directed by the engineer in charge of the work and other incidental items which are necessary for the successful completion of the work., 16. led street light : .supply of led streetlight luminaire with pressure die cast aluminium housing body for optimal thermal dissipation. lamp compartment comprising of anti glare clear diffuser with injection moulded polycarbonate material, delivering superior light output rated life burning hrs 50000 hr @ lumen maintenance of 70%, maximum light intensity should be between 60 degrees to 70 degrees. cct > 5500k, ip66 optical and electrical compartment impact resistance of complete luminaire > ik08. power factor >0.9 with mains, surge protection min 5kv along with over voltage/ overload, short circuit/ miss wiring protection. compatible for pole mounting with outer dia of 40mm to 50mm. universal voltage driver to operate wide voltage range from 100v to 270v 50/60hz application. compliance to is 10322/iec 60598, lm 79 lm 80 adherence with rohs. ul approved mcpcb. top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools. led light fixture with ........w system power consumption. led efficiency>1301m/w, nominal cri >75. luminaire manufacturer should have in house facility accredited by nabl/cpri any government certified agency design development facility certified by iso 9001:2008. housing with supplier word mark /name shall be engraved / embossing on the die cast housing/ body part. warranty of 2 years against any manufacturing defect working under standard electrical conditions as mentioned above should be given by led manufacturer cree/nichia/ lumileds/osram make led source. led streetlight 170 watts all the items includes with all leads and lifts, loading and unloading, cost of materials, labour, hiring of machineries as per standard specifications and as directed by the engineer in charge of the work and other incidental items which are necessary for the successful completion of the work., 17. supplying of recess mounting non integral type ........ led w luminaire comprising of pressure decast/extruded aluminium housing, with spring loaded false ceiling clamps, power leds with cct 6500 degree k, cri> 70%. efficacy > 100 lumen per watt, 120degree beam spread, life> 25000 burning hours and compliance to is 10322/iec 60598, lm 79 lm 80. the lamp compartment is enclosed with anti glare opal diffuser which enhances the lighting level leds are driven by hf electronic driver integrated in a separate control gear assembly., with pf > 0.95, power loss should< 5% of lamp wattage., short circuit open circuit protection to be integrated in the circuit, thd less than 20%, life as per lm 79. the operating input voltage should be between 130 to 275 volts. bis approved and tested by nabl/cpri accredited laboratory with 2 years warranty against any manufacturing defect working under standard electrical condition. led modular down light 2x2 /1 x 4 34 36watt all the items includes with all leads and lifts, loading and unloading, cost of materials, labour, hiring of machineries as per standard specifications and as directed by the engineer in charge of the work and other incidental items which are necessary for the successful completion of the work., 18. supplying of recess mounting non integral type ........ led w luminaire comprising of pressure decast/extruded aluminium housing, with spring loaded false ceiling clamps, power leds with cct 6500 degree k, cri> 70%. efficacy > 100 lumen per watt, 120degree beam spread, life> 25000 burning hours and compliance to is 10322/iec 60598, lm 79 lm 80. the lamp compartment is enclosed with anti glare opal diffuser which enhances the lighting level leds are driven by hf electronic driver integrated in a separate control gear assembly., with pf > 0.95, power loss should< 5% of lamp wattage., short circuit open circuit protection to be integrated in the circuit, thd less than 20%, life as per lm 79. the operating input voltage should be between 130 to 275 volts. bis approved and tested by nabl/cpri accredited laboratory with 2 years warranty against any manufacturing defect working under standard electrical condition. led modular down light 1 x1 34 22watts all the items includes with all leads and lifts, loading and unloading, cost of materials, labour, hiring of machineries as per standard specifications and as directed by the engineer in charge of the work and other incidental items which are necessary for the successful completion of the work., 19. supplying of .....feet pvc batten with integrated led tube .... w with high quality diffuser with life of 25000 burning hours 70% lumen maintenance with cri > 80. power input: 220 240v@ 50/60hz power factor >0.9 along with ce approved. 2 years warranty against any manufacturing defect working under standard electrical condition. led light fitting 2 x 4 20 /22 w all the items includes with all leads and lifts, loading and unloading, cost of materials, labour, hiring of machineries as per standard specifications and as directed by the engineer in charge of the work and other incidental items which are necessary for the successful completion of the work., 20. supplying of .....feet pvc batten with integrated led tube .... w with high quality diffuser with life of 25000 burning hours 70% lumen maintenance with cri > 80. power input: 220 240v@ 50/60hz power factor >0.9 along with ce approved. 2 years warranty against any manufacturing defect working under standard electrical condition. led light fitting 1 x 4 20/22 w all the items includes with all leads and lifts, loading and unloading, cost of materials, labour, hiring of machineries as per standard specifications and as directed by the engineer in charge of the work and other incidental items which are necessary for the successful completion of the work., 21. supply of round/square recess/surface mounted rolling type led down light with ...... w gu 10 led lamp rib fabricated from diecast aluminium with white powder coated prewired to mains connector has swivelling unit of aluminium die cast eye ball led lamp position retained by circular wire spring, with life of 25000 burning hours 70% lumen maintenance with cri > 80. power input: 220 240v @50/60hz power factor >0.9 along with ce approved. 2years warranty against any manufacturing defect working under standard electrical condition led square or round down light 15 18w all the items includes with all leads and lifts, loading and unloading, cost of materials, labour, hiring of machineries as per standard specifications and as directed by the engineer in charge of the work and other incidental items which are necessary for the successful completion of the work., 22. fixing halogen/metal halide /svl/il/led floodlight fitting over existing pole / wall ceiling including clamps, bolts, nuts and wiring using suitable capacity wires. all the items includes with all leads and lifts, loading and unloading, cost of materials, labour, hiring of machineries as per standard specifications and as directed by the engineer in charge of the work and other incidental items which are necessary for the successful completion of the work., 23. fixing all types and all capacities of fluorescent /false ceiling / spot light / cfl / led fittings indoor on the wall/ ceiling / rafters / girders using 23/0.0076 twin twisted pvc insulated wires, required nos of round blocks and clamps. on wall/ ceiling / rafter / girders all the items includes with all leads and lifts, loading and unloading, cost of materials, labour, hiring of machineries as per standard specifications and as directed by the engineer in charge of the work and other incidental items which are necessary for the successful completion of the work., 24. fixing all types and all capacities of fluorescent /false ceiling / spot light / cfl / led fittings indoor on the wall/ ceiling / rafters / girders using 23/0.0076 twin twisted pvc insulated wires, required nos of round blocks and clamps. using necessary length of g.i. chain all the items includes with all leads and lifts, loading and unloading, cost of materials, labour, hiring of machineries as per standard specifications and as directed by the engineer in charge of the work and other incidental items which are necessary for the successful completion of the work., 25. open conduit system :supplying heavy gauge pvc conduit pipe ....... dia ....... mm thick confirming to is 2509 with suitable size bends, junction boxes, adhesive paste etc , and fixing using inverted wood plugs in case of rcc ceiling and rcc wall/ stone structure or rawl plugs in case of brick walls and cement plastering the damaged portion using heavy gauge saddles at an interval of 700mm using nf screws. 25mm dia 2mm thick all the items includes with all leads and lifts, loading and unloading, cost of materials, labour, hiring of machineries as per standard specifications and as directed by the engineer in charge of the work and other incidental items which are necessary for the successful completion of the work., 26. supplying and fixing of pvc casing and capping on the wall or ceiling using necessary materials like bends, junction box, elbows, screws at an interval of 300mm .... etc. as required. 25mm all the items includes with all leads and lifts, loading and unloading, cost of materials, labour, hiring of machineries as per standard specifications and as directed by the engineer in charge of the work and other incidental items which are necessary for the successful completion of the work., 27. point wiring using copper wire with switch. supplying and wiring adopting loop system in existing pvc conduit /casing capping using 2x1.5sqmm (phase neutral) 1x1.0 sqmm (earth wire) frls multi strand pvc insulated copper wire (confirming to is 694: and latest amendments) with a 6amps flush type sp control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/pvc round block. complete for each outlet. long point above 6mtr upto 10mtr from tapping point to out let via switch all the items includes with all leads and lifts, loading and unloading, cost of materials, labour, hiring of machineries as per standard specifications and as directed by the engineer in charge of the work and other incidental items which are necessary for the successful completion of the work., 28. wiring for lighting/power circuit using one of frls pvc insulated 1100v grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified is 694:confirming to latest amendments.the following additional tests are compulsory either to be conducted at works or independent lab with witness by inspecting authority.additional tests for frls applicable standard oxygen index is 694 1990, clause 16.8 temperature index is 694 1990, clause 16.13 smoke density is 694 1990, clause 16.14 test for halogen acid gas evaluation is 694 1990, clause 16.12 1 sqmm. all the items includes with all leads and lifts, loading and unloading, cost of materials, labour, hiring of machineries as per standard specifications and as directed by the engineer in charge of the work and other incidental items which are necessary for the successful completion of the work., 29. wiring for lighting/power circuit using one of frls pvc insulated 1100v grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified is 694:confirming to latest amendments.the following additional tests are compulsory either to be conducted at works or independent lab with witness by inspecting authority.additional tests for frls applicable standard oxygen index is 694 1990, clause 16.8 temperature index is 694 1990, clause 16.13 smoke density is 694 1990, clause 16.14 test for halogen acid gas evaluation is 694 1990, clause 16.12 1.5 sqmm all the items includes with all leads and lifts, loading and unloading, cost of materials, labour, hiring of machineries as per standard specifications and as directed by the engineer in charge of the work and other incidental items which are necessary for the successful completion of the work., 30. wiring for lighting/power circuit using one of frls pvc insulated 1100v grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified is 694:confirming to latest amendments.the following additional tests are compulsory either to be conducted at works or independent lab with witness by inspecting authority.additional tests for frls applicable standard oxygen index is 694 1990, clause 16.8 temperature index is 694 1990, clause 16.13 smoke density is 694 1990, clause 16.14 test for halogen acid gas evaluation is 694 1990, clause 16.12 2.5 sqmm all the items includes with all leads and lifts, loading and unloading, cost of materials, labour, hiring of machineries as per standard specifications and as directed by the engineer in charge of the work and other incidental items which are necessary for the successful completion of the work., 31. led street light : .supply of led streetlight luminaire with pressure die cast aluminium housing body for optimal thermal dissipation. lamp compartment comprising of anti glare clear diffuser with injection moulded polycarbonate material, delivering superior light output rated life burning hrs 50000 hr @ lumen maintenance of 70%, maximum light intensity should be between 60 degrees to 70 degrees. cct > 5500k, ip66 optical and electrical compartment & impact resistance of complete luminaire > ik08. power factor >0.9 with mains, surge protection min 5kv along with over voltage/ overload, short circuit/ miss wiring protection. compatible for pole mounting with outer dia of 40mm to 50mm. universal voltage driver to operate wide voltage range from 100v to 270v 50/60hz application. compliance to is 10322/iec 60598, lm 79 & lm 80 adherence with rohs. ul approved mcpcb. top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools. led light fixture with w system power consumption. led efficiency>1301m/w, nominal cri >75. luminaire manufacturer should have in house facility accredited by nabl/cpri any government certified agency design development facility certified by iso 9001 2008. housing with supplier word mark /name shall be engraved / embossing on the die cast housing/ body part. warranty of 2 years against any manufacturing defect working under standard electrical conditions as mentioned above should be given by led manufacturer cree/nichia/ lumileds/osram make led source. led streetlight 200 watts all the items includes with all leads and lifts, loading and unloading, cost of materials, labour, hiring of machineries as per standard specifications and as directed by the engineer in charge of the work and other incidental items which are necessary for the successful completion of the work., 32. supplying of feet pvc batten with integrated led tube w with high quality diffuser with life of 25000 burning hours 70 lumen maintenance with cri > 80. power input: 220 240v@ 50/60hz power factor >0.9 along with ce approved. 2 years warranty against any manufacturing defect working under standard electrical condition. led light fitting 1 x 4 20/22 wall the items includes with all leads and lifts, loading and unloading, cost of materials, labour, hiring of machineries as per standard specifications and as directed by the engineer in charge of the work and other incidental items which are necessary for the successful completion of the work., 33. 18 20 watts all the items includes with all leads and lifts, loading and unloading, cost of materials, labour, hiring of machineries as per standard specifications and as directed by the engineer in charge of the work and other incidental items which are necessary for the successful completion of the work., 34. supplying of feet pvc batten with integrated led tube w with high quality diffuser with life of 25000 burning hours 70 lumen maintenance with cri > 80. power input: 220 240v@ 50/60hz power factor >0.9 along with ce approved. 2 years warranty against any manufacturing defect working under standard electrical condition. led light fitting 2 x 4 20 /22 w all the items includes with all leads and lifts, loading and unloading, cost of materials, labour, hiring of machineries as per standard specifications and as directed by the engineer in charge of the work and other incidental items which are necessary for the successful completion of the work., 35. led flood light .supply of led floodlight luminaire with pressure die cast aluminium housing body for optimal thermal dissipation. lamp compartment comprising of anti glare clear diffuser with injection moulded polycarbonate/clear glass material, delivering superior light output rated life burning hrs 50000 hr lumen maintenance of 70, cct > 5500k, ip 66 optical and electrical compartment impact resistance of complete luminaire > ik08. power factor >0.9 with mains, surge protection min 5kv along with over voltage/ overload, short circuit/ miss wiring protection. compatible for pole mounting with outer dia of 40mm to 50mm. universal voltage driver to operate wide voltage range from 100 v to 270v 50/60hz application. compliance to is 10322/ iec 60598, lm 79 lm 80 adherence with rohs. ul approved mcpcb. top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools. led light fixture with w system power consumption. led efficiency> 1301m/w, nominal cri >75. luminaire manufacturer should have in house facility accredited by nabl / cpri any government certified agency design development facility certified by iso 9001 2008. housing with supplier word mark / name shall be engraved / embossing on the die cast housing / body part warranty of 2 years against any manufacturing defect working under standard electrical conditions as mentioned above should be given by led manufacturer cree/nichia/ lumileds/osram make led source. led floodlight 240w all the items includes with all leads and lifts, loading and unloading, cost of materials, labour, hiring of machineries as per standard specifications and as directed by the engineer in charge of the work and other incidental items which are necessary for the successful completion of the work., 36. supply of round/square recess/surface mounted rolling type led down light with w gu 10 led lamp rib fabricated from diecast aluminium with white powder coated prewired to mains connector has swivelling unit of aluminium die cast eye ball led lamp position retained by circular wire spring, with life of 25000 burning hours & 70 lumen maintenance with cri > 80. power input: 220 240v @50/60hz power factor >0.9 along with ce approved. 2years warranty against any manufacturing defect working under standard electrical condition led square or round down light 15 18w all the items includes with all leads and lifts, loading and unloading, cost of materials, labour, hiring of machineries as per standard specifications and as directed by the engineer in charge of the work and other incidental items which are necessary for the successful completion of the work., 37. supplying of recess mounting non integral type led w luminaire comprising of pressure decast/extruded aluminium housing, with spring loaded false ceiling clamps, power leds with cct 6500 degree k, cri> 70. efficacy > 100 lumen per watt, 120degree beam spread, life> 25000 burning hours and compliance to is 10322/iec 60598, lm 79 lm 80. the lamp compartment is enclosed with anti glare opal diffuser which enhances the lighting level leds are driven by hf electronic driver integrated in a separate control gear assembly., with pf > 0.95, power loss should< 5% of lamp wattage., short circuit open circuit protection to be integrated in the circuit, thd less than 20, life as per lm 79. the operating input voltage should be between 130 to 275 volts. bis approved and tested by nabl/cpri accredited laboratory with 2 years warranty against any manufacturing defect working under standard electrical condition. led modular down light 2x2 /1 x 4 34 36watt all the items includes with all leads and lifts, loading and unloading, cost of materials, labour, hiring of machineries as per standard specifications and as directed by the engineer in charge of the work and other incidental items which are necessary for the successful completion of the work., 38. fixing all types and all capacities of fluorescent /false ceiling / spot light / cfl / led fittings indoor on the wall/ ceiling / rafters / girders using 23/0.0076 twin twisted pvc insulated wires, required nos of round blocks and clamps. on wall/ ceiling / rafter / girders all the items includes with all leads and lifts, loading and unloading, cost of materials, labour, hiring of machineries as per standard specifications and as directed by the engineer in charge of the work and other incidental items which are necessary for the successful completion of the work., 39. fixing all types and all capacities of fluorescent /false ceiling / spot light / cfl / led fittings indoor on the wall/ ceiling / rafters / girders using 23/0.0076 twin twisted pvc insulated wires, required nos of round blocks and clamps. using necessary length of g.i. chain all the items includes with all leads and lifts, loading and unloading, cost of materials, labour, hiring of machineries as per standard specifications and as directed by the engineer in charge of the work and other incidental items which are necessary for the successful completion of the work., 40. fixing halogen/metal halide /svl/il/led floodlight fitting over existing pole / wall ceiling including clamps, bolts, nuts and wiring using suitable capacity wires. all the items includes with all leads and lifts, loading and unloading, cost of materials, labour, hiring of machineries as per standard specifications and as directed by the engineer in charge of the work and other incidental items which are necessary for the successful completion of the work., 41. supplying and fixing of pvc casing and capping on the wall or ceiling using necessary materials like bends, junction box, elbows, screws at an interval of 300mm etc. as required. 25mm all the items includes with all leads and lifts, loading and unloading, cost of materials, labour, hiring of machineries as per standard specifications and as directed by the engineer in charge of the work and other incidental items which are necessary for the successful completion of the work., 42. wiring for lighting/power circuit using one of frls pvc insulated 1100v grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified is 694:confirming to latest amendments.the following additional tests are compulsory either to be conducted at works or independent lab with witness by inspecting authority.additional tests for frls applicable standard oxygen index is 694 1990, clause 16.8 temperature index is 694 1990, clause 16.13 smoke density is 694 1990, clause 16.14 test for halogen acid gas evaluation is 694 1990, clause 16.12 1.5 sqmm all the items includes with all leads and lifts, loading and unloading, cost of materials, labour, hiring of machineries as per standard specifications and as directed by the engineer in charge of the work and other incidental items which are necessary for the successful completion of the work., 43. wiring for lighting/power circuit using one of frls pvc insulated 1100v grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified is 694:confirming to latest amendments.the following additional tests are compulsory either to be conducted at works or independent lab with witness by inspecting authority.additional tests for frls applicable standard oxygen index is 694 1990, clause 16.8 temperature index is 694 1990, clause 16.13 smoke density is 694 1990, clause 16.14 test for halogen acid gas evaluation is 694 1990, clause 16.12 1 sqmm. all the items includes with all leads and lifts, loading and unloading, cost of materials, labour, hiring of machineries as per standard specifications and as directed by the engineer in charge of the work and other incidental items which are necessary for the successful completion of the work., 44. wiring for lighting/power circuit using one of frls pvc insulated 1100v grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified is 694:confirming to latest amendments.the following additional tests are compulsory either to be conducted at works or independent lab with witness by inspecting authority.additional tests for frls applicable standard oxygen index is 694 1990, clause 16.8 temperature index is 694 1990, clause 16.13 smoke density is 694 1990, clause 16.14 test for halogen acid gas evaluation is 694 1990, clause 16.12 2.5 sqmm all the items includes with all leads and lifts, loading and unloading, cost of materials, labour, hiring of machineries as per standard specifications and as directed by the engineer in charge of the work and other incidental items which are necessary for the successful completion of the work., 45. point wiring using copper wire with switch. supplying and wiring adopting loop system in existing pvc conduit /casing capping using 2x1.5sqmm (phase neutral) 1x1.0 sqmm (earth wire) frls multi strand pvc insulated copper wire (confirming to is 694 and latest amendments) with a 6amps flush type sp control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/pvc round block. complete for each outlet. long point above 6mtr upto 10mtr from tapping point to out let via switch all the items includes with all leads and lifts, loading and unloading, cost of materials, labour, hiring of machineries as per standard specifications and as directed by the engineer in charge of the work and other incidental items which are necessary for the successful completion of the work., 46. supplying fixing of surface mounting type retrofit type led tube w comprising of led linear source with cct 6500 degree k, cri> 70. efficacy >80 lumen per watt, life> 25000 burning hours and compliance to is 10322/iec 60598, lm 79 lm 80. the led are driven by hf electronic driver integrated in the system, with pf > 0.95, power loss should < 5 of lamp wattage., short circuit open circuit protection to be integrated in the circuit, thd less than 20, life as per lm 79. the operating input voltage should be between 130 to 275 volts. bis approved and tested by nabl/cpri accredited laboratory with 2 years warranty against any manufacturing defect working under standard electrical condition. 18w 20w (t8) glass casing all the items includes with all leads and lifts, loading and unloading, cost of materials, labour, hiring of machineries as per standard specifications and as directed by the engineer in charge of the work and other incidental items which are necessary for the successful completion of the work., ...

National Thermal Power Corporation Limited - Karnataka

24595141 balance electrical works of ntpc kudgi stpp , etc of outdoor transformers , 2 mva outdoor transformer , 1 . 6 / 1 mva out door transformer , ngr , installation of cable trays and accessor , ladder type 150 mm width tray , ladder type 300 mm width tray , fixing of c2 type channel , cantilever arms: 320mm , lighting works , lighting panels , galvanised steel rigid conduit , 20mm dia , galvanised steel rigid conduit , 25mm dia , gi fiexible conduit , laying of 1 . 5mm2 , cu . pvc wires in condu , laying of 4mm2 , al . pvc wires in condui , junction boxes type f ( frp type ) , laying of 14 swg gi earth wire , type swb1 , type swb2 , type swb3 , type swb4 , fixing and comm of light fixtures , earth / lightning protection conductors & , 20 mm dia . m . s . rod earth conductor , 65x8 mm g . s . flat , 25x6 mm g . s . flat , treated earth pit alongwith required acc , laying of ht cables , 11kv & 3 . 3kv , 1cx300 sqmm cable , 11kv & 3 . 3kv , 1cx150 sqmm cable , 11kv & 3 . 3kv 3cx150sqmm cables , laying of lt and control cables , 1 . 1kv , pvc 2 . 5 sqmm cable , 1 . 1kv , pvc 3cx6 sqmm cable , 1 . 1kv , pvc 3cx10 sqmm cable , 1 . 1kv , pvc 3cx16 sqmm cable , 1 . 1kv , pvc 3cx25 sqmm cable , 1 . 1kv , pvc 3cx35 sqmm cable , 1 . 1kv , pvc 3cx50 sqmm cable , 1 . 1kv , pvc 3cx70 sqmm cable , 1 . 1kv , pvc 3cx240 sqmm cable , 1 . 1kv , pvc 3cx300 sqmm cable , 1 . 1kv , pvc 3 . 5cx300sqmm cable , 1 . 1kv , pvc 3 . 5x120 sqmm cable , 1 . 1kv , pvc 3 . 5x35 sqmm cable , 1 . 1kv , pvc 3 . 5x50 sqmm cable , 1 . 1kv , pvc 3 . 5x70 sqmm cable , 1 . 1kv , pvc 3 . 5x95 sqmm cable , 1 . 1kv , pvc 4cx6 sqmm cable , 1 . 1kv , pvc 4cx16 sqmm cable , 1 . 1kv , 1cx150 sqmm cable , 1 . 1kv , 1cx300 sqmm cable , 1 . 1kv , 1cx630 sqmm cable , 1 . 1kv , 3cx150 sqmm cable , 1 . 1kv , laying of cable of size up to 35 , 1 . 1kv , laying of cable of size bove 35 s , 5cx1 . 5 sqmm control cable , 7cx1 . 5 sqmm control cable , 10cx1 . 5 sqmm control cable , laying of under ground cables , 1 . 1kv , pvc , up to 25 sqmm cables , 1 . 1kv , pvc , abpove 25 sqmm to 120 sqmm , 11kv , xlpe , above 120 sqmm to 240 sqmm , 11kv , xlpe , 1cx300 sqmm cable , ht cable termination , 11 / 11 kv grade , alumium , 3cx150mm2 cable , 11 / 11 kv grade , alumium , 1cx300mm2 cable , 3 . 3 / 3 . 3kv grade , alumium , 3cx150mm2 cable , 3 . 3 / 3 . 3kv grade , alumium , 1cx150mm2 cable , 3 . 3 / 3 . 3kv grade , alumium , 3cx150mm2 cable , lt and control cable termination , 1 . 1kv , pvc 3cx2 . 5 sqmm cable , 1 . 1kv , pvc 3cx6 sqmm cable , 1 . 1kv , pvc 3cx10 sqmm cable , 1 . 1kv , pvc 3cx16 sqmm cable , 1 . 1kv , pvc 3cx25 sqmm cable , 1 . 1kv , pvc 3cx35 sqmm cable , 1 . 1kv , pvc 3cx50 sqmm cable , 1 . 1kv , pvc 3cx70 sqmm cable , 1 . 1kv , pvc 3cx240 sqmm cable , 1 . 1kv , pvc 3cx300 sqmm cable , 1 . 1kv , pvc 3 . 5cx300sqmm cable , 1 . 1kv , pvc 3 . 5x120 sqmm cable , 1 . 1kv , pvc 3 . 5x35 sqmm cable , 1 . 1kv , pvc 3 . 5x50 sqmm cable , 1 . 1kv , pvc 3 . 5x70 sqmm cable , 1 . 1kv , pvc 3 . 5x95 sqmm cable , 1 . 1kv , pvc 4cx6 sqmm cable , 1 . 1kv , pvc 4cx16 sqmm cable , 1 . 1 kv grade , 1cx150 mm2 ( ua ) al . cable , 1 . 1 kv 1cx300 mm2 ( ua ) , al cable , 1 . 1 kv grade , 1cx630 mm2 ( ua ) , al . cable , 1 . 1 kv grade , 3cx150 mm2 ( ua ) , al . cable , 1 . 1 kv grade , 4cx16 mm2 ( a ) , alu . cable , a ) 2cx2 . 5 mm2 ( ua ) , e ) 5cx1 . 5 mm2 ( ua ) , f ) 7cx1 . 5 mm2 ( ua ) , g ) 10cx1 . 5 mm2 ( ua ) , stright through jointing of ht cables , 11kv , 3cx150mm2 cables , 11kv , 1cx300mm2 cables , 3 . 3kv 1cx150mm2 cables , st / th joint lt and control cables , 5cx1 . 5 mm2 cable , 7cx1 . 5 mm2 cable , 10cx1 . 5 mm2 cable , laying of gi pipe in road crosising , a ) 50 mm 200 dia . , manpower deployment , highly skilled , skilled , unskilled , safet item highly skilled , safet item skilled , safet item unskilled , etc of switchgear / ldb / lp & miscellaneous , ac ldb type a with one vertical panel , ac ldb type b with two vertical panel , dc ldb with one vertical panel , switchyard emergency ac ldb with one ver , hfo unloading switchgear , auditorium mcc , administration building switchgear , 11kv make up water stand alone panel , 11kv raw water stand alone panel , 11kv , admin building stand alone panel , 3 . 3kv ahp spare panel , lt busduct 3000a type b 2sets , lt busduct 1600a type f 2sets , support steel structure , dc fuse board , local motor starters ( exhaust fans ) , local push button stations , lighting transformer ( 100kva ) , ethernet switch fixing , fo cable laying 4 fiber , fo cable splicing , lan cable cat 5e , fixing of rubber mats ( insulation mats f...

Military Engineer Services - Karnataka

23713495 repair / replacement of certain fire fighting equipments and periodical maintenance of ht / lt equipments at lrde under ge ( i ) rndd ( west ) bengaluru 1.00 excavation in trenches not exceeding 1.5 m deep and not exceeding 1.5 m wide and getting out in hard / dense soil all as directed. 2.00 returning and filling in, soils, including spreading, leveling, watering and well ramming in layers not exceeding 25cm thick all as directed. 3.00 removing excavated surplus soil to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point all as directed. 4.00 taking down existing unserviceable 11 kv grade cable, supply and laying new 11 kv grade, xlpe insulated, screened, bedded galvanised steel strip / wire armoured heavy duty with aluminum conductor, of cross sectional area 120 sqmm 3 core with cable protection works ( as applicable ) laid in trenches / ducts / fixed on pole / wall / laid under road / path / culvert / drains / encased in pipe, jointing and testing complete all as specified and as directed. 5.00 taking down existing unserviceable, 1100 volts grade cable, supply and lay new 1100 v grade, xlpe insulated, screened, bedded galvanised steel strip / wire armoured heavy duty with aluminium conductor of cross sectional area 300 sqmm 3.5 core with cable protection works ( as aplicable ) laid in trenches / ducts / fixed on pole / wall / laid under road / path / culvert / drains / encased in pipe, including necessary lugs, joiniting and tesing complete all as specified and as directed. 6.00 taking down existing unserviceable, 1100 volts grade cable, supply and lay new 1100 v grade, xlpe insulated, screened, bedded galvanised steel strip / wire armoured heavy duty with aluminium conductor of cross sectional area 185 sqmm 3.5 core with cable protection works ( as aplicable ) laid in trenches / ducts / fixed on pole / wall / laid under road / path / culvert / drains / encased in pipe, including necessary lugs, joiniting and tesing complete all as specified and as directed. 7.00 taking down existing unserviceable, 1100 volts grade cable, supply and lay new 1100 v grade, xlpe insulated, screened, bedded galvanised steel strip / wire armoured heavy duty with aluminium conductor of cross sectional area 95 sqmm 3.5 core with cable protection works ( as aplicable ) laid in trenches / ducts / fixed on pole / wall / laid under road / path / culvert / drains / encased in pipe, including necessary lugs, joiniting and tesing complete all as specified and as directed. note for serial item nos 4 to 7 : necessary excavation, earthwork and cable protection works will be measured and paid for separately under respective items. 8.00 supply, install, test and commissioning of, apfc panel comprising of following components, 100 kvar capacity, suitable for 3 phase, 3 / 4 wire, 415 volts, 50 hz, automatic switching, natural cooled, with pf control, ip 55 protection, 2 mm thick powder coated crca sheet enclsoure, with locking arrangement, and connecting complete after taking out unserviceable apfc panel complete all as directed : ( make : cat part no qhktcb5100x0 of havells or techno commerical equivalent in indoasian / standard / neptune systems pvt ltd., / schnieder / l&t ) . i ) indication lamps set of 3 ( r y b phase ) 1 set ii ) digital vif meter 1 no iii ) cts for metering 1 no iv ) apfc relay, 6 stage built in pf meter 1 no v ) selector switch, auto 1 no vi ) axial flow fan, heavy duty 2 nos vii ) thermostat 1 no viii ) control fuse 4 a 3 nos ix ) control mcb, 6a, 10 ka, sp 5 nos 8.01 sl item no 8.00 ( contd., ) x ) mcb, 32 a, tp, 10 ka 1 no xi ) mcb, 40 a, tp, 10 ka 2 nos xii ) mccb, 63 a, tp, 10 ka 3 nos xiii ) mccb, 250 a, tp, 415 v, 25 ka with thermal magnetic release for o / c & s / c protection 1 no xiv ) capcitor duty contactor, 5 kvar 1 no xv ) capacitor duty contactor, 10 kvar 2 no xvi ) capacitor duty contactor, 25 kvar 3 nos xvii ) capacitor bank, 440v, 50 hz, heavy duty capacitor banks, cylindrical, capacitors 5 kvar 1 no xviii ) capacitor bank, 440v, 50 hz, heavy duty capacitor banks, cylindrical, capacitors, 10 kvar 2 nos xix ) capacitor bank, 440v, 50 hz, heavy duty capacitor banks, cylindrical, capacitors, 25 kvar 3 no xx ) push button, start / stop 6 nos xxi ) indication lamps, on 6 nos xxii ) busbar, 300 a, tp, aluminium 1 set of 4 xxiii ) timer on delay relay 1 no. 9.00 supply and fix in repairs, ht fuse 63 amps suitable for sm 6 switch gears 11 kv all as specified and as directed. make : schneider or equivalent approved make 10.00 supply and fix in repairs, ht fuse 32 amps suitable for sm 6 switch gears 11 kv all as specified and as directed. make : schneider or equivalent approved make 11.00 material and labour for laying of reinforced precast concrete cable cover, class hv, type 1 flat size 300mm x 180mm x 40mm all as directed and specified 12.00 material and labour for sand cushioning using dry river sand for cable cushioning all as directed and specified. note : for the purpose of payment punned thickness will be measured. 13.00 material and labour for laying of burnt bricks sub class `b’ bricks of size 230 x 115 x 75 mm, laid in trenches for cable protection all as directed and specified 14.00 relaying of burnt bricks sub class b bricks of old size obtained from excavation of trenches complete all as specified and as directed 15.00 taking out old unserviceable joints, supply, jointing & testing heat shrink, straight through cable jointing kit suitable for 1100 v, xlpe cable of size 3.5 core 70 to 150 sqmm complete all as specified and as directed 16.00 taking out old unserviceable joints, supply, jointing & testing heat shrink, end termination cable jointing kit suitable for 1100 v, xlpe cable of size 3.5 core 185 to 300 sqmm complete all as specified and as directed 17.00 taking out old unserviceable joints, supply, jointing & testing, out door type, ht cable, end termination, heat shrinkable jointing kit suitable for 11000 v, xlpe cable of size 3 core 95 to 185 sqmm complete all as specified and as directed 18.00 taking out old unserviceable joints, supply, jointing & testing, out door type, ht cable, straight through, heat shrinkable jointing kit suitable for 11000 v, xlpe cable of size 3 core 95 to 185 sqmm complete all as specified and as directed 19.00 supply and fix aluminium lugs suitable for cable of size 120 to 185 sq mm complete all as specifieid and as directed. 20.00 supply and fix aluminium lugs suitable for cable of size 240 to 400 sq mm complete all as specifieid and as directed. 21.00 supply and fix aluminium lugs suitable for cable of size 35 to 95 sq mm complete all as specifieid and as directed. 22.00 taking down unserviceable cable protection pipe of 80 mm dia, supply and fixing / laying on walls / pole / trenches, 80 mm bore galvanised iron tubing, light grade, as cable protection, including necessary clamps, etc., complete all as specified and as directed. 23.00 spply, install lead cadmium battery dry type, 2.1 v, dc power bank, suitable for power bank assembly of vcbs inlcuding taking down old unserviceable from battery power bak, compelte all as specified and as directed. make : exide / amco / sf. 24.00 earthing complete with galvanised steel earth plate electrode 60 cm x 60 cm x 6.3 mm thick burried directly in ground ( earth pit not less than 2.25 m deep belopw ground level ) with top edge of the plate not less than 1.5 m below normal ground level, connected to galvanised earth strip of 25 x 4 mm by means of bolts, nuts and washers of galvanised iron or steel all as shown in elecrtical plate 3, connected to earthing test point including excavation earth work pcc chamber rcc over 50mm thick with 8 mm dia bars @ 100 c / c on both ways, 40 mm dia gi light grade protection pipe, funnel, excavation, earth work, disposal of surplus soil to a distance not exceeding 50 m and earth wire and protection pipe of gi 15 mm bore light grade upto 7.5 metre including testing on completion all as specified and directed. 25.00 material and labour, galvanised earth strip of size 25 x 4 mm earth continuity or main earthing lead fixed to wall / trenches / ducts through galvanised iron pipe including necessary clamps, nuts, bolts, etc., and conecting up complete all as specified and as directed. 26.00 supply and fix in repairs, voltmeter digital type 96 x96 mm size range 0 650 v with built in selector switch, ultra bright led display suitable for 3 phase, 415 v with necessary back plate to suit in existing slot of analog meter and wiring ( copper conductor cable 1.5 sqmm 6 rm approx ) complete all as specified and as directed. 27.00 supply and fix in repairs, ammeter digital type 96 x96 mm with built in selector switch , ultra bright led display suitable for 3 phase, 415 v to accommodate necessary alteration work to suit in existing slot of analog meter and wiring ( copper conductor cabkle 1.5 sqmm 6 rm approx ) complete including taking out old meter all as specified and as directed. 28.00 supply and fix in repairs, selector switch suitable for voltmeter / ammeter, 3 phase, 50 hz, complete all as specified and as directed. 29.00 supply and fix in repairs, ct ratio coil 600 / 5 amps of 230 volt ( set of 3 ) complete all as specified and as directed. 30.00 supply and fix in repairs, ct ratio coil 400 / 5 amps of 230 volt ( set of 3 ) complete all as specified and as directed. 31.00 supply and fix in repairs, neon indicator lamps ryb 3 phase ( set of 03 ) complete all as specified and as directed. 32.00 calibration of idmtl relays comprising to over current and earth fault at ht systems through primary and secondary injection method and testing complete of control relays panels installed with ht ocb / vcbs panels and all as directed 33.00 repairing of potential transformer ( pt ) 11 kv / 110 v withdrawable type with automatic shutters by disconnecting pt from main power supply of ocb / vcb panel, separating fixed and moving chambers opening of covers, cleaning, meggering the windings etc & commmissioning after replacement of following unserviceable spare parts complete all as specified and as directed. note : i ) spare parts, components will be measured and paid separately as supply only under relevant items of this schedule. ii ) components / accessories to be replaced shall be inspected and approved by engineer in charge, iii ) replacement of screws, nuts, bolts and consumables shall be deemed to be included in the rate quoted and no extra payment shall be aloowed. iv ) all the retrieved items will be offered under schedule of credit, and in case items not included in schedule of credit, the same shall be returned to age e / m storeyard. 34.00 supply only fixed contacts of vcbs, all as specified and as directed. 35.00 supply only moving contacts of vcbs all as specified and as directed. 36.00 supply and fix, transformer ( 160 kva to 1000 kva ) , breather assembly with silica gel filled including removing the unserviceable breather unit of 1000 gm capacity complete all as specified and as directed. 37.00 supply only isi marked transformer oil in sealed drum and topping up of transformer oil in transformers and ht ocbs after filtration with 50 to 60 kv / min of die electric strength of oil by high vacuum oil filtration plant complete all as specified and as directed. 38.00 disconnecting the ht power transformer of any capacity from main power supply and carrying out oil filtration through high vacuum oil filtration plant, extracting the moisture content, dust, sludge and carbon deposits from oil and bringing to 40 kv / min die electric strength through 2.5 mm gap of testing electrode including carrying out acidity and di electric strength test before and after oil filtration and submission of test certificate complete all as specified and as directed. 39.00 supply and fix, ht brass spindles with porcelain bush of power distribution transformer of capacity 315 kva to 500 kva including taking out unserviceable spindle complete all as specified and as directed. 40.00 supply and fill dehydrating breather with first fill dehydrating agent ( silica gel ) supply and fix dehydrating agent ( silica gel ) of power distribution transformers including taking out unserviceable silica gel complete all as specified and as directed. 41.00 detection / localisation of fault in ht 11 kv ug cable of any size and length, by means of cable fault locator including pinpointing the exact location of fault , retrieving the exposing damaged portion carefully for further inspection and repairs complete all as specified and as directed . notes : ( i ) charges for cable fault equipment carried out by bescom / other agencies are deemed to be included in the item rate quoted ( ii ) contractor on demand by the department has to arrange the above equipment without any delay failing which necessary penalty will be levied by the department. 42.00 supply and fix, ajustable type, mccb, 4 pole, 415 volts, 400 amps, 35 / 36 ka breaking capacity including taking out old unserviceable mccb complete all as specified and as directed. 43.00 supply and fix, adjustable type, mccb, 4 pole, 415 volts, 315 amps, 35 / 36 ka breaking capacity including taking out old unserviceable mccb complete all as specified and as directed. 44.00 supply and fix, adjustable type mccb, 4 pole, 415 volts, 250 amps, 35 / 36 ka breaking capacity including taking out old unserviceable mccb complete all as specified and as directed. 45.00 supply and fix, adjustable type, mccb, 4 pole, 415 volts, 200 amps, 35 / 36 ka breaking capacity including taking out old unserviceable mccb complete all as specified and as directed. 46.00 supply and fix, adjustable type, mccb, 3 pole, 415 volts, 100 amps, 16 ka breaking capacity including taking out old unserviceable mccb complete all as specified and as directed. 47.00 supply and fix, adjustable type, mccb, 4 pole, 415 volts, 100 amps, 16 ka breaking capacity including taking out old unserviceable mccb complete all as specified and as directed. 48.00 supply and fix, adjustable type, mccb, 4 pole, 415 volts, 63 amps, 16 ka breaking capacity including taking out old unserviceable mccb complete all as specified and as directed. 49.00 supply and fix, adjustable type, mccb, 4 pole, 415 volts, 32 amps, 16 ka breaking capacity including taking out old unserviceable mccb complete all as specified and as directed. 50.00 servicing and repairing of lt air circuit breaker by drawing out acb mechanically from cabinet, cleaning entire parts, greasing, oiling, tightening of nuts / bolts and replacing unserviceable spare parts and reassembling the same, complete all as specified and as directed. note : spare parts to be replaced will be measured and paid for separately as supply only under respective items of this schedule. 51.00 cleaning the surfaces of transformer, lt panels, preparing and applying one coat of smoke grey synthetic enamel paint, over 10 cm width or girth, not otherwise specified, complete all as specified and as directed. 52.00 disconnecting the ht vaccum circuit breaker ( vcb ) of any capacity and take from main power supply, carrying out servicing of ht vcbs 400 / 630 amps capacity by drawing out the vcb trolley from the ht panel, opening the top cover of oil tank, drain out the oil in moisture proof drum, cleaning of entire parts of switch gear such as fixed and breaking mechanism with emery paper, cotton waste etc., checking for proper alignment for smooth movement of fixed and moving contacts after applying petroleum jelly, tightening of screw, bolts, nuts etc, filling of the tank with oil after filtration and checking of all internal wiring, re assembling the vcb in position, connecting vcb with main power supply and testing to the satisfaction of engineer in charge. note: shut down available on user permissions. 53.00 supply only under voltage release coil 230 v, 50 hz, suitable for lt acb. 54.00 supply only shunt release coil 230 v, 50 hz, suitable for lt acb.. 55.00 supply only closing coil 230 v, 50 hz, suitable for lt acb. 56.00 material and labour for pvc sheathed, 1100 v grade, copper bunched conductor cable of 2 core 1.5 sq mm, drawn through and including pvc rigid conduit, medium grade, 19 / 20 mm dia with conduit accessories and fixed on wall surfaces complete all as specified and as directed. note : pvc conduit along with cable will be measured as one unit. 57.00 supply, install, test and commissioning of conventional hooter, wall mounted, 80 db at 1 m disance, operative on 240 v, dc supply, piezo electric type, operating current, 40 ma, complete all as specified and as directed. make : system sensor / ravel / dixi. 58.00 supply, install, test and commissioning of 12v, 7 ah battery, complete all as specified and as directed. 59.00 supply and installing single loop card that can support around 159 detector and 159 devices all as per cat no . slc of notifier make or its techno commercially equivalent model in other makes complete all as specified and as directed. 60.00 supply only intelligent addressable smoke detector along with base and individual smoke sensitivity with a provision for selectable temperature operation for each sensor, having photo sensor sensitivity from 0.2% to 3.7% per 300 mm obscuration, digital communication support and magnetically operated functional test as per ul & ulc listing & csfm, mea, fm approval complete all as specified and as directed. make: notifier cat no: fsp 851+b501 or its techno commercially equivalent make. 61.00 supply only conventional smoke detector along with base, low profile design, low current draw, wide operating voltage 8 to 30 v, dc supply, bi colour led detector, status indicator, tested and approved to en54 specifications complete all as per system sensor cat part no 2315 e or its techno commercial equivalent of approved makes specified here in after....

Karnataka Power Transmission Corporation Limited - Karnataka

23459340 tender for site survey, planning, testing, design, engineering, supply, erection and commissioning of opgw cable by replacing existing earth wire in 220kv & 40okv transmission lines under buy back in karnataka state (kptcl) on total turnkey basis including supply of all matching materials! equipments and erection of all materials/ equipments, testing and commissioning....